DOOR SENSOR, EXIT BUTTON & ALARM
CONNECTION
STANDALONE INSTALLATION LOCK RELAY CONNECTION
INSTALL ON THE BARRIER GATE
Please thread the wire through the bracket before
installation.
1Drill a hole on the barrier gate, insert the bracket
into the hole and fix it with a nut.
2Adjust the angle of the device.
①
②
Output
Wiegand
Door Sensor
AlarmCard Reader
Smoke
Detector
Exit
Button
Electric Lock
Door sensor
Alarm power
Alarm
-
+
-+
-+
-+
Detector power
Smoke detector
Exit button
AUX
AL+
AL-
NC
COM
NO
BUT
GND
SEN
GND
GND
The system supports Normally Opened Lock and Nor-
mally Closed Lock.
The NO LOCK (normally unlocked when power-on) is
connected with ‘NO’ and ‘COM’ terminals, and
the NC LOCK (normally locked when power-on) is con-
nected with ‘NC’ and ‘COM’ terminals.
Take NC Lock as an example below:
Device not sharing power with the lock
*Do not reverse the polarity
Device sharing power with the lock
Normally Closed Lock
DC12V
DC12V
+12V
GND
FR107
GND
AUX
GND
SEN
GND
BUT
NO
COM
NC
AL-
AL+
*Maximum 30V 3A input.
FR107
Normally Closed Lock
DC12V
+12V
GND
GND
AUX
GND
SEN
GND
BUT
NO
COM
NC
AL-
AL+