mr. steam SMART/TWO Installation instructions

S
t
3
/VI r
-
Stea
SMART/REMOTE COMPATIBLE
SMART/TWO CONTROL
INSTALLATION & OPERATION INSTRUCTIONS
SMART/TWO BOX CONTENTS
1.
SMART/TWO CONTROL
4. INSTALLATION & OPERATION 6. WHITE DECAL
2.
CONTROL CABLE
INSTRUCTIONS
7. BLACK DECAL
3.
TUBE OF SILICONE
5. TEMPLATE
1.
LOCATING THE CONTROL INSIDE OR OUTSIDE THE STEAMBATH ENCLOSURE:
The SMART/TWO control is designed to be installed inside the steambath enclosure. However, if it
is necessary to install the SMART/TWO outside the steambath enclosure, a separate kit (#MSNC)
must be obtained by contacting Mr. Steam at 1-800-76-STEAM.
2.
INSTALLATION OF THE CONTROL INSIDE THE STEAMBATH ENCLOSURE:
It is highly recommended that the SMART/TWO control is located about four to five feet above the
floor. The control should be away from direct shower spray and must be away from the steam
source, preferably on an opposite wall. The Control should also be kept away from hot water piping
and steam piping.
3.
DETERMINE IF THE INSTALLATION OF AN ELECTRICAL BOX IS REQUIRED:
This control operates on a low voltage signal. Check your local building codes to determine if the use
of an electrical box is required.
4.
USING THE SMART/TWO CONTROL WITH A SMART/REMOTE CONTROL:
The SMART/REMOTE is an optional control which extends the SMART/TWO control ON/OFF
feature to a selected location outside the steambath enclosure. For additional information about the
SMART/REMOTE control, call Mr. Steam at 1-800-76-STEAM.
If the optional SMART/REMOTE is to be used then follow instructions provided with the SMART/
REMOTE control. Do not proceed to install the SMART/TWO control without the SMART/REMOTE
instructions.
5.
A
CAUTION: DO NOT ROUTE THE CONTROL CABLE INSIDE CONDUIT TOGETHER WITH
POWER LINES OR CLOSE TO HOT WATER OR STEAM PIPING. DOING SO MAY RESULT IN A
MALFUNCTIONING CONTROL.
ISUSSMAN1
1G
R 0 IL' PI
MR. STEAM
IS A DIVISION OF SUSSMAN-AUTOMATIC CORPORATION
43-20 34th Street, Long Island City, NY 11101 (718) 937-4500 • (800) 767-8326 • FAX (718) 472-3526
WESTERN REGIONAL OFFICE: Sussman Automatic of California, Inc., 6050 West Jefferson Blvd., Los Angeles, CA 90016 (800) 727-8326 • FAX (310) 815-1878
http://www.mrsteam.com
PUR 100328
JUNE 97

SILICONE
BEAD
SILICONE
TUBE
N
A
Go
Pe
are
AV
G
S
t
e
ic
rom
Mr
A
sus
sm
----
MOUNTING SCREWS
CONTROL
FACE PLATE
FACE PLATE HOLES
CONTROL
CABLE
CONNECTOR
CONTROL CABLE
STEAM GENERATOR
WHITE
4-PIN PLUG
WHITE
4-PIN JACK
Th
CONTROL CABLE
•
PREPARE DESIRED LOCATION
FOR THE SMART/TWO CONTROL
B.
Route the control cable
from the wall cutout to the
steam generator. Locate the
end of the cable that has the
single black connector at the
wall cutout. Locate the other
end with the white connector
at the steam generator.
APPLY SILICONE TO SMART/TWO
CONTROL
A. Make sure that the area around the cut out or electrical box is
clean and free of debris.
B.
Run a bead of silicone along all four edges of the gasket as
required to create seal between the gasket and the wall.
STEP 2
FF ALL POWER TO THE STEAM
A
CAUTION!!! TURN 0
GENERATOR UNTIL STEP 3C. FAILURE TO DISCONNECT
N AN INOPERABLE CONTROL.
POWER MAY RESULT I
A.
Connect the control cable (the end with the white connector)
to the steam generator connector.
MOUNT CONTROL TO WALL WITH
SCREWS
A.
Make sure the THIS END UP" is pointed upward.
B. Fully insert the supplied screws into the face plate holes and
align with holes in wall.
C. Keep the screws aligned and push the control against the wall
until the adhesive gasket sticks firmly.
D. Tighten the screws until the gasket is firmly secured against
the wall.
E.
Remove excess silicone.
STEP 1
A.
Remove template peel-
off paper and attach the
template to the wall in
desired location. Drill and
cutout as shown. Be exact.
Clean all burrs and dust.
STEP 5
4
J
il
CONNECT THE CONTROL CABLE
TO THE STEAM GENERATOR
STEP 6

STEP 4
EXPOSE ADHESIVE SURFACE ON
BACK OF SMART/TWO CONTROL
STEP 8
SECURE DECAL TO FACE PLATE
Remove paper liner from back of SMART/TWO control to expose
adhesive surface. Discard paper liner.
EXPOSED ADHESIVE
SURFACE
PAPER LINER
(DISCARD)
A.
Remove TAB A
along with peel-off paper and rub down top
section of decal.
TAB A
AND TOP
PEEL-OFF SECTION
CONNECT THE CONTROL CABLE
STEP 3
TO THE SMART/TWO CONTROL
A.
Firmly connect the black
connector on the bottom
board.
B.
Check all power connections
C.
RESTORE POWER AND
SMART/TWO CONTROL
OPERATION INSTRUCTIONS
INSTALLATION GUIDE.
STEAM DURING TEST.
D.
AFTER POSITIVE TEST
If test results are negative
o
Mr Ste
am
8
REMOTE
rEZZE
\
• ..-
connector on the cable
of the SMART/TWO circuit
for proper installation.
TEST THE OPERATION
ACCORDING TO THE
ON BACK COVER
DO NOT EXPOSE CONTROL
RESULTS
proceed to STEP
review installation.
to the
OF THE
OF THIS
TO
4.
PLUG
SU
SWAN Aff0t.itg
■
o
4-PIN JACK
0
4-PIN
c
CORD
roc°'
/
•
CONTROL CABLE
STEP 7
ALIGN DECAL AND REMOVE
BOTTOM PEEL-OFF SECTION
A.
Align bottom edge
B.
Remove
TAB B
(bottom
rub down exposed
"
1
C/6
DECAL
ID
-14
of
TAB
adhesive
Ni
i
A
(top tab) with top of
tab) along with the peel-off
onto face plate.
ALIGN
.,,,,,
— ,
,
h
--'--:-
'
,
lo
S S
r
-
e
.
'
7)
—4111111111111111111111111111111111111111111
11111
■
control.
paper
TAB A
and
TABS
AND BOTTOM
PEEL-OFF
SECTION

TEMPERATURE
SCALE
INDICATOR LIGHT
ILLUMINATED
TEMPERATURE
BAR GRAPH
SMART/TWO OPERATION
1)
CONTROL "ON"
Depress and release the "ON" button. The SMART/TWO control will display the TEMPERATURE setting. Steam will
begin flowing out of the steam head after approximately five minutes. Steam will continue flowing for (60) minutes and
the temperature will be maintained at the indicated temperature setting. The butler logo lights up in the "ON" mode.
2)
CONTROL "OFF"
Depress and release the "OFF" button and the control will turn off and the steam will stop flowing. The
TEMPERATURE setting is reset and the memory is erased (see MEMORY). The butler logo is OFF during this mode.
3)
CONTROL "TEMPERATURE"
-
SETTING THE STEAMBATH TEMPERATURE
Depress and release the "TEMP" button to set the desired steambathing temperature. Each activation of the button will
increase the temperature of the steambath by (2) degrees. Temperature is set in increments of (2) degrees from (110)
degrees up to a maximum of (120) degrees. When the maximum temperature setting of (120) degrees has been
exceeded, the temperature will reset at (110) degrees. The temperature setting is visually indicated by the illuminated
bar graph and an adjacent temperature scale (see diagram below). The temperature setting can be changed to a new
setting at any time during the steambath.
4)
MEMORY
The SMART/TWO control automatically stores and displays the last preferred TEMPERATURE setting for the next
steambath. [Note: If the OFF button is activated
during
a steambath, the memory is erased and a steambath will start
with a default setting of (114) degrees.]
•

INSTALLATION TEMPLATE
MR STEAM a division of SUSSMAN-AUTOMATIC CORPORATION 43-20 34th Street, Lon; Island City, N.Y. 11101
TEL (718) 937-4500 (800) 76-STEAM
4431-4(----
DRILL
304-
LEK
CUTOUT
"BEd
1
INSTRUCTIONS
1.
TEMPLATE IS FOR INSTALLATIONS THAT DO NOT REQUIRE
A JUNCTION BOX
2.
IF THE CONTROL IS LOCATED INSIDE THE STEAMBATH IT
MUST BE INSTALLED AWAY FROM THE STEAMHEAD.
I
LOCATION.
3.
PEEL OFF THIS TEMPLATE AND STICK TO WALL IN DESIRED
4.
DRILL AND CUTOUT AS SHOWN. DO NOT OVERSIZE
CUTOUT.
5.
REMOVE TEMPLATE AND DISCARD
6. DO NOT STICK THIS TEMPLATE ON FINISHED WALLS THAT
MAY BE DAMAGED BY THE ADHESIVE BACKING.
DRILL---)D-
•
PUR 100245 2.19.97

='
1
1/
WALL
DIAGRAv
PROBE CABLE
( CONNECT TO CONTROL)
1/
STEAMROOM INTERIOR
TEMPERATURE
PROBE
SILICONE
SEALANT
SMART/TWO OR
SMART/PLUS CONTROL
DIAC-RAM • #2
Mr Steam ®
sussmAN AuromAnc
CORP.
PCWE1
ZUT7UT
PEWIT
5..104
RacrE
7E3
.,
vwcaE
4
,
REMOTE TEMPERATURE
PROBE CONNECTOR
/1/1
r
-
S
€.
r
Sept 97 PUR 100307
•structions
for
installing the remote temperature sensor
PN
MSNC:
NOTE: DO NOT INSTALL THE SMART/TWO OR SMART/PLUS CONTROL BEFORE THE REMOTE
TEMPERATURE SENSOR IS CONNECTED.
1.
Locate the remote temperature sensor about four to five feet above the floor. Locate
the sensor away from direct steam or direct shower spray.
2.
Drill a 7/32" hole thru the wall.
3.
Fill the hole with silicone ( provided)
4.
Insert the temperature sensor with 1/4" of the probe exposed inside the steam room as
shown in diagram #1.
5.
Remove all silicone from the exposed sensor tip and wall.
6.
Remove and discard the remote temperature jumper form the SMART/TWO or
SMART/PLUS control. Connect the remote temperature cable connector control as shown in
diagram #2.
•
'SUSSMAN'
L
ifestyle
IC,
R.OU
P{
MF. STEAMm
IS A DIVISION OF SUSSMAN-AUTOMATIC CORPORATION
43-20 34th Street. Long Island City, NY 11101 (718) 937-4500 • (800) 767-8325 • FAX (718) 472-325
WESTERN REGIONAL OFFICE: Sussman Automatic of California. Inc.. 6050 West Jefferson Blvd., Los Angeles, CA 90016 (800) 727-8
1
25 • FAX (31C) 815-1878
Table of contents
Other mr. steam Control Panel manuals
Popular Control Panel manuals by other brands

NAPCO
NAPCO Magnum Alert 1010LKDL Operating & installation instructions

Wachendorff
Wachendorff DMS9648O user manual

ritm
ritm Contact GSM-5-2 operating manual

Nittan
Nittan 1PM3-nLA Operating instructions manual

Texecom
Texecom Premier Elite Micro Contact-W installation manual

FireClass
FireClass FC501 Series Quick start setup guide