manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MSE
  6. •
  7. Laboratory Equipment
  8. •
  9. MSE SONIPREP 150 User manual

MSE SONIPREP 150 User manual

INSTRUCTIONMANUALFORTHESONIPREP150ULTRASONICDISINTEGRATORREADBEFOREUSE!
Models:-MSS150.CX3.1MSS150.CX3.571100-1129-060206
MSE(UK)LTD
HealthandSafetyatWork
MSE(UK)Ltdisrequiredunderthe1974HealthandSafetyatWorkActandotherUKlegislationasdesigners,manufacturers,suppliersandimportersofarticlesforuseatworktoensurethat,asfarasisreasonablypracticable,articleswhichwedesign,produce,supplyorimportaresafeandwithoutrisktohealth.Wearerequiredtoprovideinformationonthesafetyandhandlingprecautionstobeobservedwheninstalling,operating,maintainingandservicingourproducts.Suchadviceiscontainedinthismanual.Wearealsoobligedtoupdatethisinformationshouldcircumstanceschangeandtooperateasystemtothisend.Weshouldalsoliketopointout,howeverthatyouasusershaveanimportantresponsibilityintheprovisionandmaintenanceofsafeworkingpracticesandconditions.Accordingly,wedrawthefollowingmatterstoyourattention:1.Thisapparatusshouldonlybeusedasintendedandwithinitsdesignparametersbysuitablyqualifiedandtrainedpersonnelwhohavereadandunderstoodtherelevantsectionsofthismanual.2.Thismanualshouldbereadilyavailabletosuchpersonnelatalltimes.3.Inadditiontothatwhichiswritteninthemanual,normalcommon-sensesafetyprecautionsmustbetakenatalltimestoavoidthepossibilityofaccidents.Particularcareisrequiredwhenworkingwithapparatusathightemperatureorpressure.4.Installation,maintenance,repairsandservicingshouldonlybecarriedoutbyanMSE(UK)Ltdapprovedengineer,andconnectiontoelectricalsuppliesshouldonlybecarriedoutbysuitablytrainedpersonnel.TECHNICALSUPPORT,WARRANTYSERVICEANDMAINTENANCEUKcustomers;ifyouareinanydoubtwhatsoeverregardingthecorrectuseofthisapparatus,orifyourequireanytechnicaldataorassistance,pleasecontacttheMSE(UK)LtdTechnicalSupportDepartmentat:
MSE(UK)Ltd
WorsleyBridgeRoadTelephone+44(0)8706094097LowerSydenhamFax+44(0)2086508408LondonE-mail:sales@mseuk.co.ukSE265AZWebPage:www.mseuk.co.ukOVERSEASCUSTOMERS:ShouldcontacttheirlocalMSE(UK)Ltddistributor.ELECTRICITYSUPPLIES:VoltageandfrequencyMSE(UK)Ltdelectricalapparatusisofferedandlabelledforone,orforachoiceoftwoormorevoltagerangesand,wherenecessary,differentfrequenciesofmainssupply.MSE(UK)Ltddoesnotacceptanyresponsibilityfortheoperationofanysuchapparatusshoulditbeconnectedtoelectricitysupplieswhicharenormallyoutside,orvaryoutside,thestatedvoltageandfrequencyvaluesforwhichitisdesigned,norforanyconsequentialloss,damageorinjury,howsoevercaused.
ReadThisBeforeUse!
THISMACHINEHASBEENFITTEDWITHANEWTHUMBTURNLOCK.
THEMACHINEWILLOPERATEONLYWHENTHEDOORISLOCKEDANDTHELATCHISFULLYENGAGEDTOENSURETHEDOORISFULLYLATCHED,TURNTHETHUMBWHEELFULLYCLOCKWISETILLTHEFLATSONTHELOCKARESITTINGHORIZONTALLYTHISHASBEENINTRODUCEDWITHTHEOPERATORINMIND.ASSOONASTHEDOORISOPENEDTHEGENERATORISTURNEDOFFWHICHINTURNSTOPSANYACCIDENTALCONTACTWITHTHEOPERATORANDTHEENERGISEDPROBE.THISALSOSTOPSANYSOUNDWAVESFROMLEAVINGTHESOUNDPROOFEDCHAMBERWHENTHEDOORISOPENED.
DECLARATIONOFCONFORMITYaccordingtoEN45014-(BS7514)
MSE (UK) Ltd Registered Office: Worsley Bridge Road, Lower Sydenha , London SE26 5AZ. Registered in England and Wales No. 5098052
Documentno:71100.1253.1MSE(UK)Ltd
WorsleyBridgeRoad,LowerSydenhamLondon,SE265AZU.K.Telephone:+44(0)8706094097Fax:+44(0)86508408E-Mail:sales@mseuk.co.ukWeb:www.mseuk.co.uk
ThankyouforbuyingaMSE(UK)LtdSoniprep150.PleasereadthisoperatingmanualbeforeusingyourSoniprep;itwillprovideyouandyourcolleagueswithusefulinformationonallaspectsoftheequipment.Asourcustomer,weshouldliketoensurethatyouaretotallysatisfiedatalltimes.Donothesitatetocontactourteam.Yourviewsareveryimportanttous
MSE(UK)LTDPRODUCTWARRANTYTermsandConditions
WehopethatyoudonothavetheneedtousetheextensivewarrantycoverthatMSE(UK)Ltdextendstoyou.Howevershouldyouhaveaproblem,ourpromptresponseisgreatlyhelpedifyouhavefilledinandpostedthepre-paidWarrantyRegistrationCardsuppliedwithyournewequipment.MSE(UK)Ltdgivesaone-yearwarrantyfromthedateofdelivery.Duringthisperiod,componentpartsproventobedefectiveinmaterialsorworkmanshipwillberepairedorreplacedatourexpense.Installation,commissioningandcalibrationarenotcoveredbythiswarrantyagreement.TheMSE(UK)Ltdapprovedserviceagentmustbecontactedforwarrantydeterminationanddirectionpriortoanyworkbeingcarriedout.Thesewarrantiesareonlyapplicabletonewproducts,andnotsecondhandnorrefurbishedproductsevenifrepairedbyMSE(UK)Ltd.Anysuchproductsarecoveredbyseparatewarrantytermsandconditionswhichwillbemadeavailableonrequest.ReplacementorrepairofcomponentpartsorequipmentunderthiswarrantyshallnotextendthewarrantytoeithertheequipmentorthecomponentpartbeyondtheoriginaloneyearwarrantyperiodunlessagreedinwritingbyMSE(UK)Ltd.Theabovewarrantiesareextendedtotheoriginalpurchaseruponfullinvoicepayment.Apurchasereceiptorotherproofofpurchasemayberequiredbeforewarrantyservicewillbeperformed.Thesewarrantiesonlycoverfailuresduetodefectiveworkmanshipwhichoccurduringthenormaloperationoftheproductbytheoriginalpurchaser,andnotfailureswhichresultfromaccident,misuse,abuse,neglect,mishandling,misapplication,alteration,faultyinstallation,electricalpowerfluctuations,dust,orotherenvironmentalextremes,modificationorserviceotherthanbyanapprovedserviceagentorfollowingthewrittenauthorityofthemanufacturer,ordamagethatisattributabletoactsofGod.Expendableitemssuchasmotorbrushes,doorseals,lidseals,‘O’ringsorlampsareexcluded.MSE(UK)Ltd,oritsapprovedserviceagent,reservestherighttorepairdefectiveequipmentonthepremisesofthecustomer,orataservicestation,atthesolediscretionofMSE(UK)Ltdortheirapprovedagent.Intheeventofreturntoanapprovedservicecentrethecustomerisresponsibleforthesafepackagingoftheinstrumentandnotificationtotheservicecentre.NeitherMSE(UK)Ltdnoritsagentsareresponsibleforanydamageoccurringduringshipment.SpecificationandMaterialChanges:MSE(UK)Ltdreservestherighttosupplyourlatestandimprovedmodelsattimeofshipment.Taxes:ThepricesquoteddonotincludeanytaxesimposedbytheStateorCountryinwhichthepurchasewasmade.Installation:Installationofallequipmentshallbeattheexpenseofthepurchaserunlessstatedotherwise.Accesstothesite,andtheprovisionofrequiredutilitiese.g.power,wateranddrainagetosuitableconnections,willbetheresponsibilityofthepurchaser,andatthepurchaser'sexpense.Limitationofliability:Innoevent,whetherasaresultofbreachofcontractorwarranty,shallMSE(UK)Ltdbeliableforanyconsequentialorincidentaldamagesincluding,butnotlimitedto,lossofprofitorrevenues,lossofuseoftheequipmentoranyassociatedequipment,downtimecosts,costsofsubstituteequipment,costsoflabour,costsduetodelaysorclaimsofpurchaser'sowncustomersforsuchdamages.ThepurchaseragreestoindemnifyMSE(UK)Ltdandtoholdthemharmlessfromanyandallliability,claims,demands,actions,suits,expensesorcosts,includingattorney'sfeesrelatingtosuchconsequentialorincidentaldamages.Allexpressedandimpliedwarranties,includingthewarrantiesofmerchantablequalityandfitnessforaparticularpurposearelimitedtotheapplicationperiodofoneyear.Validity:Legalrightsvaryfromcountrytocountryandstateswithincountries,sosomeoralloftheexclusionsorlimitationslistedabovemaynotapply,butifanypartoftheseconditionsshallbefoundtobeunenforceableitshallnotaffectthevalidityorenforceabilityoftheremainderoftheconditions.
ELECTRICITYSUPPLY
Beforeconnectingthisapparatustotheelectricitysupply,checktheinformationgivenontheapparatusratingplateandensurethat:A)YoursupplyissinglephaseAC(alternatingcurrent)ofthestatedfrequencywiththeneutralnominallyatearthpotential.B)Yoursupplyvoltageiswithinthestatedrange.C)Thecurrentratingiswithinthecapacityofyoursupplyoutlet.D)Yourplugorelectricitysupplycircuitisfittedwithasuitablefuse.FuseRating220v-240v110v-120v5ampSeenote100V-120VWARNING!ThisapparatusmustbeearthedThewiresinthemainsleadarecolouredinaccordancewiththefollowingcode:220v-240v110v-120vLiveBrownBlackNeutralBlueWhiteEarthGreen&YellowGreenConnectthewirestoanon-reversible3pinplugasfollows:GreenandYelloworGreenwiretoterminalmarkedE(Earth),G(GroundcolouredGreenandYelloworGreen)ormarkedwiththeEarthsymbol.BlueorWhitetoterminalmarkedN(Neutral)orcommonorcolouredBlue.BrownorBlacktoterminalmarkedL(Live4)orPhaseorcolouredBrown.NOTE:100v-120vinstallationstocomplywithNationalandStateWiringCodesIMPORTANT:Consultanelectricianifindoubtorifyoursupplysystemhasanyofthefollowing:Noearth.Acolourcodedifferentfromabove.Reversibleplugs.Supplyandreturnleadsthatarebothaboveearthpotential.NOTE:Donottouchplugpinswithintwosecondsofplugremovalfromsocket.
CONTENTS8CONTENTS
1.INTRODUCTION....................................................................................................91.1GeneralDescription................................................................................91.2ControlPanelDescription....................................................................112.INSTALLATION...................................................................................................132.1PowerSupplyandFuses......................................................................133.PROBES..............................................................................................................143.1DescriptionandFunction.....................................................................143.2ExponentialMicroprobe.......................................................................143.3FittingaprobetotheTransducer........................................................143.4Positionoftheprobeintheliquidfortreatment................................143.5ProbeMaintenance...............................................................................153.6TestingProbePerformance.................................................................164.PROCESSINGSAMPLES...................................................................................174.1VesselsforSamples.............................................................................174.2BasicProcessing..................................................................................174.3BatchTreatmentVessel........................................................................184.4MeterFlowVessel.................................................................................184.5ContinuousFlowVessel.......................................................................185.OPERATINGINSTRUCTIONS............................................................................195.1ManualControl......................................................................................195.2TimerControl.........................................................................................195.3OptionalProcessTimerUnit(230Vunitsonly)..................................195.4OperatingInstructions..........................................................................196.CLEANING...........................................................................................................217.FAULTFINDING..................................................................................................217.1General...................................................................................................217.2Faultconditionscouldbe:-..................................................................217.3LooseProbe...........................................................................................217.4FatiguedProbeOrCouplingStud........................................................218.SPECIFICATIONS...............................................................................................228.1SpecificationForSoniprep...................................................................228.2SpecificationForProcessTimer.........................................................229.OPTIONALACCESSORIESFORTHESONIPREP150...................................2310.PRODUCTDISPOSAL-ISO14001COMPLIANCE..........................................23
INTRODUCTION91.INTRODUCTIONTheSoniprep150UltrasonicDisintegratorisaself-containedunitdesignedforconvenienttabletopoperation.Itincorporatesanacousticcabinet,whichreducesexternallyaudiblenoiseandultrasoundtoasafelevel.Atransparentdoorallowsobservationofthesampleduringsonication.Theapparatusisfactoryadjustedtotheuser'selectricalsupplyvoltageandfrequency.1.1GeneralDescriptionThegeneratorisasolid-statetransistoramplifier,whichprovideselectricalenergy,atanoutputfrequencyof23KHz,toahighefficiencypiezo-electrictransducer,whichconvertstheelectricalenergytomechanicalenergy.Thetransducer,mountedinthetopofthedisintegratorchamber,transmitsultrasoundbyhighfrequencyvibrationsviaatitaniumalloyprobe.Thereisachoiceofthreeprobes,whichscrewintothetransducerheadandtransmitenergyofapproximateamplitudeforanyspecificapplication.Eachprobeisdesignedtooperateatanominalfrequencyof23KHzconcentratingtheresultantultrasonicenergy,asrequired.Table1ProbeDetails
DescriptionTipDiameter
TransformationRatio
LargeProbeAssy.(solid)19mm(3/4’)3.8:1SmallProbeAssy.(solid)9.5mm(3/8’)5.5:1ExponentialMicroprobe3mm(1/8’)7:1
Thedisintegratorisdesignedtocopewithdifferentrequirementsandwillensurethatthereisthemaximumpossibleacousticenergyatthetipfortheprobe.Oncetheoutputlevelhasbeenselecteditiscontinuouslymaintainedbytheautomaticfeedbackfromthetransducer.Ameter,calibratedinmicrons,allowstheamplitudetobemonitoredcontinuously.Anadjustabletableandaretortclamparemountedonarodwithinthechamber.Thespecimentobetreatediscontainedinasuitabletubeclampedinpositionorinavesselplacedontheadjustabletable.
INTRODUCTION10
INTRODUCTION111.2ControlPanelDescriptionThecontrolpanelissituatedontherighthandsideoftheunit.Abriefdescriptionoftheirindividualfunctionsfollows:AmplitudeMeter-Themeteriscalibratedinmicronsandmonitorstheprobeamplitude,thatis,theactualmovementpeak-to-peakthatistakingplaceatthetransducer/probeinterface.Multiplyingthemeterindicationbythetransformationratiooftheparticularprobeinuse(SeeTable1)allowsactualmovementoftheprobetiptobedetermined.PowerControl-Clockwiserotationofthepowercontrolincreasestheamplitudeleveldisplayedontheamplitudemeter.Thiscontrolpermitssteplessselectionofpoweroutputtothetransducer,providinganaccurateandreproducibleamplitudesettingfortheparticularprobeinuse.Timer-Thisisa15minutetimingunitwithswitchingcontactsandaresettingorcancellationfacility.Itoperatesindependentlyofthestartswitchaftertheoutputlevelhasbeendetermined,thetimerequiredisselected.Theoperatinglampwillbeilluminated,ultrasonicationwillcommenceandthetimerwillstartrun-downtozero.Whenthetimeselectedhasruntheunitwillswitchoffautomaticallyandtheoperatinglampwillgooff.OverrideSwitch-Whenpressed‘ON’,allowstheunittooperatecontinuouslyregardlessofthetimeset.OperatingLamp-Whenilluminated,indicatesthatthepoweristhroughtothetransducer.
INTRODUCTION12
ControlPanel
INSTALLATION132.INSTALLATION2.1PowerSupplyandFusesWhentheequipmentisfirstreceived,makesurethevoltageselectorswitchiscorrectlypositionedtosuityourpowersupply.Thisswitchislocatedattherearoftheunit,nexttotheprocesstimerconnection.Table2-VoltageSelectorSwitchPositions
VoltagePositionIndication220/240Downward240120Upward120
Twoanti-surgefusesarefactoryfittedintheholderslocatedbeneaththemainsinletconnectionsocket.LocationoftheInstrumentandElectricalConnectionsPlacetheSoniprep150onasuitabletableorbenchandensurethatattherearoftheinstrumentisatleast50mm(2’)awayfromthewalltoallowadequateaircirculation.See‘ELECTRICITYSUPPLYSHEET’(frontofmanual)forplug/mainscabledetails.
PROCESSINGSAMPLES143.PROBES3.1DescriptionandFunctionTheprobeisaresonantelementusedforthetransmissionofvibratingmechanicalenergyfromthetransducertothesample.Theprimepurposeoftheprobeistoincreasethetransduceramplitudetoausablelevelor,toselecttheacousticpowertransfer.Ideally,materialusedforsuchprobesshouldhavegoodacousticproperties,highfatiguestrength,lowacousticlossanddensity.Itisessentialthatitshouldalsobecorrosionanderosionresistantandrelativelyinerttothematerialsbeingsonicated.Thematerialthatpossessesallthesequalitiesistitaniumalloyanditisfromthismaterialthatprobesavailableforusewiththedisintegrator,aremanufactured.Note:ProbesarespeciallydesignedtosuittheSoniprep150modelsandaretunedto23KHz.3.2ExponentialMicroprobeThisprobehasbeenspecificallydesignedforthetreatmentofsmallquantitiesofsample,upto5ml.Itshould,preferably,beusedwiththe20mltubeandsealingcapbutanyothersuitablysizedtubemaybeemployed.3.3FittingaprobetotheTransducerCleanthematingsurfacesoftheprobeandtransducerwithasoftcloth.Beforefittingtheprobe,screwthecouplingstudintothetransducerapproximately10mmleavingapproximately10mmprotruding.Screwtheprobeontothestudinthetransducerhead,byhand.Thentightenfirmlyusingashortscrewdriver'sshaftlocatedinthethroughholeintheprobe.Itisimportantthattheprobeisclampedsecurelytothetransducer,asfailuretodosowillresultinalargepowerlossandanirritatinghigh-pitchednoise.NOTE:Thecouplingstudisarelativelyloosefitinboththetransducerandtheprobetoensurethatthecontactsurfacesareallowedtomateperfectly.Anextremelysmallsmearofsiliconegreaseontheprobeheadwillfacilitatesurfacemating.3.4PositionoftheprobeintheliquidfortreatmentWhenmaximumpowerisnecessaryforadifficultapplication,theprobetipshouldbeimmersedintothesolutiontoanoptimumdepth.Asaguide,for50mlsampledownto10mlsample,thebestpositionfortheprobetipis1cmbelowthesurfaceofthesample.Ifthesampleislessthan10ml,thebestpositionfortheprobetipshouldbefoundbytrialanderror.Excessivedepthandalsotheviscosityofthesolutionwillcausethepowertobedamped,whichwillbeevidentbyalowerindicationontheamplitudemeter.Conversely,iftheprobetipisinsufficientlybelowthesurface,therewillbeatendencytogeneratefoaminthesolutionortocausescatteringofdropletsoutofthevessel.Thisisespeciallysowhenusinghighamplification.Ifthesolutionfoams,therewillbeadistinctchangeinsound,i.e.virtuallyunloadedandlittleenergyisbeingtransferredtothesolution.
PROCESSINGSAMPLES15Sometimes,whenthesolutionisthoroughlyaerated,theusualprocessnoisefromthebeakerortesttubewillstop,i.e.nobuzzorvibrationwillbeheard.Again,thisisbecausethereislittletransferofenergy.Whentheseconditionsoccur,turnthepoweroffforafewsecondsandsettheprobedeeper.Graduallyincreasethepowerandthesolutionwillde-gas.Thelowerthepowersetting,thesmallerwillbethequantitythatmaybeprocessedwithoutfoamingthesolution.Donotallowtheprobetocometoocloseto,ormakecontactwith,thesidesorbottomofglasscontainersaspowderedglassmaybeformedinthesolution,orbreakagemayoccur.Plastictubesaremoreresistanttofailureduringsonication,buttheinsulationpropertiesofplasticmaymakeitdifficulttokeepthesamplecool.CAUTIONItmustbeborneinmindthatsonicationcanweakenglasstubes.Itistherefore,advisablethatglasstubesusedinsonicationarenotsubsequentlycentrifugedathighspeedasfailureofthetubemayresult.3.5ProbeMaintenanceInusetheprobewillerodebytheactionofcavitationintheliquid.Thisdissolutionofthemetalfromthetipoftheprobe,whichoccurs,withanymetalduringuseathighsoundintensitiesis,however,reducedtoaminimumbytheuseoftitanium.Theerosionshowsitselfinconcentricringsontheradiatingface.Anerodedsurfacetransfersenergylessefficientlyintotheliquidthanasmoothonebecauseoftheformationofazoneofcavitationadjacenttothesurface.Energynottransferredintotheliquidmediumwilltendtoheattheendoftheprobe.Furthermore,erosioncontinuesatanacceleratedrateontheprobetipsurface,whichisalreadypitted,thusreducingtheusefullifeoftheprobe.Forthesereasonsthetipoftheprobeshouldbepolishedsmoothbymeansofaveryfineemeryclothonaflatsurface,butnotethefollowingtwocautions.CAUTION:a)ProbesWEAROUT,althoughprobesmaybepolished/reground,thelengthoftheprobemustnotbeshortenedbymorethan2mm.PROBESSHOULDBEREPLACEDANNUALLYORASREQUIRED.b)Thetransducer/probematingsurfacesmustnotbecleanedwithanabrasivecleaner.Shouldtheendrequirepolishing,ONLYALIQUIDNONABRASIVEPOLISHshouldbeused.
PROCESSINGSAMPLES163.6TestingProbePerformanceThefollowingtestshouldbecarriedoutsothatusersmaymonitortheperformanceofeachprobe.Measurethetemperatureriseobtainedatmaximumpowerafter5minuteswiththefollowingvolumesofchilledwater(i.e.below10°C).ProbeVolumeofChilledWaterExponential15ml9.5mm50ml19mm100mlAtemperatureriseofapproximately35°Cshouldbeobtained.Iftheriseisnotobtainable,theprobeorthetransducerisatfault.Topinpointthepartofthesystem,whichisfaulty,repeatthetestwithanUNUSEDprobe.Ifyoustilldonotobtainatemperatureriseofapproximately35°C,thencontacttheservicecentreattheaddressinsidethefrontcover.Theservicecentrewillgiveyoumoreadvice.
PROCESSINGSAMPLES174.PROCESSINGSAMPLES4.1VesselsforSamplesNOTE:MinimumVolume-Volumesoflessthan1mlmaybetreatedwiththeexponentialmicroprobe.Thesampleshouldbeheldinamicrotube.MaximumVolume-Amaximumof100mlmaybetreatedatanyonetime.However,largervolumesmaybeprocessedbyusingthetreatmentvessels.Itispreferabletouseanarrowvesselratherthanawideone.Twicethevolumeinanarrowvesseltakesashortertimetoprocessthanthesamevolumeinawidervessel.Twicethevolumeorconcentrationtakestwiceaslongtoprocess.Materialsthatareparticularlyresistanttoultrasonicenergy,however,shouldbeprocessedinthesmallestareapracticable.Sincetheenergyradiatesfromtheprobetipintheshapeofacone,themoreconfinedthesampleunderthetipthebettertheresults.Anarrow,relativelyshorttesttubeisalsocalledforwhenprocessingsmallquantities,sayoftheorderof4ml.Theprobetipshoulddisplaceasmuchliquidaspossibletoforcealongliquidheightor‘head’abovethevibratingtip.Thispreventsfoamingorwhippingthesolutionoutofthetesttube.Awidebeakerisnotnormallysuitable.Thereisconsiderableevidencethattheshapeofthecontainerhasgreatinfluenceontherateofreleaseofsolubleproteinortheefficiencyofthecellularbreakage.Thisisprobablymorethefunctionofmixingthananythingelse,sincetheindividualcomponentsarenotdirectlyexposedtotheactionoftheprobetipformorethanasecondortwo.Ifthevolumeisverylarge,thenindividualcellsarenotintheareaofcavitationactivityforasufficientperiodoftime.Theprobetipshouldbebelowthesurfaceoftheliquidbyapproximately13mm(1/2’)andshouldnotbetoofarfromthebottomofthevessell(againapproximately13mm).Ifthetipisnotsatisfactorilyimmersed,aconsiderablequantityofairmaybetrappedinthesolutionthusdissipatingthepowerdeliveredandnotallowingittobetransmittedtothesolution.AsthereissufficientforcegeneratedbytheSoniprep150tofractureorshatterglass,theprobetipmustnotbeallowedtocomeincontactwith,orcomecloseto,thebottomofthevessel.4.2BasicProcessingTesttubesof20mland100mlnominalcapacityareavailableforcertainapplications.Inadditiontothese,cooledtreatmentvesselsareavailableforusewhenitisimportantthatthemediabeingtreatedshouldbesubjectedtominimaltemperaturerise.Arangeofrubbersealingcapsareavailableforalltubesandcooledtreatmentvessels.Theprobeisinsertedthroughthesealingcapwhichfitsoverthemouthofthevessel,ortube,andprovidesanairtightseal.Foreaseofmanipulationandtoeffectthebestpossibleseal,theedgeoftheholeinthesealingcapshouldbelightlysmearedwithsiliconegrease.Whenusingsealingcaps,ensurethetubeissecurelyclampedtopreventdownwardmovementofthetubeandconsequentdisengagementfromtheprobe.
PROCESSINGSAMPLES18Whenfittingsealingcaps,theairpressurewhichmayhavebuiltupcanbereleasedbyliftingtheedgeofthecapslightly.Thecapsaremanufacturedfromamaterialwhichissuitableforautoclaving.Whentreatingsamplesinanyofthetesttubesthetemperatureofthesuspensionwillrise,especiallyifthequantitiesofthematerialbeingtreatedaresmall.Toavoidthistemperaturerise,immersethetubecontainingthemediuminabeakercontainingcrushediceorasuitablecoolingmixture.Thebeakercanbeplacedontheadjustableplatformandthevesselcontainingmediumheldinthelaboratoryclamp.However,ifthemediumbeingtreatedisparticularlysensitivetotemperature,thenoneofthecooledtreatmentvesselsdescribedinsections4.3,4.3and4.4shouldbeused.4.3BatchTreatmentVesselThisconsistsofaninnerchambertocontainupto50mlofsampletobetreated,surroundedbyacoolingjacketthroughwhichasuitablecoolingliquid(e.g.icedwateroralcohol)canbecirculated.4.4ContinuousFlowVesselThisisavailableforthetreatmentofevenlargervolumeswheretherequireddisintegrationtimeisrelativelyshort.Thisvesselhasbothinletandoutlettubestotheinnerchamberwhichallowsthesampletobepassedcontinuouslythroughatameasuredflowrateasdisintegrationtakesplace.Aperturesareprovidedinthebackoftheultrasoniccabinetsothattheliquidfeed-linescanbepassedthroughtothetreatmentvesselsandpermitsonicationwiththecabinetdoorclosed.
OPERATINGINSTRUCTIONS195.OPERATINGINSTRUCTIONSMisusesinclude:a)Impedingairflow.b)Incorrectpositioningoftheprobeswithrespecttothetransducer(seesection3.4).c)Lackofprobemaintenance(seesection3.5).d)Probeinliquid(foaming).5.1ManualControla)Plugthe3pinplugintothepoweroutlet.Switchthegreensupplyrockerswitchtoits‘ON’position(itsinnerLEDwillilluminate).b)Openthedoor,placethevesselcontainingthesampletobetreatedontheplatform,orifatesttube,clampinpositionandsetupforsonicationasrequired.Closethedoor.c)Presstheoverrideswitch,theamberlampwillilluminateandsonicationcancommenceonceamplificationisset(ifnotsetcorrectlyfromapreviousoperation).d)Ifnotset,thenselectamplitudelevelrequired.e)Aftersonicationiscomplete,switchthesupplyrockerswitchtoits’OFF’position.5.2TimerControla)Carryoutinstructionsinsection5.1a)andb).b)Settime,1to10minutes,byturningknobclockwise.ImmediatelytheTimerbuttonisturnedclockwisetheStartbuttonlampwilllightup,andafterthetimeselectedonthetimerhasrunout,sonicationwillceaseandthelampwillgooff.5.3OptionalProcessTimerUnit(230Vunitsonly)a)PlacetheProcesstimerUnitontopoftheSoniprep.b)Connectthetwocablesfromtheprocesstimer-oneterminatinginathree-pinplug(power)andtheotherterminatinginafive-pinplug(control)-tothecorrespondingsocketsontherearoftheSoniprep.5.4OperatingInstructionsa)Setupthedesiredoperatingconditionsonthedigitalswitchesoftheprocesstimerunit.b)EnsuretheSonipreppowerisONandthattheamplitudeissetorsetwhenthesonicationstarts.TheoverrideswitchshouldbeturnedOFF.c)Switchontheprocesstimermainsswitch.Thegreenmainslampwillilluminate.d)Pressthestartswitchpush-buttonontheprocesstimerunit.TheSoniprepwillnowoperateunderthecontroloftheprocesstimerunit.Ifitisrequiredtostoptheprocessduringsonication,pressthestopbuttonontheprocesstimerunit.Sonicationwillceaseandthetimerwillresetforthenextcycle.
OPERATINGINSTRUCTIONS20
ProcessTimer

Other MSE Laboratory Equipment manuals

MSE MicroCentaur Plus User manual

MSE

MSE MicroCentaur Plus User manual

MSE HARRIER User manual

MSE

MSE HARRIER User manual

MSE Kestrel User manual

MSE

MSE Kestrel User manual

MSE CENTAUR 2 User manual

MSE

MSE CENTAUR 2 User manual

Popular Laboratory Equipment manuals by other brands

Scienceware Colony Counter instructions

Scienceware

Scienceware Colony Counter instructions

Thermo Scientific Invitrogen E-Gel G8000 quick start guide

Thermo Scientific

Thermo Scientific Invitrogen E-Gel G8000 quick start guide

Conrad 97 52 27 operating instructions

Conrad

Conrad 97 52 27 operating instructions

Tektronix Sony 370A Operator's manual

Tektronix

Tektronix Sony 370A Operator's manual

Forma Scientific 1284 instruction manual

Forma Scientific

Forma Scientific 1284 instruction manual

PSC PowerScan Quick reference guide

PSC

PSC PowerScan Quick reference guide

Roth AQUASTOP II Operation manual

Roth

Roth AQUASTOP II Operation manual

Four E's Scientific MI0102008 operating instructions

Four E's Scientific

Four E's Scientific MI0102008 operating instructions

Thermo Scientific MaxQ Mini 4450 series manual

Thermo Scientific

Thermo Scientific MaxQ Mini 4450 series manual

Keysight M8195A Getting started guide

Keysight

Keysight M8195A Getting started guide

Altronix NetWay1DWP installation guide

Altronix

Altronix NetWay1DWP installation guide

Fluke TiR4 user manual

Fluke

Fluke TiR4 user manual

Struers Xmatic Compact instruction manual

Struers

Struers Xmatic Compact instruction manual

ThermoFisher Scientific TX-750 instruction manual

ThermoFisher Scientific

ThermoFisher Scientific TX-750 instruction manual

Hitachi SEM S-4700 user manual

Hitachi

Hitachi SEM S-4700 user manual

Deltec TC 2060 Operating	 instruction

Deltec

Deltec TC 2060 Operating instruction

Molecular Devices SpectraMax L user guide

Molecular Devices

Molecular Devices SpectraMax L user guide

Flexicon FF30 Instruction handbook

Flexicon

Flexicon FF30 Instruction handbook

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.