EN-19N
Earth to Neutral Relay
FEATURE
TECNICAL SPECIFICATION
MECHANICAL DIMENSION
Earth to Neutral Voltage Monitoring In 1Ø - 2W, 3Ø-3W
And 3Ø-4W
System
Auto/Manual Triping Reset Facility.
Trip Reset Via Front Key
Input Voltage
Display Voltage Range
Resolution
0 To 10 V AC
0.00 To 10.00 V AC
0.01 V AC
INPUT SPECIFICATION :
Display
Keys
Upper: 4 Digit , 7 Seg. 0.56” Red
Lower: 4 Digit , 7 Seg. 0.56”Green
SET, INC, DEC, ENT/RST
AUXILIARY SUPPLY :
Supply Voltage 100 To 250 V AC
Power Consumption
(VA Rating) 4VA @ 230 VAC MAX
DISPLAY & KEYS :
TERMINAL CONNECTION
Page -1
96 52
92
92
3
96
Outline Dimension (mm) Panel Cutout
Dimension (mm)
ENVIRONMENT CONDITION:
Relative Humidity
Protection Level
(As per request)
Operating Temp. 0°C to 55°C
UP to 95% RH
(non-condensing)
IP-65 (Front side) As per IS/IEC
60529 : 2001
Read complete instructions prior to installation
and operation of the unit.
WARNING : Risk of electric shock.
SAFETY PRECAUTION
!
All safety related codifications, symbols and instructions that
appear in this operating manual or on the equipment must be
strictly followed to ensure the safety of the operating personnel
as well as the instrument.
If all the equipment is not handled in a manner specified by
the manufacturer, it might impair the protection provided by the
equipment.
MAINTENANCE
1. The equipment should be cleaned regularly to avoid blockage
of ventilating parts.
2. Clean the equipment with a clean soft cloth. Do not use
isopropyl alcohol or any other cleaning agent.
3. Fusible resistor must not be replaced by operator.
WARNING GUIDELINES
WARNING : Risk of electric shock.
1. To prevent the risk of electric shock, power supply to the
equipment must be kept OFF while doing the wiring
arrangement. Do not touch the terminals while power is
being supplied.
2. To reduce electro magnetic interference, use wire with
adequate rating and twists of the same of equal size shall
be made with shortest connection.
3. Cable used for connection to power source, must have a
cross section of 1mm or greater. These wires should have
insulations capacity made of at least 1.5kV.
4. When extending the thermocouple lead wires, always use
thermocouple compensation wires for wiring for the RTD
type, use a wiring material with a small lead resistance
(5 max per line) and no resistance differentials among
three wires should be present.
5. A better anti-noise effect can be expected by using
standard power supply cable for the instrument.
Ω
INSTALLATION GUIDELINES
1. This equipment, being built-in-type, normally becomes a
part of main control panel and in such case the terminals
do not remain accessible to the end user after installation
and internal wiring.
2. Do not allow pieces of metal, wire clippings, or fine metallic
fillings from installation to enter the product or else it may
lead to a safety hazard that may in turn endanger life or
cause electrical shock to the operator.
3. Circuit breaker or mains switch must be installed between
power source and supply terminal to facilitate power ‘ON’
or ‘OFF’ function. However this mains switch or circuit
breaker must be installed at convenient place normally
accessible to the operator.
4. Use and store the instrument within the specified ambient
temperature and humidity ranges as mentioned in this
manual.
MECHANICAL INSTALLATION GUIDELINES
1. Prepare the panel cutout with proper dimensions as shown
above.
2. Fit the unit into the panel with the help of clamp given.
3. The equipment in its installed state must not come in close
proximity to any heating source, caustic vapors, oil steam,
or other unwanted process Byproducts.
4. Use the specified size of crimp terminal (M3.5 screws) to
wire the terminal block. Tightening the screws on the
terminal block using the tightening torque of the range of
1.2 N.m.
5. Do not connect anything to unused terminals.
R
Earth to Neutral Voltage Relay
ENT
RST
SET
EN 19N
Voltage
Set Value
1 8 3
1 0 0 0
KEY OPERATION
OPERATION MODE
For 2 sec
PARAMETER SETTING MODE
FUNCTION KEY PRESS
To Enter in Parameter Setting
To Reset the Relay Contact
Manually After Tripping
ENT
RST
SET
To set parameter value
To increment parameter value.
To decrement parameter value.
Set parameter to be save & exit.
SET
ENT
RST
12347 8 9
12
1314
10
11
5
1617181920
6
15
Range: 0.00 To 10.00V AC
NCCNO
Input: 0 To 10V AC
I/P
0 To 10V AC
E N
LN
100
250V AC
~
50/60 HZ
4VA !
MadeinIndia
www.multispanindia.com
Size (mm)
Panel Cutout
96(H) X 96(W) X 52(D)
92(H) X 92(W)
DIMENSION :
Relay
Relay Type
Rating
1 Nos.
1 C/O (NO-C-NC)
10A,230V AC Resistive Load
OUTPUT SPECIFICATION :