Mylek kpt-2000b User manual

USER INSTRUCTIONS
Product Code: KPT-2000B 5201L
PTC Over Door Heater and Fan
1

IMPORTA T
Installer and Users please note:
These instructions should be read carefully before installation and/or use and left with the user of
the product for future reference.
BEFORE USE
You must inspect the appliance including its cable and plug for any signs of damage. If the product
is damaged, DO OT use it, and contact your supplier immediately.
Product Safety
CAUTIO – Some parts of this product can become very hot and cause burns.
Particular attention has to be given where children and vulnerable people are
present.
1. The appliance is to be operated by responsible adults only after reading and
understanding these instructions. Children from 8 years and above and persons with
reduced physical, sensory or mental capabilities shall only switch on/off the appliance
provided that it has been placed or installed in its intended normal operating position
and they have been given supervision or instruction concerning use of the appliance in
a safe way and understand the hazards involved. Children less than 8 years shall not
plug in, regulate and/or clean the appliance or perform user maintenance.
2. Cleaning and user maintenance shall not be made by children without supervision.
3. Children should not play with the appliance and if less than 3 years old should be kept
away unless continuously supervised.
4. f the supply cord is damaged, it must be replaced by the manufacturer or its service
agent or a similarly qualified person in order to avoid a hazard.
5. Do not install the heater directly under the socket outlet.
6. Do not place the mains lead beneath a carpet or rug.
7. Make sure that the correct plug is used.
8. The appliance should not be used in locations where paint, petrol or other flammable
liquids are used or stored. Do not place/install the heater on flammable surfaces or near
to flammable articles.
9. Ensure that curtains are at least 900mm (3 feet) from any point of the heater.
10. Leave a gap of at least 300mm (12 inches) at the sides and above the heater from other
objects.
11. f the fan stops running the appliance should be turned off immediately.
12. Warning: Do not cover the heater or place objects on or touch the safety net. For indoor
use only.
.
2

13. Unplug from the outlet when not in use and before cleaning.
14. Do not install the appliance in bathrooms or other humid, wet or damp environments.
15. Do not expose the unit to dusty atmospheres.
16. f any liquids or foreign bodies are spilled into the unit turn the appliance off at the unit
and mains immediately. Do not try to operate and contact a qualified person for advice.
Do not insert any object into the heater through the grilles. This may damage the heater
. or result in overheating or electric shock.
Operating instructions:
I. Features of the Product
This product uses an electrical heater and has high efficiency. There are no open flames and no
oxygen consumption.
The solid high-quality plastic housing has a long life span.
The unit produces little noise. The ventilator produces a gentle wind stream.
The two-stage temperature is suitable for different environments.
II. Technical Data
Type Specification Voltage Frequency Power
KPT-2000B 5201L remote control 230V 50 Hz 1000W/2000W
I Installation
The heater is intended to be mounted at least 1.8m height and over a door or entrance.
The air outlet must hang downwards on the wall and in a horizontal plane. Do not install the
appliance differently or at an angle.
Bore 2 holes, which 2.0 m over the floor, on the wall. The hole diameter must be sufficient for the
plastic pegs. Put plastic pegs into the holes. Secure to the wall using screws. See the image below.
3

PAT TESTI G
When used in a workplace, this product must be safety-tested yearly by a qualified electrician
(PAT Tested) in order to comply with the Electricity at Work Regulations. We recommend that it
is PAT tested regularly when used in a domestic environment.
GE ERAL SAFETY REQUIREME TS
Domestic wiring must be tested periodically by a qualified electrician at least once every 10
years or at every change of occupancy. For office and retail premises, and buildings such as
village halls, the wiring must be inspected at least once every 5 years. t is recommended that all
buildings be fitted with smoke alarms (it is mandatory for new buildings).
III. Operation
Before use check that the voltage power corresponds to the one shown on the appliance’s
nameplate.
Make sure you are using the correct plug.
Mechanical mode ( button)
Press button to operate, the unit will start working and blow cool air;
Press button for the second time, the unit will blow warm air (1000W).
Press button for a third time, the unit blow hot air (2000W).
Press button for a fourth time, The unit will stop working.
Switch on again, the unit will return to working mode and blow cool air. Cycle option.
Attention: it is recommended that you let the unit blow cool air for 30 seconds and then turn the
unit off.
All working modes will be shown on the LCD display screen.
Mechanical mode ( timer button)
From 1h to 8h . The timer operates from 1h-2h-3h-4h-5h-6h.....until the 8h
Mechanical mode ( „+“,“-„ )
Temperature adjustor
Remote control operation; see photo below
Press button to start working
Press function button to choose 1000W or 2000W power
Press timer button. Operates as per the timer on the panel
Press ‘+”& ‘-’ to adjust the temperature.
4

During use press ‘+’& ‘-‘ to control the temperature. When the room temperature rises to
the required/set temperature the heater will turn off. When the room temperature drops to
below 3 ℃ of the set temperature, the heater starts to operate again.
Regulate temperature by ‘+’ ‘-‘ buttons. To start-up again - the first time you press ‘+’ ‘-‘,
the temperature will start from 25℃ ( then change according to last the last required/set
temperature), keeping between 49℃ and 10℃. Each press will change the temperature
by 1℃. When you press ‘+’ & ‘-‘ the LED display shows the target temperature. When you
have set the target temperature the LED display reverts to showing the present
room/ambient temperature.
IV. Cleaning and Maintenance
Unplug from the outlet before cleaning. Allow the unit to cool before cleaning the appliance. To clean the
surface use a soft wet cloth. Make sure that you do not pour water on to the appliance. Do not use
any organic solvents.
f you do not use the appliance for a long time, wipe off the surface and store the appliance in the origina
l packing box in a well ventilated place. Avoid damp areas and impacts to the unit.
Environmental Responsibilities
Mea i g of crossed –out wheeled dustbi :
Do ot dispose of electrical applia ces as u sorted mu icipal waste, use separate
collectio facilities.
Co tact your local cou cil for i formatio regardi g the collectio systems available.
If electrical applia ces are disposed of i la dfills or dumps, hazardous substa ces ca
leak i to the grou dwater a d get i to the food chai damagi g your health a d well-
bei g.
Whe replaci g old applia ces with ew o es, the retailer is legally obligated to take
back your old applia ce for disposal free of charge.
WARNING
This applia ce is ot i te ded for use by perso s (i cludi g childre ) with reduced physical, se sory or
me tal capabilities, or lack of experie ce a d k owledge. Childre should be supervised to e sure that
they do ot play with the applia ce.
SERVICE WARRA TY
XXXXX guara tees the product free from defects i materials a d workma ship for a period of XX
years.
Should this u it be operated u der co ditio s other tha those recomme ded, at voltages other tha the
voltage i dicated o the u it, or a y attempts made to service or modify the u it, the the warra ty will
be re dered void. The product you buy may sometimes differ slightly from illustratio s. This warra ty is
i additio to, a d does ot affect, your statutory rights. If you have a y problems with this product,
please call our Help Desk o XXXX
XXXX., Castleford W. Yorkshire
website: www.
5

6
Table of contents