One or several lights are not working (fans work normally)
Troubleshooting
Turn o the power switch (see
control box layout c).
Check if DC cords are securely
connected to the J7, J8, J9 in
the control box (see control box
layout k).
01
01
04
03
06
0302
02
05
05 06
07
07
04
Check if ceiling light DC cords are
connected with control box light
DC cords (see the light connection
picture).
Gently pull out the light from the
ceiling.
Check if connectors are securely
connected.
If any of the cords are missing or
broken, please contact NARBUTAS
support for the replacement part.
If all of the above are correctly connected it is likely that there is an
issue with the LED light itself. See LED replacement instruction here:
instructions.narbutas.com/var/docs/M60ES124.pdf →
One or both fans are not running (lights work normally)
Turn o the power switch (see
control box layout c).
Check if DC cords are securely
connected to the J5, J6
connectors of the control box
(see control box layout j).
Check if ceiling ventilation DC
cords are connected with control
box ventilation DC cords (see the
ventilation connection picture).
Unscrew the M4x10 (4 pcs.) and
take out the fan module.
Check if connectors are securely
connected.
Contact NARBUTAS support if the
replacement part is required.
If all of the above are correctly connected it is likely that there is an issue
with the fan itself. See fan replacement instruction here:
instructions.narbutas.com/var/docs/M60ES125.pdf →