Nederman TAV 100 User manual

Vacuum Valve
TAV 100/150
144212(02)2016-02-29
Original user manual
EN USER MANUAL
Translaon of original user manual
CS NÁVOD K OBSLUZE
DA BETJENINGSVEJLEDNING
DE BEDIENUNGSANLEITUNG
ES MANUAL DE INSTRUCCIONES
FI KÄYTTÖOHJEET
FR MANUEL D’INSTRUCTION
IT MANUALE D’ISTRUZIONE
NL HANDLEIDING
NO BRUKSANVISNING
PL INSTRUKCJA UŻYTKOWANIA
PT MANUAL DE INSTRUÇÕES
SV ANVÄNDARMANUAL
UserManual


TAV 100/150
3
Declaraon of conformity................................................................................................ 4
Figures.................................................................................................................................................................. 7
English...............................................................................................................................................................12
Český .................................................................................................................................................................20
Dansk ................................................................................................................................................................ 27
Deutch..............................................................................................................................................................34
Español............................................................................................................................................................ 41
Suomi.................................................................................................................................................................49
Français...........................................................................................................................................................56
Italiano.............................................................................................................................................................64
Nederlands...............................................................................................................................................72
Norsk .................................................................................................................................................................80
Polski .................................................................................................................................................................87
Português...................................................................................................................................................95
Svenska.......................................................................................................................................................103

TAV 100/150
4
Declaration of conformity
Declaraon of conformity
We,ABPh.Nederman&Co.,declareunderoursoleresponsibilitythatthe
Nedermanproduct:
TAV100/150(PartNo.**,andstatedversionsof**)towhichthisdeclaraon
relates,isinconformitywithalltherelevantprovisionsofthefollowing
direcvesandstandards:
Direcves
B.
Standards
A.
Thenameandsignatureattheendofthisdocument,isthepersonresponsible
forboththedeclaraonofconformityandthetechnicalle.
English
EN
Konformitätserklärung
Wir,ABPh.Nederman&Co.,erkläreninalleinigerVerantwortung,dassdas
NedermanProdukt
TAV100/150(Art.-Nr.**,undbauartgleicheVersionen**),aufwelchessich
dieseErklärungbezieht,mitalleneinschlägigenBesmmungenderfolgenden
RichtlinienundNormenübereinsmmt:
Richtlinien
B
Normen
A.
NameundUnterschriamDokumentendegebendiejenigePersonan,diefür
dieKonformitätserklärungunddietechnischeDokumentaonverantwortlichist.
Deutsch
DE
Overensstemmelseserklæring
ABPh.Nederman&Co.erklærersomeneansvarlige,atfølgendeproduktfra
Nederman:
TAV100/150(Arkelnr.**,ogerklæredeversioneraf**),somdenneerklæring
vedrører,erioverensstemmelsemedallederelevantebestemmelseride
følgendedirekverogstandarder:
Direkver
B.
Standarder
A.
Navnetogunderskriensidstideedokumentlhørerdenperson,der
eransvarligforsåveloverensstemmelseserklæringensomdentekniske
dokumentaon.
Dansk
DA
Declaración de Conformidad
Nosotros,ABPh.Nederman&Co.,declaramosbajonuestraúnica
responsabilidadqueelproductoNederman:
Elproducto,TAV100/150(Ref.nº**,ylasversionesbasadas**),,alquehace
referenciaestadeclaración,cumplecontodaslasdisposicionesaplicablesdelas
Direcvasynormasqueseindicanaconnuación:
Direcvas
B.
Normas
A.
Elnombreyrmaqueguranalnaldeestedocumentocorrespondenala
personaresponsable,tantodeladeclaracióncomodelachatécnica.
Español
ES
Prohlášení o shodě
My,společnostABPh.Nederman&Co.,prohlašujemenasvouzodpovědnost,že
výrobekNederman:
TAV100/150(dílč.**,auvedla,verze**),kekterémusetotoprohlášení
vztahuje,jevsouladusevšemipříslušnýmiustanoveníminásledujícíchsměrnic
anorem:
Směrnice
B.
Normy
A.
Nakoncitohotodokumentujejménoapodpisosobyzodpovědnézaprohlášení
oshoděasoubortechnickédokumentace.
Češna
CS
Vaamustenmukaisuusvakuutus
Me,ABPh.Nederman&Co.,vakuutammeyksinomaanomallavastuullamme,
eäNederman-tuote
TAV100/150(tuotenro**,jatotesiversioita**),jotatämävakuutuskoskee,
onseuraaviendirekivienjastandardienkaikkienasianmukaistensäännösten
mukainen:
Direkivit:
B.
Standardit
A.
Tämäasiakirjanlopussaolevanimijaallekirjoitusovathenkilön,jokavastaasekä
vaamuksenmukaisuusvakuutuksestaeäteknisestäedostosta.
Suomi
FI

TAV 100/150
5
Dichiarazione di conformità
ABPh.Nederman&Co.,dichiarasoolapropriaesclusivaresponsabilitàcheil
prodooNederman:
TAV100/150(Art.N.**,eleversionidideo**)alqualeèrelavalapresente
dichiarazione,èconformealledisposizionidelleseguendireveenormave:
Direve
B.
Normave
A.
Ilnomeelarmaincalcealpresentedocumentoappartengonoalresponsabile
delladichiarazionediconformitàedelladocumentazionetecnica.
Italiano
IT
Déclaraon de conformité
Nous,ABPh.Nederman&Co.,déclaronssousnotreseuleresponsabilitéquele
produitNederman:
TAV100/150(Réf.**,etlesmodèlesbaséssurlesréf.**)auquelfaitréférence
laprésentedéclaraonestenconformitéavectouteslesdisposions
applicablesdesdirecvesetnormessuivantes:
Direcves
B.
Normes
A.
Lenometlasignatureenbasdecedocumentapparennentàlapersonne
responsabledeladéclaraondeconformitéetduchiertechnique.
Français
FR
Conformiteitsverklaring
Wij,ABPh.Nederman&Co,verklareninuitsluitendeaansprakelijkheiddathet
productvanNederman:
TAV100/150(Arkelnr.**,enverklaardeversiesvan**),waaropdeze
verklaringvantoepassingis,inovereenstemmingismetallerelevante
voorschrienvandevolgenderichtlijnenennormen:
Richtlijnen
B.
Normen
EA.
Naamenhandtekeningonderditdocumentzijnvandegenedie
verantwoordelijkisvoorzoweldeVerklaringvanOvereenstemmingalshet
technischedocument.
Nederlands
NL
Samsvarserklæring
Vi,ABPh.Nederman&Co,erklærerpåegetansvaratNedermansprodukt:
TAV100/150(Delnr.**,ogualteversjonerav**)somdenneerklæringen
gjelderfor,erioverensstemmelsemedfølgendedirekverogstandarder:
Direkver
B.
Standarder
A.
Navnetogsignaturenlsluideedokumentetlhørervedkommendesomer
ansvarligforbådesamsvarserklæringenogdentekniskelen.
Norsk
NO
Declaração de conformidade
Nós,ABPh.Nederman&Co.,declaramossobnossainteiraresponsabilidade
queoprodutoNederman:
TAV100/150(Argonº**easversõesdoindicado**),aoqualestadeclaração
serefere,estáemconformidadecomtodasasdisposiçõesrelevantesdas
seguintesdirevasenormas:
Direcvas
B.
Normas
A.
Onomeeaassinaturanonaldestedocumentosãoosdapessoaresponsável
peladeclaraçãodeconformidadeepelocheirotécnico.
Português
PT
Deklaracja zgodności
FirmaABPh.Nederman&Co.niniejszymdeklarujezpełnąodpowiedzialnością,
żeoferowanyprzezniąproduktTAV100/150(nrczęści**ioznaczeniewersji
**),doktóregoodnosisiętadeklaracja,spełniawszystkieodpowiednie
wymaganiaponiższychdyrektywinorm:
Dyrektywy
B.
Normy
A.
Nakońcuniniejszegodokumentuznajdująsięimię,nazwiskoorazpodpisosoby
odpowiedzialnejzadeklaracjęzgodnościorazdokumentacjętechniczną.
Polski
PL

TAV 100/150
6
Försäkran om överensstämmelse
Vi,ABPh.Nederman&Co.,försäkrarunderegetansvaraNederman-
produkten:
TAV100/150(arkelnr**,ochfastställdaversionerav**.),somdennaförsäkran
avser,överensstämmermedallallämpligabestämmelseriföljandedirekvoch
standarder:
Direkv
B.
Standarder
A.
Namnochnamnteckningenislutetavdeadokumentärdenpersonsom
ansvararbådeförförsäkranomöverensstämmelseochfördentekniska
dokumentaonen.
Svenska
SV
ABPh.Nederman&Co.
P.O.Box602
SE-25106Helsingborg
Sweden
LarsNagy
ManagerProductCentre
2016-02-29
**
40146010,40146030,40146040,40146060,40146080,40146081,40146082,40146083,40146100,40146101,40146102,40146103
=
=
TAV100 TAV150
PC EX
MV 24V DC EX
MV 24V AC/DC
MV 115V AC EX
MV 230V AC EX
PC EX
MV 24V DC EX
MV 24V AC/DC
MV 115V AC EX
MV 230V AC EX
B Directive
2006/42/EG
2004/108/EC
2006/95/EC
2014/34/EU
A Standards
EN ISO 12100
EN 13463-5
EN 1127-1

TAV 100/150
7
TAV 100/150 MA
TAV 100/150 PC
Figures
1 2
3 4 5
10
12
9
11
81
2
6
7
3
A
4
B
5

TAV 100/150
8
TAV 100/150 PC
5-port
valve
P
6
TAV 100/150 MA
micro switch
TAV 100/150 MV
pressure switch
P
7 8

TAV 100/150
9
124
217
412
133
136
TAV 100
+Min: 0.5 MPa (5 bar) 70 PSI
Max: 1 MP (10 bar) 145 PSI
50 mm
474
308
199
193
121
TAV 150
10
11
12
9
13

TAV 100/150
10
14
AB
AB
BA
BA
15

TAV 100/150
11

TAV 100/150EN
12
Table of contents
English
UserManual
1 Preface..............................................................................................................................................................................13
2 Safety.................................................................................................................................................................................13
3 Technicaldata...............................................................................................................................................................13
3.1 Productmarking..........................................................................................................................................14
4 Descripon.....................................................................................................................................................................14
5 DescriponATEXproducts....................................................................................................................................14
6 Funcon...........................................................................................................................................................................15
7 Installaon......................................................................................................................................................................16
7.1 Electricalinstallaon.................................................................................................................................16
7.2 Connecons....................................................................................................................................................16
7.3 Direconsforuse........................................................................................................................................17
7.4 Maintenance..................................................................................................................................................17
7.5 ServiceandMaintenanceofATEXequipment...........................................................................18
8 Accessories....................................................................................................................................................................18
8.1 Spareparts......................................................................................................................................................18
8.2 Recycling...........................................................................................................................................................19

TAV 100/150
13
EN
1 Preface
Readthismanualcarefullybeforeinstallaon,useandserviceofthisproduct.
Replacethemanualimmediatelyiflost.Nedermanreservestheright,without
previousnoce,tomodifyandimproveitsproductsincludingdocumentaon.
ThisproductisdesignedtomeettherequirementsofrelevantECdirecves.To
maintainthisstatus,allinstallaon,maintenanceandrepairistobedoneby
qualiedpersonnelusingonlyNedermanoriginalsparepartsandaccessories.
ContactthenearestauthorizeddistributororNedermanforadviceon
technicalserviceandobtainingspareparts.Ifthereareanydamagedor
missingpartswhentheproductisdelivered,nofythecarrierandthelocal
Nedermanrepresentaveimmediately.
2 Safety
Thisdocumentcontainsimportantinformaonthatispresentedeitherasa
warning,cauonornote.Seethefollowingexamples:
WARNING! Risk of personal injury.
Warningsindicateapotenalhazardtothehealthandsafetyofpersonnel,
andhowthathazardmaybeavoided.
CAUTION! Risk of equipment damage.
Cauonsindicateapotenalhazardtotheproductbutnottopersonnel,and
howthathazardmaybeavoided.
NOTE! Notescontainotherinformaonthatisimportantforpersonnel.
3 Technical data
Table3-1:Dimensions
Item Dimension
Maximumpressure 1MPa(10bar)
Minimumpressure(forsafeoperaon) 0,5MPa(5bar)
Recommendedpressure 0,6-0,7MPa(6-7bar)
Airquality ISO8573-1class5
Workingtemperature 0–40ºC
Wiringgauge minimum0,75mm2
Solenoidvoltages 115VAC(+10%-15%)
230VAC(+10%-15%)
24VDC(+-10%)or
24VAC/DC(notATEX)
Frequency 50/60HzforAC
Equipmenttype II3DcT=130ºC
(ATEX-products)

TAV 100/150EN
14
3.1 Product marking
ThefollowingproductsarenotATEX-classiedandareonlymarkedwiththe
CElabel:
TAV100/150MA(seeDescriponATEX-products)
TAV100/150MV24VAC/DC
ThefollowingproductsareATEX-classiedandaremarkedaccordingtothe
descripon:
TAV100/150PC
TAV100/150MV115VAC,230VAC,24VDC
II3DcT=130ºC
EXlabelaccordingtoEuropeanCommisionforEXproducts
Table3-2:Markingexplanaon
Item Descripon
II Equipmentgroup(nonmining)
3 Equipmentcategory3,exterioroftheproduct
DDust
T=130ºC Maximumsurfacetemperature
cconstruconalsafetyaccordingto13463-5
4 Descripon
TAV100/150isavalveforautomacopeningandclosingofavacuumoutlet
linkedtoacentralvacuumsystem.Itcomesinsixdierentmodels.Thevalves
arenormallyautomac,theyopenandclosegovernedbyacontroldevice.
Thecontroldevicecanbeasolenoidvalveforelectriccontrol.TAV100/150PC
isnotedwithitsowncontroldevicebutanexternal5-portvalveisavailable
asanopon(seegure6).Allversionsarecompressedairpoweredexceptfor
MAwhichismanuallyoperated.
Allvalvescanbeprovidedwithanoponalpilotswitchtocontrolthe
vacuumunitsoitstopsifnovalveisopenandthenstartsagainwhenavalve
opens.Thisrequiresapilotsignalcableandavacuumunitprovidedwithan
automacstart/stopfuncon.Manualvalvesuseamicroswitchaccording
togure4and7.Pneumacallycontrolledvalvesuseapressure-controlled
switchaccordingtogure5and8.
5 Descripon ATEX products
AllversionsofTAV100/150aremarkedwiththeCElabel.Dependingon
modelandpurposeofuse,someTAV100/150alsohavetheEXsymboland
categorymarking.AllTAV100/150markedwiththeEXsymbolarecategory
3Dequipmentaccordingtodirecve2014/34/EU.Thismeansthatmodels
withtheEXsymbolmaybeplacedinareasclassiedaszone22accordingto
direcve1999/92/EC.
ThemanuallyoperatedTAV100/150MAisnotmarkedwiththeEXsymbolas
manuallyoperatedequipmentdoesnotfallunderthescopeofthedirecve
2014/34/EU.EveniftheTAV100/150MAdoesnothavetheEXmarking,itis

TAV 100/150
15
EN
highlysuitableforuseinareasclassiedaszone22andsharethesamehigh
levelofproteconastheTAV100/150withEXmarking.
PleasenotethatTAV100/150MV24VAC/DCdoesnothavetheEXmarking
andmaynotbeinstalledinclassiedareas.
Category limit
ThefunconoftheTAV100/150istobeapartofanextraconpipingsystem.
EveniftheTAV100/150withEXsymboliscategory3Dequipmentforusein
zone22(TAV100/150exterior),itcanbeusedwithpipingsysteminternally
classiedaszone20or21.
AsthereisnointernalignionsourceinsidetheTAV100/150,itistobe
consideredassimplepipinganddoesnotfallunderthescopeofthedirecve
2014/34/EU.
Permied materials
TheTAV100/150isonlyintendedtobeapartofanextraconsystem
transporngdustswiththefollowingproperes:MIE(MinimumIgnion
Energy)>3mJandMIT(MinimumIgnionTemperature)>205ºC.Donot
extractitemsthatmaycauseignionorblocking.
Main components
Figure3showsaTAV100/150MV.MVindicatesthatthecontroldeviceisa
solenoidvalve.Figures4-5showtwodierenttypesofpilotswitches,micro
switchAandpressure-controlledswitchB.
1. Housing
2. Sealingstrip
3. Stainlesssteelvalvedisc
4. Nylonsealingring
5. Chloropreneback-upring
6. Arm
7. Cylinder
8. Solenoidvalve
9. Pneumacpush-innipple.(Pushtheringtoreleasethehose.)
10. Electricconnecon
11. Restrictorvalvetosetthespeedofthevalvediscwhenopening(NC
valve)
12. Restrictorvalvetosetthespeedofthevalvediscwhenclosing(NCvalve)
6 Funcon
Thedescriponreferstogure3.Whenthevalvedisc(item3)isturned
clockwisetoitslimit,theholeinthediscwillbeinlinewiththeinlet/outlet
musandthevalveisthusopen.Attheanclockwiselimitthevalvedisc
blockstheborebetweentheinlet/outletmusandthevalveisthusclosed.
Themanualversion,TAV100/150MA,requiresnocompressedairbutis
equippedwithaleverforoperaonofthevalve.
Thesealingringsandback-upringssealagainstthedisc.Theback-upringsare
madeofchloroprene.

TAV 100/150EN
16
7 Installaon
Fitthevalve”inline”inthevacuumpipe(gure6)ordirectontheequipment
thatitistoserve.Conducngjointsleevesforpipeworkaretobeused.
CAUTION! Risk of equipment damage.
Thevalvemustnotbaretheloadofconneconpipesorotherconnecons
whichmaycausedefectsonthevalve.Makesuretheconneconsarermly
installedagainstthewall,ceiling,oororsuchlike.Hoseconneconsmustbe
strainreliefed.
Thecompressedairpipesmustbeblowncleanbeforengthevalve,
gure11.Newcompressedairpipesalwayscontaindirt,whichcouldcause
operaonaldisturbance.Wearearproteconandsafetygoggles.Amoisture
anddirttrapmustbeinstalledifcompressedairisofpoorquality.Anoilmist
lubricangdeviceisnotrequired.
7.1 Electrical installaon
Toensureproperfunconandrequiredlevelofproteconwithregardstothe
equipmentcategory,makesurethatthefollowingpointsarechecked:
•Electricalinstallaonandconneconofthemagnecvalvemustbedone
byaceredelectrician.Aceredelectricianmustalsopayaenonto
thecondionsforinstallaonsinzonesclassiedaccordingtoATEX.
•Checkthatpropermeasureshavebeentakentoavoidalltypesof
electricalstraycurrentstoand/orfromthepipingsystemandelectrical
wiring.NotethattheTAV100/150housingmustbeproperlygrounded.
•ConnectedhosesorpipingmustbeconducveandgroundedtotheTAV
100/150studs(seegure12-15).
•Checkthatthecorrectvoltageisconnectedtothesolenoidofthe
magnecvalve.Checkthemarkingonthesolenoid.
•Electricalopons,likemicroswitches,mustbeconnectedtoanintrinsic
safecircuit(foroponsinstalledinATEXclassiedzones).
7.2 Connecons
WARNING! Risk of personal injury.
• Maximumrecommendedairpressureis1MPa(10bars).Apressure
regulatormustbeinstalledifthepressureislikelytoexceedthemaximum
pressure.Recommendedworkingpressureis0,6-0,7MPa(6-7bars).Min.
pressureforareliablefunconis0.5MPa(5bars).
• Compressedairhosesmustbeapprovedfortheactualpressureandmust
besecurelyfastenedtothevalvenipples.Hoseclipsmustbeedcorrectly.
• Thevalveisdesignedforvacuum,ie,itshouldonlybeinstalledinsystems
workingwithnegavepressurecomparedtoatmosphere.
Figures6-8explainhowtoconnectTAVvalveshavingdierentcontrol
devices.A“asharrow”indicatesanelectricsupply.Pindicatesacompressed
airsupply.
•TAV100/150PC(gure6)isnotedwithitsowncontroldevice.Itis
intendedfordirectcontrolwitharemote3-portpilotvalve(opon).
•TAV100/150MA(gure7)iscontrolledbyahandoperatedlever.Itis
usedwhenthereisnoneedforautomaccontrolling.

TAV 100/150
17
EN
•TAV100/150MV(gure8)hasasolenoidvalvecontroldevice.The
solenoidvoltagemustmatchthesignalvoltage.Standardvoltageis24,
42,230VACand24VDC.Thepoweris5VAor5W.
TAV100/150MVcanbedirectlycontrolledbyastaonaryelectricmachine.
However,extrabranchfusesshouldbeusedifthemainsfusesaretoolargefor
thisfuncon.Seeratedvoltageandpoweronthesolenoid.
7.3 Direcons for use
WARNING! Risk of personal injury.
• Keepngersclearothevacuumconneconswhenthevalveisconnected
tocompressedair.Thespringthatclosesthevalveisstrongenoughtocause
discomfort.
• Makesurethesystemdoesnottransportmaterialwhichcandamagethe
TAVvalve.
• Ifanunexpectedobjectcomesintothesystem,shutthecompressedair
supplytothevalveimmediatellyandremovetheobject.
• Thevalvemustnotbeputintoserviceunlthevalveinletandoutletare
connectedtoxedpipesorhosesthatareatleast1metrelong.
7.4 Maintenance
Forserviceandtechnicalsupport,pleasecontactABPh.Nederman&Co.
WARNING! Risk of personal injury.
• Disconnectvoltagepriortoservice.
• Thecompressedairsupplymustbedisconnectedandanyremaining
pressureinthevalveandpneumaccylindersdischargedbefore
commencinganymaintenanceworktothevalve.Ashutovalvebefore
eachTAVvalveisrecommended.
•ThecompressedairsupplytotheTAVvalvemustbedryandclean
(accordingtostandardISO8573-1class5).Dirtmayresultinmalfuncon
bycloggingthecontroldeviceandtherestrictorvalves.Installinganair
ltermaybenecessaryifcloggingoccurs.
•Makesuretheinsideofthevalveandtheconneconpipesarefree
fromdeposits.Buildupofdepositsinsidethepipingsystemmaycause
dischargeofstacelectricity.
•MakesuretheoutsideoftheTAVvalve,andparcularlythesolenoid,are
freefromdustlayers.
•Oilyandsckysubstancescansomemesscktothevalveblade
resulnginjammingsothatthevalvedoesnotclosecompletely.The
valvemustthenbedismantledforcleaning.
•Thebackupringsofchloropreneareresistanttomostsubstancesin
reasonablequanes.Oilinalargequantycancauseswellingtothe
ringsresulnginjamming.Inextremesituaonsitmayprovenecessary
tochangetovitonrings,whichareresistanttomostsubstances.Please
consultthesparepartlist.
•Aerafewthousandoperaonsthesealingringsandtheback-uprings
shouldbeexchangedinordertoavoidleakage

TAV 100/150EN
18
7.5 Service and Maintenance of ATEX equipment
Toensuretherequiredlevelofproteconwithregardstotheequipment
category,checkthefollowingpoints:
•EnsurethattheTAVvalveisregularlyinspectedfordamageor
malfuncon.Ifthevalveisdamageditmustbereplacedorremoved
immediatelyfromtheclassiedarea.
•Ensurethatnoexplosiveatmosphereand/ordustlayersarepresent
whencleaning,servicingorinspecngtheTAVvalve.
•Ensurethatonlyoriginal(OEM)sparepartsareused.
•EnsurethattheTAVvalveisnotcoveredwiththickdustlayers(>5mm).
Thisispreventedbysenguprounesforregularcleaningandincluding
theseintheexplosionprotecondocument.
8 Accessories
1. AS-setwithmicroswitchandconneconboxforthepilotsignal.The
switchcontrolsthevacuumplanttomakeitstopwhenallvalvesare
closedandmakeitstartagainassoonasavalveisopened.Apilotsignal
cableanasuitablemotorstarterarerequiredtoexecutethisfuncon.
FingoftheAS-setisshowningure4andisalsoshownschemacally
ingures7.Partno.40141550
2. Transformer,230/24VAC,60VAinaplascenclosure.Canfeed12
solenoidvalves.SuitableforTAV100/150MV24VAC/DC.Partno.
40750100
3. 5-portvalveforremotecontrolofTAV100/150PC(withoutcontrol
deviceofitsown).Seegure6.Canbelocated20mfromTAV100/150.
Partno.40680250
4. Pressure-controlledswitch.Theswitchcontrolsthevacuumplantto
makeitstopwhenallvalvesareclosedandmakeitstartagainassoon
asavalveisopened.Apilotsignalcableanasuitablemotorstarterare
requiredtoexecutethisfuncon.Fingoftheswitchisshowningure5
andisalsoshownschemacallyingure8.Partno.40141780
Accessories in classied locaons (ATEX)
Allelectricallyconnectedaccessoriesmustbeinstalledaccordingtoapplicable
regulaonsforEXproducts.ThismeansthatTAVaccessoriesinstalledinsideof
aclassiedarea(i.e.zone22)mustbeconnectedtoaninstrinsicsafecircuit.
Pneumacaccessorieswithoutanysourceofignionarenotincludedinthis
requirement.PleasecontactTechnicalSupport,ABPh.Nederman&Co.for
detailedinformaonregardinginstallaonofTAVaccessoriesinclassied
areas.
8.1 Spare parts
CAUTION! Risk of equipment damage.
UseonlyNedermanoriginalsparepartsandaccessories.
ContactyournearestauthorizeddistributororNedermanforadvice
ontechnicalserviceorifyourequirehelpwithspareparts.Seealso
www.nederman.com.

TAV 100/150
19
EN
Ordering spare parts
Whenorderingsparepartsalwaysstatethefollowing:
•Partnumberandcontrolnumber(seetheproductidencaonplate).
•Detailnumberandnameofthesparepart(seewww.nederman.com).
•Quantyofthepartsrequired.
8.2 Recycling
Theproducthasbeendesignedforcomponentmaterialstoberecycled.
Itsdierentmaterialtypesmustbehandledaccordingtorelevantlocal
regulaons.ContactthedistributororNedermanifuncertainesarisewhen
scrappingtheproductattheendofitsservicelife.

TAV100/150CS
20
Český
Návod k obsluze
1 Úvod ................................................................................................................................................................ 21
2 Upozornění na rizika ............................................................................................................................... 21
3 Technická data........................................................................................................................................... 21
3.1 Označení výrobku ...................................................................................................................... 22
4 Popis................................................................................................................................................................ 22
5 Popis výrobků podle směrnic ATEX................................................................................................ 22
6 Funkce............................................................................................................................................................ 23
7 Instalace........................................................................................................................................................ 23
7.1 Elektroinstalace........................................................................................................................... 24
7.2 Připojení........................................................................................................................................... 24
7.3 Návod k použití............................................................................................................................ 25
7.4 Údržba.............................................................................................................................................. 25
7.5 Servis a údržba zařízení podle směrnic ATEX ............................................................ 25
8 Příslušenství................................................................................................................................................ 26
8.1 Náhradní díly................................................................................................................................. 26
9 Recyklace..................................................................................................................................................... 26
Obsah
Other manuals for TAV 100
1
This manual suits for next models
1
Table of contents
Languages:
Other Nederman Control Unit manuals
Popular Control Unit manuals by other brands

Siemens
Siemens FCI1802-A2 product manual

Emerson
Emerson Fisher 63EGLP Series instruction manual

Dranetz-BMI
Dranetz-BMI EPQ DataNode Series user guide

Burkert
Burkert 2712 Series operating instructions

Carrier
Carrier INFINITY SYSTXCCITC01 owner's manual

Lutron Electronics
Lutron Electronics Maestro Wireless MRF2-3PD-1 manual

Nidec
Nidec SM-Applications Series user guide

Steamist
Steamist TSC-250T Installation and operating instructions

Motorola
Motorola MVME2300SC Series Installation and use

Fanstel
Fanstel BlueFan BT680E manual

Polycom
Polycom SoundPoint IP 670 quick start guide

Siemens
Siemens 3VM9.88-0LB10 operating instructions