Nederman TAV 50 Series User manual

Valves and accessories
Vacuum Valve TAV 50
2130293(01)
2019-11-29
Original instrucon manual
EN INSTRUCTION MANUAL
Translaon of original instrucon manual
CS NÁVOD K OBSLUZE
DA BETJENINGSVEJLEDNING
DE BEDIENUNGSANLEITUNG
ES MANUAL DE INSTRUCCIONES
FI KÄYTTÖOHJEET
FR MANUEL D’INSTRUCTION
HU FELHASZNÁLÓI KÉZIKÖNYV
IT MANUALE D’ISTRUZIONE
NL HANDLEIDING
NO BRUKSANVISNING
PL INSTRUKCJA UŻYTKOWANIA
PT MANUAL DE INSTRUÇÕES
RU РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
SK NÁVODNAOBSLUHU
SV ANVÄNDARMANUAL
Instruconmanual

Vacuum Valve TAV 50
2

Vacuum Valve TAV 50
3
Declaration of conformity................................................................................4
Figures......................................................................................................................................................8
English..................................................................................................................................................15
Český...................................................................................................................................................... 25
Dansk...................................................................................................................................................... 35
Deutch.................................................................................................................................................. 45
Español.............................................................................................................................................. 55
Suomi..................................................................................................................................................... 65
Français............................................................................................................................................. 75
Magyar ................................................................................................................................................. 85
Italiano ................................................................................................................................................. 95
Nederlands.............................................................................................................................105
Norsk....................................................................................................................................................117
Polski...................................................................................................................................................127
Português.................................................................................................................................. 137
Русский........................................................................................................................................149
Slovensky.................................................................................................................................. 161
Svenska......................................................................................................................................... 171

Vacuum Valve TAV 50
4
Declaraon of conformity
Declaraon of conformity
We, AB Ph. Nederman & Co., declare under our sole responsibility that the
Nederman product:
Vacuum Valve TAV 50 (Part No. **, and stated versions of **) to which this
declaraon relates, is in conformity with all the relevant provisions of the
following direcves and standards:
Direcves
2006/42/EC, 2014/30/EU, 2014/34/EU.
Standards
EN ISO 12100:2010, EN 60204-1:2006, EN 60204-1:2006/A1:2009, EN 1127-
1:2011, EN 60079-0:2012, EN ISO 80079-36:2016, EN ISO 80079-37:2016.
The name and signature at the end of this document, is the person responsible
for both the declaraon of conformity and the technical le.
English
EN
Konformitätserklärung
Wir, AB Ph. Nederman & Co., erklären in alleiniger Verantwortung, dass das
Nederman Produkt
Vacuum Valve TAV 50 (Art.-Nr. **, und bauartgleiche Versionen **), auf welches
sich diese Erklärung bezieht, mit allen einschlägigen Besmmungen der
folgenden Richtlinien und Normen übereinsmmt:
Richtlinien
2006/42/EC, 2014/30/EU, 2014/34/EU
Normen
EN ISO 12100:2010, EN 60204-1:2006, EN 60204-1:2006/A1:2009, EN 1127-
1:2011, EN 60079-0:2012, EN ISO 80079-36:2016, EN ISO 80079-37:2016.
Name und Unterschri am Dokumentende geben diejenige Person an, die für
die Konformitätserklärung und die technische Dokumentaon verantwortlich ist.
Deutsch
DE
Overensstemmelseserklæring
AB Ph. Nederman & Co. erklærer som eneansvarlige, at følgende produkt fra
Nederman:
Vacuum Valve TAV 50 (Arkel nr. **, og erklærede versioner af **), som denne
erklæring vedrører, er i overensstemmelse med alle de relevante bestemmelser
i de følgende direkver og standarder:
Direkver
2006/42/EC, 2014/30/EU, 2014/34/EU.
Standarder
EN ISO 12100:2010, EN 60204-1:2006, EN 60204-1:2006/A1:2009, EN 1127-
1:2011, EN 60079-0:2012, EN ISO 80079-36:2016, EN ISO 80079-37:2016.
Navnet og underskrien sidst i dee dokument lhører den person, der
er ansvarlig for såvel overensstemmelseserklæringen som den tekniske
dokumentaon.
Dansk
DA
Declaración de Conformidad
Nosotros, AB Ph. Nederman & Co., declaramos bajo nuestra única
responsabilidad que el producto Nederman:
El producto, Vacuum Valve TAV 50 (Ref. nº **, y las versiones basadas **),,
al que hace referencia esta declaración, cumple con todas las disposiciones
aplicables de las Direcvas y normas que se indican a connuación:
Direcvas
2006/42/EC, 2014/30/EU, 2014/34/EU.
Normas
EN ISO 12100:2010, EN 60204-1:2006, EN 60204-1:2006/A1:2009, EN 1127-
1:2011, EN 60079-0:2012, EN ISO 80079-36:2016, EN ISO 80079-37:2016.
El nombre y rma que guran al nal de este documento corresponden a la
persona responsable, tanto de la declaración como de la cha técnica.
Español
ES
Prohlášení o shodě
My, společnost AB Ph. Nederman & Co., prohlašujeme na svou zodpovědnost, že
výrobek Nederman:
Vacuum Valve TAV 50 (díl č. **, a uvedla, verze **), ke kterému se toto
prohlášení vztahuje, je v souladu se všemi příslušnými ustanoveními
následujících směrnic a norem:
Směrnice
2006/42/EC, 2014/30/EU, 2014/34/EU.
Normy
EN ISO 12100:2010, EN 60204-1:2006, EN 60204-1:2006/A1:2009, EN 1127-
1:2011, EN 60079-0:2012, EN ISO 80079-36:2016, EN ISO 80079-37:2016.
Na konci tohoto dokumentu je jméno a podpis osoby zodpovědné za prohlášení
o shodě a soubor technické dokumentace.
Češna
CS
Vaamustenmukaisuusvakuutus
Me, AB Ph. Nederman & Co., vakuutamme yksinomaan omalla vastuullamme,
eä Nederman-tuote
Vacuum Valve TAV 50 (tuotenro **, ja totesi versioita **), jota tämä vakuutus
koskee, on seuraavien direkivien ja standardien kaikkien asianmukaisten
säännösten mukainen:
Direkivit:
2006/42/EC, 2014/30/EU, 2014/34/EU.
Standardit
EN ISO 12100:2010, EN 60204-1:2006, EN 60204-1:2006/A1:2009, EN 1127-
1:2011, EN 60079-0:2012, EN ISO 80079-36:2016, EN ISO 80079-37:2016.
Tämä asiakirjan lopussa oleva nimi ja allekirjoitus ovat henkilön, joka vastaa sekä
vaamuksenmukaisuusvakuutuksesta eä teknisestä edostosta.
Suomi
FI

Vacuum Valve TAV 50
5
Declaração de conformidade
Nós, AB Ph. Nederman & Co., declaramos sob nossa inteira responsabilidade
que o produto Nederman:
Vacuum Valve TAV 50 (Argo nº ** e as versões do indicado **), ao qual esta
declaração se refere, está em conformidade com todas as disposições relevantes
das seguintes direvas e normas:
Direcvas
2006/42/EC, 2014/30/EU, 2014/34/EU.
Normas
EN ISO 12100:2010, EN 60204-1:2006, EN 60204-1:2006/A1:2009, EN 1127-
1:2011, EN 60079-0:2012, EN ISO 80079-36:2016, EN ISO 80079-37:2016.
O nome e a assinatura no nal deste documento são os da pessoa responsável
pela declaração de conformidade e pelo cheiro técnico.
Português
PT
Deklaracja zgodności
Firma AB Ph. Nederman & Co. niniejszym deklaruje z pełną odpowiedzialnością,
że oferowany przez nią produkt Vacuum Valve TAV 50 (nr części ** i oznaczenie
wersji **), do którego odnosi się ta deklaracja, spełnia wszystkie odpowiednie
wymagania poniższych dyrektyw i norm:
Dyrektywy
2006/42/EC, 2014/30/EU, 2014/34/EU.
Normy
EN ISO 12100:2010, EN 60204-1:2006, EN 60204-1:2006/A1:2009, EN 1127-
1:2011, EN 60079-0:2012, EN ISO 80079-36:2016, EN ISO 80079-37:2016.
Na końcu niniejszego dokumentu znajdują się imię, nazwisko oraz podpis osoby
odpowiedzialnej za deklarację zgodności oraz dokumentację techniczną.
Polski
PL
Conformiteitsverklaring
Wij, AB Ph. Nederman & Co, verklaren in uitsluitende aansprakelijkheid dat het
product van Nederman:
Vacuum Valve TAV 50 (Arkelnr. **, en verklaarde versies van **), waarop
deze verklaring van toepassing is, in overeenstemming is met alle relevante
voorschrien van de volgende richtlijnen en normen:
Richtlijnen
2006/42/EC, 2014/30/EU, 2014/34/EU.
Normen
EEN ISO 12100:2010, EN 60204-1:2006, EN 60204-1:2006/A1:2009, EN 1127-
1:2011, EN 60079-0:2012, EN ISO 80079-36:2016, EN ISO 80079-37:2016.
Naam en handtekening onder dit document zijn van degene die
verantwoordelijk is voor zowel de Verklaring van Overeenstemming als het
technische document.
Nederlands
NL
Samsvarserklæring
Vi, AB Ph. Nederman & Co, erklærer på eget ansvar at Nedermans produkt:
Vacuum Valve TAV 50 (Del nr. **, og ualte versjoner av **) som denne
erklæringen gjelder for, er i overensstemmelse med følgende direkver og
standarder:
Direkver
2006/42/EC, 2014/30/EU, 2014/34/EU.
Standarder
EN ISO 12100:2010, EN 60204-1:2006, EN 60204-1:2006/A1:2009, EN 1127-
1:2011, EN 60079-0:2012, EN ISO 80079-36:2016, EN ISO 80079-37:2016.
Navnet og signaturen l slu i dee dokumentet lhører vedkommende som er
ansvarlig for både samsvarserklæringen og den tekniske len.
Norsk
NO
Dichiarazione di conformità
AB Ph. Nederman & Co., dichiara soo la propria esclusiva responsabilità che il
prodoo Nederman:
Vacuum Valve TAV 50 (Art. N. **, e le versioni di deo **) al quale è relava la
presente dichiarazione, è conforme alle disposizioni delle seguen direve e
normave:
Direve
2006/42/EC, 2014/30/EU, 2014/34/EU.
Normave
EN ISO 12100:2010, EN 60204-1:2006, EN 60204-1:2006/A1:2009, EN 1127-
1:2011, EN 60079-0:2012, EN ISO 80079-36:2016, EN ISO 80079-37:2016.
Il nome e la rma in calce al presente documento appartengono al responsabile
della dichiarazione di conformità e della documentazione tecnica.
Italiano
IT
Megfelelőségi nyilatkozat
Az AB Ph. Nederman & Co. vállalat teljes felelőssége tudatában kijelen, hogy
a(z)
Vacuum Valve TAV 50 (cikkszám: **, és módosíto verziói **) termék, amelyre
ez a nyilatkozat vonatkozik, megfelel az alábbi irányelveknek és szabványoknak:
Irányelvek:
2006/42/EC, 2014/30/EU, 2014/34/EU.
Szabványok:
EN ISO 12100:2010, EN 60204-1:2006, EN 60204-1:2006/A1:2009, EN 1127-
1:2011, EN 60079-0:2012, EN ISO 80079-36:2016, EN ISO 80079-37:2016.
A dokumentum végén található név és aláírás a megfelelőségi nyilatkozatért és a
műszaki dokumentációért felelős személy neve és aláírása.
Magyar
HU
Déclaraon de conformité
Nous, AB Ph. Nederman & Co., déclarons sous notre seule responsabilité que le
produit Nederman :
Vacuum Valve TAV 50 (Réf. **, et les modèles basés sur les réf. **) auquel fait
référence la présente déclaraon est en conformité avec toutes les disposions
applicables des direcves et normes suivantes :
Direcves
2006/42/EC, 2014/30/EU, 2014/34/EU.
Normes
EN ISO 12100:2010, EN 60204-1:2006, EN 60204-1:2006/A1:2009, EN 1127-
1:2011, EN 60079-0:2012, EN ISO 80079-36:2016, EN ISO 80079-37:2016.
Le nom et la signature en bas de ce document apparennent à la personne
responsable de la déclaraon de conformité et du chier technique.
Français
FR
Декларация о соответствии
Компания AB Ph. Nederman & Co. со всей ответственностью заявляет, что
оборудование Nederman:
Vacuum Valve TAV 50 (№ по каталогу **, и заявил, версии **), к которому
относится данная декларация, соответствует всем требуемым положениям
следующих директив и стандартов.
Директивы
2006/42/EC, 2014/30/EU, 2014/34/EU.
Стандарты
EN ISO 12100:2010, EN 60204-1:2006, EN 60204-1:2006/A1:2009, EN 1127-
1:2011, EN 60079-0:2012, EN ISO 80079-36:2016, EN ISO 80079-37:2016.
Сотрудник, поставивший свою подпись под данным документом, отвечает
как за соблюдение декларации о соответствии, так и за достоверность
технических данных.
Русский
RU

Vacuum Valve TAV 50
6
**
40147040, 40060100, 40060110, 40147050, 40147020, 40147030, 40060120, 40147060, 40147071, 40060140, 40147090, 40060130, 40147100, 40147110,
40147120
Försäkran om överensstämmelse
Vi, AB Ph. Nederman & Co., försäkrar under eget ansvar a Nederman-
produkten:
Vacuum Valve TAV 50 (arkelnr **, och fastställda versioner av **.), som denna
försäkran avser, överensstämmer med alla llämpliga bestämmelser i följande
direkv och standarder:
Direkv
2006/42/EC, 2014/30/EU, 2014/34/EU.
Standarder
EN ISO 12100:2010, EN 60204-1:2006, EN 60204-1:2006/A1:2009, EN 1127-
1:2011, EN 60079-0:2012, EN ISO 80079-36:2016, EN ISO 80079-37:2016.
Namn och namnteckningen i slutet av dea dokument är den person som
ansvarar både för försäkran om överensstämmelse och för den tekniska
dokumentaonen.
Svenska
SV
Vyhlásenie o zhode
My, spoločnosť AB Ph. Nederman & Co., vyhlasujeme na svoju výhradnú
zodpovednosť, že výrobok Nederman:
Produkt Vacuum Valve TAV 50 (č. dielu **, a uviedla, verzia **), ktorého sa toto
vyhlásenie týka, je v zhode so všetkými príslušnými ustanoveniami nasledujúcich
smerníc a noriem:
Smernice
2006/42/EC, 2014/30/EU, 2014/34/EU.
Normy
EN 12100, EN 60335-2-69, EN60335-1, EN55014-1, EN55014-2, EN61000-3-2
EN61000-3-3: 2008.
Meno a podpis na záver tohto dokumentu patria osobe zodpovednej za
vyhlásenie o zhode a technickú dokumentáciu.
Slovensky
SK
AB Ph. Nederman & Co.
P.O. Box 602
SE-251 06 Helsingborg
Sweden
Fredrik Hermann
Product Center Manager
Technical Product Management
2019-11-29

Vacuum Valve TAV 50
7

Vacuum Valve TAV 50
8
TAV 50 PC
TAV 50 MV
TAV 50 MV-W
TAV 50 FV/MV
TAV 50 FV
TAV 50 MA
TAV 50 FV/MV-G
+Instruction
Manual
144348
A
TAV 50 MV-G
+Instruction
Manual
144348
A
Figures
Models

Vacuum Valve TAV 50
9
11
2
3
4
5
1
6
10
7 8
9
1
2
5
3
4
1
2
3 4

Vacuum Valve TAV 50
10
5c
5d
5b
5a
5e
+Min: 0.5 MPa (5 bar) 70 PSI
Max: 1 MPa(10 bar) 145 PSI
7d
7b 7c
AB
AB
BA
BA
7a
50 mm
5
6
7

Vacuum Valve TAV 50
11
TAV 50 PC
P
B
C
TAV 50 MA
B
TAV 50 MV
P
TAV 50 MV-G Instruction Manual
144348
B
8
9
10

Vacuum Valve TAV 50
12
TAV 50 MV-W
P
24V AC
B
TAV 50 FV
P
B
TAV 50 FV/MV
P
TAV 50 FV/MV-G Instruction Manual
144348
B
11
12
13

Vacuum Valve TAV 50
13
175
95 195
120
68
25
87.5
12345
ab
14 15
16
17

Vacuum Valve TAV 50
14

Vacuum Valve TAV 50
14

Vacuum Valve TAV 50
15
EN
English
Instrucon manual
1 Product marking ..........................................................................................................................................................16
2 Preface ..............................................................................................................................................................................17
3 Noces ..............................................................................................................................................................................17
4 Descripon .....................................................................................................................................................................17
4.1 Funcon ............................................................................................................................................................17
4.2 ATEX products ...............................................................................................................................................17
4.3 Category limit ................................................................................................................................................18
4.4 Permied materials ...................................................................................................................................18
4.5 Technical data ................................................................................................................................................18
5 Main components ......................................................................................................................................................19
5.1 Funcon ............................................................................................................................................................19
6 Installaon ......................................................................................................................................................................19
6.1 Mounng .........................................................................................................................................................19
6.2 Electrical installaon .................................................................................................................................20
6.3 Connecons ....................................................................................................................................................20
7 Using Vacuum Valve TAV 50 ..................................................................................................................................21
7.1 Direcons for use ........................................................................................................................................21
8 Maintenance .................................................................................................................................................................21
8.1 Service and Maintenance of ATEX equipment ............................................................................22
8.2 Spare parts ......................................................................................................................................................22
9 Flow Sensing Valve .....................................................................................................................................................22
9.1 Technical data ................................................................................................................................................22
9.2 Descripon ......................................................................................................................................................22
9.3 Main components .......................................................................................................................................23
9.4 Funcon ............................................................................................................................................................23
9.5 Connecon ......................................................................................................................................................23
9.6 Maintenance ..................................................................................................................................................23
10 Accessories .....................................................................................................................................................................23
10.1 Accessories in classied locaons (ATEX) ......................................................................................24
11 Recycling ..........................................................................................................................................................................24
Figures ................................................................................................................................................................................. 8
Table of contents

Vacuum Valve TAV 50EN
16
1 Product marking
The following products are not ATEX-classied and are only marked with the CE label:
•TAV 50 MA (see Descripon ATEX-products)
•TAV 50 MV-W
•TAV 50 MV 24V AC/DC
•TAV 50 FV/MV 24V AC/DC
The following products are ATEX-classied and are marked according to the descripon:
•TAV 50 PC
•TAV 50 FV
•TAV 50 MV 115V AC, 230V AC, 24V DC
•TAV 50 FV/MV 115V AC, 230V AC, 24V DC
II 3D Ex h IIIC T130ºC Dc
0ºC≤Ta≤40ºC
Nederman 19.HB06
Part Explanaon
II: Equipment group (non mining)
h: The leer ”h” as specied in EN ISO 80079-36.
IIIC: Equipment of Group III is intended for use in places with an explosive dust atmosphere
other than mines suscepble to redamp.
Equipment of Group III is subdivided according to the nature of the explosive dust
atmosphere for which it is intended.
Group III subdivisions:
• IIIA: suitable for combusble yings;
• IIIB: suitable for combusble yings and non-conducve dust;
• IIIC: suitable for combusble yings, non-conducve dust and conducve dust.
T130ºC The maximum surface temperature in degrees Celsius.
Dc: Equipment protecon level Dc. Same as old 3D marking.
For explosive atmospheres, caused by mixtures of air and combusble dusts, the
equipment does not contain any eecve ignion sources in normal operaon and
expected malfuncons.
0ºC≤Ta≤40ºC Ambient temperature range
Nederman 19.HB06 Cercate number.
Type of Protecon construconal safety “c”
Technical documentaon contains the informaon required to maintain the product safety.

Vacuum Valve TAV 50
17
EN
2 Preface
This manual is for the correct installaon, use and maintenance of this product. Read it carefully
before using this product or carrying out maintenance. Replace the manual immediately if lost.
This product has been designed to meet the requirements of relevant EC direcves. To maintain
this status, all installaon, repair and maintenance work for this product is to be carried out by
qualied personnel using only original spare parts. Contact the nearest authorized distributor or
Nederman for advice on technical service and obtaining spare parts.
Nederman connuously improves its products’ design and eciency through modicaons,
and reserves the right to do so without introducing these improvements to previously supplied
products. Nederman also reserve the right to, without previous noce, modify data and
equipment as well as operang and maintenance instrucons.
3 Noces
This document contains important informaon that is presented either as a warning, cauon or
note. See the following examples:
WARNING! Risk of personal injury.
Warnings indicate a potenal hazard to the health and safety of personnel, and how that hazard
may be avoided.
CAUTION! Risk of equipment damage.
Cauons indicate a potenal hazard to the product but not to personnel, and how that hazard
may be avoided.
NOTE! Notes contain other informaon that is important for personnel.
4 Descripon
4.1 Funcon
TAV 50 is a valve for automac opening and closing of a vacuum outlet linked to a central
vacuum system. It comes in six dierent models, see gure page 8. The valves are normally
automac, they open and close governed by a control device.
The control device can be a solenoid valve for electric control or a ow sensing valve sensing
the ow to a compressed air tool. TAV 50 PC (basic version) is not ed with its own control
device but an external 3-port valve is available as an opon (see page 11). All versions are
compressed air powered except for MA which is manually operated.
TAV 50 can be ed with a micro switch to control the vacuum unit (see accessories in
secon 9. Accessories). The ow sensing valve (FV) is described in secon 8. Flow Sensing Valve.
4.2 ATEX products
All versions of TAV 50 are marked with the CE label.
Depending on model and purpose of use, some TAV 50 also have the EX symbol and category
marking.
All TAV 50 marked with the EX symbol are category 3D equipment according to direcve
2014/34/EU. This means that models with the EX symbol may be placed in areas classied as
zone 22 according to direcve 1999/92/EC.

Vacuum Valve TAV 50EN
18
The manually operated TAV50 MA is not marked with the EX symbol as manually operated
equipment does NOT fall under the scope of the direcve 2014/34/EU. Even if the TAV50 MA
does not have the EX marking, it is highly suitable for use in areas classied as zone 22 and share
the same high level of protecon as the TAV50 with EX marking.
Please note that TAV 50 MV-W and TAV 50 MV 24 V AC/DC does not have the EX marking and
may not be installed is classied areas.
4.3 Category limit
The funcon of the TAV 50 is to be a part of an extracon piping system. Even if the TAV 50
with EX symbol is category 3D equipment for use in zone 22 (TAV 50 exterior), it can be used
with piping system internally classied as zone 20 or 21. As there is no internal ignion source
inside the TAV 50, it is to be considered as simple piping and does not fall under the scope of the
direcve 2014/34/EU.
4.4 Permied materials
The TAV50 is only intended to be a part of an extracon system transporng dusts with the
following properes: MIE (Minimum Ignion Energy) > 3 mJ and MIT (Minimum Ignion
Temperature) > 205 °C. Do not extract items that may cause ignion or blocking.
4.5 Technical data
Table 4-1: Technical data
Maximum pressure 1 MPa (10 bar)
Minimum pressure (for safe operaon) 0.5 MPa (5 bar)
Recommended pressure 0.6–0.7 MPa (6–7 bar)
Maximum air ow (ow valve) 1800 Nl/min.
Minimum air ow (ow valve) 100 Nl/min.
Air quality ISO 8573-1 class 5
Working temperature 0–40 °C
Wiring gauge minimum 0.75 mm2
Solenoid voltages 115 V AC (+10% -15%)
230 V AC (+10% -15%)
24 V DC (+ -10%) or
24 V AC/DC (not ATEX)
Frequency 50 / 60 Hz for AC
Equipment type II 3D Ex h IIIC T130ºC Dc
0ºC≤Ta≤40ºC
Nederman 19.HB06 (ATEX-products)

Vacuum Valve TAV 50
19
EN
5 Main components
Figure 1 shows a seconed TAV 50.
1. Housing, lower part
2. Housing, upper part
3. Valve blade
4. Sealing ring
5. Backup ring
6. Arm
7. Piston
8. Cylinder (integrated in lower part)
9. Return spring
10. Connecon nipple
11. Micro switch holder
Figure 2 shows the most common control devices.
1. 3-port valve for remote control of TAV 50 PC in basic version
2. Lever (MA)
3. Flow sensing valve (FV)
4. Solenoid valve (MV)
5. Sensor ring, solenoid valve and connecon box (Part of MV-W)
5.1 Funcon
Figure 3 shows TAV 50 in the open posion. Compressed air turns the blade when an air signal is
applied to the connecon nipple. Figure 4 shows the closed posion. The return spring turns the
blade back to this posion as soon as the air signal is removed.
The manual version, TAV 50 MA, requires no compressed air but is equipped with a lever for
operaon of the valve.
The nylon sealing rings supported by the backup rings seal o against the blade in the open
and closed posions. The backup rings are made of neoprene but are also available in viton for
extremely dicult applicaons.
6 Installaon
6.1 Mounng
For wall mounng, posioning as per gure 5a is recommended. Flow direcon is normally
upwards but reverse direcon is also possible. Mounng shown in 5b is also possible but
posioning “up side down” (5c) should be avoided. Supplied support brackets should always be
used for wall mounng, see arrows in gure 5d.
CAUTION! Risk of equipment damage.
The valve must not bare the load of connecon pipes or other connecons which may cause
defects on the valve. Make sure the connecons are rmly installed against the wall, ceiling,
oor or suchlike. Hose connecons must be strain reliefed.
Mounng in a type SA swing arm is made as shown in gure 5e using threaded holes in the
swing arm bracket. The support brackets should not be used in this case.
This manual suits for next models
23
Table of contents
Languages: