Neomitis TMR7 User manual

TMR7
7 DAY SINGLE CHANNEL DIGITAL TIMER
Pack contains ............................................................................................1
Installaon ................................................................................................1
Mounngofwallmoungplate .......................................................................................1
Wiring ...............................................................................................................................1
Mounngofthemer.......................................................................................................2
Installer sengs ........................................................................................2
Advancedinstallerseng .................................................................................................2
Technical specicaons .............................................................................3
TMR7 NEO ENG CP V08 06 04 2021 1
INSTALLATION INSTRUCTIONS
TMR7a
x2
Screw Anchor
x2
Screws
The digital mer is xed on the wall with the wall plate which is supplied with the
product.
MOUNTING OF WALL MOUTING PLATE
PACK CONTAINS
INSTALLATION
x1
Standard wall plate
x1
Timer
WIRING
All wiring must be in accordance with IEE regulaons. This product is for xed wiring
only.
All electrical installaon work should be carried out by a suitably qualied
Electrician or other competent person. If you are not sure how to install
this mer consult either with a qualied electrician or heang Engineer.
Do not remove or ret the appliance onto the backplate without the mains
supply to the system being isolated.
2- Remove the wall plate from the mer.
1- Unscrew the 2 screws under the mer.
x2
3- Secure the wall plate with the two
screws provided using the horizontal
and vercal holes.
4- In case of surface mounng, a knock
out area is provided on the wall plate
and on the corresponding area of the
mer.

2
• Access
• Wiring diagrams
Standard Connecon to Combi Boiler
(with Service shut-down if enabled of heang only)
Connecon to Combi Boiler
(with Service shut-down if enabled of both heang & hot water)
ADVANCED INSTALLER SETTING
INSTALLER SETTINGS
MOUNTING OF THE TIMER
1- Replace the mer on the wall moun-
ng plate.
2- Secure the mer by screwing both
locking screws under the mer.
x2
Seng number Descripon
1 Select gravity/pumped mode (not used)
2 Set 12 or 24 hours clock
3 Acvaon of auto Summer/Winter change over
4 Set the number of ON/OFF periods
5 Select your system between Z1or CH
6
Acvaon of backlight
Press simultaneously and for 5 seconds.
5 advanced sengs can be modied.
Press unl correct opon is in display then use or to select your choice.
5 sec.
• Gravity/Pumped mode (1 - not used)
The pre-set system is Pumped.
2- Then save by moving the programming
slider or save and go to next seng by
pressing .
1- Press or to change to Gravity (2).
1 = Pumped
2 = Gravity
Move the mode slider to o posion. Move the programming slider to
posion.
N
N
L
L1234
Clock
220V-240V~
50Hz
Load
Input
Switched
Load
Output
3 AMPS MAX
N
N
L
L1234
Clock
220V-240V~
50Hz
Load
Input
Mains
In
Switched
Load
Output
Live
to
Boiler
3 AMPS MAX
N = Neutral IN
L = Live IN
1 = Voltage free contact Feed IN 1
2 = Voltage free contact Feed IN 2
3 = Voltage free contact N.O. switching.
out 1
4 = Voltage free contact N.O. switching
out 2
• Internal wiring
N L 1 2 3 4
Clock
LN
220V-240V~
50Hz
3A
max
Note: for 230V switching, insert link between L and 2.

3
• Set 12/24 hours clock (2)
The pre-set value is 12 hours clock.
2- Then save by moving the programming
slider or save and go to next seng by
pressing .
1- Press or to change to "24h".
• Auto Summer/Winter change over (3)
The auto Summer/Winter change over default is ON.
2- Then save by moving the programming
slider or save and go to next seng by
pressing .
1- Press or to change to OFF
• Installaon operang (5)
The digital mer can manage Central Heang or 1 zone.
The pre-set choice is CH.
Note regarding the Advanced installer sengs: If programming slider is moved, it will
save changes and exit installer mode.
2- Then save by moving the programming
slider or save and go to next seng by
pressing .
1- Press or to change to Z1.
• Set number of ON/OFF periods (4)
You can adjust the number of ON/OFF switching me periods. The pre-set number is 2.
1- Press or to change to 3 periods. 2- Then save by moving the programming
slider or save and go to next seng by
pressing .
TECHNICAL SPECIFICATIONS
- Power supply: 220V-240V/50Hz.
- Output per relay: 3(2)A, 12V-240V~.
- Rated impulse voltage: 4000V.
- Micro disconnecon: Type 1B.
- Polluon degree: 2.
- Automac acon: 100,000 cycles.
- Class II.
Environment:
- Operaon temperature: 0°C to +40°C.
- Storage temperature: from -20°C to +60°C.
- Humidity: 80% at +25°C (without condensaon)
- Protecon rang: IP30.
• Backlight (6)
The backlight can be switched O. The pre-set value is ON.
2- 2. Then save by moving the program-
ming slider or save and go to next
seng by pressing .
1- Press or to change to OFF.
The symbol , axed on the product indicates that you must dispose of it at the end
of its useful life at a special recycling point, in accordance with European Direcve WEEE
2012/19/EU. If you are replacing it, you can also return it to the retailer from which you
buy the replacement equipment. Thus, it is not ordinary household waste. Recycling
products enables us to protect the environment and to use less natural resources.
UKCA declaraon of conformity: We, Neomis Ltd, hereby declare under
our sole responsibility that the products described in these instrucons
comply with statutory instruments 2016 No.1101 (Electrical Equipment
safety Regulaons), ), 2016 No.1091 (Electromagnec Compability
Regulaons) , 2012 n°3032 (ROHS) and following designated standards:
- 2016 No.1101 (Safety): EN 60730-1:2011, EN 60730-2-7:2010/
AC:2011, EN 60730-2-9:2010, EN 62311:2008
- 2016 No.1091 (EMC): EN 60730-1:2011 / EN 60730-2-7:2010/AC:2011 / EN 60730-2-
9:2010
- 2012 n°3032 (ROHS): EN IEC 63000:2018
Neomis Ltd: 16 Great Queen Street, Covent Garden, London, WC2B 5AH UNITED
KINGDOM - contactuk@neomis.com
EU declaraon of conformity: We, Imhotep Creaon, hereby declare
under our sole responsibility that the products described in these
instrucons comply with the provisions of Direcves and harmonized
standards listed below:
- Arcle 3.1a (Safety): EN60730-1:2011/ EN60730-2-7:2010/EN60730-2-9: 2010/
EN62311:2008
- Arcle 3.1b (EMC): EN60730-1:2011/ EN60730-2-7: 2010/ EN60730-2-9: 2010
Imhotep Creaon: ZI Montplaisir - 258 Rue du champ de courses - 38780 Pont-Evêque -
France - contact@imhotepcreaon.com
Neomis Ltd and Imhotep Creaon belong to Axenco Group.
- RoHS 2011/65/UE, amended by Direcves 2015/863/UE & 2017/2102/UE : EN IEC
63000:2018

Overview......................................................................................................... 1
Controls and display ........................................................................................ 1
Sengs ........................................................................................................... 1
Inialpowerup ................................................................................................................1
Programming................................................................................................... 2
SettheCH/Z1programming .............................................................................................2
Operang ........................................................................................................ 2
Modeseleconanddescripon ........................................................................................2
Boost .................................................................................................................................2
Advance.............................................................................................................................2
Holiday ..............................................................................................................................3
Review...............................................................................................................................3
Factorysengs .................................................................................................................3
Setdateandclock .............................................................................................................3
Troubleshoong .............................................................................................. 4
Technical specicaons ................................................................................... 4
Note ............................................................................................................... 4
What is a mer ? ............................................................................................ 4
TMR7 NEO ENG CP V05 06 04 2021
7 DAY SINGLE CHANNEL DIGITAL TIMER
TABLE OF CONTENTS
1
OPERATING
INSTRUCTIONS
• Timer
• LCD Display
CONTROLS AND DISPLAY
Programming sliders sequences:
Time CH/Z1 programming Run
INITIAL POWER UP
SETTINGS
1- Switch on the mer power supply.
All symbols will be displayed on the
LCD screen as shown for two seconds.
2- Aer 2 seconds, the LCD will show:
- The default me and day
- Run icon solid
- CH systems is OFF
OVERVIEW
Thank you for purchasing our TMR7, 7 day single
channel digital mer.
It is by listening to your requirements we have
created and designed our products to be easy to
operate and install.
It is this ease of operaon that is intended to make
your life easier and help you save energy and
money.
constant
all day
auto
off
Mode slider
CH/Z1
Boost CH/Z1
Advance CH/Z1
Reset buon
LCD display
Minus/Plus
Day/Holiday Yes/No
Review
Programming slider
Pairing icon
(RF version)
Holiday icon
Run icon
Review icon
CH/Z1 status
Programming
mode
Hour
Days
Hour seng
Not available on
this version
Low baery icon
Time seng
(Day, Month, Year)
TMR7
Note: A low baery level indicator will appear in the display when the baery must
be changed.
Remember to take used baeries to a baery collecon point so they can be recycled.
Timer baery access

ADVANCE
2
SET THE CH/Z1 PROGRAMMING
On/O periods Default schedule
Two On/O periods sengs
Period 1 Start at 06:30 am End at 08:30 am
Period 2 Start at 05:00 pm End at 10:00 pm
Three On/O periods sengs
Period 1 Start at 06:30 am End at 08:30 am
Period 2 Start at 12:00 pm End at 02:00 pm
Period 3 Start at 05:00 pm End at 10:00 pm
1- Move the Programming slider to posion .
All days of week are solid. Underscore and Yes/
No are ashing.
4- Press or to increment/decre-
ment the rst On/O period end
me.
Then press Yes to conrm.
5- Repeat for the second On/O period
and for the third On/O period.
(Please refer to the advanced installer
sengs on Installaon instrucon to
enable the third On/O period).
2- Press if you want to set an other
day of the week. Underscore moves
under the other days. Then press
to program the underscored day.
3- Press or to increment/decre-
ment the rst On/O period start
me.
Then press to conrm.
6- The current program can be copy to
the next days. Press Yes to copy or No
to program manually the next day.
7- When nished, move the program
slider to posion to conrm.
PROGRAMMING
Note : The unit is already set with correct date and me. Should mer need reseng
for any reasons, please see instrucons on page 3.
OPERATING
MODE SELECTION AND DESCRIPTION
Mode slider sequences for CH/Z1:
Constant all day auto o
Constant: Permanent ON mode. The
system is permanently turned ON.
All day: The system turn ON from the rst
On period start me unl the last O
period end me of the current day.
Auto: Automac mode. The unit is control-
ling to the programming that have been
selected (refer to "Programming" secon
page 2).
O: Permanent O mode. The system stays
O permanently. The boost mode can be
sll used.
Note:
- The Programming slider must be in the posion.
- There will be a slight delay between pressing and acvaon of the relay.
BOOST is cancelled by pressing again on Boost or movement of sliders.
When BOOST is running the end of Boost period is shown for each system.
BOOST
BOOST will work from any running mode.
BOOST is entered by pressing buon.
Press 1 me to set 1 hour, 2 mes to set 2 hours and 3 mes to set 3 hours.
BOOST: Boost mode is a temporary mode
which allows you to switch ON for 1, 2 or 3
hours. At the end of set period the device
will revert to its prior seng.
constant
all day
auto
off
constant
all day
auto
off
Advance: advance mode is a temporary
mode which allows you to switch ON the
system in advance, unl the next On/O
period end me.
Press buon to acvate this mode.
Press again buon to disable it before
the end.
constant
all day
auto
off

3
Sengs Factory sengs
Two On/O periods sengs
Period 1 Start at 06:30 am End at 08:30 am
Period 2 Start at 05:00 pm End at 10:00 pm
Three On/O periods sengs
Period 1 Start at 06:30 am End at 08:30 am
Period 2 Start at 12:00 pm End at 02:00 pm
Period 3 Start at 05:00 pm End at 10:00 pm
4- The preset day appears.
Press to increment the day.
Press to decrement the day.
3- The preset month appears.
Press to increment the month.
Press to decrement the month.
Press to conrm and set
the current day.
Press to conrm and set
the clock.
5- The preset me appears.
Press to increment the me.
Press to decrement the me.
Move the program slider to any other
posion to conrm/nish this seng.
01= January ; 02 = February ; 03 = March ; 04 = April ; 05 = May ;
06 = June ; 07 = July ; 08 = August ; 09 = September ; 10 = October ;
11 = November ; 12 = December
SET DATE AND CLOCK
1- Move the Programming slider to
posion .
Preset year is solid.
2- To select the current year, press , to
increment the year.
Press , to decrement the year.
Press to conrm and set
the current month.
To set the holiday funcon:
REVIEW
HOLIDAY
Holiday: Holiday mode allows to switch o the
heang (or Z1) for a specied number of days,
adjustable between 1 and 99 days.
constant
all day
auto
off
3- Then press to conrm. the
heang (or Z1) switch O and the
number of remaining days will count
down on display.
4- To cancel the holiday funcon, press
buon.
Press buon to start the programming
review.
Press again to go back on normal operang
mode.
Review: Review mode allows to review all
programming in one me. The review starts
from the beginning of the week and each
steps appears each 2 seconds.
1- Press Day buon for 5 seconds.
2- OFF appears on the display. Press
or to increment or decrement the
number of days.
5 sec.
FACTORY SETTINGS
All LCD display will be turned ON for 2 seconds and the factory sengs will be res-
tored.
Note: To restore factory sengs, press and hold down this part for more than 3
seconds using the p of a pen.
constant
all day
auto
off
3 sec.

Registered trademarks - All rights reserved
4
www.neomitis.com
NEOMITIS® LIMITED - 16 Great Queen Street, Covent Garden, London, WC2B 5AH UNITED KINGDOM
Registered in England and Wales No: 9543404
Tel: +44 (0) 2071 250 236 - Fax: +44 (0) 2071 250 267 - E-mail: contactuk@neomis.com
Display disappears on mer:
- Check fused spur supply.
Heang does not come on:
- If the CH Indicator light is on then it is unlikely to be a fault with the mer.
- If CH indicator light is NOT ON then check programme then try BOOST as this should
operate in any posion.
- Check that your room thermostat is calling for heat.
- Check that the boiler is on.
- Check that your pump is working.
- Check that your motorised valve if ed has opened.
If the problem persists contact your installer
Note: If Service due soon or service due appears in display please contact your lan-
dlord.
...an Explanaon for Householders. Pro-
grammers allow you to set ‘On’ and ‘O’
me periods. Some models switch the
central heang and domesc hot water
on and o at the same me, while others
allow the domesc hot water and heang
to come on and go o at dierent mes.
Set the ‘On’ and ‘O’ me periods to suit
your own lifestyle. On some mers you
must also set whether you want the hea-
ng and hot water to run connuously, run
under the chosen ‘On’ and ‘O’ heang periods, or be permanently o. The me on
the mer must be correct. Some types have to be adjusted in spring and autumn at the
changes between Greenwich Mean Time and Brish Summer Time. You may be able to
temporarily adjust the heang programme, for example, ‘Advance’, or ‘Boost’. These
are explained in the manufacturer’s instrucons. The heang will not work if the room
thermostat has switched the heang o. And, if you have a hot-water cylinder, the water
heang will not work if the cylinder thermostat detects that the hot water has reached
the correct temperature.
Please refer to the installing instrucons for any informaons about, standards and pro-
duct environment.
TROUBLESHOOTING
TECHNICAL SPECIFICATIONS
In some instances the unit may have been set with the service interval funcon enabled.
By Law in rented accommodaon, your gas boiler should be inspected/serviced annual-
ly to ensure it is working correctly.
This opon is designed to remind the end user to contact the relevant person to have
the annual service carried out on the boiler.
This funcon will be enabled and programmed by your Installer, maintenance Engineer,
or Landlord.
If it has been set to do so, the unit will display a message on the screen to remind you
that a boiler service is due.
The Service Due Soon countdown will be indicated up to 50 days before the Service is
due to allow me to arrange for an engineer to aend, normal funcons will connue
during this stage.
At the end of this service due soon period, the unit will go to Service Due OFF at which
point only the 1hour boost will operate on TMR7 and PRG7, if the unit is a thermostat
RT1/RT7, it will operate at 20°C during this hour.
If PRG7 RF, Thermostat has no funcon.
NOTE
WHAT IS A TIMER ?
Table of contents
Other Neomitis Thermostat manuals

Neomitis
Neomitis TMR7RFa User manual

Neomitis
Neomitis RTEORFA User manual

Neomitis
Neomitis RTE7D User manual

Neomitis
Neomitis RTE7A User manual

Neomitis
Neomitis RTANEOA User manual

Neomitis
Neomitis RTE7C User manual

Neomitis
Neomitis RT7 RF User manual

Neomitis
Neomitis RTMA User manual

Neomitis
Neomitis RT1 RF User manual

Neomitis
Neomitis RTE1RFD User manual

Neomitis
Neomitis RTE7SD User manual

Neomitis
Neomitis RTE0A User manual

Neomitis
Neomitis RT7 User manual

Neomitis
Neomitis RT0 RF User manual

Neomitis
Neomitis RTE7RFD User manual

Neomitis
Neomitis RTE7D User manual

Neomitis
Neomitis RTE1D User manual

Neomitis
Neomitis RTE0B User manual

Neomitis
Neomitis RTE0RFA User manual