NetApp H610S Manual

215-14243_B0
NetApp HCI compute and storage nodes
Installation and Setup Instructions
Prepare for installation |Stage 1
Access online
You provide
In the box
Configure
the node
4
Perform
post-deployment
tasks
5
Prepare
for installation
Install
hardware
Cable
the node
1 2 3
Power cables
(Two per chassis)
Rack space (order dependent)
H410C and H410S: 2U per chassis
H610C: 2U per chassis
H610S: 1U per chassis
H615C: 1U per chassis
Monitor with a
VGA connection
and keyboard with
a standard USB
connection
SFP28/SFP+
direct-attach cables
or transceivers
Any operating
system (OS) client
with a browser
H610C compute node (order dependent)
H610S storage node (order dependent)
H615C compute node (order dependent)
• End User License Agreement
• Hardware Universe (HWU)
• NetApp HCI Documentation Center
• NetApp HCI Resources page
• NetApp SolidFire Resources page
• SolidFire and Element 11.3 Documentation Center
Slide rail kit
NetApp HCI chassis (only for H410S and H410C)
HCI
UID
UID
UID
UID
NODE D
NODE D
NODE C
NODE C
NODE A
NODE A
NODE B
NODE B
A0 A1 A2 A3 A4 A5 B0 B1 B2 B3 B4 B5 C0 C1 C2 C3 C4 C5 D0 D1 D2 D3 D4 D5
USB stick (optional)
H410C and H410S: Optional,
for out-of-band management
H610C: Optional, recommended
H615C and H610S: Required for out-of-band
management and cluster management
CAT5e or higher cable
with RJ45 connector
H410C compute node
(order dependent)
H410S storage node
(order dependent)

Steps 3 and 4 apply only if you are installing H410C and H410S nodes in a NetApp H-series chassis.
1Install the rails.
2
3
4
Install the chassis.
See Rail Kit Installation instructions.
Note:
• Ensure that you have installed the rack according to the safety instructions from the manufacturer.
• Ensure that the rack is stabilized. The heaviest equipment should be at the bottom of the rack.
• Follow proper grounding practices to avoid risk of electric shock.
• Follow proper airflow and cooling requirements to prevent hardware from overheating.
• Installing the chassis requires two people.
Install hardware |Stage 2
The minimum initial NetApp HCI configuration requires two chassis.
Steps 1 and 2 apply only if you are setting up a new system.
Install nodes in the chassis.
Install drives for storage nodes.
LNK
ACT
POR T 1 POR T 2
LNK
ACT
POR T 1 POR T 2
LNK
ACT
POR T 1 POR T 2
LNK
ACT
POR T 1 POR T 2
CHASSIS BACK VIEW
Node A
Node B
Node C
Node D
Node B Node C Node DNode A
SSD -E
S
SD
-E
S
SD
-E
S
SD
-E
S
SD
-E
S
SD
-E
S
SD
-E
S
SD
-E
S
SD
-E
S
SD
-E
S
SD
-E
S
SD
-E
S
SD
-E
S
SD
-E
S
SD
-E
S
SD
-E
S
SD
-E
S
SD
-E
S
SD
-E
S
SD
-E
S
SD
-E
S
SD
-E
S
SD
-E
S
SD
-E
1
.9 T
B
1
.9 T
B
1
.9 T
B
1
.9 T
B
1
.9 T
B
1
.9 T
B
1
.9 T
B
1
.9 T
B
1
.9 T
B
1
.9 T
B
1
.9 T
B
1
.9 T
B
1
.9 T
B
1
.9 T
B
1
.9T
B
1
.9 T
B
1
.9 T
B
1
.9 T
B
1
.9 T
B
1
.9 T
B
1
.9 T
B
1
.9 T
B
1
.9 T
B
1. 9 T B
CHASSIS FRONT VIEW
LIFTING HAZARD
CAUTION
77.1 lb (35 kg)
H610C
H410C, H615C,
and H410S
LIFTING HAZARD
CAUTION
40.5 lb (18.4 kg)
H610S
LIFTING HAZARD
CAUTION
Approximately
70 lb (31.75 kg)
The installation graphic
is only for illustrative
purposes. Your actual
node might dier based
on what you ordered.

If the airflow vents at the rear of the chassis are blocked by cables or labels, it can lead to premature
component failures due to overheating.
1Cable the compute node.
If you are adding nodes to an existing NetApp HCI installation, ensure that the cabling and network
configuration of the nodes that you add are identical to the existing installation.
Cable the node |Stage 3
H410C compute nodes (choose option A or B)
Connect two SFP28/SFP+ cables or transceivers
for shared management, virtual machines, and
storage connectivity.
(Optional, recommended)
Connect a CAT5e cable in the IPMI port for
out-of-band management connectivity.
10/25GbE cables
Two-cable configuration
OPTION
A
Port D
Port E
IPMI
Connect two CAT5e or higher cables in ports
A and B for management connectivity.
Connect two SFP28/SFP+ cables or transceivers
in ports C and F for virtual machine connectivity.
Connect two SFP28/SFP+ cables or transceivers
in ports D and E for storage connectivity.
(Optional, recommended)
Connect a CAT5e cable in the IPMI port for
out-of-band management connectivity.
10/25GbE cables
1/10GbE cables
Six-cable configuration
OPTION
B
Port D
Port E
Port F IPMI
Port CPort A
Port B

FRONT
VIEW
Cable the node |Stage 3 cont.
Note:
H610C nodes are deployed only in the two-cable configuration. Ensure that all the VLANs are present on ports C and D.
REAR
VIEW
PortC
PortD
IPMI
FRONT
VIEW
Connect the node to a 10/25GbE network using
two SFP28/SFP+ cables in ports C and D.
(Optional, recommended)
Connect the node to a 1GbE network using an
RJ45 connector in the IPMI port.
Connect both power cables to the node.
Plug the power cables to a 200‐240V
power outlet.
Press the power button at the front of the chassis.
Note: It takes approximately five minutes and 30 seconds
for the node to boot.
10/25GbE cables
H610C compute node
Power cables
1/10GbE cables
Note:
H615C nodes are deployed only in the two-cable configuration. Ensure that all the VLANs are present on ports A and B.
Connect the node to a 10/25GbE network using
two SFP28/SFP+ cables in ports A and B.
(Optional, recommended)
Connect the node to a 1GbE network using an
RJ45 connector in the IPMI port.
Connect both power cables to the node.
Plug the power cables to a 110-140V
power outlet.
Press the power button at the front of the chassis.
10/25GbE cables
H615C compute node
Power cables
1/10GbE cables
Port APort B
REAR
VIEW
IPMI

Cable the node |Stage 3 cont.
Connect the node to a 1GbE network using
two RJ45 connectors.
Connect the node to a 10/25GbE network using
two SFP28 or SFP+ cables.
Connect the node to a 1GbE network using
an RJ45 connector in the IPMI port.
Connect both power cables to the node.
Plug the power cables to a suitable power outlet. Press the power button at the front of the chassis.
Note: It takes approximately five minutes and 30 seconds for the node to boot.
10/25GbE cables
1GbE cables
1GbE cable
Power cables
FRONT
VIEW
REAR
VIEW
10/25GbE SFP+
or SFP28 cables
for iSCSI
1GbE RJ45 cable
for out-of-band
management
1GbE RJ45 cables
for management
H610S storage node
3Connect the power cords to the two power supply units
per chassis and plug them into 240V PDU or power outlet.
This step does not apply if you are adding a new node to an existing chassis.
Steps 3 and 4 apply only if you are installing H410C and H410S nodes in a chassis.
Cable the storage node.
If the airflow vents at the rear of the chassis are blocked by cables or labels, it can lead to premature
component failures due to overheating.
Connect two CAT5e or higher cables in ports
A and B for management connectivity.
Connect two SFP28/SFP+ cables or transceivers
in ports C and D for storage connectivity.
(Optional, recommended)
Connect a CAT5e cable in the IPMI port for out-of-band management connectivity.
10/25GbE cables
1/10GbE cables
Port D IPMI
Port CPort A
Port B
H410S storage node
2

Cable the node |Stage 3 cont.
4Power on the
NetApp HCI nodes.
FRONT VIEW
HCI
UID
UID
UID
UID
NODE D
NODE D
NODE C
NODE C
NODE A
NODE A
NODE B
NODE B
A0 A1 A2 A3 A4 A5 B0 B1 B2 B3 B4 B5 C0 C1 C2 C3 C4 C5 D0 D1 D2 D3 D4 D5
UID
UID
NODE A
NODE A
NODE B
NODE B
A0 A1 A2 A3 A4 A5 B0 B1 B2 B3 B4 B5 C0 C1 C2 C3 C4
It takes approximately six minutes for the node to boot.
Configure NetApp HCI |Stage 4(Choose option A or B below)
1. Configure an IPv4 address on the management network (Bond1G) on one storage node.
Note: If you are using DHCP on the management network, you can connect to the DHCP-acquired IPv4 address of the
storage system. For more information about DHCP-acquired IPv4 addresses, see the
NetApp HCI Deployment Guide
.
a. Plug in a KVM to the back of one storage node.
b. Configure the IP address, subnet mask, and
gateway address for Bond1G in the user interface.
You can also configure a VLAN ID for the
Bond1G network.
2. Using a supported web browser (Mozilla Firefox,
Google Chrome, or Microsoft Edge), navigate to the
NetApp Deployment Engine by connecting to the IPv4
address that you configured in Step 1.
3. Use the NetApp Deployment Engine user interface (UI) to configure NetApp HCI.
Note: If you are expanding your installation using H615C compute nodes, you must ensure that the cluster runs
on NetApp HCI 1.7 or later.
1. Using a supported web browser, browse to the IP address of the management node.
2. Log in to the NetApp Hybrid Cloud Control by providing the NetApp HCI storage cluster
administrator credentials.
3. Follow the steps in the wizard to add storage and/or compute nodes to your NetApp HCI
installation. The newly installed NetApp HCI nodes on the same network will be discovered
automatically. For more information, see the NetApp HCI Deployment Guide.
All the other NetApp HCI nodes that you installed will be discovered automatically.
For more information, see the
NetApp HCI Deployment Guide.
.
Setting up a new NetApp HCI installation
OPTION
A
Expanding an existing NetApp HCI installation
OPTION
B
The cabling and network configuration of the nodes that you add must be identical to the existing
NetApp HCI installation.

Perform post-deployment tasks |Stage 5
HCI
UID
UID
NODE D
NODE D
NODE C
NODE C
D1 D2 D3 D4 D5
H610C compute node
Install the GPU drivers in ESXi for each H610C node that you installed, and validate their functionality.
See the NetApp Deployment Guide.
H610S storage node
Configure out-of-band management using the Baseboard Management Controller (BMC).
1. Use a web browser and navigate to the default BMC IP address: 192.168.0.120
2. Log in using the following default credentials: User name: root Password: calvin
3. From the node management screen, navigate to Settings > Network Settings, and configure
the network parameters for the out-of-band management port.
See How to access BMC and change IP address on H610S.
H615C compute node
• If your H615C node has GPUs in it, install the GPU driver.
See the NetApp Deployment Guide.
• Configure out-of-band management using the Baseboard Management Controller (BMC).
1. Use a web browser and navigate to the default BMC IP address: 192.168.0.120
2. Log in using the following default credentials: User name: root Password: calvin
3. From the node management screen, navigate to Settings > Network Settings, and configure
the network parameters for the out-of-band management port.
This manual suits for next models
5
Table of contents
Other NetApp Server manuals
Popular Server manuals by other brands

Lenovo
Lenovo ThinkServer RD530 Guide d'utilisation

ASROCK
ASROCK Rack 2U4FH-8L user manual

Supermicro
Supermicro SuperWorkstation SYS-740A-T user manual

ZyXEL Communications
ZyXEL Communications VANTAGE RADIUS 50 brochure

HP
HP HPE ProLiant ML30 Gen9 Maintenance and service guide

Fujitsu
Fujitsu PRIMERGY TX2540 M1 Upgrade and maintenance manual