Netech MultiPro 2000 User manual

MultiPro 2000 User Manual
2
Dear User,
We appreciate your purchase of Netech’s New and
enhanced Model of MultiPro 2000, Electrical Safety
Analyzer. For over a quarter of a century Netech is
dedicated to provide our customers with high quality,
value added products.
Properly used, the MultiPro 2000 delivers more
performance and accuracy than any other Electrical
Safety Analyzer in its price range. This manual has been
designed as a tool to help you get the most from your
MultiPro 2000. We suggest that you carefully read this
manual so that you will be able to properly use and
maintain this product. We welcome any comments you
may have that could help us improve the MultiPro 2000
and this manual.
Netech is recognized as an innovator and manufacturer
of advanced affordable instruments. When you buy our
products we guarantee absolute satisfaction. Your
business is important to us and we are dedicated to
provide you with the best service possible.
We are pleased you selected the MultiPro 2000 to meet
your needs. We hope you will consider us again when
you have a requirement for accurate, reliable, versatile,
and yet affordable instruments.
Please visit our website www.Netechcorp.us for the latest
product updates and user manuals.
Sincerely,
President

MultiPro 2000 User Manual
3
Copyright
Copyright © 2015 by Netech Corporation. All rights
reserved. No part of this publication may be
reproduced or transmitted in any form other than for
the purchaser’s personal use without written
permission from Netech Corporation.
Quality
Assurance
Netech Corporation is ISO 9001-2008 Certified. This
instrument was thoroughly tested and inspected
according to Netech’s ISO QS standards and test
procedures, and was found to meet those
specifications when it was shipped from the factory.
Calibration measurements are traceable to National
Institute of Standards and Technology. A calibration
certificate is included with the unit.
Technical Support
For technical support questions either email
techsupport@netechcorp.us or fill in the information
for fast response.
Trade Marks
Netech and MultiPro 2000 are the trade mark of
Netech Corporation. Any trade mark reference used in
the manual are only for editorial purpose and the
benefit of the respective trademark owner, with no
intention of improperly using that trade mark.
Manufacturing Location
Netech Corporation, Farmingdale, NY 11735

MultiPro 2000 User Manual
4
Symbol Description
Risk of Danger. Important Safety Information
Risk of Electric Shock
Conforms to European Union Directive
WARNING
Unauthorized user modifications or improper use
beyond the scope and purpose of the unit as
published in this manual may result in shock hazard
and injury. Netech will not be liable for any injury
sustained due to the modifications or improper use.
Safety Considerations
•Read all safety information prior to use.
•Do not apply more than the rated input voltage.
•Do not connect a device that exceeds the rated
current.
•Do not use the unit around explosive
environments.
•Do not use the unit if it is damaged.
•Use proper safety precautions
Intended Use
The MultiPro 2000 is intended to be used by a trained
Biomedical Technician who performs preventive
maintenance and repair of medical equipments.
It is intended to be used in an environment outside of
the patient care area and not to be used to test units
while connected to patients.

MultiPro 2000 User Manual
5
Table of Contents
General Description .................................................................... 6
Introduction............................................................................... 6
Preparation for Use..................................................................... 8
Instrument Familiarization................................................. 8
Menu Functions and Operation............................................10
Main Menu................................................................................10
Getting Started ............................................................................13
Menu Descriptions................................................................13
Measurements.............................................................................17
Earth Leakage: ........................................................................17
Case Leakage: Using External Leads.............................19
External Leakage: Point to Point Measurement .......20
Leads Leakage:........................................................................21
Power Cord Ground Resistance.......................................24
Simulator Function: ..................................................................25
Save and Print Test Results ...................................................27
Saving test results in the internal memory.................27
Software setup........................................................................28
ProComPrint Version 1.0 Features............................29
Uploading Test Results........................................................32
Specifications...............................................................................33
Maintenance:................................................................................35
Product Return Instruction ...................................................35
Netech Products and Services ..............................................37
Replacement Parts and Accessories ..................................38
WARRANTY..................................................................................39

MultiPro 2000 User Manual
6
General Description
Introduction
The Multi-Pro 2000 (PN: 560) is a full featured, compact
portable analyzer designed for the testing of the
electrical safety of medical devices. The analyzer tests to
US standards (ANSI/AAMI ES1, NFPA 99) or international
standards IEC60601-1 by user selectable patient loads.
It is compact, lightweight and user friendly unlike any
other safety analyzer in the market. The Analyzer is a
measurement device as well as a waveform simulator.
The Analyzer is capable of saving over 5000 test records
and can be uploaded to a PC for printing and record
keeping using the software shipped with the unit.
Optional stand alone “Equipment Maintenance
Software” is also available for the PC s.
The Analyzer is designed to be used for the quick and
easy measurement of the following functions.
•Line Voltage.
•Equipment current
•Polarity Check of the inlet AC power.
•Chassis (Enclosure) Leakage.
•Ground wire (Earth) leakage.
•Point to point leakage.
•Ground Wire Resistance.
•Patient leads leakage.
•Patient Isolation leakage test.

MultiPro 2000 User Manual
7
•Save and print test results.
The following waveform simulation functions are
available.
•ECG – Normal Sinus Rhythm (NSR).
•Performance – SIN, SQUARE, TRIANGLE, PULSE.
•User selectable Amplitude and rate.
The waveform output is through the 10 color coded ECG
snap posts marked RL, LL, RA, LA, V1, V2, V3, V4, V5, and
V6. All 12 ECG configurations are out put through the 10
outputs.

MultiPro 2000 User Manual
8
Preparation for Use
The Analyzer is shipped with power cord, 2 Test leads,
Kelvin Cable, Serial to USB interface cable and user
manual and Print Software CD in a hard carrying case.
Also included is our calibration certificate along with
Calibration Data sheet. Please inspect the unit for any
visible shipping damages.
Before getting started it is important to get familiar with
the control and the operation of the unit.
Instrument Familiarization
Display:
The Multi-Pro 2000 incorporates a vacuum fluorescent
display. The display ensures high readability even under
the lowest ambient light conditions.
Keypad:
The keypad utilizes soft touch tactile keypads, providing a
fluid resistant barrier to the internal circuitry. When a key
is pressed a beeping sound will be heard to indicate that
the key is activated.
The following are the description of the key functions.
•F1, F2, F3, F4, F5, and F6:- These are interactive
keys associated with the menu selections.
•“ESC”:- Pressing “ESC” key will get back to the
previous menu.

MultiPro 2000 User Manual
9
•“MENU”:- Pressing “MENU” key will bring back to
the “MAIN MENU”
•“READ”: “READ” key is associated with the
measurement functions as well as to save the
displayed test data in to the storage memory.
•“CASE LEAKAGE”:- Case Leakage Measurement
Function Key. Pressing the key will display the
“CASE LEAKAGE” Menu with the prompt “Select
Polarity” to enable further measurement options.
•“LEADS LEAKAGE”:- Leads Leakage Function Key.
Pressing the key enables the “LEADS LEAKAGE”
Menu selections.
•“RESISTANCE MEASUREMENT”:- Resistance
Measurement key enables the power cord
ground wire resistance measurement menu with
the prompt to connect the Kelvin Cable to the
chassis or the earth ground point of the unit
under test (DUT).
•“SIMULATOR”: Simulator Key enables the
Simulator menu selections. Further waveform
selections are available with F1, F2, F3, F4 and F5
keys.
Power Switch:
The main power switch is located on the right side panel
of the Multi-Pro. This switch turns the power on/off to
the Multi-Pro 2000.
Test Outlet:

MultiPro 2000 User Manual
10
The test receptacle used in the Multi-Pro is a Hospital
Grade 20 Amp (NEMA-5-20R). It will accept all standard
line cords as well as horizontally oriented neutral prongs
on 20 Amp line cords.
Various International power outlet configurations are
available. Check with factory for the specific Country.
Power to the test receptacle is in the off mode. Manual
selection of normal or reverse polarity must be selected
using the keypad to energize the test receptacle during
leakage measurement functions.
Menu Functions and Operation
The operation of the MultiPro 2000 is Menu driven. It is
simple and easy to use following the interactive Menus
with soft keys (F1,F2, F3, F4, F5, F6) and dedicated key
functions such as “Simulator” “Case Leakage”, Leads
Leakage”, Resistance Measurement”.
Main Menu
Following are the abbreviation and description of each
“Main Menu” functions.
•“INT”- Internal measurements.
Additional menu selections in this category are:-
“VOL”- Input Voltage,
“CUR”- Device current
“POL”- Polarity check of the AC input.
Refer to “Measurement Section for details.

MultiPro 2000 User Manual
11
•“EXT” - External Measurement.
•“ID”- For entering a unique (4 Digit) reference ID
of the instrument under test.
This option is useful for measuring the leakage
current of Hard Wired Units, Non AC Powered
(Battery Operated) or any devices.
•“TIME” - Setting real time clock.
•“PRN” –Printing the test results and Header.
•“CFG”– Configuration. (This function is only
available for software upgrade and other factory
settings)
In addition to the “MAIN MENU” function, dedicated keys
are provided for each of the main functions. They are
described as follows:-
•“CASE Leakage” – Case Leakage current
Measurement.
•“LEADS Leakage” Leads Leakage current
measurement.
•“RESISTANCE Measurement”- Ground conductor
resistance Measurement.
•“SIMULATOR” – Waveform Simulation selection.
•“ESC” – ESC key takes back to the previous
Menu.
•“MENU” – Takes back to the Main Menu.
The power to the outlet of the unit under test is
controlled by the “OUTLET POWER” key functions.
•“NORMAL POLARITY” – Set polarity to Normal.

MultiPro 2000 User Manual
12
•“OFF” – Enables the Power the outlet to turn off.
•“REVERSE POLARITY” – Set the outlet to reverse.

MultiPro 2000 User Manual
13
Getting Started
Connect the Analyzer to a grounded three prong outlet.
The Analyzer is intended for use with single phase ground
power. It is not intended for dual phase power
configurations.
Turn the Analyzer on using the rocker switch on the side
panel. The Analyzer will perform a series of self tests and
momentarily display the model name and the software
version followed by the “MAIN MENU” as shown below.
Menu Descriptions
Before connecting the DUT (Device Under Test), it is
important to get familiar with the operation of the unit
and observe the safety precautions.
The following is the screen shot of the “Main Menu” on
power up as shown (Screen Shot 1).
“INT” :- Internal Measurement
Line Voltage Measurement
From the “MAIN MENU” select “INT” by pressing F1
Screen Shot 1

MultiPro 2000 User Manual
14
Key. The display will change to the “INTERNAL
MEASUREMENT “Menu Press F1 Key (“VOL”) and
the line voltage will be displayed.
Press “ESC” to go back to the previous Menu
(“INTERNAL MEASUREMENT “Menu).
(“CUR”):- Device Current Measurement.
This function measure the current consumed by the
DUT. To measure the current, press F2 (“CUR”) from
the “INTERNAL MEASUREMENT“ Menu. Press
“READ” to read the device current.
If the out let is off, normal polarity will be activated
and the unit (DUT) will turn on.
Press “ESC” to go back to the previous Menu
(“INTERNAL MEASUREMENT “Menu).
(“POL”) Polarity Check of the Inlet Power.
From the “INTERNAL MEASUREMENT “Menu select
“POL” by pressing F3. The polarity of the incoming
AC power will be checked by measuring the voltage
between HOT and Neutral, HOT and Earth ground as
well as and Neutral and Earth ground. While
checking polarity the display will indicate
“Checking………” for a brief period and the polarity
will then be displayed as “Normal Polarity” or
“Reverse Polarity” depending on the result.
If an “Error” message appears either the outlet the

MultiPro 2000 User Manual
15
Multi-Pro is attached to or the power cord for the
Multi-Pro may be defective. Press “ESC” to return to
the previous menu or press “MENU” to return to the
main menu.
EXR”:- External (Leakage) Measurement
It is also referred to as point to point Leakage.
This function measures Leakage current between
two points on the DUT (Device under Test)
“ID”:- Device Identification Input Function.
MultiPro 2000 is capable of storing over 5000
test results in the Non- volatile memory and can
be uploaded to a PC, to save or print the records.
The “Save” option is available in all the
measurement Menu (refer to Measurement
Section).
This function is indended for the user for entering
a unique 4 digit number for the Device under
Test (DUT). This will enable the test data to be
stored under this unique ID number. Here is how
to enter the Device ID.
From the “MAIN MENU” select “ID” using key
F3. The display will change to “Equipment ID:
0000 as shown Screen Shot 2 below. If a
Device ID is already entered it will show in
the menu.

MultiPro 2000 User Manual
16
To change the ID, press F6 (yes). Press F1, F2,
F3 F4 keys to enter a unique ID for the unit
under test.
•If an ID is already entered for the unit under
test press F4 (N0).
Note:-
When testing multiple units it is important to change the
ID as the test records are saved under this ID number.
“TIME”:- Time re setting Function.
Pressing F4 from the “MAIN MENU” activates the
“Change Time” menu. To change the time use the
appropriate keys associated with the menu.
Screen Shot 2

MultiPro 2000 User Manual
17
Measurements
Earth Leakage:
Earth leakage is compliant to IEC 60601 and ANS/AAMI
ES1 standard. The default compliant standard is set to
AAMI ES1. The Compliant standard can be changed by
pressing F1 to toggle between (AAMI “ES1” or “IEC”
60601). This will be saved to the memory until it is
changed again.
There are four Leakage measurement options.
•Normal Polarity
•Reverse Polarity
•Open Neutral
•OFF. Select the desired polarity.
The Earth leakage measurement is through the internal
ground conductor and the external test lead is not
required. To measure the current flowing in the
protective Earth circuit, press the key marked “Case
Leakage”. The display will indicate “CASE LEAKAGE” and
“Select Polarity” and “ES1” /IEC (AAMI ES1) or “IEC”
60601) selection.
Select the desire polarity and press “READ”. The display
will indicate the leakage as well as the polarity selected
as shown in Screen Shot 3. Press F1 (“SAVE”) to save the
results.

MultiPro 2000 User Manual
18
To save the result press F1 (“SAVE”). This will save the
test data in the memory under Device ID.
To measure leakage for open neutral conditions first
select first select “NORMAL POLARITY” followed by F6 to
open the neutral.
The auto-range feature of the MultiPro will select the
appropriate range automatically. For reading in excess of
100 micro amps, the decimal point will not be displayed.
The user can switch between Reverse and normal
Polarity at any time to verify readings or, to determine if
any service action performed on the device under test
affects the readings.
The following block diagram shows the electrical
connections between The Safety Analyzer and the device
under test.
Screen Shot 3

MultiPro 2000 User Manual
19
Case Leakage: Using External Leads
Case /Enclosure leakage measurement is similar to
Earth Leakage measurement except the leakage
current is measured through the external test Lead.
To measure the case leakage/Enclosure leakage,
attach the external Kelvin cable to the case
(conductive surface) of the (DUT) device under test.
Select the desired polarity and press “READ”.
The display will indicate the leakage as shown in the
Screen Shot 4. Press F1 (“SAVE”) to save the results.
Case leakage measurements can be made for
various line conditions, power on, off, normal or
reverse polarity, closed or open ground, Closed or
open neutral.

MultiPro 2000 User Manual
20
The following block diagram shows the electrical
connections between The Safety Analyzer and the device
under test.
External Leakage: Point to Point Measurement
It is also referred to as point to point Leakage.
This function can be used to measure Leakage
current flowing from any conductive surface of
the DUT and Earth ground.
From the “MAIN MENU” select “XTR” (F3 Key).
“EXTERNAL LEKAGE” Menu will be displayed with
the prompt to connect the Input Cable (Screen Shot
4). The external input Jacks are on the left panel
marked “INPUT”. To measure the leakage between
two points, connect one lead to one point (Earth
Ground) of the DUT and the other lead to another
conductive point on the DUT and press “READ”.
This manual suits for next models
2
Table of contents
Other Netech Measuring Instrument manuals

Netech
Netech EXPMT 2000 User manual

Netech
Netech LKG 601 User manual

Netech
Netech UPM 2000 User manual

Netech
Netech MT-200 User manual

Netech
Netech DigiFlow 2000 User manual

Netech
Netech DigiMano 1000 User manual

Netech
Netech LKG 610 User manual

Netech
Netech DigiMano 2000 User manual

Netech
Netech LKG 610 User manual

Netech
Netech EXPMT 2000 User manual