netsys NB-301A User manual

NB-301A
G.SHDSL bis LAN EXTENDER
USER’S MANUAL

NB-301A G. SHDSL bis LAN EXTENDER USER’S MANUAL Ver. A.2
1
Copyright
Copyright © 2008 by National Enhance Technology Corp. All rights reserved.
Trademarks
NETSYS is a trademark of National Enhance Technology Corp.
Other brand and product names are registered trademarks or trademarks of their respective holders.
Legal Disclaimer
The information given in this document shall in no event be regarded as a guarantee of conditions or characteristics. With respect to
any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device,
National Enhance Technology Corp. hereby disclaims any and all warranties and liabilities of any kind, including without limitation
warranties of non-infringement of intellectual property rights of any third party.
Statement of Conditions
In the interest of improving internal design, operational function, and/or reliability, NETSYS reserves the right to make changes to the
products described in this document without notice. NETSYS does not assume any liability that may occur due to the use or
application of the product(s) or circuit layout(s) described herein.
Maximum signal rate derived form IEEE Standard specifications. Actual data throughput will vary. Network conditions and
environmental factors, including volume of network traffic, building materials and construction, and network overhead lower actual
data throughput rate.

NB-301A G. SHDSL bis LAN EXTENDER USER’S MANUAL Ver. A.2
2
Overview
NB-301A (G.shdsl bis LAN Extender) from Netsys provides a broadband transmission speed up to 5.7Mbps through
G.shdsl bis connection over single pair copper line for point-to-point LAN connectivity between two sites. With its rate
adaptive features, NB-301A provides longer reach on transmission distance. Users may also select a fixed data rate for the
copper line ranging from 144kbps to 5,696kbps.
A pair of NB-301A offers a cost effective solution for bandwidth-hungry applications such as video-conferencing and
distant learning over twisted pair telephone line. NB-301A is indeed an ideal symmetrical broadband solution for
LAN-to-LAN connectivity, Internet access, VOIP application and etc.

NB-301A G. SHDSL bis LAN EXTENDER USER’S MANUAL Ver. A.2
3
Safety Warnings
For your safety, be sure to read and follow all warning notices and instructions before device use.
•DO NOT open the device or unit. Opening or removing covers can expose you to dangerous high voltage points or other risks.
ONLY qualified service personnel can service the device. Please contact your vendor for further information.
•Use ONLY the dedicated power supply for your device. Connect the power cord or power adaptor to the right supply voltage (110V
AC in North America or 230V AC in Europe).
•DO NOT use the device if the power supply is damaged as it might cause electrocution. If the power supply is damaged, remove it
from the power outlet. DO NOT attempt to repair the power supply. Contact your local vendor to order a new power supply.
•Place connecting cables carefully so that no one will step on them or stumble over them. DO NOT allow anything to rest on the
power cord and do NOT locate the product where anyone can work on the power cord.
•DO NOT install nor use your device during a thunderstorm. There may be a remote risk of electric shock from lightning.
•DO NOT expose your device to dampness, dust or corrosive liquids.
•DO NOT use this product near water, for example, in a wet basement or near a swimming pool.
•Connect ONLY suitable accessories to the device. Make sure to connect the cables to the correct ports.
•DO NOT obstruct the device ventilation slots, as insufficient airflow may harm your device.
•DO NOT store things on the device.
•DO NOT use the device outside, and make sure all the connections are indoors. There may be a remote risk of electric shock from
lightning.
•Be careful when unplugging the power, because the transformer may be very hot.
•Keep the device and all its parts and accessories out of children’s reach.
•Clean the device using a soft and dry cloth rather than liquid or atomizers. Power off the equipment before cleansing it.
•This product is recyclable. Dispose of it properly.

NB-301A G. SHDSL bis LAN EXTENDER USER’S MANUAL Ver. A.2
4
Table of Contents
1. Unpacking Information ........................................................................................................................................................ 5
Check List................................................................................................................................................................................. 5
2. Installing the Modem............................................................................................................................................................ 6
Hardware Installation ............................................................................................................................................................... 6
Pre-installation Requirements................................................................................................................................................. 6
Application Notes..................................................................................................................................................................... 7
Installation Procedure.............................................................................................................................................................. 7
3. Hardware Description .......................................................................................................................................................... 9
Front Indicators........................................................................................................................................................................ 9
4. Console Port Control ........................................................................................................................................................... 10
Main Menu................................................................................................................................................................................. 12
Configuration Screen............................................................................................................................................................... 14
Status Screen ........................................................................................................................................................................... 20
5. Data Rate & Distance ........................................................................................................................................................... 24
Appendix A: Product Specification ........................................................................................................................................ 25
Key Features & Benefits .......................................................................................................................................................... 25
Product Specification .............................................................................................................................................................. 26
Appendix B: Compliance and Safety Information ................................................................................................................. 28
Warranty.................................................................................................................................................................................... 31

NB-301A G. SHDSL bis LAN EXTENDER USER’S MANUAL Ver. A.2
5
1. Unpacking Information
Check List
Carefully unpack the package and check its contents against the checklist.
Package Contents
•One NB-301A unit with dimension of 150x135x30 (mm)
•One power adapter
•One DB-9 Console Cable
•One User’s Manual (Compact Disk)
Please inform your dealer immediately for any missing or damaged parts.
If possible, retain the carton including the original packing materials.
Use them to repack the unit in case there is a need to return for repair.

NB-301A G. SHDSL bis LAN EXTENDER USER’S MANUAL Ver. A.2
6
2. Installing the Modem
Hardware Installation
This chapter describes how to install the LAN extender and establishes network connections. You may install the LAN
extender on any level surface (e.g. a table or shelf). However, please take note of the following minimum site
requirements before you begin.
Pre-installation Requirements
Before you start the actual hardware installation, make sure you can provide the right operating environment including
power requirements, sufficient physical space and proximity to other network devices that are to be connected.
Verify the following installation requirements:
•Power requirements: DC 12V/1A or above.
•LAN extender should be located in a cool dry place with at least 10cm/4in of space at the front and back
for ventilation.
•Place the LAN extender out of direct sunlight and away from heat sources or areas with a high amount of
electromagnetic interference.
•Check if network cables and connectors needed for installation are available.

NB-301A G. SHDSL bis LAN EXTENDER USER’S MANUAL Ver. A.2
7
Application Notes
Ethernet to Ethernet Bridge Extension as shown in figure 1.
Figure 1. Ethernet to Ethernet Bridge Extension
Installation Procedure
Step 1. Connect G.SHDSL Line to DSL RJ-45 connector on NB-301A back panel
Pin4&Pin5forG.SHDSLLine
Figure 2. RJ-45 Connector Pin Assignment for G.SHDSL Line Interface
5.696 Mbps at 7,000 ft
Ethernet Ethernet
Interface
Central Office
NB-301A STU-C Remote Side
NB-301A STU-R
G.SHDSL Copper Lines

NB-301A G. SHDSL bis LAN EXTENDER USER’S MANUAL Ver. A.2
8
Step 2. Connect Ethernet to RJ-45 Port with CAT 5 LAN cable
Step 3. Connect the power adapter to the NB-301A 12VDC outlet
Step 4. Turn on the power. Set one NB-301A as STU-C from Console port, and the other NB-301A as STU-R
Step 5. Set the desired Data Rate for G.SHDSL connection from Console port. Note that both NB-301A must set the same
data rate settings.
Step 6. Both units of NB-301A will automatically connect with each other.
Turn on the power and NB-301A will then execute self-test routines. There will be 2 or more handshaking cycles when adaptive
rate is selected. The system will automatically adapt to maximum rate according to the line distances. The maximum rate is
5696 kbps for 1-pair G.SHDSL line.

NB-301A G. SHDSL bis LAN EXTENDER USER’S MANUAL Ver. A.2
9
3. Hardware Description
Front Indicators
The Modem has FIVE LED indicators on the front panel of NB-301A displaying the current status. The following Table
shows the description. (Table 1)
Table 1 LED Indicators Description and Operation
LEDs Color Status Descriptions
On The device is receiving the power and functioning properly.
POWER Green
Off The device is not ready or has malfunctioned.
On NB-301A is self-testing after power on.
TEST Green
Off NB-301A is ready to link.
On G.SHDSL line connects successfully.
LINE
Green Blink G.SHDSL connection is in progress.
Off G.SHDSL connection not ready.
On LAN port is in connection.
LAN
Green Blink LAN port shows data activity.
Off LAN port connection is down.

NB-301A G. SHDSL bis LAN EXTENDER USER’S MANUAL Ver. A.2
10
On LAN Ethernet connection is at 100Mbps.
100M Green
Off LAN Ethernet connection is at 10Mbps.
4. Console Port Control
The NB-301A provides an RS232C console port for user to monitor the OA&M status through a VT100 terminal. This section
covers the operation procedures, settings and for all screen selections.
Connect the RS232 cable to the COM port of the computer as shown in the following diagram. Set the personal computer to
VT100 or VT102 type through HyperTerminal. Press the <ESCAPE> key and the main menu will be shown on the screen of
the terminal. The terminal operations can then start.
If the <ESCAPE> key is pressed and the screen of the terminal does not display, this may be due to the incorrect COM port
setting. Choose the right COM port (COM1 or COM2) on the computer, and press the <ESCAPE> key again to make sure
that the main menu appears on the terminal screen. Note that the COM port should be set as 9600 bps, none parity, 8 data
bit, and 1 stop bit.

NB-301A G. SHDSL bis LAN EXTENDER USER’S MANUAL Ver. A.2
11
Figure 3. Connection for Console Port with RS232 Terminal
Console Port 9600,
N, 8, 1
DB-9 Connector
VT100 / 102 Terminal
RS232 Cable
STU-LAN NB-301A

NB-301A G. SHDSL bis LAN EXTENDER USER’S MANUAL Ver. A.2
12
Main Menu
Main Menu will display the connection status of the STU-LAN NB-301A unit and settings including two sections:
Configuration, and Status. For details please refer to Table 2.
Table 2. Main Menu

NB-301A G. SHDSL bis LAN EXTENDER USER’S MANUAL Ver. A.2
13
The pull-down tree structure of the main menu is shown in Figure 4.
Figure 4. Pull-down Tree Structure of the main menu
DSL Mode
DSL Speed
Default Configuration
Main
Menu
Configuration
Status
System Information
System Status

NB-301A G. SHDSL bis LAN EXTENDER USER’S MANUAL Ver. A.2
14
Configuration Screen
Configuration screen will display the selections of connection for the NB-301A unit and the screen includes three selections:
DSL Mode Settings, DSL Speed Settings, and Default Configuration.
For details please refer to Table 3.
Table 3. Configuration screen

NB-301A G. SHDSL bis LAN EXTENDER USER’S MANUAL Ver. A.2
15
DSLModeSettings:
Table 4. DSL Mode Settings screen
This screen provides DSL mode settings and user can update the settings from this screen. The initial values of DSL Mode
settings are read from EEPROM.
CO/RT:
The item of CO/RT has 2 options: STU-C and STU-R. To establish a successful connection for two NB-301A units, it
is necessary to set one unit to STU-C and the other unit to STU-R.

NB-301A G. SHDSL bis LAN EXTENDER USER’S MANUAL Ver. A.2
16
2P/1P:
NB-301A supports 1-pair G.SHDSL application. To establish a successful connection for two NB-301A units, it is
necessary to set the two units to the same selection.
Minimum Noise Margin:
The item of Minimum Noise Margin has 6 options: NM=OFF, NM= 1dB, NM=2dB, NM=3 dB, NM=4 dB, or NM=5 dB. If
user sets to NM= 1dB, then noise margin ≧1 dB is guaranteed for DSL connection. If user sets to NM=OFF, this function is
disabled.

NB-301A G. SHDSL bis LAN EXTENDER USER’S MANUAL Ver. A.2
17
DSL Speed Settings:
Table 5. DSL Speed Settings screen
This screen provides DSL Speed Settings and user can configure DSL speed to set the transmission rate.
For 1-pair setting in the DSL Mode menu, the options are as following;
64 kbps, 128 kbps, 192 kbps, 256 kbps, 384 kbps, 512 kbps, 768 kbps, 1152 kbps, 1536 kbps, 1544 kbps, 2048 kbps, 2304
kbps, 2560 kbps, 2816 kbps, 3072 kbps, 3328 kbps, 3584 kbps, 3840 kbps, 4096 kbps, 4352 kbps, 4608 kbps, 5696 kbps,
and Adaptive speed.
The user must set both units of NB-301A to the same speed selection in order to establish a successful connection for 64

NB-301A G. SHDSL bis LAN EXTENDER USER’S MANUAL Ver. A.2
18
kbps, 128 kbps, 2560 kbps, 2816 kbps, 3072 kbps, 3328 kbps, 3584 kbps, 3840 kbps, 4096 kbps, 4352 kbps, 4608 kbps,
5696 kbps and Adaptive speed.
For the rate speed options between 192 kbps and 2304 kbps, the STU-R NB-301A regardless its speed option will follow the
speed of STU-C NB-301.
When setting for adaptive rate, 2 or more activation cycles are necessary. The system will automatically adapt to maximum
speed according to the line distances. The maximum speed for adaptive rate is 4608 kbps.

NB-301A G. SHDSL bis LAN EXTENDER USER’S MANUAL Ver. A.2
19
Default Configuration Setting:
Table 6. Default Configuration Setting screen
When Default Configuration is selected, all the settings of NB-301A will go back to default settings. For the screen as shown
in Table 6, it indicates setting is finished and press <ESC> key will be back to previous screen. The default settings of
NB-301A are as following:
STU-C
1 Pair
Adaptive speed
NM=1 dB
Table of contents
Other netsys Extender manuals