NEULOG PRESSURE LOGGER SENSOR GUIDE
NeuLog pressure logger sensor
NUL-210
The NeuLog pressure sensor can be used for any science experiment which requires
an accurate pressure measurement such as in the fields of Physics, Biology,
Physiology, Microbiology, Botany, Weather Science, etc.
The sensor comes pre-calibrated so you can start experimentation right out of the box
using this guide.
Both the pressure and barometer sensors measure pressure however, the pressure
sensor is much easier to connect to labware such as syringes, beakers and test tubes,
whereas the barometer sensor is ideal for testing atmospheric pressure in the open or
in large containers. The sensor's probe and the additional hose are designed to allow
easy connections to various openings.
Among hundreds of possible experiments that can be performed with the NUL-210
sensor are: Boyle’s Law, Gay-Lussac’s Law for ideal gases, weather phenomena,
yeast and microbe fermentation, chemical reactions, and many more.
The pressure sensor is capable of measuring in four different units of measure:
Kilopascal (kPa): The SI unit of pressure
Atmospheres (atm): A pressure unit equal to one earth atmosphere at sea
level (101.325 kPa)
Pounds per square inch (psi): The unit of pressure which measures the
amount of force (in pounds) a gas or liquid exerts across one square inch
Bar: A non-SI unit equal to exactly 100 kPa
Quick start procedure:
PC or Mac Computer
Materials needed:
NUL-210 Pressure Sensor
USB-200 USB Module
USB to mini USB cable (included with the USB-200 module)
Your pressure sensor needs to be connected to a USB-200 module. The USB-200
module then connects to a computer via a USB to mini-USB cable. Please note that
you cannot plug the pressure sensor directly into the computer.
The browser based application can be downloaded for free at www.NeuLog.com as
well as a full application user guide.
Choose "Downloads" on the main menu and then choose "Software and Application".
Procedure:
1. Install the NeuLog application.
2. Connect the USB-200 module to the PC or Mac
3. Connect the pressure sensor to the USB-200 module (they directly plug
together). Please note that no calibration is required for this sensor.
4. Open the NeuLog application by clicking on the shortcut on the screen.
5. Once a pressure sensor module box appears on the left side of the screen, the
probe has been automatically identified and you can begin experimentation.
6. If the pressure sensor is not automatically identified then click the “Search for
sensors” icon to find the sensor.
7. Click the “On-line experiment” icon; this will open a graph below.
8. Click on the “Module setup” button located in the pressure sensor module box to
change the sensor settings if need be.
9. Click on the "Experiment setup" icon to change the experiment settings if need
be (experiment duration for example).
10. The pressure sensor will give a live reading in its module box to the left of the
screen while plugged in.
11. To run an experiment and collect data click the “Run experiment” icon.
12. To end data collection early, click the “Stop experiment” icon.
Tablet, smart phone device
Materials needed:
NUL-210 Pressure Sensor
WIFI-201 WiFi Module
BAT-200 Battery
Your pressure sensor needs to be connected to a WIFI-201 module. The WIFI-201
module will create a closed NeuLog WiFi network which will stream the NeuLog data
to a device of your choosing. Once your device is wirelessly connected to the NeuLog
network you can run experiments and collect data through a browser of your choosing.
NEULOG PRESSURE LOGGER SENSOR GUIDE
Procedure:
1. Connect the pressure sensor directly to the left side of a WIFI-201 module (no
wires required).
2. Connect a BAT-200 module to the right side of the WIFI-201 module.
3. Although not required, we recommend plugging the BAT-200 to an outlet using a
USB to mini USB charger (such as a typical cell phone charger). The WIFI-201
module will run for 60-90 minutes (depending on the sensor) without being
plugged in.
4. The WIFI-201 module can be powered directly using a mini to USB cord and
plugging it into your computer or a wall charger. Please note this function is only
available on WIFI-201 modules with the USB icon on the cover.
5. For further WIFI-201 instructions or the WIFI-201 quick start guide please visit:
www.NeuLog.com; Choose "Products" on the main menu,
then choose "WiFi Communication module".
6. The WIFI-201 indicator lights will flash; take no action until the LED to the far left
turns blue; this can take up to one minute.
7. Take your tablet or smart phone, go to the WiFi settings and select the NeuLog
network (NeuLog0184 for example) which matches the ID found on the back of
the WIFI-201 module (0184 for example).
8. Give your device about 20 seconds to connect to the WIFI-201 module.
9. Once the device is connected, go to your browser and type the website
wifi201.com into the URL bar, then wait for 30-60 seconds.
10. You will see a “Control mode” icon in the application, click on it.
11. The application will then load a new screen and begin to auto detect the
sensor(s); this can take a minute. (You can stop the search when the sensor is
found.)
12. If the application does not auto detect the sensor(s), select “Search for sensors”.
13. Once the sensor is found you will see a module box on the left side of the screen
for the temperature sensor. In this box, real time data will be displayed.
14. Click on the “Module setup” button located in the temperature sensor module
box to change the temperature probe settings if need be.
15. Click on the “Experiment setup” icon to change the experiment settings if need
be (Experiment duration for example).
16. To run an experiment and collect data, click on the “On-Line experiment” icon,
then click the "Run experiment" icon.
17. If you have a newer generation WIFI-201 module (with the USB icon on the
cover) this can be used as a USB-200, meaning you can tether the probes
directly to the computer using the WIFI-201. To engage operation in this fashion,
press 3 times on the panel button. Repeating this operation will return the
module to WiFi mode.
Operation with NeuLog Graphic Display Module (viewer)
Materials needed:
NUL-210 Pressure Sensor
VIEW-101 Viewing Module
BAT-200 Battery
Procedure:
1. Connect the pressure sensor to the left side of the viewer.
2. Connect the BAT-200 module to the right side of the viewer.
3. The VIEW-101 will auto detect the sensor and you will see it appear on the left
side of the screen.
4. Once the sensor appears it will be monitoring data in real time.
5. To run an experiment and collect data press the run icon (little green person).
Off-line experiments
(Off-line experiments are when you do not have a sensor connected directly to a
computer, tablet, smartphone, or NeuLog viewer).
Materials needed:
NUL-210 Pressure Sensor
BAT-200 Battery Module
Materials needed to configure your offline experiment:
USB-200 Module, WIFI-201 module or VIEW-101 Module
USB to mini USB cable (included with the USB-200 module)
Procedure:
1. To determine the experiment settings, first connect to your chosen device (PC,
Mac, tablet, smart device) and click on the “Off-line experiment” icon after the
sensor search has ended. (For more information on how to change the
experiment settings, view the quick start procedure section for your chosen
device in this document.)
2. Connect the pressure sensor directly to the left side of a charged BAT-200
module.
3. When ready to collect data, press the “Start/Stop” button on the pressure sensor;
a red light will turn on for the duration of the experiment.
NEULOG PRESSURE LOGGER SENSOR GUIDE
4. After the experiment has concluded (the “Start/Stop” button is pressed again or
the data collection period ends) connect the sensor to your chosen device (you
can find full instructions in each device’s quick start procedure section).
5. Open the NeuLog application.
6. Click the “Off-line experiment” icon.
7. Click the “Load data from sensors” icon.
8. Select which experimental data to upload (5 experimental runs can be stored at
one time on the NUL-210 pressure sensor).
Restoring sensor’s factory default settings:
Procedure:
1. Connect the USB-200 module to a PC, Mac, tablet, or smart device.
2. Connect the pressure sensor to a USB-200 module (they directly plug together.
3. Open the NeuLog application.
4. Click the “Tools” icon.
5. Click the “Restore sensor’s factory defaults” on the menu.
Included with the sensor:
NeuLog NUL-210 Pressure Sensor Guide (this document)
A probe with an attachment at the end
A hose that can be attached to the probe, for easy connections (to a syringe for
example)
Sensor specifications
atm
psi
kPa
bar
Range and
operation modes
0 to 7
0 to 100
0 to 700
0 to 7
ADC resolution
16 bit
Accuracy
±1%
Resolution
0.01
0.1
0.1
0.01
Max sample rate
(S/sec)
100
The accuracy regards a working interval between 20 °C and 30 °C
Experiment Duration: 1 second to 31 days.
Sensor features:
Fully digital data
Rugged plastic ergonomic case
Push button switch for Start/Stop experiments in off line mode
LED indicator of experiment status (blinks while collecting data)
Pre-calibrated internal sensing equipment
The probe and the additional hose allow for easy connections to various openings
Note: NeuLog products are intended for educational use.
Videos and experiment examples:
Videos, literature and other probes can be found at www.NeuLog.com.
In order to access the pressure sensor's page, choose "Products" on the main
menu and then "Pressure logger sensor".
In order to find the science experiments, choose "Experiments" on the main
menu of the NeuLog website, then choose "Physics", "Chemistry", "Biology" or
"Environmental Science".
Biology Experiment:
oEnzyme Activity (B-7)
Chemistry Experiments:
oGay-Lussac’s Law (C-14)
oBoyle’s Law (C-30)
Technical background:
The philosophy behind NeuLog’s plug and play technology is based on each sensor’s
ability to store its own data due to an internal flash memory chip and micro-controller
in each plastic NeuLog body. This technology allows the sensor to collect and then
store the digital data in the correct scientific units (oC, oF, Lux, %, ppm, for example).
The sensor is pre-calibrated at the factory. The built-in software in the logger can be
upgraded for free at any time using the provided firmware update.
The pressure sensor uses the piezoresistive effect. The transducer is based on silicon
between metal foils that changes its resistance according to pressure. One side of it is
at complete vacuum that enables to measure the absolute pressure on its other side.
NEULOG PRESSURE LOGGER SENSOR GUIDE
This transducer is built as a strain gauge with Wheatstone bridge circuit so its output is
a voltage that depends on its absolute pressure.
Maintenance and storage:
Never submerge the NeuLog plastic body in any liquid.
Do not allow liquid into the NeuLog plastic body.
After using the probe, wipe off all excess material, liquid or residue from the
sensor.
Store in a box at room temperature out of direct sunlight.
Warranty:
We promise to deliver our sensor free of defects in materials and workmanship. The
warranty is for a period of 3 years from the date of purchase and does not cover
damage of the product caused by improper use, abuse, or incorrect storage. Sensors
with a shelf life such as ion selective probes have a warranty of 1 year. Should you
need to act upon the warranty, please contact your distributor. Your sensor will be
repaired or replaced.
Thank you for using NeuLog!
Flexible, simple, fast, forward thinking.
W: www.neulog.com
E: info@neulog.com
A: 850 St Paul Street, Suite 15, Rochester, NY 14605
P: 1.866.553.8536
V11042014

Other NeuLog Accessories manuals

NeuLog NUL-227 User manual

NeuLog

NeuLog NUL-227 User manual

NeuLog NUL-237 User manual

NeuLog

NeuLog NUL-237 User manual

NeuLog NUL-206 User manual

NeuLog

NeuLog NUL-206 User manual

NeuLog NUL-228 User manual

NeuLog

NeuLog NUL-228 User manual

NeuLog NUL-235 User manual

NeuLog

NeuLog NUL-235 User manual

NeuLog NUL-230 User manual

NeuLog

NeuLog NUL-230 User manual

NeuLog NUL-233 User manual

NeuLog

NeuLog NUL-233 User manual

NeuLog NUL-225 User manual

NeuLog

NeuLog NUL-225 User manual

NeuLog NUL-223 User manual

NeuLog

NeuLog NUL-223 User manual

NeuLog NUL-219 User manual

NeuLog

NeuLog NUL-219 User manual

NeuLog NUL-225 User manual

NeuLog

NeuLog NUL-225 User manual

NeuLog NUL-206 User manual

NeuLog

NeuLog NUL-206 User manual

NeuLog NUL-231 User manual

NeuLog

NeuLog NUL-231 User manual

NeuLog NUL-201 User manual

NeuLog

NeuLog NUL-201 User manual

NeuLog NUL-215 User manual

NeuLog

NeuLog NUL-215 User manual

NeuLog NUL-214 User manual

NeuLog

NeuLog NUL-214 User manual

NeuLog NUL-209 User manual

NeuLog

NeuLog NUL-209 User manual

NeuLog NUL-236 User manual

NeuLog

NeuLog NUL-236 User manual

NeuLog NUL-216 User manual

NeuLog

NeuLog NUL-216 User manual

NeuLog NUL-243 User manual

NeuLog

NeuLog NUL-243 User manual

NeuLog NUL-232 User manual

NeuLog

NeuLog NUL-232 User manual

NeuLog NUL-235 User manual

NeuLog

NeuLog NUL-235 User manual

NeuLog NUL-205 User manual

NeuLog

NeuLog NUL-205 User manual

NeuLog NUL-227 User manual

NeuLog

NeuLog NUL-227 User manual

Popular Accessories manuals by other brands

Adexa JC-88 user manual

Adexa

Adexa JC-88 user manual

IMMAX NEO Soil Sensor user manual

IMMAX

IMMAX NEO Soil Sensor user manual

turck RU100-CP40 Series quick guide

turck

turck RU100-CP40 Series quick guide

Kele LX-24 installation instructions

Kele

Kele LX-24 installation instructions

MaxQ MaxPlus Alpha 2.0 Training manual

MaxQ

MaxQ MaxPlus Alpha 2.0 Training manual

Kasanova MAS022075 instruction manual

Kasanova

Kasanova MAS022075 instruction manual

Honeycomb DASH75 user manual

Honeycomb

Honeycomb DASH75 user manual

Honeywell WPS Series quick start guide

Honeywell

Honeywell WPS Series quick start guide

LEGRAND Wattstopper EW-200-120 installation instructions

LEGRAND

LEGRAND Wattstopper EW-200-120 installation instructions

Lanberg SM01-WP10 user manual

Lanberg

Lanberg SM01-WP10 user manual

POL-EKO SMART ILP 53 instruction manual

POL-EKO

POL-EKO SMART ILP 53 instruction manual

Eisco GGSN-10 instructions

Eisco

Eisco GGSN-10 instructions

Panasonic MA2J112 (MA112) Specification sheet

Panasonic

Panasonic MA2J112 (MA112) Specification sheet

Oregon Scientific THGR328NH user manual

Oregon Scientific

Oregon Scientific THGR328NH user manual

Wire wizard HHSS instruction manual

Wire wizard

Wire wizard HHSS instruction manual

PCB Piezotronics M117B13 Installation and operating manual

PCB Piezotronics

PCB Piezotronics M117B13 Installation and operating manual

Dacor PF36BNDFXX* installation instructions

Dacor

Dacor PF36BNDFXX* installation instructions

Lennox CS user guide

Lennox

Lennox CS user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.