Hi-ESonyc
7 of 68
-Do not install the system near a fire. Doing so could cause an accident or
deformation.
-Always pay attention to the power, voltage and current (power consumption)
-Use a 230V power outlet exclusively.
Ca p.4 P R E CA U T I ON S B E F OR E U S E
- Do not use this apparatus with an electrocardiograph or other medical devices
-Use extreme caution when using this apparatus with other diagnostic devices, since
such use could result in incorrect diagnosis.
-The simultaneous use of this apparatus with other instruments may cause burns on the
skin under the electrode stimulation or damage the stimulation unit. Avoid this kind of
combined use.
- Except for the ultrasound probe, do not perform treatments with wet hands. This may
cause electric shock.
-Designate an administrator in charge of the unit. Only qualified personnel should
adjust the device.
-With the exception of the area to be treated, do not place conductive metal parts in
contact with the head of the ultrasound probe. This may cause electric shock.
CAUTION When installing the unit, pay attention to the following aspects:
-Avoid placing the system in a location where the apparatus can be reached by
splashing water
- Avoid placing the system where it may be affected by atmospheric pressure,
temperature, humidity, sunlight, dust, sulphur or any other adverse factors.
- Ensure that the system is stable. Do not tip the apparatus. Avoid vibrations and
impacts (this also applies to the transport).
- Avoid flammable atmospheres, flammable anaesthetic gases combined with oxygen,
nitrate, air, flammable detergents or disinfectants combined with air.
- Avoid places where chemicals are stored or where they might leak gas.
- Check the voltage, frequency and the allowed current (or energy consumption) for the
power supply unit.
-In order to avoid accidents due to a distortion of the main unit and accessories, keep
the apparatus away from flames or fire.
-If you use the apparatus at a short distance from a product that generates a loud
noise, proximity may change the parameters. Take appropriate action, such as moving
the apparatus to a safe distance from such noise.
-Make sure that all cables are connected correctly and securely.
-Do not connect this system to individuals already connected to surgical devices.
-Do not use components from other equipment for the therapy in order not to cause an
accident.
-Carefully recheck the probes and electrodes that come into direct contact with the
patient.
-If the patient should feel an unusual sensation or suffer from a rash, redness, itching,
or other unusual symptoms during treatment, immediately discontinue therapy and
take the appropriate action.
-When attaching the plug to the socket, make sure the apparatus is switched off.