Mainmenu Menuvalue Name Description
Pulse Pulse multiplayervalue Whatvalue 1 pulse means in display.Value can
include decimals.
Divide Value ofpulse divider Used in special case when there is notpossible to use
multiplayer to setenough decimals. See example*.
Start Value where counting starts
Limit1 Alarmlevel 1 Countervalue when the alarm 1 pulls.
No Closing contact, alarm 1
Nc Opening contact,alarm 1
Adjust Start Startvalue in quicksetup.
Limit1 Limit1value in quicksetup
Loop On Loop function in use
Off Loop function notin use
Limit2 Alarmlevel 2 Countervalue when the alarmrelay2 pulls.
On Alarmlevel 2 depends the
alarmlevel 1. Value ofthe alarmlevel 1 added to a alarmlevel 2,after
the combined value alarm 2 pulls.
Off Alarmlevel 2 is absolut. Alarmlevel 2 function is exactlylike alarmlevel 1.
No Closing contact, alarm 2
Nc Opening contact,alarm 2
Divout Value ofdivider States how manypuses needed to pull alarm.
Limit2 Relay2 = alarmrelay,Relay3 =
divide out
Divout Relay2 = divide out,Relay3 =
alarm 3
On Esternal resetprohibited.
Off Esternal reset allowed.
On Start/ Limitvalue inspection.
Off Inspection is notused.
On Relays in alarm state after the power up (untill reset).
Off Relays working normallyafter power up.
Up Counting up
Down Counting down
OFF No external contact in use.
revers Countdirection selection.
Step External contactsteps backto previous value.
SlotB I/O-card in slotB,external contactin line 4.
SlotC I/O-card in slotC,external contactin line 4.
NC External switch contactselection,normallyclosed.
NO External switch contactselection,normallyopen.
Dec Number ofdesimals How manydesimals are shown in display.
Int 0…15 Intensityof display. Change the displayintensityfrom 0 to 15.
NPN (Contact) Sensortype selection
PNP
Namur
Pickup
Baud r 300…19200 Baud rate Baud rate for serial interface:300...19200
Addres Addre 0…127 Serialaddress Serialdata address selection:0…127
Off RS485 notin use
SlotB RS485 used in slotB.
Save XSave the changes to memory.
Undo XCancels selections.
Cont 1
PO res
Check
Res bl
When reseting counter,first pulse brings the value of
what is selected in Adjust setting (Start or Limit1).
Second resetpulse clears the counter value.
Slot
Slot c
Cont 2
Direct
E Swit
ST
- moving up/down in menu,X
- change settings/move to a nextlevel,Ì
-
accept/return back
Type of the pulse sensor.
NOTE !Ifclosing contactis used,please selectsensor
to NPN.
Starting value (Start) or counting alarm value (Limit1)
can be change directlyfrom displaywithoutentering
inside menu.
With function Loop (On)counter reset's to zero and start
automaticallynew counting untill the alarm (Limit1) is
achieved.
External resetcontact lock while counting. Reset can be
done after the alarmlevel is achieved.Doesen'taffect
reseting from the frontpanel.
Alarm 1 relayposition setup.
Follow
Alarm 2 realyposition setup.
REL2 Relay2 and relay3 setup,here you can switch relay2
and relay3 funtions among themselves.
RS485 serialdata-card selection.NOTE !ifRS232 is
used you doesen'tneed to make this selection.
You can jump to Save and Undo selection in
mainmenu using Ì-button.Selection is confirmed with
X-button.
Selection ofwich direction the counter startcounting,
up or down.
Sensor
RS-485
Mode
Programmenu