29. 10. 20. Document Number 671420Nuaire | Western Industrial Estate | Caerphilly | CF83 1NA |nuaire.co.uk
NA
Installation Manual
1.2 Important Information
This manual contains important information on the safe and
appropriate assembly, transport, commissioning, operation,
maintenance, disassembly and simple troubleshooting of the product.
While the product has been manufactured according to the accepted
rules of current technology, there is still a danger of personal injury or
damage to equipment if the following general safety instructions and
the warnings contained in these instructions are not complied with.
•Read these instructions completely and thoroughly before
working with the product.
•Keep these instructions in a location where they are accessible
to all users at all times.
•Always include the operating instructions when you pass the
product on to third parties.
1.3 Personal Protective Equipment
The following minimum Personal Protective Equipment (PPE) is
recommended when interacting with Nuaire product:
•Protective Steel Toed Shoes - when handling heavy objects.
•Full Finger Gloves (Marigold PU800 or equivalent) - when
handling sheet metal components.
•Semi Fingerless Gloves (Marigold PU3000 3DO or equivalent)
- when conducting light work on the unit requiring tactile
dexterity.
•Safety Glasses - when conducting any cleaning/cutting operation
or exchanging filters.
•Reusable Half Mask Respirators - when replacing filters which
have been in contact with normal room or environmental air.
Nuaire would always recommend a site specific risk assessment by a
competent person to determine if any additional PPE is required.
2.0 INTRODUCTION
This range of slimline axial fans incorporates several different models.
These IPX4, splash proof fans are specifically designed to ventilate small
rooms, such as toilets, bathrooms, shower rooms, utility rooms and
kitchens. They are ideal for wall, ceiling or panel installation and extract
directly to outside or through a short length of ducting.
Unit Codes Operation Type Weight
(Kg)
NA100 4” Axial with remote switch operation. 0.5
NA100PC 4” Axial with pull cord operation. 0.5
NA100T 4” Axial with remote switch operation
and integral overrun timer. 0.5
NA100HT 4” Axial with integral humidistat
operation and overrun timer. 0.5
NA100PIR 4” Axial with integral passive infrared
sensor and overrun timer. 0.5
NA100-12 12V version of 4” Axial with remote
switch operation. 0.5
NA100T-12 12V version of 4” Axial with pull cord
operation. 0.5
NA150 6" Axial with remote switch operation. 1.5
NA150PC 6" Axial with pull cord operation. 1.5
NA150T 6" Axial with remote switch operation
and integral overrun timer. 1.5
NA150HT 6" Axial with integral humidistat
operation and overrun timer. 1.5
Unit Codes Operation Type Weight
(Kg)
NA150PIR 6" Axial with integral passive infrared
sensor and overrun timer. 1.5
3.0 MECHANICAL INSTALLATION
Installation must be completed by competent persons, in accordance
with good industry practice and should conform to all governing and
statutory bodies i.e. IEE, CIBSE, etc.
This product should not be used in an ambient temperature higher than
40°C (104°F) and should not be exposed to atmospheric agents (rain,
sun, snow, etc). The product or any part of it should not be placed in
water or other liquids.
1 2 3 4 5
678 6mm dia.
1 Unit Components
9
2 Wall Installation to Outside Grille
3.1 Component Key
1. Front Cover
2. Wall Fixing Screws
3. Motor Fan Assembly
4. Front Cover Fixing Screw
5. Wall Plug
6. Cable Grommet
7. Cable Clamp
8. Cable Fixing Screws
9. Outside Grille
A neon indicator is incorporated on the front of some models to
indicate the fan is operating.