NZR ZMZ 0205 How to use

NZR – Ihr Partner für Energiemessung 11
7HFKQLVFKHQGHUXQJHQYRUEHKDOWHQ7HFKQLFDOGHWDLOVVXEMHFWWRFKDUJH0RGLȴFDWLRQWHFKQLTXHVU«VHUY«HV5LVHUYDGLPRGLȴFKHWHFQLFKH
Inhalt / Directory / Sommaire / Indice
ZMZ 0205 / ZMZ 0215
Deutsch ............................................................................................................................ 3
English
1. Safety / functional description / assembly ......................................................................................... 12
1.1. Safety instructions............................................................................................................................. 12
1.2. Functional description...................................................................................................................... 13
1.2.1. Improper use................................................................................................................................. 13
1.3. Assembly ZMZ 0205 / ZMZ 0215................................................................................................... 13
2. Short manual ZMZ 0205
2.1 Settings ................................................................................................................................................ 13
2.2 Time setting ........................................................................................................................................ 14
2.3 Display .................................................................................................................................................. 14
3. Special features
3.1 Coin register (Option „A“) ................................................................................................................. 14
4. Short manual ZMZ 0215
4.1 Settings ................................................................................................................................................ 14
4.2 Running time ...................................................................................................................................... 15
4.3 Number of coins ................................................................................................................................ 15
5. Special features
5.1 Lag time (Option „Q2“) ..................................................................................................................... 16
5.2 Advance time (Option „Q1“) ............................................................................................................ 16
5.3 External start / External stop (Option „S“) ................................................................................... 16
5.4 Door unlock (Option „M“) ................................................................................................................ 16
5.5 Coin register (Option „A“) 6-digit .................................................................................................... 16
5.6 Elapsed time meter (Option „V“) .................................................................................................... 17
5.7 Multiple coin validator (Option „O“) .............................................................................................. 17
6. Technical data
6.1 ZMZ 0205 ............................................................................................................................................ 17
6.2 ZMZ 0215 ............................................................................................................................................ 17
7. Maintanace.................................................................................................................................................... 17
8. Warranty ....................................................................................................................................................... 18
9. Wiring diagram and scale drawing ......................................................................................................... 18
10.Option overview .......................................................................................................................................... 19
11 EU Declaration of Conformity................................................................................................................... 39
Français ........................................................................................................................... 20
Italiano ............................................................................................................................. 29
NZR Technical Support
Phone +49 5424 2928-0
Email [email protected]

NZR – Ihr Partner für Energiemessung
7HFKQLVFKHQGHUXQJHQYRUEHKDOWHQ7HFKQLFDOGHWDLOVVXEMHFWWRFKDUJH0RGLȴFDWLRQWHFKQLTXHVU«VHUY«HV5LVHUYDGLPRGLȴFKHWHFQLFKH
12
1. Safety / functional description / assembly
1.1. Safety instructions
Connection: ATTENTION! Before accessing the terminals, all power circuits
PXVWEHVZLWFKHGR
• The connection must be provided by the customer with a disconnecting device
that has a contact opening width in accordance with the overvoltage category III
full disconnection conditions.
• Lead the connecting cables through the cable grommets.
• For ease of wiring, the left part of the connector is removable. The terminal as-
signment is printed on the terminal cover.
• Connection acc. according to the wiring diagram (Fig. 1 - 5).
• When reassembling the connector, make sure it clicks securely.
• Replace the terminal cover.
• Mains connection and access to the service area may only be carried out by qua-
OLȴHGSHUVRQQHO
Note: Only use the supplied plastic screw to attach the terminal cover.
ATTENTION!
This device may be used by children 8 years old and above and by persons with
reduced physical, sensory or mental capabilities or lack of experience and know-
ledge, if they have been supervised or instructed in the safe use of the device and
understand the resulting hazards. Children are not allowed to play with the device.
Cleaning and user maintenance must not be performed by children without supervi-
sion.
For independent installation of spare parts or other changes
H[SLUHVDQ\ZDUUDQW\DQGWKH79DQG*6DSSURYDORIDHFWHGGHYLFH
Security Alert:
In order to avoid personal injury and damage to property, it must be ensured that
no water can penetrate before opening the device (for example, for coin clearing).
Safety extra-low voltage (option „L“)
When operating in wet areas, the connection with safety extra-low voltage 24 V is
recommended. For this purpose a 24 V AC voltage should be fed into the wet area.
Transformers 230V / 24V 100 VA for up to 4 ZMZ controllers are available ex works.
For on-site use, a safety transformer must be provided.
1.2. Functional description
Short Manual
ZMZ 0205 / ZMZ 0215
ENG

NZR – Ihr Partner für Energiemessung 13
7HFKQLVFKHQGHUXQJHQYRUEHKDOWHQ7HFKQLFDOGHWDLOVVXEMHFWWRFKDUJH0RGLȴFDWLRQWHFKQLTXHVU«VHUY«HV5LVHUYDGLPRGLȴFKHWHFQLFKH
2. Short manual ZMZ 0205
2.1 Settings
The ZMZ 0205 is equiped with a 1-digit LED to
display the number of inserted coins or remai-
ning time. Up to two coins can be insered into
the device at once.
Additional coins do not lengthen the
remaining time.
Afreshing of time can only occur after the termi-
nation of time. Time base can be switched from
HH:MM to MM:SS.
Delivery status
Jumper 1 open
only one coin will be accepted
Jumper 2 open
Upper Dip for setting of minutes
Lower Dip for setting of hours
Münzprüfer
Münzenzählwerk
B
1
B
2
Dip-oben
Dip-unten
12481632
The ZMZ device family is used to bill various electrical consumers. Payment is made
by coins or tokens. The coin counter can be adjusted by the customer. You can set
the release time and the number of coins. After inserting the coins, the number of
coins entered appears on the display. At the same time the main relay switches on.
:KHQWKHUHOHDVHWLPHH[SLUHVWKHPDLQUHOD\VZLWFKHVRDJDLQ
1.2.1. Improper use
The product is not suitable for use in the food industry. The maximum switching
capacities or permissible currents of the respective relays / contactors must not be
exceeded. The switching of safety-critical consumers is not permitted.
1.3. Assembly ZMZ 0205 / ZMZ 0215
• Drill mounting holes according to dimensional sketch (Fig. 6 - Dimensional and
circuit diagrams)
• $IWHURSHQLQJWKHGHYLFHDQGUHPRYLQJWKHFRQQHFWLRQFDSWKHGHYLFHFDQEHȴ[HG
to the wall with the enclosed screws.
• It is essential to pay attention to vertical seating to ensure proper operation of the
coin validator.
Circuit board ZMZ 0205

NZR – Ihr Partner für Energiemessung
7HFKQLVFKHQGHUXQJHQYRUEHKDOWHQ7HFKQLFDOGHWDLOVVXEMHFWWRFKDUJH0RGLȴFDWLRQWHFKQLTXHVU«VHUY«HV5LVHUYDGLPRGLȴFKHWHFQLFKH
14
Alternative settings
Jumper 1 closed
Insertion of two coins available
Jumper 2 closed
Upper Dip for setting of seconds
Lower Dip for setting of minutes
Value of Dip-switch:
1 – 2 – 4 – 8 – 16 – 32
Notice
To secure the activation of basic-settings and time-settings, it is essentisal to cut the
GHYLFHIURPSRZHUVKRUWO\2QȴUVWXVDJHWKH/('ZLOOȵDVKIRXUGLJLWVIROORZHGE\
a break. The combination of digits indicates the installed software. The permanent
display of the digit „0“ indicates the ready-status.
2.2 time setting
To set the running time, the imprinted values of DIP-switches set to „on“ position has
to be added.
E.G. Upper-DIP-switch
switch 1, 3 and 4 set to „on“
The result of addition of imprinted values is 13
In addiction of basic setting, the running time is set to 13 minutes or 13 seconds.
Lower-DIP-switch
switch 2 and 5 set to „on“
The result of addition of imprinted values is 18
In addition with the values of the upper-DIP-switch the total running time is 18 minu-
tes and 13 seconds or 18 hours and 13 minutes.
2.3 Display
$IWHULQVHUWLRQRIȴUVWFRLQDȌȊLVGLVSOD\HG$IWHULQVHUWLRQRIDVHFRQGFRLQLIDFWL-
vated) a „2“ is displayed. The display will jump back to „1“ if the time stock of second
coin is used up. When time stock reaches the last 9 minutes the remaining time
ȵDVKHVRQGLVSOD\LQRQHPLQXWHVWHSVΖIWKHUXQQLQJWLPHSHUFRLQLVVHWWRDORZHU
YDOXHWKDQPLQXWHVWKLVWLPHZLOOȵDVKRQGLVSOD\
3. Special features ZMZ 0205
3.1 Coin register (Option „A“)
When ordering „Option A“ a mechanical 5-/6-digit non-resetable roller counter is
PRXQWHGRQWKHFRYHUIRUUHJLVWUDWLRQRIDOOLQVHUWHGFRLQV7KLVRSWLRQLVUHWURȴWWDEOH
by factory easily.

NZR – Ihr Partner für Energiemessung 15
7HFKQLVFKHQGHUXQJHQYRUEHKDOWHQ7HFKQLFDOGHWDLOVVXEMHFWWRFKDUJH0RGLȴFDWLRQWHFKQLTXHVU«VHUY«HV5LVHUYDGLPRGLȴFKHWHFQLFKH
Münzprüfer
Prozessor
EPROM
Einstellungen
4. Short manual ZMZ 0215
4.1 Settings
For all settings the four buttons on side-
cut-out of terminal cover are used. Press
button „Betrieb“ before and after every
change of settings. „Außer Betrieb“ is
GLVSOD\HGDIWHUȴUVWSXVKLQJWKHEXWWRQ
„Reset“ follwed by version number of
software is displayed after pushing the
button in normal operation. All change-
able values can be displayed by multiple
pushing of button „Menü“.
Depending on version the following
information are displayed:
„Zeit“ (time) (running time)
„Münzen“ (coins) (number of coins)
optional „Nachlauf“ (lag) (lag of 2nd relay)
optional „Vorlauf“ (advance) (start delay)
optional „ext. Start“ (start with external button)
optional „ext. Stop“ (stop with external button)
4.2 Setting of running time
Within the menu „Zeit“ the cursor (underscore) can be scrolled to the position by
multiple pushing the button „Auswahl“.
Push the button „Ändern“ to set the value of basic time in HH : MM : SS.
Push the button „Betrieb“ to return to operation mode or „Menü“ for next setting.
4.3 Number of coins
Calling up the menu „Münzen“ set the number of coins needed to start the device by
pushing the „Ändern“ button. Refer to 4.2 for further settings.
Circuit board ZMZ 0215

NZR – Ihr Partner für Energiemessung
7HFKQLVFKHQGHUXQJHQYRUEHKDOWHQ7HFKQLFDOGHWDLOVVXEMHFWWRFKDUJH0RGLȴFDWLRQWHFKQLTXHVU«VHUY«HV5LVHUYDGLPRGLȴFKHWHFQLFKH
16
5. Special features ZMZ 0215
5.1 Lag time (Option “Q2“)
Set the lag-time of the second relay within the menu „Nachlauf“ as mentioned above.
Function is deactivated by setting value to „0“.
Notice
The lag-relay only needs to be operated with the identical voltage as the main relay
on circuit board. (Also valid for option „C2“)
5.2 Advance time (Option “Q1“)
Set advance-time within the menu „Vorlauf“ as mentioned above.
Function is deactivated by setting value to „0“.
5.3 External start / external stop (Option “S“)
7KHIXQFWLRQVFDQEHVZLWVFKHGRQRURE\SXVKLQJWKHȌQGHUQȊEXWWRQZLWKLQWKH
menu „ext. Start“ or „ext. Stop“. The device is equiped with plug-in for an external
switch on the upper terminal cover if these options are installed. Keep in mind to use
a shielded control cable of max. 3m length to connect the switch.
5.4 Door unlock (Option „M“)
To unlock electrical doors of washing machines without insertion of a coin, the device
can be equiped with an additional button. After the basic time passed out, the power
can be switched on again for one minute by pushing the button to open the door.
„Taste/Münze“ is diplayed while activated.
5.5 6-digit coin register (Option „A“)
Push button „Betrieb“ and „Auswahl“ to read out the number of inserted coins.
Mz number quantity of inserted coins since last reset,
inserted amount of money at option „O“ (tokens ntot added)
GMz number Quantity of all inserted coins since start of operational time
(not resetable)
amount of money at option „O“. You can switch between options by
pushing the „Menü“ button. Only the Mz Zahl is reset by pushing the
„Ändern“ button to request the „Löschen?“ display.
5.6 Elapsed time meter (Option „V“)
If the device is equipped with option „V“ go ahead like described under 5.5. In additi-
on the following registers are displayed:
FSZ Activation time in hours since last reset
GFSZ Total activation time since start of operation (not resetable)
Alarm message
In case of jammed coin caused by a cramped cash box „Fehler“ is
displayed. Reset the device by pushing the „Betrieb“ button longer.

NZR – Ihr Partner für Energiemessung 17
7HFKQLVFKHQGHUXQJHQYRUEHKDOWHQ7HFKQLFDOGHWDLOVVXEMHFWWRFKDUJH0RGLȴFDWLRQWHFKQLTXHVU«VHUY«HV5LVHUYDGLPRGLȴFKHWHFQLFKH
5.7 Multiple coin validator (Option „O“)
Option „O“ is an electronical coin validator programmed for standard Euro coins
(0,10; 0,20; 0,50; 1,00; 2,00 €) and tokens. The insertable Euro amount can be set in
menu „Münzen“ as mentioned in 4.2. (The tokens are available under item no. 2020
for WMA).
6. Technical data
6.1 Technical data ZMZ 0205
Voltage 230 V ~ 50 Hz
Consumption 1,5 W
Switching power max. 10 A (16 A at AC 1)
min. 20 mA (relay „short-circuited“ with noise suppression
capacity) Without load, measurable reactive voltage is present.
Protection category IP 31
Protection class 1
Dimension (WxHxD) 185 x 238 x 150 mm
Weight ca. 3,0 kg
6.2 Technical data ZMZ 0215
Voltage 230 V ~ 50 Hz
Consumption 3,6 W
Switching power max. 10 A (16 A at AC 1)
min. 20 mA (relay „ short-circuited“ with noise suppression
capacity) Without load, measurable reactive voltage is present.
With contractor 3x 20 A (3x 20 A at AC 1)
Protection category IP 31
Protection class 1
Dimension (WxHxD) 185 x 238 x 150 mm (wall mounted)
[[PPȵXVKPRXQWHG
Weight ca. 3,0 kg
7. Maintenance
The devices are maintenance-free. Only the coin slot should be cleaned with a brush
time-to-time.
8. Warranty
:HRHUDPRQWKZDUUDQW\RQWKHIXQFWLRQRIWKHGHYLFH7KHZDUUDQW\LVVWULFWO\
limited to technical defects of the device. Further receivables can not be accepted. In
addition the „GENERAL CONDITIONS FOR THE SUPPLY OF PRODUCTS AND SERVICES OF
THE ELECTRICAL AND ELECTRONICS INDUSTRY“ are relevant. Any kind of warrenty and
WKH79DQG*6DSSURYDOH[SLUHVLIVSDUHSDUWVZLOOEHLQVWDOOHGRUDQ\RWKHUPRGLȴFDWLRQV
are made by unauthorised persons.

NZR – Ihr Partner für Energiemessung
7HFKQLVFKHQGHUXQJHQYRUEHKDOWHQ7HFKQLFDOGHWDLOVVXEMHFWWRFKDUJH0RGLȴFDWLRQWHFKQLTXHVU«VHUY«HV5LVHUYDGLPRGLȴFKHWHFQLFKH
18
9. Wiring diagram and scale drawing
Consumer connection with
potential-free relay contact Direct consumer connection Three-phase consumer
connection via contactor
Option L
Safety low-tension 24 V
Option Z
Electronical time control for shower
potential-free
relay contact
consumer consumer
consumer
18 m5m
3 m
0m30 mm
45 mm
85 mm
50 mm
Gehäuse ohne Rahmen
25m
m3
Gehäuse mit Rahmen
0m20 m
284 mm
127 mm
240 mm
Consumer connection with
potential-free relay contact Direct consumer connection Three-phase consumer
connection via contactor
Option L
Safety low-tension 24 V
Option Z
Electronical time control for shower
potential-free
relay contact
Dimensions
consumer consumer
consumer
Dimensions

NZR – Ihr Partner für Energiemessung 19
7HFKQLVFKHQGHUXQJHQYRUEHKDOWHQ7HFKQLFDOGHWDLOVVXEMHFWWRFKDUJH0RGLȴFDWLRQWHFKQLTXHVU«VHUY«HV5LVHUYDGLPRGLȴFKHWHFQLFKH
10. Option overview
Available Options Item no. ZMZ 0205 ZMZ 0215 ZMZ 0215
Wash‘n Dry LMZ 0115* LMZ 0232* LMZ
0236*/0436*
A6- / 5-digit coin counter 3000
5-digit
6-digit
Standard
B1 No coin acceptence during power outage 3010 -
C1 Acoustic signal before time laps can be set by
factory 3020 - ---
C2 With potential-free contact for e.g. external alarms 3021 - ---
D6ZLWFKRIXQFWLRQWLPHDGMXVWDEOH 3030 - ---
EKey-switch for moneyless release 3040
FTime stopp automatic at 100 mA 3050 - ----
G3-phase contactor 3 x 20 A (recommended from
2,2 kW) 3061
Standard ---
L24 V safety low voltage for humid areas 3120 ---
MPush-button for door release 3130 -
Standard ---
OMultiple coin tester**; release amount adjustable 3151 -
Q1 Lead time adjustable 3240 - ---
Q2 Relay for follow-up time, time adjustable 3250 - ---
SExternal start 3180 - ---
TBurglary protection with additional steel-bar 3200 Item no.
13201
USame lock as housing 3210
V6-digit operating hour counter 3190 -
ZElectonical time control for showers with included
1/2 inch magnetic valve and 230 V/24 V transformer 3280 ----
Coin insertion EURO coins Additonal item no. * valid for billing - calibrated design
0,10 Euro _ _ _ _ _ _ 69 Available special features (In case of misorders the withdrawal of
devices is excluded.)
0,20 Euro _ _ _ _ _ _ 70
0,50 Euro _ _ _ _ _ _ 71 Not in combination with option „L“, „G“ or „M“
1,00 Euro _ _ _ _ _ _ 72 $OUHDG\LQVWDOOHGGHYLFHVFDQRQO\EHUHWURȴWWHGDWWKHIDFWRU\
'HSHQGLQJRQWKHDSSOLFDWLRQLWPD\EHQHFHVVDU\WRUHWURȴWWKH
option „G“ (control contactor).
2,00 Euro _ _ _ _ _ _ 73
With option „O“ as default.
C1 and C2 only available separately, can not be combined.
Coin insertion Token Additonal item no. Note Option „G“ not available in combination with option „L“.
Standard token Ø 26 mm _ _ _ _ _ _ 74
3URȴOHWRNHQØ 25 mm _ _ _ _ _ _ 76 Time control for showers with magnetic valve
Please order tokens separately. • Option „Z“ is required if a 230 V connection is available at
installation place.
• Option „L“ and a magnetic valve 1/2“ (Item no. 5170) is required
if a 24 V connection is available at installation place.
• $GLHUHQWWUDQVIRUPDWRU9$9ΖWHPQRLV
required if one device should handle up to 5 showers with
magnetic valve.
Just contact us with any question!
Order note
In case of order note type and letter for recommended optional
features:
e.g. ZMZ 0205, 1,00€, A, T, Z
Item No. 70530172, 3000, 3200, 3280
3
3
4
4
1
2
1
2
3
4
Other manuals for ZMZ 0205
2
This manual suits for next models
1
Table of contents
Other NZR Timer manuals
Popular Timer manuals by other brands

Digital Game Technology
Digital Game Technology Backgammon Timer user manual

WESTEK
WESTEK TM13DOLB Instruction manual & warranty

Westinghouse
Westinghouse 28480 operating instructions

LEGRAND
LEGRAND EconoRex MT 499 83 manual

Theben
Theben LUNA 111 top3 AL operating instructions

TFA
TFA HAHN instruction manual