Olive Healthcare Bello User manual

REV 0 [12.10] SheLine-VRTM USER MANUAL | 1 00000XXX
Bello
USER MANUAL
-Model name: AD715-BWTW

OH-UM_Bello(Rev.0) Bello USER MANUAL | 2 Olive Healthcare Inc.
Overview
Copyright Rights
Intellectual property
Introduction
Notification / FCC Statement
Purpose/usage/reason of use prohibition/precautions
System symbol
User document
Rules used in user document
1. About product and its parts
1.1 About product
1.2 Composition and function of the product
1.3Indication used in manual and product
2.Preparation for use
2.1Matters to be checked before use
3.How to use
3.1 How to use product
3.2 Precautions for use
4.Product maintenance and
storage method
4.1 Precautions for management
4.2 Precautions for storage
5.Troubleshooting
5.1Failure specific actions
6. Overview of Warranty
6.1 Overview
6.2 Free warranty
6.3Warranty exclusions during free warranty period
7. Warranty
Warranty

OH-UM_Bello(Rev.0) Bello USER MANUAL | 3 Olive Healthcare Inc.
Overview
Copyright Rights
Copyright ⓒ 2018 Olive healthcare Corporation
Theproducts and theirassociated rightsreferred to in this document are protected by various intellectual
property rights, including the Industrial Property Rights Act and copyright, and unauthorized reproduction or
use shall be prohibited without the written consent of the company's Olive Healthcare.
.
Intellectual property
Bello and related intellectual property rights referred to in this document include patents and trademarks in
all countries applied to the world, including Korea, and all rights to them are protected by such intellectual
property rights.
The productsmentioned in this document are subject to the protection of our intellectual property rights,
including the patent rights below, the family patents and trademarks, and thus we inform that unauthorized
useof these products can bepunished in civil and criminal cases as they constitute a violationof our
intellectual property rights
Patentapplicationin Korea
Trademark registered in Korea
Design application in Korea
International application patent

OH-UM_Bello(Rev.0) Bello USER MANUAL | 4 Olive Healthcare Inc.
Introduction
Notification
Measurements obtained using the device cannot substitute for the care of a medical professional and cannot be
used to diagnose. However, it is intended to provide patients with continuous information on abdominal fat so
that can manage changes and maintain their abdominal fat rate independently, and to help with diagnosis and
treat during consultation with a physical. The equipment can be used at home or in a professional medical
institution
FCC Statement
FCC Part 15.19
This device complies with part15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
FCC Part 15.21
Any changes or modifications (including the antennas) to this device that are not expressly approved by the
manufacturer may void theuser's authority to operate the equipment.
FCC RF Radiation Exposure Statement:
This equipment complies with FCC RF Radiation exposure limits set forth for an uncontrolled environment.
This device and its antenna must not be co-located or operating in conjunction with any other antenna or
transmitter.
FCC Part 15.105
Note : This equipmenthas been tested and foundto comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications, However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different fromthat to which thereceiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Modifications not expressly approved by the manufacturer could void your authority to operate the equipment
under FCC rules.

OH-UM_Bello(Rev.0) Bello USER MANUAL | 5 Olive Healthcare Inc.
Introduction
Purpose of use
Bello is a product that monitors the size of a passed light signal by projecting the near-infrared light on the
abdomen and performs health care by measuring the body fat of the abdomen.
Alert
This device measures abdominal fat quantitatively by using noninvasive method using LED
Prior to using this product, you should fully understand this manual.
Misuse of the device may result in damage to the device or personal injury, but the company is not
liable for any damages.
Reason of use prohibition
Do not use Bello for users with the following symptoms:
* Children
* Open-up wound
* Sensitive skin
* If there is a metal stent in the area of use
* In case of bioabsorbable implants
* Those who mount implantable medical devices (those who mount medical devices that affect
electromagnetic waves, such as artificial pacemakers, implantable defibrillator, Implantable medical
electric stimulator, implantable electronic dysuria suppressor, etc.)
* In case there is a systemic/local skin disease that can affect the healing process of the wound
Precautions
* Do not look at LED light sources directly with the naked eye.
* Do not use in the place with children or areas prone to shock.
* Keep out of reach of children.
* Do not use with flammable substances.
If you notice potential safety issues or abnormalities during use, you should immediately stop using them
and inform Olive Healthcare Customer Service (CEO number 0000-000000).
Contact us
* Olive Healthcare Inc. / 505, 283, Gangnamdae-ro, Seocho-gu, Seoul, Republic of Korea.
Tel ) 000-000-0000
* US Agent : Jennifer Hadfield / Adress ----- / E-mail : ---------
Tel ) 000-000-0000
Customer service of Bello
Customer support center 000- 0000 homepage: www.olive-hc.com
Alert
Prior to using Bello system, all the users should fully understand the manual provided.

OH-UM_Bello(Rev.0) Bello USER MANUAL | 6 Olive Healthcare Inc.
Introduction
Labelling notation
The following symbols are indicated in the configuration and the supplies and package that are supplied
with system
Indication
Description
Indication
Description
Warning
Warning
Alert
Alert
Note
This electronic device
shall be disposed in a
special way.
This waste cell must be
disposed of in a special
way
Serial number
This indicates the (IEC
60417-5333) type BF
mounting part in the
protection regulations
against electrical shock
Manufacturer
Date of Manufacturing
Obtain the FCC
registration.
See the Manual
Temperature limit
- The minimum
temperature at the lower
left and the maximum at
the upper right.
Humidity limitation
- The minimum
humidity at the lower
left and the maximum
at the upper right.
Atmospheric pressure
limitation
- The minimum
Atmospheric pressure at
the lower left and the
maximum at the upper
right.
※We recommend to use after fully understanding the description of symbols and indication
displayed in thescreen.

OH-UM_Bello(Rev.0) Bello USER MANUAL | 7 Olive Healthcare Inc.
Introduction
User document
The Bello System User's Manual provides detailed information on components, how to use equipment,
troubleshooting, cleaning, and maintenance of system.
Bello provides documentation for the main unit and app.
The user manual provides the latest information on safety and use. Bello has the right to change the
contents of the User document at any time.
Before using system components, always obtain the latest user documents, fully understand before
use.
All images included in the Bello User document are sample images.
The hardware and information of the system you actually use might not be the same as that
shown in the documentation.

OH-UM_Bello(Rev.0) Bello USER MANUAL | 8 Olive Healthcare Inc.
About product
and parts
Preparation for use
How to use
Maintenance and storage
method of product
Troubleshooting
Overview of Warranty
1. About product and its parts
1.1. About product
Bello is a device that measures abdominal fat quantitatively by analyzing the bio-signals using multi-wave
LEDs and calculating the fat rate.
1.1.1. Overview of Bello
1.1.1.1 Electrical specification
a) Type of protection against electric shock: Class II
b) Degree of protection against electric shock: Type BF applied part
c) Degree of protection against harmful ingress of water or particulate matter: IP22
d) Rated voltage and power consumption:
• 3.7 Vdc, 1050 mAh (for battery operation)
• 0.52 A, 5 Vdc (for charging)
e) Technical specifications
• Battery: 3.7V, 1050mA
f) Safety device
If anomaly occurs during use, the instrument will not operate. Detected anomalies include following:
• Power switch: If the power switch is turned off in an emergency, the instrument will not operate.
• Measurements are not made when the abdomen and equipment are exposed to normal light without
contact.
• The device will not operate during charging.
g) Firmware
• Version : 1.0.x
h) Bluetooth
• Version: 4.1
• Profile: GATT
• Frequency: 400 MHz to 2483.5 MHz
• Bandwidth: 83.5 MHz
• Power class: 2 (+4 dBm)
• Modulation: GFSK
• Support range: 10m
i) LED specification
• LED 1: 688/795/830/860 nm wavelength
• LED 2: 808/915/976/1064 nm wavelength
1.1.1.2. Mechanical specification
a) Dimension [W×D×H]: 80.4 x 91.4x 23mm
b) Weight: 114 g
1.1.1.3. Application specification
a) Applicable smartphone and OS version: IOS x.x or more
b) The Application is continually updated with the latest intelligence.

OH-UM_Bello(Rev.0) Bello USER MANUAL | 9 Olive Healthcare Inc.
About product
and parts
Preparation for use
How to use
Maintenance and storage
method of product
Troubleshooting
Overview of Warranty
1.2 Composition and function of the product
1.2.1 Composition of product
Bello consists of:
이미지 삽입
NO
Composition
Quantity
Remark
A
Main unit
1EA
B
USB Cable
1EA
C
Manual
1EA

OH-UM_Bello(Rev.0) Bello USER MANUAL | 10 Olive Healthcare Inc.
About product
and parts
Preparation for use
How to use
Maintenance and storage
method of product
Troubleshooting
Overview of Warranty
1.2.2Nameand function of components
1.2.2.1 Main unit
NO
NAME
CSNTENT
A
Display LED
LED that displays data measured in the device
B
Measurement LED
LED that flashes when the light sources are operated
during measurement
C
Charger LED
LED that is on during charge
D
ON/OFF & Measurement
Button
Button that ON/OFF the power of device for operation
E
LED Source (Applied part)
Multi wave length light source that measures fat in the
abdomen
F
PD Sensor (Applied part)
Sensor that receives the multi wave length light signal
delivered to the abdomen
G
Charging PORT
Port for charging of built-in battery

OH-UM_Bello(Rev.0) Bello USER MANUAL | 11 Olive Healthcare Inc.
About product
and parts
Preparation for use
How to use
Maintenance and storage
method of product
Troubleshooting
Overview of Warranty
2. Preparation for use
2.1. Matters to be checked before use
2.1.1 When using the product for the first time, please check the following
The user has full control device.
Be sure to fully understand and use the manual before using it.
It is recommended that you carefully read the instructions provided before using them and check the area
of use to use them.
Download the Bello app from your smartphone and proceed with the device and Bluetooth activation
before using it
iOS 10.3 version or higher
When using the product for the first time, please charge it completely before using it.
Do not connect to the main unit if the cable is damaged. It might cause product failure.
For the adaptor, please use the following specifications. (Purchases separately)
-
IEC/EN 60950-1 Certified Products
-
Class II products
-
Rated input: 100-240 V
-
Rated output: 5 Vdc, 2 A or more
-
Micro 5 PIN USB cable length: 1 m
If possible, please avoid direct exposure to direct sunlight.
Be sure that the cables are connected correctly when charging, and be careful not to shock the product
by connecting it with a wet hand.
Alert
Be cautious to minimize the shock to the product in use.

OH-UM_Bello(Rev.0) Bello USER MANUAL | 12 Olive Healthcare Inc.
About product
and parts
Preparation for use
How to use
Maintenance and storage
method of product
Troubleshooting
Overview of Warranty
3. How to use
3.1. How to use product
3.1.1Preparation before using system
•Verify that you have all the quantities per package.
•Check the battery remaining LED and charge it sufficiently before using.
•It is recommended that you carefully read the instructions provided before use, check the area of use,
and do not use it in any areas other than the suggested area.
•To be more accurate, please fully understand the Quick Guide provided other than the manual and the
tutorial provided by the app.
3.1.2Turn on and off the device
•Press the button on the top of the device for more than 2 seconds to turn it on. When the device is
powered on, it indicates "Hi".
(If the battery is not charged, the power may not be turned on
Connect to the charge PORT before use.)
•Press the button for more than 3 seconds to turn off the device.
3.1.33HowtouseapplicationssuchasBelloBLE Pairing, Measurement etc.
•Execute Bello app from Mobile and enter and confirm user information and click the "Next" button to
move to Measurement Preparation step.
•Tap the "Connect" button in the shape of the person's head shown in the app in order to connect the
Bello Device to the app prior to Measurement.

OH-UM_Bello(Rev.0) Bello USER MANUAL | 13 Olive Healthcare Inc.
About product
and parts
Preparation for use
How to use
Maintenance and storage
method of product
Troubleshooting
Overview of Warranty
•If the pop-up window for the selection of Bello Device, check Bello Device ID and select the device
to be connected.
•The first time you connect to the selected Bello Device, the pairing process starts, and you can enter
the 6 digits that have been indicated to the Bello Device in the Bello app pop-up window and tap the
"Pair connection" button. (For devices that have already been connected, they are connected directly
without the pairing process)
•When the device is connected, the human-shaped image is lit in orange, the text "SCAN UPPER
FIRST" is displayed at the bottom of the screen, and the message "READY" is checked on the LED
Display of the Bello Device.
•When the measurement is ready, attach the instrument to the upper abdomen and click the
Measurement button at the top of the instrument to make a measurement. (If you click the
Measurement button, the measurement will proceed with a beep sound.)

OH-UM_Bello(Rev.0) Bello USER MANUAL | 14 Olive Healthcare Inc.
About product
and parts
Preparation for use
How to use
Maintenance and storage
method of product
Troubleshooting
Overview of Warranty
•Measurements take approximately 3 to 5 seconds and during measurements, the bottom and the first
left app screens are shown to prevent the device from falling off the measurement area.
•When the first measurement is completed, the measurement value will be displayed on the Bello
device, and the "SCAN LOWER SECOND" text will be displayed at the bottom of the app screen as
the check mark is inserted in the upper part of the human-shaped image.
•When the upper part measurement is completed normally, attach the instrument to the lower abdomen
and press the Measurement button to perform the measurement.
•When the upper-lower measurement is completed, the "CALCURATING" pop-up and the "SCAN
COMPLETE" text display at the bottom of the app, showing the result screen approximately 3 to 5
seconds later.

OH-UM_Bello(Rev.0) Bello USER MANUAL | 15 Olive Healthcare Inc.
About product
and parts
Preparation for use
How to use
Maintenance and storage
method of product
Troubleshooting
Overview of Warranty
Battery remaining LED
Status
Role
Battery status
LED
During connecting charging
cable
1. Fully charged
Always on
2. during charging
2 seconds on / 2 seconds off
If there is no charging cable
1. Low Voltage Warning (under 3.5V)
0.5 seconds on / 0.5 seconds off
2. Forced sleep (under 3.3V)
50msec on / 50msec off
LED error message
Status
Role
FAIL
1. When Bello Device fails during Measurement
2. If you do not receive the proper measurement result from the
server after completing the measurement,

OH-UM_Bello(Rev.0) Bello USER MANUAL | 16 Olive Healthcare Inc.
About product
and parts
Preparation for use
How to use
Maintenance and storage
method of product
Troubleshooting
Overview of Warranty
3.2. Precautions for use
•Do not use this product in your eyes or eyelids and do not aim directly at your eyes.
•May cause eye damage when irradiated on the eyeball.
•Since this product is an electronic medical device, electromagnetic interference may affect the
performance of the product. Keep it as far away from other electronic products that may cause
electromagnetic interference while the product is in operation.
•Be cautious any adverse effect accidents caused by the negligence in use.
•Check the health of the intended person.
•Keep out of reach of children.
•Do not burn and discard the battery. It may cause the battery to explode.
•The battery is not replaceable component. Do not disassemble or damage the battery. The released
electrolyte is harmful to the skin, eyes, etc. and may contain toxins.
•This device may not be able to connect with App. in a wireless environment with interference. Use it
in a place where there is no significant interference in surrounding radio waves.
•Please follow "Operations by Fault Symptom" if connection is not smooth
3.2.1Generalprecautions
•If any noticeable damage is found to this product, please stop using it.
•Do not attempt to open or repair the device arbitrarily
3.2.2 Precautionsbeforeusingdevice
•Avoid use by pregnant women or children (check required)
•Avoid using progressive dermatitis patients.
•Do not use the device while charging the device and mobile app.
Alert
In case of failure, check any abnormalities of power supply, charger, etc. Do not touch the device
arbitrarily. After proper indication, request the repair to the expert of manufacturer • importer or
repairer.

OH-UM_Bello(Rev.0) Bello USER MANUAL | 17 Olive Healthcare Inc.
About product
and parts
Preparation for use
How to use
Maintenance and storage
method of product
Troubleshooting
Overview of Warranty
4. Product maintenance and storage method
4.1. Precautions for management
•Store the product in a dry place.
•Avoid environments where direct sunlight can cause higher temperatures.
•Be cautious to prevent damage when main unit falls on the floor.
•Move the product into a pouch when it is moved to another location or area
•Wipe the measuring section with a dry cloth before use.
4.2. Precautions for storage
•Avoid the place with visible water in the naked eye for storage.
•Be cautious adverse effects such as air pressure, temperature, humidity, ventilation, daylight, and the air
containing dust and salt.
•Store the device by considering incline, vibration, or impact.
•Do not store in the place where chemicals are stored, or the places where gas is generated.
•Keep it in consideration of hygiene.
Use condition
Condition of transport and storage
Temperature
5℃~ 40℃(℉~ 90℉)
-20℃~ 60℃(-68℉~ 140℉)
Relative
humidity
15% ~ 90%
Atmospheric
pressure
70kPa ~ 106kPa (Altitude: Max. 3000 m)

OH-UM_Bello(Rev.0) Bello USER MANUAL | 18 Olive Healthcare Inc.
About product
and parts
Preparation for use
How to use
Maintenance and storage
method of product
Troubleshooting
Overview of Warranty
5. Troubleshooting
5.1. Failure specific actions
Name
Role
If the power is not ON
• With the power off, press the power switch for more than 10 seconds.
• Check if it is charged.
• If main unit does not work after checking the above, contact your dealer or
A/S center.
In case of measurement
failure
• Hardware
• Press the power switch for more than 3 seconds and check if the power is
turned off.
• Again, press the power switch for more than 2 seconds and make sure it is
turned on.
• When the display LED is "READY" and the power switch is pressed quickly,
check if the measurement LED is lit in yellow.
• If a 'FAIL' message occurs after measurement
- Check that the network status of the mobile phone is properly connected.
- Re-measurement by keeping the Bello Device close to the human body
• If this does not work after checking the above, contact your dealer or
customer center.
In case of charging failure
• When connecting the charger to a device other than the Bello, make sure that
it is properly charged.
• Check if the charging LED is ON when the charger is connected to the Bello.
• If this does not work after checking the above, contact your dealer or
customer center.
If Display LED is not
operated
•Contact your agent or customer center if the display LED is not operated
properly while the power on.
If you can’t hear buzzer
sound
• Conduct Measurement in a quiet place
• Contact your dealer or customer center if:
• Measurement is successful, but no buzz is heard
• Measurement failed and no buzz is heard
If Bello Device and Mobile
App are not connected,
• Press the Measurement button in the 'WAIT' or 'READY' state for 10
seconds.
• Check the 'RESET' message on the display LED.
• Delete the phone's Bluetooth device information.
• Turn on the Bello Device and try to reconnect it.
• If this does not work after checking the above, contact your dealer or
customer center.

OH-UM_Bello(Rev.0) Bello USER MANUAL | 19 Olive Healthcare Inc.
About product
and parts
Preparation for use
How to use
Maintenance and storage
method of product
Troubleshooting
Overview of Warranty
6. Overview of Warranty
6.1. Overview
The description of the Free Warranty when the product is operating normally and the
description of the warranty exclusions within the Free Warranty Period
6.2. Free warranty
•In case of normal use and post-service, Olive Healthcare provides the warranty free of charge
for one year from the date of purchase.
•In principle, if a repair request has been made for Free Warranty, it shall be handled promptly
and repair or replaceable at the headquarters of Olive Healthcare Inc.
or the location where the product is installed, depending on the repair parts or processing period
of the product. (Check the availability of repair)
•When requesting a Free Warranty, the user should provide the olive healthcare with materials or
video photos to identify problems with the product.
•In all cases, the responsibility and rights to determine the content and cause of product damage
are at Olive Health Care Co., Ltd. and that judgment cannot be changed to final.
•In order for the Free Warranty to be maintained, the maintenance and modification of the product
must be made by service personnel formally designated by Olive Health Care Co., Ltd. If the
product is not used in accordance with the instructions of this manual, it might be excluded from
free warranty so fully understand the manual.
•
In all cases, the responsibility and rights to determine the content and cause of product damage are
at Olive Health Care Co., Ltd. and that judgment cannot be changed to final.

OH-UM_Bello(Rev.0) Bello USER MANUAL | 20 Olive Healthcare Inc.
About product
and parts
Preparation for use
How to use
Maintenance and storage
method of product
Troubleshooting
Overview of Warranty
6.3. Warranty exclusions during free warranty period
Failure to comply with the product operating procedures and safety precautions
provided in this manual will result in no free-warranty repair and be cautious the
following items more when using the product.
.
•Warranty is excluded when the user uses, changes, or disassembles the product other than its
intended purpose.
•Any damage or loss by the user's negligence will be excluded from the warranty.
- Damage caused by main unit disassembly or impact
•Any disassembly or repair of personal equipment other than those certified by Olive Health Care
Co., Ltd. is excluded from warranty.
•
The genuine product supplied by the manufacturer shall be used. If it is used with any alterations or
modifications, free or paid repair service might be provided, and we are not responsible for any
legal problems caused by any alterations or modifications.
This manual suits for next models
1
Table of contents
Other Olive Healthcare Personal Care Product manuals
Popular Personal Care Product manuals by other brands

Philips
Philips Wisp Caregiver guide

Orliman
Orliman BE-245 Use and maintenance instructions

KETCHAM
KETCHAM AURORA Series installation guide

Wanasleep
Wanasleep Wanabesafe WHITE 2020 Manual instructions

aidapt
aidapt VM924 Usage and maintenance instructions

aidapt
aidapt VM992AA Usage and maintenance instructions