  9. olympia electronics BS-506/ALKALINE User manual

olympia electronics BS-506/ALKALINE User manual

Other olympia electronics Smoke Alarm manuals

olympia electronics BS-655 User manual

olympia electronics

olympia electronics BS-655 User manual

olympia electronics BSR-6155/MAR User manual

olympia electronics

olympia electronics BSR-6155/MAR User manual

olympia electronics BSR-6055/A/MAR User manual

olympia electronics

olympia electronics BSR-6055/A/MAR User manual

olympia electronics BSR-6157 User manual

olympia electronics

olympia electronics BSR-6157 User manual

olympia electronics BS- 655/A User manual

olympia electronics

olympia electronics BS- 655/A User manual

olympia electronics BS-116 User manual

olympia electronics

olympia electronics BS-116 User manual

olympia electronics BSR-6155 User manual

olympia electronics

olympia electronics BSR-6155 User manual

olympia electronics BS-655 User manual

olympia electronics

olympia electronics BS-655 User manual

olympia electronics BS-655/A User manual

olympia electronics

olympia electronics BS-655/A User manual

olympia electronics BSR-6055 User manual

olympia electronics

olympia electronics BSR-6055 User manual

olympia electronics BSR-6055/A Operator's manual

olympia electronics

olympia electronics BSR-6055/A Operator's manual

olympia electronics BS-506/LITHIUM User manual

olympia electronics

olympia electronics BS-506/LITHIUM User manual

olympia electronics BS-657 User manual

olympia electronics

olympia electronics BS-657 User manual

olympia electronics BS- 657/A User manual

olympia electronics

olympia electronics BS- 657/A User manual

olympia electronics BSR-6057/A/MAR User manual

olympia electronics

olympia electronics BSR-6057/A/MAR User manual

Popular Smoke Alarm manuals by other brands

x-sense SD19-W user manual

x-sense

x-sense SD19-W user manual

FireAngel Thermoptek ST-622 user manual

FireAngel

FireAngel Thermoptek ST-622 user manual

teko Astra-42A user guide

teko

teko Astra-42A user guide

Siemens PE-11C installation instructions

Siemens

Siemens PE-11C installation instructions

System Sensor DH500ACDC Installation and maintenance instructions

System Sensor

System Sensor DH500ACDC Installation and maintenance instructions

Resolution Products RE612 CryptiX quick start guide

Resolution Products

Resolution Products RE612 CryptiX quick start guide

First Alert PC900V user manual

First Alert

First Alert PC900V user manual

Eminent EM6590 E-Domotica user manual

Eminent

Eminent EM6590 E-Domotica user manual

Ei Electronics Ei Ei168RC user manual

Ei Electronics

Ei Electronics Ei Ei168RC user manual

Carrier Kidde Quell Q301 user manual

Carrier

Carrier Kidde Quell Q301 user manual

VESDA VLF-500 Product guide

VESDA

VESDA VLF-500 Product guide

ELRO FS8110 instruction manual

ELRO

ELRO FS8110 instruction manual

Heiman SMOKI NS-626PHS user manual

Heiman

Heiman SMOKI NS-626PHS user manual

Family Gard FG225 user manual

Family Gard

Family Gard FG225 user manual

Regin SDD-S65 instruction manual

Regin

Regin SDD-S65 instruction manual

Aparton ASD-10 Instructions for use

Aparton

Aparton ASD-10 Instructions for use

Greystone DSD120 Installation and maintenance instructions

Greystone

Greystone DSD120 Installation and maintenance instructions

LST ÜMS-55000-841 Specification sheet

LST

LST ÜMS-55000-841 Specification sheet

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

BS-506/ALKALINE
Olympia Electronics guarantees the quality, condition and operation of the
goods. The period of warranty is specified in the official catalogue of Olympia
Electronics and also in the technical leaflet, which accompanies each product.
This warranty ceases to exist if the buyer does not follow the technical
instructions included in official documents given by Olympia Electronics or if the
buyer modifies the goods provided or has any repairs or re-setting done by a third
party, unless Olympia Electronics has fully agreed to them in writing. Products
that have been damaged can be returned to the premises of our company for
repair or replacement, as long as the warranty period is valid.
Olympia Electronics reserves the right to repair or to replace the returned goods
and to or not charge the buyer depending on the reason of defection. Olympia
Electronics reserves the right to charge or not the buyer the transportation cost.
Thank you for your trust in our products
Olympia Electronics - European manufacturer
921506000_09_005
Warranty
4 5
European
manufacturers
72nd km. O.N.R. Thessaloniki-Katerini
P.C. 60300 P.O. Box 06 Εginio Pierias Greece
www.olympia-electronics.com
info@olympia-electronics.gr
Signaling Overview
1 Red per 344 sec None Device
functioning properly
1 Red per sec Alarm pattern Device under test
1 Red per sec Alarm Pattern Smoke detected
1 Red per 10 sec None 9 min
decreased sensitivity
3 Yellow per 43 sec None Exited an
alarm mode
None Replace batteries
None 3 short signals
per 43 sec
Replace the
smoke detector
1 short signal
per 43 sec
ALARM
TEST
HUSH
ALARM MEMORY
LOW BATTERY
FAULT WARNING
NORMAL
1. Remove smoke alarm from mounting plate following Step 1 of the
installation instructions.
4. Place the smoke alarm on the Mounting plate and secure it by turning it
clockwise.
3. Replace the old batteries by a new pair. Use recommended batteries for
more reliable operation.
2. Clean the device as described in maintenance paragraph.
5. Test the correct operation of your smoke alarm as described in Device Test
paragraph. If no sound is generated, the smoke alarm must be replaced
immediately!
The WEEE symbol means that this product and batteries must be disposed
separately from other household waste. When they reach their end of
life, take them to a designated waste collection point in your area to
guarantee a safe disposal or recycling. Protect the environment, human
health and natural resources!
False alarm is often caused by dust or steam.
After a batteries replacement, the device performs an auto-adjusting process
in 8 hours period to establish its operation. If false alarm happens within this
period, it is important to clean the smoke alarm as described in maintenance
paragraph.
Battery Replacement
Recycling and Desposal
Troubleshooting
921506000_09_005
Visible indication
(flashes)
Operating Mode Acoustic Signal Comment
BS-506/ALKALINE
7 years
Technical Characteristics
0.110 dB/m
Optical and Acoustic > 85dB (A) at 3 m
Yes
Yes
Yes
Ceiling
No
Optical
IP20
EN14604-2005
o
0 to 45 C
Up to 93%
ABS/PC, PC
Ø130 x 43 mm
185gr.
3 years (1 year for the battery)
SMOKE CONCENTRATION SENSITIVITY
INDICATORS
ALARM SILENCE FACILITY
LOW BATTERY WARNING
LOW BATTERY SILENCE FACILITY
MOUNTING LOCATION
INTERCONNECTABLE
DETECTION METHOD
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
DEGREES OF COVER PROTECTION
RELATIVE HUMIDITY
CONSTRUCTION MATERIAL
EXTERNAL DIMENSION
WEIGHT
GUARANTEE
POWER SUPPLY
BATTERY LIFE
Replaceable batteries: 2x Alkaline AA (LR6)
IP20 7 years Optical 85dB
EN14604
2005
Battery
Life
BATTERY OPERATED
SMOKE DETECTOR
BS-506/ALKALINE
Battery Operated
Smoke Detector 1922
21
EN 14604:2005
DoP: 921506000_59_001
EGINIO
PIERIAS
60300
GREECE
The BS-506 is a battery operated smoke detector with an optical sensor for
installation in residential buildings, apartments and rooms. Smoke alarms are
designed to provide an early warning of fire events giving enough time for
people to evacuate the building/room. Always consult local regulations for
smoke alarms.
ŸDo not paint or cover the smoke alarm.
ŸConsult the manufacturer's advice if the device doesn't work properly.
If the battery's level is low, the horn will sound as a short pulse every 43
seconds which continues until the batteries are replaced. If a low battery
condition exists, a Low Battery Hush mode can be selected by pressing the
TEST button, the Red LED will turn on to indicate the low battery condition.
After the TEST button is released, the unit enters Low Battery Hush mode and
the device is silenced for 8 hours. At the end of the 8 hours, the audible
indication will resume. The activation of the TEST button will also initiate the 9
minutes Hush mode.
ŸTo prevent injury, the device must be securely attached to the ceiling in
accordance with the installation instructions.
ŸDo not install the detector close to ventilation points.
CAUTION!!
ŸDo not install the detector in leisure accommodation vehicles
ŸDo not install the detector in direct sunlight. Keep at least 0.5m from light
sources.
A Device Test is performed when the TEST button is pressed for more than 1
second. If the device works properly it will produce a loud alarm sound. When
the TEST button is released, the alarm sound will stop and the device enters
the Hush mode. After a time of 9 minutes returns to normal (stand by)
operation.
When the device is in Alarm condition, every Device Test will initiate the Hush
mode. When Hush mode is started, the unit immediately resets out of Alarm
condition and the horn is silenced. The Hush mode duration is 9 minutes and
the Red LED flashes faster, after this period expires, the unit goes back to its
normal operation. During Hush mode, the device's sensitivity is reduced and a
higher Smoke concentration is needed, to place the unit again into an Alarm
condition. Also, Hush mode can be canceled from the user by performing a
new Device Test.
HUSH
LOW BATTERY MODE
ŸDue to the loudness of the alarm, make sure that you always stand at arm's
length distance from the unit when you are testing.
DEVICE TEST
ŸBatteries should be protected from excessive heat, such as direct light
beams or fire.
The Alarm Memory allows easy identification of any unit that had previously
been in Alarm. When a detector exits an Alarm condition, the Yellow LED
flashes three times and this pattern repeats every 43 seconds. This visual
indication will stop after a period of 24 hours. The user will still be able to
identify a unit that had previously been in Alarm, by pressing the TEST button,
the horn will sound in short pulses and the Alarm memory resets. The initial 24
hour visual indication is not displayed when a low battery condition exists.
ALARM MEMORY
When the smoke alarm is not functioning properly, it will turn into the Fault
warning mode and produces three short acoustic signals every 43 seconds. Try
cleaning the smoke alarm (see paragraph maintenance) otherwise replace it!
FAULT WARNING
—Test the smoke alarm weekly for correct operation using the Device Test
facility. If the smoke alarm functions correctly, it will generate a loud beep
otherwise must be replaced immediately!
—Clean the smoke alarm once per month to remove dirt, dust or debris.
—Use a vacuum cleaner with a soft brush and vacuum all sides and covers of
the smoke alarm. Do not remove the top cover of the smoke alarm to clean
it inside.
—In accordance with EN14604 standard, is recommended to replace the
device after 10 years of operation.
—Do not attempt to repair this smoke alarm. If the smoke alarm shows a
damage it must be replaced!
1
2
1
1
Smoke detector
AA Batteries (installed)
Mounting accessories
Manual
Package Contents
Maintenance
General
Installation instructions
1 2 3
1
5
6
2
3
6 mm
If no sound is generated, the smoke alarm is not functioning properly and
should not be used!
NOTE!!!
921506000_09_005 921506000_09_005 921506000_09_005
B
C
A
B
C
A
4