BS- 657/A
The user have to read carefully the following instructions, in order to be properly informed and
keep them for future use.
INSTALLATION
They are composed by two parts. A plastic base which is placed on the ceiling and the main
body of the detector which fits on the plastic base with a simple rotation to the right. The
o
detectors have a 360 visible led and a remote led driver which are light up constantly in case
of detection of fire, till cancelled from the panel. They are turned off only when a reset
command is given from the panel. The indicator led blinks every 6 sec indicating the normal
function.
GENERAL
The detectors should be placed in the ceiling in visible points without side obstacles, away
from places that are barely ventilated or with strong air currents and water vapor. Each
2
detector covers an area of 50 m while the distance between two detectors should not be
more than 15m. Also, they must be placed at least 50 cm away from fluorescent lamps. Cable
diameter should be from 0.5 to 2.5mm.
The BS-657/A is a conventional smoke detector which integrates functions of optical smoke
and heat detection. It can detect smoke and heat. The detector transitions to alarm state when
o
the concentration of smoke reaches 0.107dB/m or when the temperature reaches 57 C.
o
Also, the detector transitions to alarm state when the temperature rises suddenly by 32 C
regardless of the initial temperature at the beginning of the sudden rise event.
90μΑ
17-30V DC
IP42
EN 54-5,EN 54-7
12mA (with activated onboard LED)
0.107 dB/m
57oC
ABS/PC
158 gr.
103 (d) x 55 (h) mm
1mΑ for 2 sec
A1R
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATING TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIALS
EXTERNAL DIMENSIONS
TYPICAL WEIGHT
GUARANTEE
START UP POWER CONSUMPTION
OPERATION VOLTAGE
Olympia Electronics - European manufacturer
Thank you for your trust in our products
CLASS
INDICATORS
OUTPUT
TEMPERATURE SENSITIVITY
SMOKE CONCENTRATION SENSITIVITY
STANDBY CONSUMPTION
ALARM CONSUMPTION
TECHNICAL CHARACTERISTICS
Up to 95%
ο
-40 to 70 C
To panel / to external LED driver (BS-572)
Alarm LED
2 years
Optical smoke and rate-of-rise heat detector
Warranty
Warranty
P.C. 60300 P.O. Box 06 Εginio Pierias Greece
72nd km. O.N.R. Thessaloniki-Katerini
www.olympia-electronics.gr
Olympia Electronics guarantees the quality, condition and operation of the goods. The period
of warranty is specified in the official catalogue of Olympia Electronics and also in the
technical leaflet, which accompanies each product. This warranty ceases to exist if the buyer
does not follow the technical instructions included in official documents given by Olympia
Electronics or if the buyer modifies the goods provided or has any repairs or re-setting done
by a third party, unless Olympia Electronics has fully agreed to them in writing. Products that
have been damaged can be returned to the premises of our company for repair or
replacement, as long as the warranty period is valid.
[email protected]
HEAD OFFICE
Olympia Electronics reserves the right to repair or to replace the returned goods and to or not
charge the buyer depending on the reason of defection. Olympia Electronics reserves the
right to charge or not the buyer the transportation cost.
Page 4 from 4 921657002_09_008
1293
21
EN 54-5:2017,
EN 54-7:2018
DoP: 921657002_59_001
EGINIO
PIERIAS
60300
GREECE
BS-657/A
Optical smoke
and rate-of-rise heat detector
21
1293
Additional features of the device :
- Integration of dynamic algorithms for noise and false alarm rejection.
- Compensation of smoke measurements based on ambient temperature which
ensures high precision measurements even under extreme environmental
conditions.
- 360
ooptically visible LED.
- Dust compensation and automatic indication when cleaning is required. Stable
level of detection regardless of detector’s working hours.
In every device there is a double sticker with the UID (Unique Identifier) number. This number is
unique for each device.
- Automatic fault diagnosis.
UID:
MAINTENANCE & FUNCTIONAL TESTING
The detector has fault diagnosis and dust compensation functions, which automatically
informs you through the onboard LED when replacement or cleaning actions are required.
The indication LED blinks every 7 seconds. In normal operation it blinks 1 time, if cleaning
action is required it blinks 2 times and if there is a failure it blinks 3 times. These functions
combined with periodic manual testing ensure maximum security level. The manual testing
procedure is carried out by spraying a small amount of smoke into the detector with an A-752
spray or a counterpart product. It is suggested to carry out a test every 6 months or after a
change in the position of the sensor. A key element of its proper function is the air to be able to
freely circulate inside it. So be careful not to block the openings of the outer cover. Before the
manual testing it is suggested to enable the special “walk in test” mode from the panel.
Also, during site works place the plastic cover to the detector as shown in the picture below to
protect the device from dust.
CAUTION !!
After installation the device must not be covered with dust or be painted or anything else
happen that will block the smoke to get to the sensor. Special attention must be given during
the installation and the use of the device, since the user assumes full responsibility for proper
operation afterwards.
Page 2 from 4 921657002_09_008
4. - R : It is connected with BS-572.
1. Remove the detector from its base rotating to the left till the side marks are aligned.
3. Connect the power cables (minding the correct polarity) according to the requirements of
the installation (Figure 1, 2).
5. : Connected to the cable’s shield (when shield is used).
3. - OUT : It is connected to the next detector (- IN) or if it is the last one to the terminal
resistor.
CONNECTION
4. Place the detector carefully so that the side marks are on the same position and rotate the
detector clockwise until it locks. Power the device and after 3-5 seconds it is ready for
operation.
2. - IN : It is connected to the zone of the panel or to the (- OUT) contact of the
previous detector.
1. + IN/OUT : It is connected to the zone of the panel or to the (+ IN/OUT)
contact of the previous detector.
2. Fasten the base with the supplied mounting materials (point 5).
Installation process
Installation process
-R
U
T
/O
N
I
+
N
- I
T
U
- O
-R
U
T
/O
N
I
+
N
- I
T
U
- O
If the power of the detectors is turned off, wait for 3-5 seconds before you turn the power on
again.
Connection
Termin ating
resistor
Figure 2
Fr om zone
of t he panel
Mounting base
Figure 1
2
Connection
with exterrnal
LED
Page 3 from 4 921657002_09_008
Side marks
e
n
i
t
n
s
g
a
f
d
t
e
n
t
a
e
c
m
h
1
Indicating
LED
55
R
+
-R
U
T
/O
N
I
+
N
- I
T
U
- O

Other olympia electronics Smoke Alarm manuals

olympia electronics BSR-6157 User manual

olympia electronics

olympia electronics BSR-6157 User manual

olympia electronics BSR-6055 User manual

olympia electronics

olympia electronics BSR-6055 User manual

olympia electronics BS- 655/A User manual

olympia electronics

olympia electronics BS- 655/A User manual

olympia electronics BS-506/ALKALINE User manual

olympia electronics

olympia electronics BS-506/ALKALINE User manual

olympia electronics BSR-6055/A/MAR User manual

olympia electronics

olympia electronics BSR-6055/A/MAR User manual

olympia electronics BS-655/A User manual

olympia electronics

olympia electronics BS-655/A User manual

olympia electronics BS-506/LITHIUM User manual

olympia electronics

olympia electronics BS-506/LITHIUM User manual

olympia electronics BS-657 User manual

olympia electronics

olympia electronics BS-657 User manual

olympia electronics BSR-6057/A/MAR User manual

olympia electronics

olympia electronics BSR-6057/A/MAR User manual

olympia electronics BS-655 User manual

olympia electronics

olympia electronics BS-655 User manual

olympia electronics BS-655 User manual

olympia electronics

olympia electronics BS-655 User manual

olympia electronics BSR-6155 User manual

olympia electronics

olympia electronics BSR-6155 User manual

olympia electronics BSR-6155/MAR User manual

olympia electronics

olympia electronics BSR-6155/MAR User manual

olympia electronics BSR-6055/A Operator's manual

olympia electronics

olympia electronics BSR-6055/A Operator's manual

olympia electronics BS-116 User manual

olympia electronics

olympia electronics BS-116 User manual

Popular Smoke Alarm manuals by other brands

Carrier Kidde Quell C3010K-CO user manual

Carrier

Carrier Kidde Quell C3010K-CO user manual

Kidde V-PS Installation sheet

Kidde

Kidde V-PS Installation sheet

Channel Safety Systems Rapidfire user manual

Channel Safety Systems

Channel Safety Systems Rapidfire user manual

Honeywell Notifier VESDA-E VEA Series Product guide

Honeywell

Honeywell Notifier VESDA-E VEA Series Product guide

Panasonic 2318 Specification sheet

Panasonic

Panasonic 2318 Specification sheet

techem smoke detector 2 operating instructions

techem

techem smoke detector 2 operating instructions

Ei Electronics Ei3100RF? Ei3500RF Instruction leaflet

Ei Electronics

Ei Electronics Ei3100RF? Ei3500RF Instruction leaflet

EVERSPRING SF804 user manual

EVERSPRING

EVERSPRING SF804 user manual

Universal Security Instruments Sensing Plus AMI1061S instructions

Universal Security Instruments

Universal Security Instruments Sensing Plus AMI1061S instructions

AROHA SM11R4 Quick reference guide

AROHA

AROHA SM11R4 Quick reference guide

Risco WL T33S installation instructions

Risco

Risco WL T33S installation instructions

minirookmelder.be MR5120 installation instructions

minirookmelder.be

minirookmelder.be MR5120 installation instructions

Nexa EL1313/KD-101LC user manual

Nexa

Nexa EL1313/KD-101LC user manual

AirSense Stratos Micra 10 Installer's handbook

AirSense

AirSense Stratos Micra 10 Installer's handbook

Kidde P4010ACS-W user guide

Kidde

Kidde P4010ACS-W user guide

Cavius 2208 installation guide

Cavius

Cavius 2208 installation guide

First Alert SLED177 user manual

First Alert

First Alert SLED177 user manual

U-Line H-9472 quick start guide

U-Line

U-Line H-9472 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.