Omron VIVA User manual

Body Composition Monitor
VIVA (HBF-222T-EBK)
,QVWUXFWLRQ0DQXDO
*HEUDXFKVDQZHLVXQJ
0RGHG¶HPSORL
0DQXDOGHLQVWUXFFLRQHV
0DQXDOHGLLVWUX]LRQL
*HEUXLNVDDQZLM]LQJ
ɊɍɄɈȼɈȾɋɌȼɈɉɈɗɄɋɉɅɍȺɌȺɐɂɂ
.XOODQÕP.ÕODYX]X
Thank you for purchasing the OMRON Body Composition Monitor.
Before using this unit, please be sure to read this Instruction Manual carefully to
understand the safe and proper use.
Please store this Instruction Manual carefully for future reference.
IM-HBF-222T-E-04-01/2018
3135909-5D
EN
DE
FR
ES
IT
NL
RU
TR
AR

1
VIVA
Body Composition Monitor
,QWHQGHG8VH
Thank you for purchasing this OMRON Body Composition Monitor. This unit is intended for measuring
and displaying the following body composition parameters.
- Body Weight - Body Fat (in %)
- Visceral Fat (up to 30 levels) - Skeletal Muscle (in %)
- Resting Metabolism (in kcal) - BMI (Body Mass Index)
This unit is intended to be operated by adults who can understand this instruction manual. It is not for
professional use in hospitals or other medical facilities, it is intended for home use only.
Please read this instruction manual carefully before use and for further information on the
individual functions.
&RQWHQWV
%HIRUHXVLQJWKHXQLW............................................................................................ 2
Notes on Safety....................................................................................................................2
1. Know Your Unit ..............................................................................................................4
2. Insert and Replace the Batteries....................................................................................5
3. Pair the Unit with Your Smart Device .............................................................................6
4.
Set the Measurement Unit, Date and Time .......................................................................... 7
5. Register the Personal Data............................................................................................8
2SHUDWLQJLQVWUXFWLRQV......................................................................................... 9
6. How to Take a Measurement Accurately........................................................................9
6.1 Correct postures during the measurement ..............................................................9
6.2 About the “0 kg correction” (Caution for storing) ....................................................10
6.3 How to implement the “0 kg correction” .................................................................10
7. Take a Measurement ...................................................................................................10
8VHWKH0HPRU\)XQFWLRQ.................................................................................. 12
8. View the Measurement Results on Your Smart Device ...............................................12
:KHQQHFHVVDU\ ................................................................................................. 13
9. Select Your Personal Number and Take a Measurement ............................................13
10. Guest Mode (Unrecorded Mode) .................................................................................14
11. Measure Weight Only ..................................................................................................15
12. Change or Delete Your Personal Data.........................................................................16
13.
Delete the Communication Setting....................................................................................... 17
14.
Maintenance and Storage................................................................................................17
15.
Troubleshooting .................................................................................................................. 18
16. Technical Data .............................................................................................................21
,QIRUPDWLRQRQERG\FRPSRVLWLRQ .................................................................... 24
17. Information on Body Composition................................................................................24
18. Measurement Results Interpretation Diagrams ..........................................................26

2
EN
Before using the unit
1RWHVRQ6DIHW\
6\PEROVDQGGH¿QLWLRQVDUHDVIROORZV
'DQJHU Improper use may cause danger resulting in death or serious injury.
:DUQLQJ Improper use may result in possible death or serious injury.
&DXWLRQ Improper use may result in injury or property damage.
'DQJHU
1HYHUXVHWKLVXQLWLQFRPELQDWLRQZLWKPHGLFDOHOHFWURQLFGHYLFHVVXFKDV
(1) Medical electronic implants such as pacemakers.
(OHFWURQLFOLIHVXSSRUWV\VWHPVVXFKDVDQDUWL¿FLDOKHDUWOXQJ
(3) Portable electronic medical devices such as an electrocardiograph.
This unit could cause these devices to malfunction, posing a considerable health risk to users
of these devices.
:DUQLQJ
Keep the unit out of the reach of young children. Contains small parts that may cause a choking
hazard if swallowed by infants.
'RQRWXVHWKHXQLWRQVOLSSHU\VXUIDFHVVXFKDVDZHWÀRRU
Do not jump onto the unit, or bounce on the unit.
Do not use this unit when your body and/or feet are wet, such as after taking a bath.
Stand on the unit bare-footed. Standing on the unit with socks on may cause you to slip and injure
yourself.
Do not step on the edge or display area of the unit.
People with disabilities, or who are physically frail, should always be assisted by another person
when using this unit.
,IEDWWHU\ÀXLGVKRXOGJHWLQ\RXUH\HVLPPHGLDWHO\ULQVHZLWKSOHQW\RIFOHDQZDWHU&RQVXOWD
physician immediately.
Do not use this product in hospitals, aircrafts or other environments where the use of radio waves is
restricted.
This product emits radio frequencies (RF) in the 2.4 GHz band. Do not use this product in locations
where RF is restricted, such as on an aircraft or in hospitals.
&DXWLRQ
Do not disassemble, repair, or remodel the unit.
Do not begin a weight reduction or exercise program without consulting a physician or healthcare
VSHFLDOLVW¿UVW6HOIGLDJQRVLVFRXOGLQMXUH\RXUKHDOWK
During measurement, make sure that no mobile phone or any other electrical devices that emit
HOHFWURPDJQHWLF¿HOGVLVZLWKLQFPRIWKLVGHYLFH7KLVPD\UHVXOWLQLQFRUUHFWRSHUDWLRQRIWKH
device and/or cause an inaccurate reading.
8VHEDWWHULHVVSHFL¿HGIRUWKLVXQLW'RQRWLQVHUWWKHEDWWHULHVZLWKWKHSRODULWLHVLQWKHZURQJ
direction.
Replace worn batteries with new ones immediately.
'RQRWGLVSRVHRIEDWWHULHVLQ¿UH

3
,IEDWWHU\ÀXLGVKRXOGJHWRQ\RXUVNLQRUFORWKLQJLPPHGLDWHO\ULQVHZLWKSOHQW\RIFOHDQZDWHU
Remove the batteries from this unit when you are not going to use it for a long period of time
(approximately three months or more).
Do not use different types of batteries together.
Do not use new and worn batteries together.
Always wash your feet before using the unit. If you are suffering from a foot infection or other skin
disease, you may cause infection to other people.
When the unit will be used by several people, wipe the unit with a damp cloth moistened with mild
detergent after using it. Then wipe it dry.
Do not use this unit for purposes other than described in this manual.
As this unit is a precision instrument, do not drop, vibrate, or apply strong shock.
'DWD7UDQVPLVVLRQ
Do not replace the battery while your measurement result is being transferred to your smart device.
This may result in the incorrect operation of your monitor and failure to transfer your measurement
result.
Do not place integrated circuit cards, magnets, metal objects, or other devices that emit
HOHFWURPDJQHWLF¿HOGVQHDUWKLVPRQLWRUZKLOH\RXUPHDVXUHPHQWUHVXOWLVEHLQJWUDQVIHUUHGWR\RXU
smart device. This may result in the incorrect operation of your unit and failure to transfer your
measurement result.
Incorrect Measurement
,QFRUUHFWPHDVXUHPHQWPLJKWRFFXUWRWKHIROORZLQJXVHUV
Elderly people (over 81 years old) / People with a fever / Body builders or highly trained athletes /
Patients undergoing dialysis / Patients with osteoporosis who have very low bone density /
Pregnant women / People with swelling.
Because the body composition such as body water might greatly deviate from the average value.

4
EN
Before using the unit
.QRZ<RXU8QLW
0DLQ8QLW
Foot Electrodes Foot Electrodes
Display
Feet (×4)
1
1
33
4
4
2
2
3
212))%XWWRQ
Press this button to turn on the power.
Press this button (2 seconds or longer) to turn off the power.
%OXHWRRWK%XWWRQ
Press this button to transfer the data manually.
Press this button (2 seconds or longer) to pair the unit with your smart device.
※This button is also usable when the power is off.
6(7%XWWRQ
3UHVVWKLVEXWWRQWRVHWRUFRQ¿UPWKHGDWD
$GYDQFH%XWWRQ
Press this button to advance.
Press and hold this button to advance rapidly during setting the date, time
and height.
'LVSOD\
Battery Symbol
(low/depleted)
Weight Symbol
Lights when only measuring the body weight.
SYNC Symbol
Bluetooth Symbol
Personal Number Symbol
Lights when personal number
is displayed.
Body Fat Percentage,
Visceral Fat Level,
Skeletal Muscle Percentage,
BMI Classification
Indicator

5
Before using the unit
,QVHUWDQG5HSODFHWKH%DWWHULHV
1. 2SHQWKHEDWWHU\FRYHURQWKHEDFNRIWKHXQLW
A hard object like a pen could be used.
2. ,QVWDOOWKHEDWWHULHVLQFRUUHFWSRODULW\DVPDUNHGLQVLGHWKH
EDWWHU\FRPSDUWPHQW
3. &ORVHWKHEDWWHU\FRYHU
%DWWHU\/LIHDQG5HSODFHPHQW
Ŷ $SSUR[LPDWHO\PRQWKV:KHQ$$$DONDOLQHEDWWHULHVDUHXVHGLQIRXUPHDVXUHPHQWVIRXU
GDWDWUDQVIHUVDQGIRXUSHUVRQVDGD\DWDURRPWHPSHUDWXUHRI&
The supplied batteries are for trial use only, they may have a shorter life.
Ŷ :KHQWKHGHSOHWHGEDWWHU\V\PERO DSSHDUVRQWKHGLVSOD\UHSODFHDOO
IRXUEDWWHULHVZLWKQHZRQHV
Replace all four batteries with new ones (same type) at the same time.
When the low battery symbol blinks, recommend to replace the batteries
with new ones ahead of time.
Ŷ 5HSODFHWKHEDWWHULHVDIWHUWXUQLQJRIIWKHSRZHU
Personal data stored in the unit are retained even if the batteries are removed.
Disposal of used batteries should be carried out in accordance with the national regulations for
the disposal of batteries.
Ŷ :KHQWKHEDWWHULHVDUHUHSODFHG\RXQHHGWRUHVHWWKHPHDVXUHPHQWXQLWGDWHDQGWLPH
5HIHUWR6HFWLRQ
If you have already paired with the “OMRON connect” app, press the button to communicate
with this app, then the date and time will be set automatically.
$ERXWWKH3RZHU2)))XQFWLRQ
Ŷ 3UHVVWKH EXWWRQVHFRQGVRUORQJHUWRWXUQRIIWKHSRZHU
Ŷ 7KHSRZHUDXWRPDWLFDOO\WXUQVRIILQWKHIROORZLQJFRQGLWLRQV
10 seconds after “Err” is displayed.
The unit is not used for 1 minute when “0.0 kg” is displayed.
The unit is not used for 3 minutes.
12
Depleted Battery
symbol

EN
Before using the unit
3DLUWKH8QLWZLWK<RXU6PDUW'HYLFH
1. 7XUQRQWKH%OXHWRRWKRI\RXUVPDUWGHYLFH
2. 'RZQORDGDQGLQVWDOOWKH³20521FRQQHFW´DSSRQWR\RXUVPDUWGHYLFH
You can choose one of the following 2 methods.
■6FDQWKH45FRGHWRJHWDFFHVVWRWKHIROORZLQJDGGUHVV
omronconnect.com/setup
QR code
■
6HDUFKWKH³20521FRQQHFW´DSSIURP³$SS6WRUH´RU³*RRJOH3OD\´
3. 2SHQWKHDSSRQ\RXUVPDUWGHYLFHDQGIROORZVHWXSDQGSDLULQJLQVWUXFWLRQV
,I\RXDOUHDG\KDYHWKH20521FRQQHFWDSSJRWR
Menu>Device>Add Device
NOTES
One smart device manages the data of one user.
If an app other than “OMRON connect” is used, data might not be transferred correctly.
Please read the utilization method and usage instruction within the app for details.

7
Before using the unit
4.
6HWWKH0HDVXUHPHQW8QLW'DWHDQG7LPH
6HWWLQJWKHPHDVXUHPHQWXQLWGDWHDQGWLPHLVQHFHVVDU\EHIRUHWDNLQJDPHDVXUHPHQWIRUWKH¿UVW
time or after replacing the batteries.
Date and time can be set from “OMRON connect” app as well.
1. 3UHVVWKH EXWWRQWRWXUQRQWKHSRZHU
“kg&cm” blinks on the display.
2. 6HWWKHPHDVXUHPHQWXQLW
Press the button to adjust and press the EXWWRQWRFRQ¿UP
The default measurement unit is “kg & cm”.
You can set the measurement unit to “lb & inch” or “st-lb & inch”.
3. 6HWWKHXQLWWRWKHFRUUHFWGDWHDQGWLPH
Press the button to adjust and press the EXWWRQWRFRQ¿UP
6HWWLQJUDQJHRI\HDUWR
Time is 24-hour system.
During setting the year, date, hour and minute, hold down the button to
advance rapidly in increments of 10.
After all the settings for the measurement unit, year, month, day, hour and
minute are displayed in that sequence, the power automatically turns off.
NOTES
If any mistake is made during the setting, press the button to turn off the
power and start from “Step 1” again.
The power turns off if the unit is not used for 3 minutes. Set the measurement unit, date and time
anew.
To modify the measurement unit, date or time, remove the batteries and wait for at least 20 seconds.
Then insert the batteries and reset again.
Year
Month
Day

8
EN
Before using the unit
5HJLVWHUWKH3HUVRQDO'DWD
For the measurement of body composition, it is necessary to register your personal data (birth date,
gender, height). The registered data can be stored for up to 4 persons.
The personal data can be registered from “OMRON connect” app as well.
1. 3UHVVWKH EXWWRQWRWXUQRQWKHSRZHU
The power turns on. Personal number “1” blinks. Birth date ( ) is displayed.
2. 6HOHFWDQGFRQ¿UP\RXUSHUVRQDOQXPEHU
Press the button to select your personal number and press the EXWWRQWRFRQ¿UP
3. 6HWWKHELUWKGDWH
Press the button to set the birth date and press the button to
FRQ¿UP
6HWWLQJUDQJHRI\HDUWR
During setting the year and date, hold down the button to advance
rapidly in increments of 10.
4. 6HWWKHJHQGHU
Press the button to set the gender (MALE) or (FEMALE)
and press the EXWWRQWRFRQ¿UP
5. 6HWWKHKHLJKW
Press the button to adjust the height and press the button
WRFRQ¿UP
Press continuously to rapidly advance in increments of 10 cm
(or 1 inch).
$IWHUDOOWKHVHWWLQJVDUHGLVSOD\HGIRU\RXUFRQ¿UPDWLRQ³NJ´
appears on the display.
Year
Month
Day

9
6. 6WHSRQWRWKHXQLWWRWDNHDPHDVXUHPHQWZKHQ³NJ´LVGLVSOD\HG
The data of body weight and body composition are recorded in the unit to support automatic
recognition.
After a while, the measurement results are indicated as follows.
7. 6WHSRIIWKHXQLWDIWHUWKHPHDVXUHPHQWUHVXOWVDUHGLVSOD\HG
The personal data registration is completed.
8. 3UHVVWKH EXWWRQVHFRQGVRUORQJHUWRWXUQRIIWKHSRZHU
To add new personal data, start from the “Step 1”.
Operating instructions
+RZWR7DNHD0HDVXUHPHQW$FFXUDWHO\
&RUUHFWSRVWXUHVGXULQJWKHPHDVXUHPHQW
Take a measurement on
DKDUGDQGÀDWÀRRU
1RWH
$FXVKLRQHGÀRRU
surface, such as a
mat or carpet, may
result in an inaccurate
measurement.
Step onto the unit with
your bare feet.
Place the arches of
your feet onto the
center of the unit.
1RWH
Stepping onto the
unit with socks or
footwear on will result
in an inaccurate
measurement.
Do not bend your knees
during measurement.
Other manuals for VIVA
1
This manual suits for next models
1
Table of contents
Other Omron Scale manuals

Omron
Omron HN289 User manual

Omron
Omron HBF-212 User manual

Omron
Omron HN-290T User manual

Omron
Omron HN-286 Setup guide

Omron
Omron HN-286 User manual

Omron
Omron HBF 306C User manual

Omron
Omron HBF-400 User manual

Omron
Omron HN-286 User manual

Omron
Omron FULL BODY SENSOR BODY COMPOSITION MONITOR AND SCALE... User manual

Omron
Omron HN288 User manual