Omron TH839S User manual

EARTHERMOMETER
Model TH839S
1883239-3C
Thank you for purchasing the ear thermometer TH839S.
This thermometer is designed with an advanced infrared and ambient temperature compensation technology for instantaneous
self-diagnosis and accurate temperature measurements. Do not use this device for Live & Dead decision or Safety related
applications. Please consult with doctor if you have health concerns.
If the thermometer detects a body temperature 37.5°C (or 99.5°F), three short beep sound will follow one long beep
sound to warn the user for potential fever.
1. In “Power Off” mode, press and hold the “Measure” button.
2. While holding it down, press the “ON/MEM” button.
3. Continue to press and hold the “Measure” button for 3 seconds after the power is on. The icon “°C” will be switched to icon “°F” .
You can also use the same process to change the LCD display from °F to °C.
1. Gently squeeze the opposite ends of the thermometer to pull off the probe cap.
NOTES:
•Do not use force to remove the cap.
•Always use a new and undamaged probe cover.
•Make sure the ear canal is clean.
2. Place a new probe cover on the connection ring.
NOTE: Make sure to place the “Adhesive Side” of probe cover “Upward.”
4. Push the connection ring until the “Click” sound. This means the probe cover has been installed
successfully.
NOTE: If the probe cover did not install well, the “ ” icon will flash on the LCD screen and
can’t take the ear temperature (will hear 4 beep sounds without reading shown on the LCD
when measuring) on the LCD screen. Please check the setting of the probe cover again.
3. Align the probe with the center of probe cover.
Insert the probe into the probe cover on the connection ring.
ATTACHING A PROBE COVER
1. Press “ON/MEM” button to power on.
The thermometer is ready for use after the ear icon stop flashing and two short beep sound.
2. Gently pull the ear back to straighten the ear canal and snugly position the probe into the
ear canal, aiming towards the membrane of the eardrum to obtain an accurate reading.
3. Measuring the ear temperature: Use the index finger to trigger. Press the “Measure”
button until you hear a long beep.
4. Power off:Press and hold the “ON/MEM” button to turn off the unit. Device will automatically shut down after 1 minute pending
to extend battery life.
NOTES:
•Holding the thermometer too long may causeahigher ambient temperaturereading of the probe. This could make the body
temperature measurement lower than usual.
•Before the measurement, please stay in a stable environment for 5mins and avoid exercising or bathing for 30mins.
•It is recommended that you measure 3 times with the same ear. If the 3 measurements are different, select the highest temperature.
•To avoid the risk of cross contamination, please clean the probe according to “Care and Maintenance” section after each use.
•Clinical repeatability: 0.18°C (< 1 year old), 0.17°C (1~5years old), 0.15°C (>5years old)
TAKING A MEASUREMENT
FEVER ALARM
SWITCHING BETWEEN FAHRENHEIT(°F) / CENTIGRADE(°C)
The reading of the thermometer is within the normal temperature range of 34°C to 42.2°C (93.2°F to 108.0°F).
After each measurement, the reading is saved into memory.
Press the “ON/MEM” button again to see the temperature stored.
The thermometer provides 9 sets memory for the measurements.
Device stabilization in process.
Temperature taken is higher than 42.2°C
(108.0°F).
Device can not be powered on to the ready
stage.
Temperature taken is lower than 34.0°C
(93.2°F).
Error 5~9, the system is not functioning
properly.
The ambient temperature is not within the
range between 10°C and 40°C (50°F ~104°F).
The device showing a rapid ambient
temperature change.
Measurement before device stabilization.
Battery is low and no more measurements are
possible.
Check the integrity of the probe cover and take a
new temperature measurement.
Change with a new battery.
Make sure the probe cover is clean and take a new
temperature measurement.
Unload the battery, wait for 1 minute and repower it.
If the message reappears, please send the unit to
Omron local representative.
Allow the thermometer to rest in a room for at least
30 minutes at room temperature:
10°C and 40°C (50°F - 104°F).
Allow the thermometer to rest in a room for at least
30 minutes at room temperature:
10°C and 40°C (50°F - 104°F).
Replace the battery.
USING THE MEMORY FUNCTION
The probe is the most delicate part of the thermometer. Use with care when cleaning the lens to avoid damage.
Keep the unit dry and away from any liquids and direct sunlight.
The Probe should not submerge into any liquids.
NOTE: Please check the device if damaged once it drops. If unsure, please send the unit to Omron local representative.
CARE AND MAINTENANCE TROUBLESHOOTING
This device is supplied with one lithium cell (CR2032 x 1).
NOTE: To protect the environment, discard the used batteries in accordance with the local regulations
regarding waste disposal procedure. Disposal can be done at your retail store or at appropriate
collection sites.
1. Open the battery cover: Insert a pointed object into the battery cover pick hole. At the same time,
use thumb to remove battery cover.
2. Flip the battery out with a small screw driver.
3. Insert the new battery under the metal hook on the left side and press the right side of the battery
down until you hear a “click.”
NOTE: The positive (+) side UP and negative (-) side DOWN.
4. Replace the battery cover.
REPLACING THE BATTERY
SPECIFICATIONS
Wait until stops flashing.
Wait until stops flashing.
NOTES:
• The specifications may be changed without prior notice.
• Comply with ASTM E1965-98, EN12470-5:2003 Clinical thermometers-Part 5:Performance of infra-red ear
thermometers(with maximum device),IEC/EN60601-1-2(EMC),IEC/EN60601-1(Safety) standards.
• This thermometer converts the ear temperature to display its “oral equivalent.” (according to the result of the clinical
evaluation)
Manufacture Date: as the serial number (please open the battery cover, it is shown on the inside of the device.)
Ex.SN:E209A000001, the first “E” is External, the second number “2” is the manufacture year 2012, the third and the
fourth number “09” is the manufacture month, the others is the serial number.
Please read the instructions for use.
Product Type:
Model:
Power Supply:
Power Consumption:
Battery Life:
Sensing Unit:
Temperature Display:
Measurement Accuracy:
Measurement Range:
Operating Environment
Temp and Humidity:
Storage Environment
Temp and Humidity:
Transportation
Temp and Humidity:
Applied Part:
Weight:
External Dimensions:
Package Content:
Options:
Ear Thermometer
TH839S
3.0V DC, 1 CR2032 Lithium Button Battery
0.01 W
With a new battery approx. 2500 measurement
Thermopile
4-digit, °F display in 0.1 degree increments
3-digit, °C display in 0.1 degree increments
± 0.2°C (0.4°F) within 35.5°C-42.0°C (95.9°F to 107.6°F), ± 0.3°C (0.5°F) for other range
34.0°C (93.2°F ) to 42.2°C (108.0°F )
10°C (50°F) to 40°C (104°F), RH≦85%
-20°C (-4°F) to 50°C (122°F), RH≦85%
-20°C (-4°F) to 60°C (140°F), 10%≦RH≦95%
= type BF
Approx. 69g (with battery installed)
39 mm (w) × 151 mm (h) × 54 mm (d)
Test Battery (Lithium Button Battery CR2032), probe cap, 21 probe covers, connection ring, instruction manual.
Probe cover exclusively for TH839S, MC-EP2.
OMRON HEALTHCARE SINGAPORE PTE LTD.
Medical Technology Promedt Consulting GmbH
Altenhofstrasse 80, D-66386 St. Ingbert, Germany
438A Alexandra Road, #05-05/08, Alexandra Technopark
Singapore 119967
www.omron-healthcare.com.sg
Asia Pacific HQ
Radiant Innovation Inc.
1F, No.3, Industrial East 9th Road, Science-Based
Industrial Park, HsinChu, Taiwan 300.
WARNING
•Do not forcibly insert the probe in the ear.
•If you feel discomfort such as a pain during the measurement, stop using the unit immediately. It may injure the external auditory
canal.
•Do not use this unit if suffering from ear disease such as otitis externa or otitis media. It may worsen the condition.
•Do not use this unit when the external auditory canal is wet such as after swimming or taking a bath. It may injure the external
auditory canal.
•Conducting self-diagnosis based on the measurement results and/or treatment can be dangerous. Please follow the instructions of
your doctor. Self-diagnosis may worsen the symptoms.
•Do not use this unit without attaching a probe cover.
•If the probe cover becomes dirty with earwax or other substances, replace it with a new one.
•Correct measurement result may not be obtained if dirty probe covers are used.
•Proper installation of the probe cover ensures accurate measurements.
•If device is accidentally used without a probe cover, clean the probe as follows:
(a)Please use the cotton swab with the Alcohol (70% concentration) to clean the lens (on the inside of the probe).
(b)Allow the probe to fully dry for at least 1 minute.
•Only use one probe cover at a time.
•If there is any temperature difference between the places where the unit is stored and where you are going to measure, leave the
unit in the room where you are going to use it for more than thirty minutes to allow it to reach room temperature first, then
measure.
•If the ear is cold, wait until the ear is warmed up before taking a temperature measurement. The measured result may indicate low
when you use an ice bag or an ice pack or immediately after coming in from the outside in winter.
•Do not touch the infrared sensor with a finger or breathe on it.
•The probe is the most delicate part of the thermometer. Use with care when cleaning the lens to avoid damage.
•Do not attempt measurements when the thermometer is wet as inaccurate readings may result.
•Store the unit out of children's reach.
•In an emergency case, if a child swallows a battery or a probe cover, immediately consult with a doctor.
•Do not use a probe cover after someone else has used it. This can lead to cross infections such as otitis externa.
•Do not throw batteries into a fire. The battery may explode.
•Children may try to measure by themselves and may damage the ear.
GENERAL SAFETY PRECAUTIONS
•Do not apply a strong shock to, drop, step on, or vibrate the main unit.
•Do not use this unit other than for measuring the temperature in the human ear.
•Do not use a portable phone near the unit.
•The main unit is not waterproof. Be careful when handling this unit so that no liquid (alcohol, water, or hot water ) will get into
the main unit.
•Do not disassemble, repair, or modify the unit.
•When you inform your doctor of your temperature, make sure you state that you measured the temperature in the ear.
Place Adhesive Side Upward
noituloSmelborPegasseMrorrE
Caution Please read the instructions for use. Do not reuse
Manufacturer
BF type applied part Battery Recycling Paper Recycling
The CE mark and Notified
Body Registration Numbers,
the requirement of Annex II
from Medical Device
Directive 93/42/EEC are
met.
Indicates this device is subject to the
Waste Electrical and Electronic
Equipment Directive in the European
Union. To protect the environment,
dispose of useless device at appropriate
collection sites according to national or
local regulations.
Authorized representative
in the European
community.
Guidance and manufacturer’s declaration – electromagnetic emissions
The TH8xyz series is intended for use in the electromagnetic environment specified below. The customer or the user of the
TH8xyz series should assure that it is used in such an environment.
Emissions test Compliance Electromagnetic environment – guidance
RF emissions
CISPR 11
RF emissions
CISPR 11
Group 1
Class B
The TH8xyz series uses RF energy only for its internal function. Therefore,
its RF emissions are very low and are not likely to cause any interference
in nearby electronic equipment.
Harmonic emissions
IEC 61000-3-2
Voltage fluctuations/
flicker emissions
IEC 61000-3-3
Not applicable
Not applicable
The TH8xyz series is suitable for use in all establishments, including domestic
establishments and those directly connected to the public low-voltage power
supply network that supplies buildings used for domestic purposes.
Symbol Descriptions
Guidance and manufacturer’s declaration – electromagnetic immunity
The TH8xyz series is intended for use in the electromagnetic environment specified below. The customer or the user of the
TH8xyz series should assure that it is used in such an environment.
Immunity test Compliance
level Electromagnetic environment – guidance
Conducted RF
IEC 61000-4-6
Radiated RF
IEC 61000-4-3
Not
applicable
3 V/m
IEC 60601
test level
3 Vrms
150 kHz
to 80 MHz
3 V/m
80 MHz
to 2,5 GHz
Portable and mobile RF communications equipment should be used no closer to
any part of the TH8xyz series, including cables, than the recommended separation
distance calculated from the equation applicable to the frequency of the transmitter.
Recommended separation distance
where Pis the maximum output power rating of the transmitter in watts (W)
according to the transmitter manufacturer and dis the recommended separation
distance in meters (m).
Field strengths from fixed RF transmitters, as determined by an electromagnetic
site survey, a should be less than the compliance level in each frequency range b.
Interference may occur in the vicinity of equipment marked with the following
symbol:
80 MHz to 800 MHz
800 MHz to 2,5 GHz
d = 1,2
d = 1,2
d = 2,3
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection
from structures, objects and people.
a. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios,
amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the
electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured
field strength in the location in which the TH8xyz series is used exceeds the applicable RF compliance level above, the TH8xyz
series should be observed to verify normal operation. If abnormal performance is observed, additional measures may be
necessary, such as reorienting or relocating the TH8xyz series.
b. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
Guidance and manufacturer’s declaration – electromagnetic immunity
The TH8xyz series is intended for use in the electromagnetic environment specified below. The customer or the user of the
TH8xyz series should assure that it is used in such an environment.
Immunity test Compliance level Electromagnetic environment – guidance
Electrostatic
discharge (ESD)
IEC 61000-4-2
Electrical fast
transient/burst
IEC 61000-4-4
6 kV contact
8 kV air
6 kV contact
8 kV air
Not applicable
Floors should be wood, concrete or ceramic tile. If floors are covered
with synthetic material, the relative humidity should be at least 30 %.
Mains power quality should be that of a typical commercial or
hospital environment.
Mains power quality should be that of a typical commercial or
hospital environment.
Surge
IEC 61000-4-5 Not applicable
IEC 60601
test level
2 kV for power
supply lines
1 kV for input/
output lines
1 kV line(s) to
line(s)
2 kV line(s) to
earth
interruptions
and voltage
variations on
power supply
input lines
IEC 61000-4-11
<5 % UT
(>95 % dip in UT)
for 0,5 cycle
40 % UT
(60 % dip in UT)
for 5 cycles
70 % UT
(30 % dip in UT)
for 25 cycles
<5 % UT
(>95 % dip in UT)
for 5 sec
Mains power quality should be that of a typical commercial or
hospital environment. If the user of the TH8xyz series requires
continued operation during power mains interruptions, it is
recommended that the TH8xyz series be powered from an
uninterruptible power supply or a battery.
Power frequency magnetic fields should be at levels characteristic of
a typical location in a typical commercial or hospital environment.
Power frequency
(50/60 Hz)
magnetic field
IEC 61000-4-8
NOTE UT is the a.c. mains voltage prior to application of the test level.
Not applicable
3 A/m 3 A/m
Recommended separation distances between portable and
mobile RF communications equipment and the ME EQUIPMENT or ME SYSTEM
The TH8xyz series is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
The customer or the user of the TH8xyz series can help prevent electromagnetic interference by maintaining a minimum
distance between portable and mobile RF communications equipment (transmitters) and the TH8xyz series as recommended
below, according to the maximum output power of the communications equipment.
Rated maximum output
power of transmitter
W
For transmitters rated at a maximum output power not listed above, the recommended separation distance din meters (m) can
be estimated using the equation applicable to the frequency of the transmitter, where Pis the maximum output power rating
of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection
from structures, objects and people.
Separation distance according to frequency of transmitter
m
0,01 0,12 0,12 0,23
0,1 0,38 0,38 0,73
1 1,2 1,2 2,3
10 3,8 3,8 7,3
100 12 12 23
80 MHz to 800 MHz150 kHz to 80 MHz 800 MHz to 2,5 GHz
d = 1,2 d = 1,2 d = 2,3
耳套安装方式
1. 轻轻地拉开耳温计探头保护盖
注意:
.请勿强行拉开探头保护盖
.每次量测请使用干净、无破损的耳套
.确保耳道干净
2. 将一个全新耳套放入辅助环凹槽
注意:请确认将耳套 “黏着面”“朝上”放入辅助环。
(图 2)
3. 将耳温计的探头中心对准有耳套的辅助环中心装入(图 3)
4. 将辅助环压紧,直到听到喀嚓声,即表示耳套已安装成功。
注意:如果耳套没安装好, 耳套符号 " " 会一直闪烁且
无法进行量测(当量测时,会听到4声哔响且无法显示
任何数值)。此时请再度检查耳套安装。
耳温量测
1. 按下“电源及记忆按键”开机,屏幕上耳朵符号停止闪烁后,
并听到两声哔声,即可开始准备测量。
以得到准确的量测值。
2. 轻轻将耳朵向后拉使耳道变直,将探头贴紧耳道,对准耳膜,
3. 量测耳温:用食指轻按下“测量按键”直到听到哔声后放开。
4. 关机:久按“电源及记忆按键”可将耳温计关机。若一分钟
内未操作耳温计,则其会自动关机,以增长电池使用寿命。
注意:
.久握耳温计可能导致枪体侦测到较高的环境温度,间接误判人体体温而呈现较低温的读值出现。
.量测前,受测者请于恒温环境下静待 5分钟,并且避免于运动或沐浴后 30 分钟内进行量测。
.建议测量同一耳 3次,如果 3次测量的结果都不一样,请取最高值。
.为避免交叉感染,请于每次使用后,按照「维护与保养」确实清洁。
.临床重复性:0.18°C ( 1 岁以下),0.17°C (1 至5岁),0.15°C (5 岁以上)。
发烧警示
耳温计若量测体温 37.5°C(或99.5°F),会发出一长音后接三短哔哔声,以警示受测者可能发烧。
记忆功能
量测体温在正常温度范内,即 34°C至42.2°C (93.2°F至108.0°F),每次量测后,温度资料会自动记忆。
按下 "电源及记忆按键"可读取记忆量测值
耳温计总共可储存 9组记忆量测值
维护与保养
耳温计探头是最脆弱的部位,清洁时请小心以避免损害。
请保持耳温计干燥,不可浸水及阳光直接曝晒。
不可将探头浸入任何液体中
注意:若不小心摔落耳温计,请检查枪体是否受损。若无法确定,请送至当地的 Omron 代理商进行检查。
耳温计
型号:TH839S
1883230-0C
感谢您购买 TH839S耳温计。TH839S耳温计为具有红外
线感测、周遭环境温度补偿及自我侦测的功能。本产品
不得代替医师的诊疗,亦请勿自行将量测结果应用在医
疗行为及相关医疗判断上。
警告
.不要强行将探头放入耳内
.量测过程中,若感到不舒适,例如:疼痛,请立即停止使用耳温计,可能会损伤外耳道。
.如果患有耳疾,例如:外耳炎或中耳炎,请勿使用耳温计,可能会使症状恶化。
.当外耳道潮湿时,例如:游泳后或洗澡后,请勿使用耳温计,可能会损伤外耳道。
.根据测量结果进行自我诊断或治疗会有危险性,请按照医生指示,自我诊断可能会使症状恶化。
.请勿使用没有安装耳套的耳温计
.如果耳套脏污,并且附着耳垢或其它物质,请换装新耳套。
.如果使用脏污的耳套测量,可能无法获得准确的测量结果。
.正确安装耳套,以确保量测准确度。
.若不小心使用没有耳套的耳温计进行量测,使用后请依下列指示清洁探头:
(a) 请使用棉花棒沾酒精(浓度 70%)来清洁探头镜片(探头内部)
(b) 擦拭探头后,请静置 1分钟待其完全干燥。
.每次只使用一个耳套
.耳温计使用前,必须放置在周遭环境温度稳定的房间内 30 分钟。
.使用冰枕或冰袋降温,或冬天刚进屋就立即测量,都会使测量结果偏低。测量前,需待耳朵恢复正常温度。
.请勿用手触摸或呼气于红外线感应器
.耳温计探头是最脆弱的部位,清洁时请小心以避免损害。
.请保持耳温计干燥,耳温计潮湿时,可能导致测量结果不准确。
.放置于孩童拿不到的地方
.如果孩童误食电池或耳套,请立即送医。
.每次使用前,请换装新耳套,以避免交叉感染。
.请勿将电池丢入火源,可能引起电池爆炸。
.避免孩童自行量测,可能会损伤耳道。
一般安全注意事项
.请勿强烈撞击、摔落、踩踏或震动耳温计。
.请勿使用耳温计测量人体耳温之外的温度
.请勿将行动电话靠近耳温计
.耳温计是不防水的,请勿将耳温计浸水或放置于其它液体中,以避免损害。
.请勿自行拆解、修理或修改耳温计。
.当告知医生量测体温时,请务必说明量测温度为耳温。
请详细阅读使用说明书
华氏(°F)/摄氏(°C)转换
1. 在“关机模式”下,按住 “测量按键”不放手。
2. 同时按住 "电源及记忆按键"
3. "测量按键"持续按住 3 秒,此时屏幕温度单位由°C切换为°F。您可以使用相同步骤,切换回原来的温度测
量单位。
小探头
直径
=5.9mm
探头保护盖
探头镜片
探头
量测按键
液晶显示屏幕
电池盖安全孔
耳套
耳套
侦测器
电源及
记忆按键
电池及电池盖
图1
图2图3
将耳套黏着面朝上放入辅助环
耳套
辅助环
简易故障排除:
制造日期:序号(请打开电池盖,显示于耳温计里面。)
例如:SN:E209A000001,第一个 "E"为外形,第二个数位 "2" 为制造年份2012年,第三及第四的数位 "09" 是制
造月份,其余为序号。
热映光电股份有限公司
300台湾新竹科学工业园区新竹县工业东九路
三号一樓
Medical TechnologyPromedt Consulting GmbH
Altenhofstrasse 80, D-66386 St. Ingbert, Germany
AsiaPacificHQ OMRONHEALTHCARESINGAPOREPTELTD.
438AAlexandra Road, #05-05/08,Alexandra Technopark
Singapore 119967
www.omron-healthcare.com.sg
电池更换
本耳温计使用一颗锂电池 (CR2032 x 1)
注意:为了保护环境,请按照当地废弃物处理法规,将废电池送到您附近的店家或指定回收地点处理。
1. 开启电池盖:使用物品之尖锐端插入电池盖安全孔,同时用拇指将电池盖向外侧推出。
2. 使用小的螺丝起子,自电池下方将电池挑出。
3. 将新电池斜放入左侧金色卡勾下,再压下电池右侧,听到喀擦声即表示新电池已经装好。
注意:电池正极符号 (+) 朝上,负极符号 (-)朝下。
4. 装上电池盖
规格
产品名称: 耳温计
型号: TH839S
电源供给: 1颗CR2032 DC 3.0V钮扣锂电池
消耗功率: 0.01W
电池寿命: 一颗新电池可使用约 2500次量测
传感装置: 温差电堆
温度显示: 于°F显示模式下,最多会显示 4位数字,以 0.1 度为变化显示单位。
于°C显示模式下,最多会显示 3位数字,以 0.1 度为变化显示单位。
测量精确度: 体温于 35.5°C~42.0°C (95.9°F~107.6°F) 范围内为±0.2°C (0.4°F),其余为±0.3°C(0.5°F)。
测量范围: 34.0°C (93.2°F )~42.2°C (108.0°F )
操作环境
温度和湿度: 10°C (50°F)~40°C (104°F),RH≦85%。
储存环境
温度和湿度: -20°C (-4°F)~50°C (122°F),
,
RH≦85%。
运输温度和湿度: -20°C (-4°F)~60°C (140°F) RH≦≦ 95%10%。
应用部分:
内部电源, BF 型应用部分。
重量: 约69 克(含电池)
外观尺寸: 39 mm (w) × 151 mm (h) × 54 mm (d)
包装内容: 电池(CR2032钮扣锂电池)、探头保护盖、21 个耳套、辅助环、说明书
选配: TH839S专用耳套,MC-EP2。
注意:
.规格如有变更,恕不另行通知。
.符合 ASTM E1965-98实验室标准,EN12470-5:2003, IEC/EN60601-1-2(EMC), IEC/EN60601-1(Safety)标准。
.耳温计经由精密數据计算后转换成体温,经臨床实验证明后相当于口温的标准。
故障讯息 问题 解决方法
机器忙碌中 等候 停止闪烁
电池存量低无法量测 建议更换电池
无法正确读取量测值 等候 停止闪烁
机器显示环境温度快速转变 让耳温计在正常室温下 10°C至40°C (50°F至
104°F) 静候 30 分钟
环境温度在正常温度范围 10°C 至40°C
(50°F 至104°F) 之外
将耳温计放在正常室温下 10°C 至40°C (50°F
至104°F) 静候 30 分钟
故障 5~9
,为系统不正常工作。
取出电池,等候一分钟后再装上电池,重新操
作。如果故障讯息无法消除,请与当地的
Omron 代理商连络。
量测温度高过 42.2°C (108.0°F) 确认耳套是否完整后重新操作
量测温度低于 34°C (93.2°F) 确认耳套和镜片是否清洁后,重新量测。
开机后无法进入待机状态 请立即更换电池
符号说明
符合欧盟医疗仪器指令
93/42/EEC
不可重复使用
纸类回收
制造商
欧体授权代表
警告及注意事项
BF型应用部分
请仔细阅读使用说明书
电池回收
废弃电器/电子设备:欧盟法规信息。
为了保护环境,请按照当地废弃物处
理法规,将废弃设备送到您附近的店
家或指定回收地点处理。

Other Omron Thermometer manuals

Omron MC-343 User manual

Omron

Omron MC-343 User manual

Omron MC-600 User manual

Omron

Omron MC-600 User manual

Omron MC-301 User manual

Omron

Omron MC-301 User manual

Omron Eco Temp II User manual

Omron

Omron Eco Temp II User manual

Omron Gentle Temp 520 User manual

Omron

Omron Gentle Temp 520 User manual

Omron GentleTemp 510 User manual

Omron

Omron GentleTemp 510 User manual

Omron Gentle Temp 521 User manual

Omron

Omron Gentle Temp 521 User manual

Omron Flex Temp II User manual

Omron

Omron Flex Temp II User manual

Omron MC-514 with IntelliTemp User manual

Omron

Omron MC-514 with IntelliTemp User manual

Omron O-Temp III User manual

Omron

Omron O-Temp III User manual

Omron Eco Temp Smart User manual

Omron

Omron Eco Temp Smart User manual

Omron Eco Temp Basic User manual

Omron

Omron Eco Temp Basic User manual

Omron DIGITAL THERMOMETER MC-343 User manual

Omron

Omron DIGITAL THERMOMETER MC-343 User manual

Omron GentleTemp 510 User manual

Omron

Omron GentleTemp 510 User manual

Omron Eco Temp Smart User manual

Omron

Omron Eco Temp Smart User manual

Omron i-Temp User manual

Omron

Omron i-Temp User manual

Omron MC-110 User manual

Omron

Omron MC-110 User manual

Omron Gentle Temp 720 User manual

Omron

Omron Gentle Temp 720 User manual

Omron O-Temp III User manual

Omron

Omron O-Temp III User manual

Omron Flex Temp Smart User manual

Omron

Omron Flex Temp Smart User manual

Omron MC-520-E User manual

Omron

Omron MC-520-E User manual

Omron MC-246 User manual

Omron

Omron MC-246 User manual

Omron E5L-C Series User manual

Omron

Omron E5L-C Series User manual

Omron E5L-C Series User manual

Omron

Omron E5L-C Series User manual

Popular Thermometer manuals by other brands

Dostmann Electronic V215 Operating	 instruction

Dostmann Electronic

Dostmann Electronic V215 Operating instruction

Triplett IRT227 user manual

Triplett

Triplett IRT227 user manual

COMPANION WTR001 instruction manual

COMPANION

COMPANION WTR001 instruction manual

VisioFocus 06400 user manual

VisioFocus

VisioFocus 06400 user manual

Klein Tools IR5 instruction manual

Klein Tools

Klein Tools IR5 instruction manual

Perel CWT20 manual

Perel

Perel CWT20 manual

Lutron Electronics TM-947SD Operation manual

Lutron Electronics

Lutron Electronics TM-947SD Operation manual

ThermoPro TP-04 operating instructions

ThermoPro

ThermoPro TP-04 operating instructions

TFA Flash instruction manual

TFA

TFA Flash instruction manual

Xeecom VENTUS W040 operating instructions

Xeecom

Xeecom VENTUS W040 operating instructions

Dromex DH-IF-THERMO instructions

Dromex

Dromex DH-IF-THERMO instructions

Fluke 1560 Black Stack user guide

Fluke

Fluke 1560 Black Stack user guide

Land UNO user guide

Land

Land UNO user guide

YOKOGAWA TM10 instruction manual

YOKOGAWA

YOKOGAWA TM10 instruction manual

Trotec TP7 operating manual

Trotec

Trotec TP7 operating manual

PeakTech 5110 Operation manual

PeakTech

PeakTech 5110 Operation manual

Omega HH803U instruction sheet

Omega

Omega HH803U instruction sheet

SKF TKDT 10 Instructions for use

SKF

SKF TKDT 10 Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.