Oransi ERIK650A User manual

U S E R M A N U A L
ERIK650A
R E A D A N D S A V E T H E S E I N S T R U C T I O N S
A I R P U R I F I E R

welcome
W E A P P R E C I A T E Y O U C H O O S I N G O R A N S I
Y o u c a n e x p e c t t h e v e r y b e s t p e r f o r m a n c e
f r o m y o u r O r a n s i f o r r e m o v a l o f f i n e a i r
p a r t i c l e s w h e r e i t i s u s e d . I f y o u h a v e
q u e s t i o n s b e y o n d t h i s m a n u a l , f e e l f r e e t o
v i s i t o u r w e b s i t e O r a n s i . c o m o r c a l l o u r
t r a i n e d c u s t o m e r s e r v i c e s t a f f a t
8 8 8 . 2 8 1 . 3 9 4 8 . Y o u r a i r p u r i f i e r s e r i a l
n u m b e r c a n b e f o u n d o n t h e r a t i n g l a b e l .
S i n c e r e l y ,
T H E O R A N S I T E A M

I N D E X
safety precautions
air purifier overview
filter overview
maintenance
installing cover
troubleshooting
best practices
warranty program
05
07
11
12
13

first,
be safe.

S A F E T Y P R E C A U T I O N S
Do not attempt to service the air purifier in any way other than to replace or
clean the air filter.
This product operates at 120V 60Hz only.
Always unplug the power cord from the electrical outlet when the air purifier
is not in use or when changing the filter.
Never run the air purifier unless it is fully assembled.
Do not alter the plug in any way.
Always tum off the air purifier before unplugging the air purifier from the
outlet.
Do not place the cord near a heated surface.
Never operate the air purifier if the plug or cord is damaged or appears
damaged. Only qualified service personnel should ever replace or attempt to
replace a damaged power cord or plug.
Never use the power cord to pick up, carry, drag, pull, or lift the air purifier.
Do not pull the cord against or around sharp corners and edges.
Always remove the plug from its power outlet by holding onto the plug itself
and pulling gently.
Use care when operating the air purifier by keeping all foreign objects,
fingers, body parts, hair, loose clothing, jewelry, etc., away from openings.
Do not drop items into the air purifier.
Never touch the air purifier or its plug when your hands are wet.
If moving the air purifier, lift by the carrying handle.
Do not use outside.
Do not operate without the filters installed.
Only use in an upright position. Do not place anything on top of the air
purifier.
Use only as described in this manual.
Use only Oransi replacement filters.
Place air purifier on a flat floor.
This appliance has a polarized plug (one blade is wider than the other). To
reduce the risk of electric shock, this plug is intended to fit in a polarized
outlet only one way. If the plug does not fit fully in the outlet, reverse the
plug. If it still does not fit, contact a qualified electrician. Do not attempt to
by-pass this safety feature.
READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK, OR INJURY. PLEASE SAVE FOR REFERENCE.
W A R N I N G
T o R e d u c e T h e R i s k O f F i r e O r E l e c t r i c S h o c k , D o N o t U s e
T h i s F a n W i t h A n y S o l i d - S t a t e S p e e d C o n t r o l D e v i c e .
05

next, meet
your ERIK650A.
S K U : # E R I K 6 5 0 A

A I R P U R I F I E R O V E R V I E W
A GLANCE INSIDE THE ERIK650A
07
How To Use
Getting Started
Your air purifier comes with the filters installed. Your unit is ready to be plugged in
and in use.
Operating
Always operate indoors, preferably on a level surface. If used in the home, we
recommend operating the unit wherever you spend most of your time – typically a
bedroom or living area. Set the fan speed to a noise level that is comfortable for you.
In most cases you can run the air purifier on a very low fan speed setting so it is
quiet. If you have a larger living area you may want to run it on a higher fan speed
when you are not in the room and then run it on a low speed when you are present.
Casters
Erik comes with casters to help in moving the unit. Two of the casters have a wheel
lock and to ease movement so make sure they are unlocked when moving.

Filter Overview
Combination Pre-Filter
The pre-filter is a combination MERV15 particulate filter and treated GAC
(granular activated carbon). Our proprietary treated coconut carbon filter
(GAC) removes a wide variety of gases such as VOC’s, smoke, formaldehyde,
ozone, smog, and combustion gases. This filter should be replaced with every
9-12 months of use.
Main HEPA Filter
The main HEPA filter is rated at 99.99% at 0.3 microns. This filter should be
replaced with every 24-36 months of use or when the filter turns a dark grey
color.
More efficient and use up to 90% less power.
More reliable since it runs cooler.
More compact.
Quieter - no motor hum that you can get with an AC motor.
EC Advantages
Why does the motor/fan start and stop more slowly than an AC motor? EC
motors have a soft start programmed into the motor to limit the start-up
current the motor draws.The ramp down after power is removed is only a
function of the inertia of the fan and the friction of the bearing system. A
high quality bearing system will take longer to slow down and stop since the
friction is minimized (alignment is better, lubricant is better, etc.).
08
A I R P U R I F I E R O V E R V I E W
Power Switch
The Off/Reset switch at the back of the air purifier
serves two purposes: it controls power to the unit
and works as a circuit breaker. To operate the air
purifier the reset/On side of the switch must be
pressed down. There is no light with this switch so
it will not illuminate when on. This is to keep the
unit from generating light if used in a bedroom.

let's keep
each other
healthy.

FILTER REPLACEMENT
INDICATORS
M A I N T E N A N C E
10
SEE AIR PURIFIER OVERVIEW PAGE FOR REFERENCE.
How to Replace the Filters
Follow the steps on pages 7 and 8
to remove the cover and access
the filters. Most filter changes
will simply be a replacement of
the pre- filter. All of our used
filters can be placed directly in
the trash.
Reset the Filter Replace
Indicator
Press and hold the Filter Reset
button beneath the flashing light
for a few seconds. The light will
turn off and the filter counter will
reset.
Ordering Replacement Filters
Visit us at oransi.com or contact
our customer service team at 888-
281-3948.

The cover only fits one way. There is a notch in the bottom for the side where the
user interface is located.
Lower the cover onto the air purifier. When properly seated it will be as shown
above.
The key to getting the cover to engage with the safety switch is to ensure the cover
clasp seats with the clasp of the base of the air purifier on the user interface side.
We suggest you lower the cover onto the unit and then lift about one inch. Lower
the cover with the long sides pressed in so the cover rests inside the guides along
the bottom and ensure it seats with the clasps by the user interface. In lifting the
cover up and down you should hear the safety switch click like it's being engaged.
Press in on the long sides so the white cover rests in the guard rails along the
length of the air purifier as shown above. If the cover rests outside the guard
rails it may bend somewhat and may not make contact with the safety switch.
Clasp the latches on the user interface side first. You may need to lift up slightly
on the cover and pull back to get both latches to seat as shown below.
The latch from the top cover must rest into the other part of the latch on the
base of the air purifier.
Clasp the two latches on the user interface side first. Then clasp the latches on the
opposite side. If the latches on the opposite side do not latch, lift the cover slightly
(with the user interface side still latched) and re-seat so they can latch properly.
How to Install the Cover
1.
2.
3.
a.
b.
c.
4.
M A I N T E N A N C E
11
SEE AIR PURIFIER OVERVIEW PAGE FOR REFERENCE.

T R O U B L E S H O O T I N G
Using Your Oransi
Always operate your air purifier
indoors on a level surface.
Locate your air purifier wherever
you spend most of your time.
Typically, a bedroom, living
space, office waiting room, or
classroom. Set the fan speed to
a level that is comfortable for
you. Low settings are less
audible. In most cases, you can
run your air purifier on a very
low fan.
For larger areas, consider a
higher fan speed when you’re
absent and then turn the setting
lower when you return.
Air enters your Oransi at the
bottom and exits the top, so you
can place the unit anywhere in a
room. However, be careful that
curtains do not block air intake
or exit.
Turn the red Power switch to the Off position.
Turn this switch back to On.
If this does not fix the issue then the top cover is probably not making
proper contact with a safety switch inside the air purifier.
Remove the 4 clasps near the base and remove the top cover.
Press in on the safety switch (shown below) with power to the air
purifier. The fan should begin to run.
Re-install the cover as outlined below.
If your unit is not turning on or running properly try the following:
1.
2.
3.
a.
b.
c.
F O R A S S I S T A N C E
v i s i t w w w . o r a n s i . c o m
c a l l 8 8 8 - 2 8 1 - 3 9 4 8
o r e m a i l c s @ o r a n s i . c o m
12

warranty
O R A N S I W A R R A N T Y D I S C L A I M E R
The Air Purifier is operated in accordance
with the instructions provided in the
Oransi User Manual
The Air Purifier is connected to a proper
power supply (see voltage label on the
machine).
The unit shows no evidence of tampering,
mishandling, neglect, accidental damage,
modification, and/or repair by anyone
other than authorized Oransi service
personnel.
Replacement filters are purchased directly
from Oransi or an authorized dealer.
The ERIK650A Air Purifier carries a 10-year limited
warranty from the original purchase date. Oransi
will replace your air purifier provided the product
is determined to be defective as a result of faulty
material or workmanship while in normal use.
Oransi’s sole obligation under this warranty is to
replace or at Oransi’s discretion, to repair, free of
charge, all defective parts. This warranty will not
be valid if the unit is damaged by the user. Proof
of purchase may be required by Oransi’s warranty
service representative. All parts or units that are
replaced become the property of Oransi.
W a r r a n t y r e m a i n s i n e f f e c t o n l y i f :
1.
2.
3.
4.
Other manuals for ERIK650A
1
Table of contents
Other Oransi Air Cleaner manuals

Oransi
Oransi finn User manual

Oransi
Oransi OVH2311 User manual

Oransi
Oransi OI939 User manual

Oransi
Oransi OVHT9908 User manual

Oransi
Oransi OVHP44 User manual

Oransi
Oransi max User manual

Oransi
Oransi OVHPR0201 User manual

Oransi
Oransi AirMend User manual

Oransi
Oransi mod User manual

Oransi
Oransi EJ 120 User manual