manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Orbit
  6. •
  7. Timer
  8. •
  9. Orbit 62061-24E rA User manual

Orbit 62061-24E rA User manual

Other Orbit Timer manuals

Orbit 57894 User manual

Orbit

Orbit 57894 User manual

Orbit Daybreak User manual

Orbit

Orbit Daybreak User manual

Orbit 62056 User manual

Orbit

Orbit 62056 User manual

Orbit B-hyve User manual

Orbit

Orbit B-hyve User manual

Orbit 94874 User manual

Orbit

Orbit 94874 User manual

Orbit 57894 User manual

Orbit

Orbit 57894 User manual

Orbit B-hyve User manual

Orbit

Orbit B-hyve User manual

Orbit B-hyve User manual

Orbit

Orbit B-hyve User manual

Orbit WaterMaster 57114 User manual

Orbit

Orbit WaterMaster 57114 User manual

Orbit B-HYVE WT24 User manual

Orbit

Orbit B-HYVE WT24 User manual

Orbit 57874 User manual

Orbit

Orbit 57874 User manual

Orbit 57896-50 rJ User manual

Orbit

Orbit 57896-50 rJ User manual

Orbit 57932 User manual

Orbit

Orbit 57932 User manual

Orbit 94075 User manual

Orbit

Orbit 94075 User manual

Orbit 27894 User manual

Orbit

Orbit 27894 User manual

Orbit 27954 User manual

Orbit

Orbit 27954 User manual

Orbit 62034 User manual

Orbit

Orbit 62034 User manual

Orbit 57894 User manual

Orbit

Orbit 57894 User manual

Orbit 58910Z User manual

Orbit

Orbit 58910Z User manual

Orbit 58910 User manual

Orbit

Orbit 58910 User manual

Orbit 57096 User manual

Orbit

Orbit 57096 User manual

Orbit 57880 User manual

Orbit

Orbit 57880 User manual

Orbit WaterMaster 57674 Guide

Orbit

Orbit WaterMaster 57674 Guide

Orbit 57896-50 rJ User manual

Orbit

Orbit 57896-50 rJ User manual

Popular Timer manuals by other brands

SATO TM-29 instruction manual

SATO

SATO TM-29 instruction manual

Full Gauge Controls ICEMATIC quick start guide

Full Gauge Controls

Full Gauge Controls ICEMATIC quick start guide

CEI Ultrak T-3 instructions

CEI

CEI Ultrak T-3 instructions

Raindrip R675CT Installation & programming

Raindrip

Raindrip R675CT Installation & programming

Intermatic P1131 owner's manual

Intermatic

Intermatic P1131 owner's manual

Profile 010200280 instruction manual

Profile

Profile 010200280 instruction manual

Gizmo T4 instructions

Gizmo

Gizmo T4 instructions

Tekmar Timer 031 Data brochure

Tekmar

Tekmar Timer 031 Data brochure

Daikin DST301B61 Operation manual

Daikin

Daikin DST301B61 Operation manual

sisel ENDA ETM2432 manual

sisel

sisel ENDA ETM2432 manual

B&Q TE103 Installation and use instructions

B&Q

B&Q TE103 Installation and use instructions

Hozelock AC Plus 2700 instructions

Hozelock

Hozelock AC Plus 2700 instructions

GIC Eliro V7DDSS3Eliro V7DFTS3 user manual

GIC

GIC Eliro V7DDSS3Eliro V7DFTS3 user manual

Emos EMT400F quick start guide

Emos

Emos EMT400F quick start guide

FarmTek Polaris operating instructions

FarmTek

FarmTek Polaris operating instructions

Citizen ME2 series instruction manual

Citizen

Citizen ME2 series instruction manual

Primex OneVue Sync B100 install guide

Primex

Primex OneVue Sync B100 install guide

Rain Bird Optima PRT-4 owner's manual

Rain Bird

Rain Bird Optima PRT-4 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

START TIME
1. Turn dial to START TIME.
2. Using the +/- buttons, set your start time,
including AM and PM.
3. Turn dial to save changes
HOW LONG
1. Turn dial to HOW LONG.
2. Using the +/- buttons, select watering
duration from 1 to 240 minutes
3. Turn dial to save changes.
HOW OFTEN
1. Turn dial to HOW OFTEN.
2. Using the +/- buttons, set your watering
frequency. You can choose to water every 6
hours, 12 hours, or from 1 to 7 days.
NOTE: 1 is every day, 2 is every other day, etc.
3. Turn dial to save changes.
DIAL—Rotate the dial to customize your
watering schedule
RESET—Press to clear all programming
MANUAL/CLEAR—Press to water manually or to
clear programming within a specific program
+/- BUTTONS—Use these buttons to adjust time
and system setup
1 Outlet HOse Faucet timer
IMPORTANT PLEASE READ!
TIMER FEATURES
AUTO—Timer waters according to your
customized schedule
SET CLOCK—Set the time of day
START TIME—Select what time you would like
watering to start
HOW LONG—Determine how long to water
HOW OFTEN—Choose how often you will water
OFF—Turn off all watering
6:00
RESET
MANUAL
WHEN EXPECTING FREEZING
TEMPERATURES, TIMERS SHOULD
BE REMOVED FROM THE HOSE
FAUCET AND STORED INDOORS TO
AVOID POTENTIAL FREEZE DAMAGE.
FILTER TRAPS DIRT PARTICLES,
PROLONGING LIFE OF TIMER.
CLEAN FILTER REGULARLY AND
REPLACE IF WORN.
HOSE TAP
CONNECTION
+/-
BUTTONS
MANUAL/
CLEAR
FILTER
DIAL
RESET
QUICK START
INSTALLING THE BATTERIES
1. Remove the tray on the back of the timer by
sliding or pulling it out.
2. Insert two AA (1.5V) alkaline batteries
(not included) and replace the tray.
Note: Firmly replace the battery tray to ensure water resistance
and increase battery life. You will know the battery tray is fully
inserted if it locks in place and does not pull out easily.
Used up or dead batteries must be removed from the timer and
disposed of properly. Batteries should be removed from the timer
at the end of the watering season and replaced with new ones at the
beginning of the next watering season. Replace batteries when low
battery icon appears on display.
PROGRAMMING THE TIMER
SET CLOCK
1. Turn dial to SET CLOCK.
2. Using the +/- buttons, set the time of day,
including AM and PM.
3. Turn dial to save changes.
AM
AM
MINUTES
DAYS
OUTLET
AM
Printers are responsible
for meeting print
production requirements.
Any changes must be
approved by Orbit®.
Printed piece must meet
designated specifications
on this form.
© 2014 Orbit Inc.
This work is the property
of Orbit®, and cannot be
used, reproduced or
distributed in any way
without their express
permission.
Dieline
PMS
0000
Fold
PMS
0000
Product
Coverage
PMS
0000
Dims./
Callout
PMS
0000




Orbit®
1.801.299.5555
orbitonline.com Glue
Folded Flat Additional Information
PRIN TERS ARE
REQUIRED TO MATCH
ALL SP ECIFIED
PMS COLORS.
K
DATE: 02/09/2014
DESIGNER: JC MARKETING: AY
SOFTWARE: Adobe Indesign CS6
ARTWORK №: 62061-24E rA L:
W:
H:
000.000" W:
H:3.0"
3.0"
12.0"
6.0"
62061-24E rA
Congratulations! Your timer is now programmed.
Turn your dial to AUTO to allow your timer to
water according to programmed time, station,
duration, and frequency.
ADDITIONAL FEATURES
RAIN DELAY
Rain delay allows you to postpone watering for
a set period of time. To access the rain delay,
follow the steps below.
1. With the dial on AUTO, press the + button to
select a delay of 24 hrs, 48 hrs, or 72 hrs.
2. Screen will flash between clock and hours
remaining before programmed cycle resumes.
3. To remove rain delay, turn dial to OFF
and then back to AUTO.
MANUAL/HAND WATERING
This feature allows you to water without
interrupting your set schedule. To access this
feature, follow the steps below.
HRS
1. With the dial on AUTO, press the
MANUAL button.
2. Use the + and – buttons to select watering
time, from 1 to 240 minutes.
NOTE: There may be a slight delay between the time
the manual button is pressed and when watering begins.
To stop manual watering, turn the dial to OFF.
Turn the dial back to AUTO to resume your
programmed watering schedule.
Turning the dial to the OFF position at any time
during the day will reset the timer’s internal
timing. This will cancel all scheduled watering
times for the day until the next programmed
START TIME. This means if you turn the
dial back to AUTO the timer will not water
until the next day; beginning at your desired
programmed START TIME.
Example:
You have a 6:00 AM START TIME with HOW
OFTEN 6 hour intervals. If you turn the dial to
OFF at 10:00 AM today the timer will not water
until tomorrow at 6:00 AM. The 12:00 PM, 6:00
PM, and 12:00 AM watering times have been
cancelled for the day.
TROUBLESHOOTING
WATER DOES NOT COME ON AT DESIRED TIME.
CHECK IF:
• Clock is set to correct time,
including AM and PM.
• Start time is set to desired time, including
AM and PM.
• Rain Delay is on. Clear if necessary.
MANUAL
MINUTES
TIMER DOES NOT WATER.
CHECK IF:
• Timer is set to AUTO.
• Hose faucet is on.
• Batteries are low.
• Clock is set to correct time,
including AM and PM.
• Rain Delay is on. Clear if necessary.
WATER WON’T TURN OFF.
CHECK IF:
• HOW LONG is set to desired time.
WORKING WATER PRESSURE
Minimum: 25 psi
Maximum: 100 psi
WORKING TEMPERATURE
Maximum: Do not exceed 120°F
Minimum: Keep from freezing
WARNINGS
For outdoor use with cold water only.
© 2014 Orbit Irrigation Products, Inc.
All rights reserved. All trade names are
registered trademarks of respective
manufacturers listed.
Orbit
®
Irrigation Products, Inc.
North Salt Lake, UT 84054