T11P Visual Fault Locator Instructions for use
Products introduction

On/off button

Laser connector

Product features
This product uses a 650nm semiconductor laser as a light-
emitting device and is driven by a constant current source
to emit stable red light; it enters a single-mode or multi-
mode fiber after being connected to an optical fiber
interface to realize the function of fiber fault detection. It
is a fiber optic engineering construction and a fiber optic
network. An indispensable tool for maintenance, optical
device production and research.
650nm red laser.
Pulse and continuous wave operation.
Output power: 1MW, 10MW, 20MW, 30mw.
2.5 Universal connector.
30 hours operation (1MW).
1.25mm LC adapter (optional).
Metal Material.
Find fiber microbends, breaks and fiber damage.
Open the dust cap and insert
the optical fiber interface under test
into the laser connector.
Silicone cap
Ceramic ferrule
Pilot lamp
Power on/off button
Long press ” ”to turn on, the red indicator
light will light up, and the laser will output continuous
wave at the same time;(If the fiber is connected, red
light can be seen at the end of the fiber under normal
circumstances; if the tested fiber is disconnected,
there is no red light output at the end of the fiber).
Shortly press the power button, the indicator
light flashes, and the laser pulse wave is output at
the same time; short press again to turn off the red
light.
Under normal circumstances, it will automatically
shut down if there is no operation for 15 minutes to
extend the battery life.
Connector type

Common fault solutions

Product parameter


Tips
Contact us
NANJING ORIENTEK OPTICAL COMMUNICATION LTD
Mail: [email protected]
Add: Jianshan Industry Park, Liuhe District, Nanjing, Jiangsu, China
Web: www.orientekot.com
TEL: +86 17312230635
Fault prompt Possible cause
LED display weak Low battery
Unable to turn on Low battery or other
Solution
Charging
Restart or charge
Operating environment altitude: areas below
2000m above sea level
Operating environment
Output pow
Output wavelen
Laser type
Connector type
Modulation
frequency
working
temperature
Storage
temperature
Battery
weight
Shape size
650nm
FP/LD
2.5mm universal for FC,SC,FT
2Hz
-20 ~ 50(℃)
-20 ~ 50(℃)
AAA x 2 (Purchased separately)
80g
180 * 24mm
1mW 20mW 30mW
10mW
Please read all instructions and warnings before
using this product. Irregular use will cause
damage to the product or personal safety.
1)Please read carefully and correctly understand the warning
and operation instructions in the user manual before using
the red light pen;
2)Please use the red light pen in strict accordance with the
user manual;
3)Laser is harmful, especially eye protection. When laser working,
it is strictly prohibited to look directly at the red light;
4)The laser is a heating device. Generally, the higher the
temperature, the shorter the life of the laser. When using it, try
to avoid high temperature environments, and it is not recomm-
ended to use it for a long time;
6)When not in use for a long time, the lithium battery may self-
discharge. When the voltage is too low, it cannot be turned on.
Please charge it before using it;
5)After use, please cover the dust cap to prevent dust from
falling in;
7)After using for a period of time, please clean the interface with
a special optical fiber cleaning cotton swab.
Packing carton, host, quick guide.
Standard kit
ST FC SC LC (optionnel)

Other OrienTek Measuring Instrument manuals

OrienTek TPM-25m User manual

OrienTek

OrienTek TPM-25m User manual

OrienTek T15M User manual

OrienTek

OrienTek T15M User manual

OrienTek TFI-35 User manual

OrienTek

OrienTek TFI-35 User manual

OrienTek TPN-35 PON User manual

OrienTek

OrienTek TPN-35 PON User manual

OrienTek TFI-40 User manual

OrienTek

OrienTek TFI-40 User manual

OrienTek TPV-53 User manual

OrienTek

OrienTek TPV-53 User manual

OrienTek TPM-35m User manual

OrienTek

OrienTek TPM-35m User manual

Popular Measuring Instrument manuals by other brands

Analyticon Hemolyzer 5 Service manual

Analyticon

Analyticon Hemolyzer 5 Service manual

Eastron SDM72DM user manual

Eastron

Eastron SDM72DM user manual

NKT SuperK EXTREME instruction manual

NKT

NKT SuperK EXTREME instruction manual

Klein Tools LAN Scout Jr. 2 instruction manual

Klein Tools

Klein Tools LAN Scout Jr. 2 instruction manual

Sper scientific 300014 instruction manual

Sper scientific

Sper scientific 300014 instruction manual

Lovibond SD 60 quick start guide

Lovibond

Lovibond SD 60 quick start guide

ZLG CANREC Series user manual

ZLG

ZLG CANREC Series user manual

HydroPoint WaterCompass FM300 manual

HydroPoint

HydroPoint WaterCompass FM300 manual

Haefely 2823 quick start guide

Haefely

Haefely 2823 quick start guide

IBR IMB-pc1 instruction manual

IBR

IBR IMB-pc1 instruction manual

DeFelsko PosiTector 6000 manual

DeFelsko

DeFelsko PosiTector 6000 manual

Divesoft DNA 8460 user manual

Divesoft

Divesoft DNA 8460 user manual

OneProd FALCON Safety instructions

OneProd

OneProd FALCON Safety instructions

MR MESSKO EI100 operating instructions

MR

MR MESSKO EI100 operating instructions

Jain Technology XONIC-100P user manual

Jain Technology

Jain Technology XONIC-100P user manual

Gutermann HISCAN Safety Guidelines & Installation Manual

Gutermann

Gutermann HISCAN Safety Guidelines & Installation Manual

ISKRAEMECO MT880 Installation and maintenance manual

ISKRAEMECO

ISKRAEMECO MT880 Installation and maintenance manual

Endress+Hauser Levelflex FMP56 Brief operating instructions

Endress+Hauser

Endress+Hauser Levelflex FMP56 Brief operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.