manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. OrienTek
  6. •
  7. Measuring Instrument
  8. •
  9. OrienTek T15M User manual

OrienTek T15M User manual

T15M small stable light source instruction manual
Products introduction

Backlight control

Wavelength selection

Carrier output

Power-on and power-saving function settings
T15M stable light source, which is characterized by output
optical power, wavelength and spectrum.The width is stable
and the range of change is small. While the appearance is
upgraded, LED lighting is added.Provide 1310nm and 1550nm
dual-wavelength laser output, mainly used for FTTX
network.And fiber optic testing. When combined with an
optical power meter, it is used to measure optical power and
end End-to-end optical loss.
1
3
9
8
4
5
6
12
11
10
7
2
nm
1310
HZ
270
CW/HZ
KLS-25m Light Source
Auto-o�
OLS interface:
1
LED lighting
2
Display
3
Enter key
4
LED key
5
CW/HZ key
6
On/off key: turn on or off the device
7
Automatic shutdown
9
Frequency
10
Power supply battery
8
Unit
11
Wavelength
12
The equipment will turn on
after pressing the " " key. Press
this button again for more than
two seconds to shut down.
This instrument has power saving
function, normal there is no operation
for about ten minutes after booting,
The device will automatically shut down.
If you needa screen Shield this function
to keep the equipment working all the
time Status, just short press "on" when
booting Key, "Auto-off" at the bottom
left of the meter display. Disappearing
means that the power saving function
is cancelled.
nm
1310
HZ
270
CW/HZ
Auto-off
Auto-off
nm
1310
HZ
270
CW/HZ
Auto-o�
CW/HZ
In the power-on state, the backlight
will automatically turn off after a
period of time. After turning off, press
any key to activate the backlight. The
backlight is used to illuminate the
instrument display at night or in dark
places.
λ
1310nm
1550nm
nm
1310
HZ
270
CW/HZ
KLS-25m Light Source
Auto-o�
According to the needs of the project,
select the corresponding wavelength to
match the optical power meter. After the
meter is turned on, press the "output
wavelength" key, the output wavelength
and length will be switched to the
corresponding wavelength in turn, and
will be displayed on the display. The
laser light source of this series can
provide 1310nm and 1550nm
dual-wavelength laser output according
to demand.
nm
1310
HZ
270
CW/HZ
Auto-o�
CW/HZ
HZ
270 HZ
1000
HZ
2000
In the actual project, it is necessary to
load the audio carrier in the optical signal
to identify the optical fiber. The equip-
ment contains three carrier frequencies,
which are 270Hz, 1KHZ, and 2KHz. After
pressing the "modulated carrier" key, the
equipment will load different carriers in
sequence, and the display will be
displayed at the same time. The current
carrier frequency will be displayed on the
screen.
Contact us
Calibration function description

Products introduction

Tips

NANJING ORIENTEK OPTICAL COMMUNICATION LTD
Mail: [email protected]
Add: Jianshan Industry Park, Liuhe District, Nanjing, Jiangsu, China
Web: www.orientekot.com
TEL: +86 17312230635

Products specification
nm
1310
HZ
270
CW/HZ
Auto-off
Press the "illumina-
tion" button to turn on the
LED lighting, which is
convenient for construction
and operation in a dark
environment.
2.5mm universal interface + SC adapter
Output power -5dB
Wavelength 1310nm~1550nm
Anti-falling 2m
Low voltage function display
Waterproof keys suitable for various
outdoor environments
Silicone case protection design
Equipped with LED lights to facilitate work
in dark environments
Wavelength(nm) 1310/1550nm
Output Power -5dB
Optical connector SC+2.5mm universal (1.25mm LC optional)
Power supply Alkaline batteries (2 AAA 1.5V batteries)
Stable output ±0.05dB/15mins; ±0.1dB/ 8 hours
Modulation frequency CW, 270Hz, 1KHz, 2KHz
volume and weight 130x65x35mm / 180g
Operating environment altitude:
areas below 2000m above sea level
Use environment
Please read all instructions and warnings before
using this product. Irregular use will cause.It will
damage the product or personal safety.
1) Do not store this product in high temperature, strong light
and strong magnetic field environment, do not put it pace in
other harsh environments such as fire sources.
2)Improper use of the product may easily cause the product
itself or may endanger personal property Safety.
3)If the consumer violates the product manual and improper
use, the personal and financial Property damages will bear all
consequences, and the company will not bear any legal
responsibility.
4)Non-professionals are strictly forbidden to decompose
this product.
5)Avoid using electrical appliances or loads that exceed the
output current of this product (the circuit will protect
Protection, no output).
6)Avoid strong physical effects, including knocking, throwing,
trampling, squeezing, etc.
Packing carton, stable light source,
certificate, instruction manual
Standard kit
Interface
accessory SC FC ST

Other OrienTek Measuring Instrument manuals

OrienTek TFI-40 User manual

OrienTek

OrienTek TFI-40 User manual

OrienTek TPV-53 User manual

OrienTek

OrienTek TPV-53 User manual

OrienTek TPM-35m User manual

OrienTek

OrienTek TPM-35m User manual

OrienTek TPN-35 PON User manual

OrienTek

OrienTek TPN-35 PON User manual

OrienTek TPM-25m User manual

OrienTek

OrienTek TPM-25m User manual

OrienTek T11P User manual

OrienTek

OrienTek T11P User manual

OrienTek TFI-35 User manual

OrienTek

OrienTek TFI-35 User manual

Popular Measuring Instrument manuals by other brands

IFM Electronic Efector 300 SD8000 operating instructions

IFM Electronic

IFM Electronic Efector 300 SD8000 operating instructions

LaserLiner DampFinder Plus manual

LaserLiner

LaserLiner DampFinder Plus manual

Well T812 quick start guide

Well

Well T812 quick start guide

THORLABS INTUN TL 1550-T manual

THORLABS

THORLABS INTUN TL 1550-T manual

CASTLE Vexo H operating manual

CASTLE

CASTLE Vexo H operating manual

Niigata seiki TVC-15S instruction manual

Niigata seiki

Niigata seiki TVC-15S instruction manual

Endress+Hauser Prosonic S FMU90 Brief operating instructions

Endress+Hauser

Endress+Hauser Prosonic S FMU90 Brief operating instructions

AEMC 6550 Quick start user guide

AEMC

AEMC 6550 Quick start user guide

Fluke PG7607 Operation and maintenance manual

Fluke

Fluke PG7607 Operation and maintenance manual

Hifonics TPS-MR1 Operator's guide

Hifonics

Hifonics TPS-MR1 Operator's guide

Aquavx Pro quick start guide

Aquavx

Aquavx Pro quick start guide

INWATER TECHNOLOGIES TGP Tracker user manual

INWATER TECHNOLOGIES

INWATER TECHNOLOGIES TGP Tracker user manual

Swema SwemaMan 7 operating instructions

Swema

Swema SwemaMan 7 operating instructions

YOKOGAWA vigilantplant DM8 user manual

YOKOGAWA

YOKOGAWA vigilantplant DM8 user manual

Praktica LRF-7 manual

Praktica

Praktica LRF-7 manual

NI PXIe-4190 Getting started

NI

NI PXIe-4190 Getting started

BizLine BIZ 700 058 instruction manual

BizLine

BizLine BIZ 700 058 instruction manual

Teledyne Lecroy PP011-2 Operator's manual

Teledyne Lecroy

Teledyne Lecroy PP011-2 Operator's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.