manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. OrienTek
  6. •
  7. Measuring Instrument
  8. •
  9. OrienTek TPV-53 User manual

OrienTek TPV-53 User manual

TPV-53 power meter User Manual
Products introduction
Power on/Auto power off


Optical power reference value setting

Optical power wavelength switching

VFL function
After short press the power button,
the meter will turn on and automatically
start the automatic shutdown function.
The default automatic shutdown time is
10 minutes. To cancel this function, press
and hold the power button when the power
is turned on. When the power button dis-
appears, the automatic shutdown will be
canceled.
Insert the fiber under test into the
VFL interface, press the VFL key to enter
the VFL test interface.
270HZ
270HZ
TPV-53 is a combination of optical power meter and VFL. Among
them, the optical power module can be used to measure the optical
power in mw, dB, dBm within the wavelength range of 850~1700nm,
with high display resolution. There are seven wavelengths calibration
points at 850nm, 980nm, 1300nm, 1310nm, 1490nm, 1550nm and
1625nm. It can display both linear and non-linear optical power at the
same time, which can be used for direct measurement of optical power
and relative measurement of optical link loss. The VFL module provides
650nm visible laser output, the test distance can reach 10km, and the
output power can reach 1mW/10mW/20mW. It is suitable for
single-mode or multi-mode fiber measurement and can identify
optical jumpers, jumper boards, distribution frames, and connectors
fault at the place.The instrument has a continuous backlight display
function, a large LCD display, making the measurement work more
conveniently and quickly,it is the construction of cable television
systems, optical fiber communications and other fields Indispensable
equipment for maintenance.
OPM interface
VFL interface
Display
Wavelength
switch key
VFL key: start
red light
detection function
REF/dB key: Short
press the dB unit
to switch
On/off key
Wavelength
Automatic
shutdown
Frequency
Battery power
Unit
Numerical value
270
P absolute power = 10lgP linear power / 1mW
P relative power = P absolute power-
P reference power
Insert the fiber which is under test into the
OPM interface.After booting, enter the
optical power meter interface, short press
the "REF" key to set the current power value
as the reference power, which can achieve
relative optical power test (insertion loss test)
or absolute power test, enter the relative
power test mode at the bottom of the screen
Display insertion loss (dB).The screen displays
the reference value; short press the "dB" key
to switch between linear power and absolute
power display.The units of linear power,
absolute power, and relative power are nW,
dBm, and dB respectively.
REF/dB
On the optical power meter interface, short
press the "λ" key to switch the measurement
wavelength, select 7 different test
wavelengths, 850nm/980nm/1300nm/
1310nm/1490nm/1550nm, 850nm, 1625nm
to ensure the accuracy of the test, select
the wavelength should be consistentwith the
wavelength of the measured optical signal.
λ
850nm 980nm1300nm
1310nm 1490 nm
1550nm 1625 nm
270
Standard configuration
Contact us
NANJING ORIENTEK OPTICAL COMMUNICATION LTD
Mail: [email protected]
Add: Jianshan Industry Park, Liuhe District, Nanjing, Jiangsu, China
Web: www.orientekot.com
Calibration function description

Common fault solutions

Tips

TEL: +86 17312230635

Products features

Products features
Please read all instructions and warnings before
using this product. Irregular use will cause.It will
damage the product or personal safety.
Operating environment altitude:
areas below 2000m above sea level
Use environment
Keypad Function
REF/dB Add 0.1dB
Shut down
λReduce 0.1dB
Save
Press the VFL+REF keys at the same time to enter the calibration mode,
and Cal will be displayed at the bottom of the screen.The next operation
is only valid in the calibration mode. Enter key for downward adjustment,
REF/dB key for upward adjustment.After adjustment, press VFL to save.
Fault prompt Possible Causes
LCD display is weak Low battery
Unable to boot display
The optical power value
is abnormal
Low battery or other
Connector failure/dirty
Solutions
Replacement battery
Reboot or replace battery
Reconnect the connector
or clean the sensor
Two in one compact and convenient.
2.5mm universal connection is suitable for FC/SC/ST connector.
Testing wavelength 850-~1625nm.
Testing range -70~+10dBm / -50~+26dBm.
Resolution 0.01db.
High-quality imported laser head, penetrating.
distance up to 10 kilometers.
Waterproof keys suitable for various outdoor environments.
Soft rubber shell protection, 2m fall prevention.
Packing carton, optical power meter host,
certificate, instruction manual.
1)Do not store this product in high temperature, strong light
and strong magnetic fields, and do not place it in other harsh
environments such as fire sources.
2)Improper use of the product may easily cause the product
itself or may endanger personal property safety.
3)If consumers violate the product manual and improperly
use it, the personal and property damage caused by it will bear
all the consequences, and the company will not bear any legal
responsibility.
4)Non-professionals are strictly prohibited from disassembling
this product.
5)Avoid using electrical appliances or loads that exceed the
output current of this product (the circuit will be protected and
there will be no output).
6)Avoid strong physical effects, including knocking, throwing,
trampling, squeezing, etc.
Calibration wavelength(nm)
Probe type
Power testing range(dBm)
Calibration accurancy
Display nuit
Optical adaptor type
Ato off(Min)
Dimension(mm)
850/980/1300/1310/1550/1625
InGaAs
-70~+10/-50~+26
±0.02dB
dB/dBM/uW
Power testing mode
650
Single & Multi mode fiber
10
For SC,FC,ST
10up
Alkaline Battery(3AA 1.5v batterles)
-20~+75
-40~+85
100 hours (backlight off state)
50(Typ)
95% RH from 0~40
10
VFL testing mode
Central wavelength(nm)
Fiber compatibility
Output powe(mW)r
Optical adaptor type
Detection Distance(km)
Battery
Working temperature(℃)
Storage temperature(℃)
Automatic shutdown time(min)
Battery keeps working(h)
Battery life(hrs)
Relative Humidity(℃)
2.5mm universal+SC
88.5x57x19.5
5

Other OrienTek Measuring Instrument manuals

OrienTek TPN-35 PON User manual

OrienTek

OrienTek TPN-35 PON User manual

OrienTek TFI-40 User manual

OrienTek

OrienTek TFI-40 User manual

OrienTek TFI-35 User manual

OrienTek

OrienTek TFI-35 User manual

OrienTek T15M User manual

OrienTek

OrienTek T15M User manual

OrienTek T11P User manual

OrienTek

OrienTek T11P User manual

OrienTek TPM-35m User manual

OrienTek

OrienTek TPM-35m User manual

OrienTek TPM-25m User manual

OrienTek

OrienTek TPM-25m User manual

Popular Measuring Instrument manuals by other brands

CWP Accurate pH 9.0 operating instructions

CWP

CWP Accurate pH 9.0 operating instructions

Mitsubishi Electric EMU4-FD1-MB user manual

Mitsubishi Electric

Mitsubishi Electric EMU4-FD1-MB user manual

IMI SENSORS EX615A42 Installation and operating manual

IMI SENSORS

IMI SENSORS EX615A42 Installation and operating manual

ACOEM Fixturlaser Laser Kit Quick tips

ACOEM

ACOEM Fixturlaser Laser Kit Quick tips

DeWalt LaserChalkLine DW088 instruction manual

DeWalt

DeWalt LaserChalkLine DW088 instruction manual

Nippon EMP-3 instruction manual

Nippon

Nippon EMP-3 instruction manual

Endress+Hauser PROline promag 10 P technical information

Endress+Hauser

Endress+Hauser PROline promag 10 P technical information

PCB Piezotronics 3501A122KG Installation and operating manual

PCB Piezotronics

PCB Piezotronics 3501A122KG Installation and operating manual

GESTRA LRG 16-4 Installation & operating manual

GESTRA

GESTRA LRG 16-4 Installation & operating manual

CITO SpectraldenCITOmeter manual

CITO

CITO SpectraldenCITOmeter manual

Fluidwell F112-A manual

Fluidwell

Fluidwell F112-A manual

Hanna Instruments HI97715 instruction manual

Hanna Instruments

Hanna Instruments HI97715 instruction manual

KROHNE OPTISONIC 7060 Electrical & mechanical installation manual

KROHNE

KROHNE OPTISONIC 7060 Electrical & mechanical installation manual

Projekt Elektronik FM 302 operating manual

Projekt Elektronik

Projekt Elektronik FM 302 operating manual

ETAS XETK-S20.1B user guide

ETAS

ETAS XETK-S20.1B user guide

X-Rite i1Pro quick start guide

X-Rite

X-Rite i1Pro quick start guide

3B6 SLIM Operator's manual

3B6

3B6 SLIM Operator's manual

Admag AXW500G installation manual

Admag

Admag AXW500G installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.