TPN-35 PON Optical Power Meter User Manual
Products introduction
Calibration


Set threshold

View threshold range

Clear threshold
Press the P/F key to enter the threshold
interface, if the value more than the value
set before,it will be showed in green,means
pass, if it is close to the value set,then showing
in yellow,means warning,if less than the set
value,it will be displayed in red,means failure.
TPN-35
The meter will turn on after pressing the
" " key,press this key again for more
than two seconds to turn off the instrument.
Long press OK to enter the
calibration page,after calibration,
press OK to save.
TPN-35
Long press the TH key to enter the
threshold page,threshold setting
from large value to small value.
TPN-35
TH
+
In the shutdown state, first press the
TH button and then press the power
button,Clear the modified threshold and
return to the original factory setting valve.
TPN-35
TH
+
This PON power meter adopts a TFT high-definition
LCD display,it is designed for OLT equipment which is
foucs on online testing, it is very suitable for FTTx/
PON service adjustment or maintenance usage. It can
test and measure signal power for voice, data and
video connections. Allows you to quickly evaluate the
power level of the network, the USB port can transmit
data quickly,up to 1,000 measurement items can be
saved at one time, it is an indispensable tool for
construction and maintenance in the PON system, the
silicone protective cover can prevent accidental falls
drop or other damage.
ONT port OLT port
Auto shutdown icon
Wavelength
Power supply battery
P/F key to enter
threshold page
Confirm button
REF/dB key
Shut down button
Numerical value
TFT HD LCD display
Data saving
Enter the threshold page
TPN-35
1
2
TPN-35, USB cable, quick guide.
Standard configuration
Contact us
NANJING ORIENTEK OPTICAL COMMUNICATION LTD
Mail: [email protected]
Add: Jianshan Industry Park, Liuhe District, Nanjing, Jiangsu, China
Web: www.orientekot.com
Data preservation

Tips

TEL: +86 17312230635
Save the current test data:
Long press this button on the test
page to save the current test data,
tap to view stored data.
Clear saved data:
In the shutdown state, first press the
right arrow key and then press the
power button to clear data records.
TPN-35


Products features
Products Specification
The meter test threshold can be set through the
management software.
Automatic shutdown (can be cancelled).
Users can test 1490nm, 1550nm in PON network.
at the same time,1310nm three wavelengths.
Simultaneously measure and display different PON
architectures, data and video signals.
The instrument provides 5 sets of thresholds to choose
from, with pass, warning, and fail modes.
Manual calibration.
Measuring wavelength
Sensor type
Linearity
Isolation
With filtering function
1490nm wavelength >40dB 1310nm wavelength >40dB 1310nm wavelength >40dB
1550nm wavelength >30dB
Less than 1.5dB
1260~1360 1480~1500
1310nm 1490nm 1550nm
InGaAS
1539~1565
-40dBm~+16dBm -50dBm~+16dBm
0.01dB
-50dBm~+23dBm
10 groups are set by the host computer
1310nm/1490nm/1550nm
-10℃~+50℃
0%~95%RH
SC/UPC(Other connectors are optional)
3 AA batteries
900 sets
1490nm wavelength >30dB
1550nm wavelength >40dB
Measuring range
Power supply
Connector type
Relative humidity
Working temperature
Data storage
Calibration wavelength
Threshold setting
Display resolution
Inherent uncertainty
Measurable optical
frequency broadband
Insertion loss in
penetration mode(dB)
0.5dBm 1nW@1550nm
0.2dB@1550nm≥-40dBm
Please read all instructions and warnings before
using this product. Irregular use will cause.It will
damage the product or personal safety.
Operating environment altitude:
areas below 2000m above sea level
Use environment
1) Do not store this product in high temperature, strong light
and strong magnetic field environment, do not put it pace in
other harsh environments such as fire sources.
2)Improper use of the product may easily cause the product
itself or may endanger personal property Safety.
3)If the consumer violates the product manual and improper
use, the personal and financial Property damages will bear all
consequences, and the company will not bear any legal
responsibility.
4)Non-professionals are strictly forbidden to decompose
this product.
5)Avoid using electrical appliances or loads that exceed the
output current of this product (the circuit will protect
Protection, no output).
6)Avoid strong physical effects, including knocking, throwing,
trampling, squeezing, etc.

Other OrienTek Measuring Instrument manuals

OrienTek T11P User manual

OrienTek

OrienTek T11P User manual

OrienTek TPV-53 User manual

OrienTek

OrienTek TPV-53 User manual

OrienTek TFI-40 User manual

OrienTek

OrienTek TFI-40 User manual

OrienTek TPM-25m User manual

OrienTek

OrienTek TPM-25m User manual

OrienTek TPM-35m User manual

OrienTek

OrienTek TPM-35m User manual

OrienTek T15M User manual

OrienTek

OrienTek T15M User manual

OrienTek TFI-35 User manual

OrienTek

OrienTek TFI-35 User manual

Popular Measuring Instrument manuals by other brands

Keysight Technologies M980xA PXIe quick start guide

Keysight Technologies

Keysight Technologies M980xA PXIe quick start guide

Trace2O METALYSER FIELD PRO HM3000 instruction manual

Trace2O

Trace2O METALYSER FIELD PRO HM3000 instruction manual

Rice Lake iRite 920i installation instructions

Rice Lake

Rice Lake iRite 920i installation instructions

RS PRO RS-90 instruction manual

RS PRO

RS PRO RS-90 instruction manual

Evoqua Wallace & Tiernan SFC-SC manual

Evoqua

Evoqua Wallace & Tiernan SFC-SC manual

ELC MiniStore 3 user manual

ELC

ELC MiniStore 3 user manual

VOLTCRAFT AM-72X72 operating instructions

VOLTCRAFT

VOLTCRAFT AM-72X72 operating instructions

HBM T10FM Mounting instructions

HBM

HBM T10FM Mounting instructions

Pfeiffer Vacuum PBR 260 operating instructions

Pfeiffer Vacuum

Pfeiffer Vacuum PBR 260 operating instructions

Brolight BIM-7001 user manual

Brolight

Brolight BIM-7001 user manual

Hanna Instruments HI 2300 instruction manual

Hanna Instruments

Hanna Instruments HI 2300 instruction manual

Trinity VAF user manual

Trinity

Trinity VAF user manual

Ambient Weather WS-2063 user manual

Ambient Weather

Ambient Weather WS-2063 user manual

Tektronix SDA601 user manual

Tektronix

Tektronix SDA601 user manual

Circutor AR5 instruction manual

Circutor

Circutor AR5 instruction manual

Extech Instruments RH600 quick start guide

Extech Instruments

Extech Instruments RH600 quick start guide

GARANT 380865 1 Operation manual

GARANT

GARANT 380865 1 Operation manual

Tektronix 475 instruction manual

Tektronix

Tektronix 475 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.