PACH & COMPANY AeGIS AFGR9 Assembly instructions

AeGIS AFGR9
Installation and Programming Manual
Pach & Company 941 Calle Negocio Phone: 1-888-678-7224
www.pach-co.com San Clemente, CA 92673 Fax: 949-498-6879
July 28, 2004

TABLE OF CONTENTS
Chapter 1 Getting Started ........................................................................................... 1
1.1 Introduction................................................................................................................ 1
1.2 System Description ................................................................................................... 1
1.3 System Specification ................................................................................................. 1
1.4 System Accessories .................................................................................................. 2
1.5 Unpacking The System ............................................................................................. 2
Chapter 2. Installation ................................................................................................. 3
2.1 Wiegand Interface Connection ........................................................................... 5
2.2 Standalone Unit Connection ............................................................................... 6
2.3 RS-485 Connection ............................................................................................ 7
2.4 RS-232 Backup Database Connection .............................................................. 8
Chapter 3. Set Parameters .......................................................................................... 9
3.1 Power Up the System ........................................................................................ 9
3.2 Date Display Mode ............................................................................................. 10
3.3 Time Display Mode ............................................................................................. 11
3.4 Back Light ........................................................................................................... 11
3.5 Facility Code ....................................................................................................... 12
3.6 Relay Select ........................................................................................................ 13
3.7 Digital Input ......................................................................................................... 13
3.8 Relay 1 Duration ................................................................................................. 14
3.9 Relay 2 Duration ................................................................................................. 15
3.10 ADMIN Code ....................................................................................................... 16
3.11 MAGIC Code ....................................................................................................... 16
Chapter 4. Enrollment .................................................................................................. 18
4.1 Primary Finger Print Enrollment .......................................................................... 18
4.2 Replace the Primary Enrollment .......................................................................... 19
4.3 Secondary Finger Print Enrollment ...................................................................... 20
Chapter 5. Special Enrollment ..................................................................................... 22
5.1 Primary Finger Print Special Enrollment .............................................................. 22
5.2 Replace the Primary Special Enrollment ............................................................. 23
5.3 Secondary Finger Print Special Enrollment ......................................................... 24
Chapter 6. User Dir ........................................................................................................ 25
Chapter 7. Delete User .................................................................................................. 26
Chapter 8. Delete All Users .......................................................................................... 27
Chapter 9. Set Time/Date .............................................................................................. 28
Chapter 10. Install Software ......................................................................................... 29
Chapter 11. Backup the Database ............................................................................... 32
Chapter 12. System’s Operation .................................................................................. 35

LIMITATIONS OF LIABILITY
This manual is subject to change without notice.
Pach & Company is not liable for any errors that might occur from use of this document, nor is any
commitment to update the information herein implied.
Pach & Company does not assume any liability for any damages, which may arise in installation or use of the
AeGIS AFGR9.
Pach & Company does not assume liability for any incompatibility between the AeGIS AFGR9 and user devices.
Pach & Company reserves the right to make changes without prior notice to any products in order to improve
reliability, function or design.
WARRANTY
The AFGR9 comes with TWO (2) YEARS WARRANTY FOR MANUFACTURER’S PARTSAND MANUFACTURING
LABOR .We will include lightning strikes in our two years warranty if our ASP1 surge protector is installed with the systems.
If you use other than Pach and Company ASP1 Surge Protector, you are responsible to claim the damages to the surge
protector manufacturer. The above warranties are subject to the following conditions.
• The products must be properly installed as specified, maintained, used as intended.
• The serial number on the printed circuit board must match the serial number on the cabinet.
• The system's failure is not caused by vandalism, improper instillation, misuse or abuse.
• Physically damaged product is not acceptable for repair or exchange within our warranty.
• The warranty will be void and null if the product has been repaired or modified by unauthorized party
without authorization from the Pach & Company Technical Department.
• If for some reason your system cannot be repaired, Pach and Company will replace it with an
identical product of equal value.
• You must obtain a Return Merchandise Authorization (RMA) number from Pach & Company
Technical Department before you can send back the product to factory for repair.
• You are responsible for all transportation and insurance charges for the products shipped to the Pach
& Company repair center.
• Pach & Company will not reimburse your time and labor cost to install, uninstall or reinstall
hardware/software/firmware for enhancements or bugs fixed or systems failures.
• PACH AND COMPANY WILL NOT COVER THE FIELD LABOR TO INSTALL, REMOVE AND
TROUBLE-SHOOT THE SYSTEM.

CHAPTER 1. GETTING STARTED
1.1 Introduction
Pach & Company thanks and congratulates you on the purchase of your AeGIS AFGR9 Biometric Fingerprints Reader with
26-Bit Wiegand Output.
The manual is designed to guide you through the proper programming and use of the AeGIS AFGR9. It is important for you
to read and follow the manual completely.
The Aegis AFGR9 comes with two years warranty (see warranty on previous page). We will include lightning strikes in our
two years warranty if Pach & Company surge protector (ASP1) is installed with the system.
1.2 System Description
The AeGIS AFGR9 is a Biometric Fingerprint Reader with 26-Bit Wiegand Output and 1000 Template/Access
Code Capacity. The system can be installed as a standalone, Wiegand interface with the AeGIS 9000 Series or
RS-485 using our AWCRM (AeGIS 26-Bit Wiegand Card Reader Module).
1.3 System Specifications
Standard Features
• 500 DPI Optical Finger Print Sensor.
• 1000 Template/Access-Code capacity.
• One 26-Bit wiegand Output.
• Two RS-232 (115200 Bps) for database backup and firmware upgrade.
• 2x16 character Liquid Crystal Display with backlit.
• Local Access keypad entry code.
• Standalone, Wiegand Interface or RS485 application with optional controller module (AWCRM).
• Brushed stainless steel faceplate, surface mount, indoor or outdoor.
Specifications
• Processor 8 bits CMOS, 18,432 MHz
• Real time clock.
• Memory : DATA 128 KB SRAM (volatile) with battery backup Li-Mn 3V CR2450 (3 years life time).
PROGRAM 256 KB Flash.
• Power 12VAC/DC, 12 VAC transformer is supplied.
• Current Consumption: 300 mA idle, 500 mA peak.
• Temperature range32°F to +140°F Relative Humidity 0% to 95% non-condensing.
* Heater Pad (AHP5) is required if the ambient temperature is below 32°F.
• Two Relays 125VAC 500mA, 110VDC 200mA or 24VDC 1.0A.
• Programming port for database download and firmware upgrade.
• Dimension: 5.32” x 8.07’ x 2.76” (WxHxD).
• Approximate shipping weight: 7 Lbs.
Pach and Company Page 1 07/28/04
AFGR9 Chapter 1. Getting Started

1.4 System Accessories
1.5 Unpacking the System
Check the serial number on the printed circuit board and cabinet, they must be matched. If they don’t match
contact, return the product to your distributor or call Pach and Company at 1-888-678-7224. All the items below
come with the system.
• AFGR9 System.
• XMFR (12VAC Power Transformer).
• One-2 pins terminal connector (inside the unit).
• Two- 12pins terminal connector (inside the unit).
• RS-232 cable.
• Set of keys.
Part Number Description
ASP1 AC and Telephone Surge Protector.
AHP5 Heater pad with thermostat.
AWCRM AeGIS 26-Bit Wiegand Card Reader Module.
AKYS AeGIS key sets (2 keys per set).
AFGR9MAN AeGIS AFGR9 manual.
XMFR 12VAC power transformer.
Pach and Company Page 2 07/28/04
AFGR9 Chapter 1. Getting Started

CHAPTER 2. INSTALLATION
A proper installation of the AeGIS system is very essential. Improper installation will void the warranty. The
AFGR9 can be installed as Wiegand Interface with the AeGIS 9000 Series, Standalone unit or RS-485 using
Figure 2.1 Printed Circuit Board
Pach and Company Page 3 07/28/04
AFGR9 Chapter 2. Installation

Pach & Co AWCRM (26-Bit Wiegand Card Reader Module).
Pins Configuration
Pin Number Label on the Board Detail Description
1Earth GND Earth Ground Connection.
2R2COM Relay 2 common.
3R2NC Relay 2 Normally Close.
4R2NO Relay 2 Normally Open.
5R1COM Relay 1 common.
6R1NC Relay 1 Normally Close.
7R1NO Relay 1 Normally Open.
8GND System Ground (Do not
connect to earth ground).
9WGN_D1 Wiegand output data1
(maximum distance 500 ft
using 18 gauge wire).
10 WGN_D0 Wiegand output data 0
(maximum distance 500 ft
using18 gauge wire).
11 GND System Ground (Do not
connect to earth ground).
12 E_DATA External Data (Not used).
13 E_CLK External Clock (Not Used).
14 5V Out 5VDC auxiliary output with
respect to GND(Pin 8,11,15).
15 GND System Ground (Do not
connect to earth ground).
16 DOOR_SW Door Switch (Not used).
17 REX Request to EXIT.
18 D* RS-485 (not used).
19 DRS-485 (not used).
20 GND RS-232 Ground (To Pin 5on
DB9).
21 CTS0 RS-232 Clear to send.
22 RTS0 RS-232 Request to send.
23 RXD0 RS-232 Receive (To Pin 3 on
DB9.
24 TXD0 RS-232 Transmit (To Pin 2 on
DB9.
Pach and Company Page 4 07/28/04
AFGR9 Chapter 2. Installation

2.1 Wiegand Interface Connection
The AeGIS AFGR9 has one Wiegand output to interface with the AeGIS 9000 Series. The maximum distance
between the two units cannot exceed 500 feet using 18 gauge wire. There are four relays available if you use
the Wiegand Interface Connection: Two relays on AFGR9 (see figure 2.3) and two relays on AeGIS 9000
Series (See AeGIS 9000 Series Installation and Programming Manual). See figure 2.2 for wiring diagram.
Figure 2.2 WIEGAND INTERFACE
Pach and Company Page 5 07/28/04
AFGR9 Chapter 2. Installation

2.2 Standalone Unit Connection
The AFGR9 has two on board relay to control two doors at the same time. See figure 2.3.
Figure 2.3 STANDALONE
Pach and Company Page 6 07/28/04
AFGR9 Chapter 2. Installation

2.3 RS-485 Connection
An Optional RS-485 Wiegand Card Reader Module (AWCRM) must be used for this application.
The AWCRM has one built-in relay to control door or gate. You may also use the two built-in relays on the
AFGR9 to control
another door or gate (see figure 2.3)
Figure 2.4 RS-485
Pach and Company Page 7 07/28/04
AFGR9 Chapter 2. Installation

2.4 RS-232 Backup Database Connection
The RS-232 is used for database backup. The RS-232 DB9 is supplied. See figure 2.5 for wiring diagram.
Figure 2.5 RS-232
Pin 20
Pin 23
Pin 24
BLACK
WHITE
GREEN
Pach and Company Page 8 07/28/04
AFGR9 Chapter 2. Installation

CHAPTER 3. SET PARAMETERS
3.1 Turn The System ON
Step 1 Turn the system ON. You will hear continuous beep. You must close the panel or press the tamper
switch to stop the beep.
Step 2 The LCD will show time and date on the first line and Welcome to Pach and Company Access Control
scrolling message on the second line.
Step 3 Adjust the LCD contrast, see figure 2.1 to locate the LCD contrast adjustment. Clockwise to increase
contrast or counter clockwise to decrease.
Step 4 Close the door panel, see figure 3.1. Panel Layout.
Figure 3.1 Panel Layout
Pach and Company Page 9 07/28/04
AFGR9 Chapter 3. Set Parameters

3.2 Date Display Mode
Step 1 Enter the Admin Code 0000, the the display will show
Step 2 Enter the Magic Code (Password) 0000, then press the screen will show
Step 3 Press the screen will show:
Step 4 Press the display will show:
Step 5 Enter the Display Mode Code from the table below then press and
the screen will show
NOTE: To keep the existing Date Display mode press
Step 6 Press to exit from the programming mode or continue programming.
Password:_
ACS-BIO Setup
Set Parameter 1
Date Disp Mode
1 3
Date Disp Mode
1 _
MODE CODE EXAMPLE
DD/MM/YY 003/06/04
DD/MM 103/06
DD Mon 203 July
DDMonYY 303July04
MM/DD/YY 406/03/04
MM/DD 506/03
Mon DD 6June 03
MonDDYY 7June03 04
ACS-BIO Setup
Set Parameter 1
Pach and Company Page 10 07/28/04
AFGR9 Chapter 3. Set Parameters

3.3 Time Display Mode
Step 1 Enter the Admin Code 0000, the the display will show
Step 2 Enter the Magic Code (Password) 0000, then press the screen will show
Step 3 Press then the screen will show
Step 4 Press the screen will show:
Step 5 Enter the Time Mode Code from the table below then press and
Step 6 Press to exit from the programming mode or continue programming.
3.4 Back Light
Step 1 Enter the Admin Code 0000, the the display will show
Step 2 Enter the Magic Code (Password) 0000, then press the screen will show:
Step 3 Press then press twice, the display will show
Password:_
ACS-BIO Setup
Set Parameter 1
Time Disp Mode
2 1
Time Disp Mode
2 _
MODE CODE EXAMPLE
HH:MM 015:00
HH:MM:SS 115:00:00
Password:_
ACS-BIO Setup
Set Parameter 1
Back Light
3 1
Pach and Company Page 11 07/28/04
AFGR9 Chapter 3. Set Parameters

Step 4 Press the screen will show
Step 5 Enter the Back Light Code from the table below then press then
Step 6 Press to exit from the programming mode or continue programming.
3.5 Facility Code
The Wiegand facility code is range from 001-255. The Wiegand facility code must be programmed if
• If the AFGR9 is connected to the AeGIS 9000 Series Wiegand input or
• If the AFGR9 is connected to the AWCRM Wiegand input communicate via RS-485.
Facility Code is not necessary if the AFGR9 is configured as a standalone unit.
Step 1 Enter the Admin Code 0000, the the display will show:
Step 2 Enter the Magic Code (Password) 0000, then press the screen will show
Step 3 Press then press three times, the display will show
Step 4 Press the screen will show
Step 5 Enter the 3-digit Facility Code (001-255) then press then
Step 6 Press to exit from the programming mode or continue programming.
Back Light
3 _
MODE CODE
If the keypad is pressed the LCD back light will be off 0
If the keypad is pressed the LCD back light will be on
in a few seconds. 1
Password:_
ACS-BIO Setup
Set Parameter 1
Facility Code
4 019
Facility Code
4 _
Pach and Company Page 12 07/28/04
AFGR9 Chapter 3. Set Parameters

3.6 Relay Select
Step 1 Enter the Admin Code 0000, the the display will show
Step 2 Enter the Magic Code (Password) 0000, then press the screen will show
Step 3 Press then press four times, the display will show
Step 4 Press the screen will show
Step 5 Press Relay Select Code from the table below and then press then
Step 6 Press to exit from the programming mode or continue programming.
3.7 Digital Input
The REX input can be used for exit switch, postal entry, etc. (see diagram). The REX input can be programmed
to trigger relay 1, relay 2 or both.
Step 1 Enter the Admin Code 0000, the the display will show
Step 2 Enter the Magic Code (Password) 0000, then press the screen will show
Password:_
ACS-BIO Setup
Set Parameter 1
Relay Select
5 0
Relay Select
5 _
MODE CODE
No Relay 0
Relay 1 activated 1
Relay 2 activated 2
Both relay 1 and relay 2 activated 3
Password:_
ACS-BIO Setup
Set Parameter 1
Pach and Company Page 13 07/28/04
AFGR9 Chapter 3. Set Parameters

Step 3 Press then press five times, the display will show
Step 4 Press the screen will show
Step 5 Press Relay Select Code from the table below and then press then
See figure 3.5.1 for Digital Input Wiring Diagram (REX)
Figure 3.5.1 REX Wring Diagram
Step 6 Press to exit from the programming mode or continue programming.
3.8 Relay 1 Duration
Step 1 Enter the Admin Code 0000, the the display will show
Digital Input
6 0
Digital Input
6 _
MODE CODE
Digital Input Disable 0
REX activated 1
Password:_
Pach and Company Page 14 07/28/04
AFGR9 Chapter 3. Set Parameters

Step 2 Enter the Magic Code (Password) 0000, then press the screen will show
Step 3 Press then press six times, the display will show
Step 4 Press the screen will show
Step 5 Enter the time duration in milliseconds then press and then
Step 6 Press to exit from the programming mode or continue programming.
3.9 Relay 2 Duration
Step 1 Enter the Admin Code 0000, the the display will show
Step 2 Enter the Magic Code (Password) 0000, then press the screen will show
Step 3 Press then press seven times, the display will show
Step 4 Press the screen will show
Step 5 Enter the time duration in milliseconds then press and then
Step 6 Press to exit from the programming mode or continue programming.
ACS-BIO Setup
Set Parameter 1
Relay 1 Duration
705000
Relay 1 Duration
7 _
Password:_
ACS-BIO Setup
Set Parameter 1
Relay 2 Duration
805000
Relay 2 Duration
8 _
Pach and Company Page 15 07/28/04
AFGR9 Chapter 3. Set Parameters

3.10 ADMIN Code
You must enter the 4-digit ADMIN code before entering to Magic Code (Password). The default ADMIN code is
0000. You must change your ADMIN code for security purposes.
Step 1 Enter the Admin Code 0000, the the display will show
Step 2 Enter the Magic Code (Password) 0000, then press the screen will show
Step 3 Press then press eight times, the display will show
Step 4 Press the screen will show
Step 5 Enter the new 4-digit ADMIN code then press and then
Step 6 Press to exit from the programming mode or continue programming.
3.11 MAGIC Code
The MAGIC code is also called PASSWORD. The default PASSWORD is 0000. You must change your
PASSWORD code for security purposes. The PASSWORD code is 4-digit long.
Step 1 Enter the Admin Code 0000, the the display will show
Step 2 Enter the Magic Code (Password) 0000, then press the screen will show
Step 3 Press then press nine times, the display will show
Password:_
ACS-BIO Setup
Set Parameter 1
Admin Code
90000
Admin Code
9 _
Password:_
Magic Code
10 0000
ACS-BIO Setup
Set Parameter 1
Pach and Company Page 16 07/28/04
AFGR9 Chapter 3. Set Parameters

Step 4 Press the screen will show
Step 5 Enter the new 4-digit ADMIN code then press and then
Step 6 Press to exit from the programming mode or continue programming.
NOTE: If you forgot the 4-digit ADMIN and MAGIC codes you must reset the system to factory default, see
steps below. Resetting the system will reset the all the parameters to factory default. The system will
keep the finger print template but all names associated with the templates will be deleted.
1. Turn off the system (Unplug the transformer).
2. Press and hold the , then plugin the transformer.
3. On display will appear firmware version.
4. Don't release the in about 5 seconds until the system beep three times.
5. On the display will appear message Initialize Flash.
6. Enter the Password 081745 then press
7. The parameters will be defaulted.
Admin Code
10 _
Pach and Company Page 17 07/28/04
AFGR9 Chapter 3. Set Parameters
Table of contents
Other PACH & COMPANY Control System manuals
Popular Control System manuals by other brands

Siemens
Siemens RHVF12 installation instructions

Mitsubishi Electric
Mitsubishi Electric MELDAS FCU6-DX561 Maintenance manual

ROTOTILT
ROTOTILT ICS Direct Translation of the original instruction

IGM Professional
IGM Professional Odyssey BAYLOAMS20 installation guide

Black Bruin
Black Bruin On-Demand product manual

Mitsubishi Electric
Mitsubishi Electric M800VW Series manual