Panasonic EX-F61 User manual

MJEC-EXF60 No.0045-90V
Thank you very much for purchasing Panasonic products.
Please read this Instruction Manual carefully and thoroughly
for the correct and optimum use of this product. Kindly keep
this manual in a convenient place for quick reference.
This product is a sensor for detecting leak of
fluids.
When this product is used with safety devices,
construct the system such that the device itself
always operates in the safety side.
ە
ە
WARNING
SPECIFICATIONS
1
Incandescent light: 1,000 lx or less at the light-receiving face
Ambient illuminance Infrared LED (non-modulated)
Emitting element Enclosure: PFA
Material 0.1mm2 3-core PFA
cabtyre cable, 3m long 0.1mm2 3-core PFA
cabtyre cable, 5m long 0.1mm2 3-core PFA
cabtyre cable, 3m long 0.1mm2 3-core PFA
cabtyre cable, 5m long
Cable
IP67(IEC)
Protection -10 to +60Υ(No dew condensation or icing allowed) (Note 3, 4), Storage: -20 to +70Υ
Ambient temperature 35 to 85% RH, Storage: 5 to 85% RH
Ambient humidity
50ms or less
Response time Red LED (lights up when leak is detected or the sensor is mounted improperly.)
Abnormality indicator Green LED (lights up when the sensor is mounted properly.)
Normal indicator
ON when normal operation, OFF when leak is detected or the sensor is mounted improperly.
Output operation Incorporated
Short-circuit protection
࣭
࣭
࣭
<NPN output type>
NPN open-collector transister
Maximum sink current: 50mA
Applied voltage: 30V DC or less (between output and 0V)
Residual voltage: 1.0V or less (at 50mA sink current)
0.4V or less (at 16mA sink current)
<PNP output type>
PNP open-collector transister
࣭
࣭
࣭
Maximum source current: 50mA
Applied voltage: 30V DC or less (between output and +V)
Residual voltage: 1.0V or less (at 50mA source current)
0.4V or less (at 16mA source current)
Output
Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. (Note1, 2)
Sensing object
12 to 24V DC s10%ࠉRipple P-P 10% or less
Supply voltage 15mA or less
Current consumption
Type
Model
No.
NPN output type
PNP output type
PFA mounting bracket type (For screw-fixing)
PVC mounting bracket type (For adhesive-fixing)
EX-F61
EX-F61-PN
3m cable length type EX-F61-C5
EX-F61-PN-C5
5m cable length type EX-F62
EX-F62-PN
3m cable length type
Item EX-F62-C5
EX-F62-PN-C5
5m cable length type
60g approx. 80g approx. 60g approx. 80g approx.
Weight PFA mounting bracket: 1 pc. PVC mounting bracket: 1pc.
Accessories
Notes: 1)
2)
3)
4)
Highly viscous liquid may not be stably detected.
The agents mentioned above are examples. Further, PVC mounting bracket may not be used
depending on type or viscosity etc. of the agent. For details, please contact us.
Liquid being detected should be also kept within the rated ambient temperature range.
The specified ambient temperature is only for fixed product.
CAUTIONS
2
ە
ە
ە
ە
ە
ە
ە
ە
ە
ە
ە
This product has been developed / produced for industrial use only.
Avoid using the product in an explosive atmosphere because this
product does not have an explosive-proof protective construction.
Make sure to carry out the wiring in the power supply off condition.
Take care that wrong wiring will damage the sensor.
Verify that the supply voltage variation is within the rating.
Take care that if a voltage exceeding the rated range is applied, or if
an AC power supply is directly connected, the sensor may get burnt
or damaged.
If power is supplied from a commercial switching regulator, ensure that the
frame ground (F.G.) terminal of the power supply is connected to an actual
ground.
Do not use during the initial transient time (50m sec. approx.)
after the power supply is switched on.
In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of this product, connect the frame
ground (F.G.) terminal of the equipment to an actual ground.
Cable extension is possible up to total 50m with 0.3mm2, or more, cable.
However, in order to reduce noise, make the wiring as short as possible.
Do not run the wires together with high-voltage lines or power lines or put
them in the same race way. This can cause malfunction due to induction.
In case a surge is generated in the used power supply, connect a
surge absoeber to the supply.
ە
ە
ە
ە
ە
ە
ە
ە
ە
Be sure to use the exclusive mounting bracket when installing the
sensor to avoid human error, etc. Reliable detection cannot be
guaranteed when this mounting bracket is not used.
Make sure to use an isolation transformer for the DC power supply. If
an auto-transformer (single winding transformer) is used, this product
or the power supply may get damaged.
In case air bubbles are drawn into the sensing part, take care that it may take
some time for sensing to stabilize, or sensing may even become unstable.
When liquid remains on the sensing surface after leak detection, wipe all
liquid from the sensing surface. To avoid scratching the sensing surface
and the enclosed mounting bracket, use a soft cloth.
If there is liquid remained or scratch on the sensing surface or the
exclsive mounting bracket, normal operation cannot be performed.
Since this sensor employs non-modulated infrared LED, take sufficient care against
extraneous light. Do not expose the sensing part directly to the extraneous light.
Avoid dust, dirt, and steam. Further, do not use this product where oil or
grease splashes to the product, or in an environment containing corrosive gas,
etc.
In case this sensor is used where electrostatic charge is present, use a
metal leak pan, which should be connected to an actual ground.
In case of using this product 50℃or more, be sure to fix this product with
a dedicated mounting bracket.
I/O CIRCUIT DIAGRAMS
4
ŪNPN output type
(Brown) +V
(Black) Output
(Blue) 0V
Load
㸩
㸫
12 to 24V DC
s10%
Internal circuit Users' circuit
50mA max.
Sensor circuit
Color code
ŪPNP output type
㸩
㸫
(Black) Output
(Blue) 0V Load
12 to 24V DC
s10%
Internal circuit Users' circuit
50mA max.
(Brown) +V
Color code
Sensor circuit
ەEX-F61š(Sensor with PFA mounting bracket)
ەEX-F62š(Sensor with PVC mounting bracket)
DIMENSIONS (Unit: mm)5
Fixing surface
314
19.25
Abnormality indicator
(red)
Normal indicator
(green)
21.5
26
27
PVC mounting bracket
314
19.25
Abnormality indicator
(red)
Normal indicator
(green)
2-ȭ4.2 4.5
17
PFA mounting bracket
Stainless steel bush
18
27
26
EX-F62š
ە
ە
Please note that if the excess adhesive from the bottom
surface of the exclusive mounting bracket is remained, the
sensing capability may be affected.
Use adhesive for polyvinyl chloride(PVC).
MOUNTING
3
How to fit the sensor body to the exclusive mounting bracket
ە
Align the projections in the sensor body with the notches of
the exclusive mounting bracket and slide till a click is felt.
Projection
Notches
How to remove the sensor body from the exclusive mounting bracket
ە
Pinch the projections of the sensor body and pull the body
upwards.
Never pull the cable, since it may cause a cable break.
Projection
EX-F61š
ەInsert the M4 stud-bolt
(length 10mm or more)
welded on the user's
facilities into the mounting
hole of the PFA mounting
bracket and screw with an
M4 nut (please arrange
separately). The tightening
torque should be 0.98N㺃m or
less.
M4 nut
M4 stud-bolt
(straight type)
1
INTENDED PRODUCTS FOR CE MARKING
6
ە
ە
The models listed under ' SPECIFICATIONS'
come with CE Marking.
As for all other models, please contact our office.
Contact for CE
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
Amplifier Built-in Leak Detection Sensor
EX-F60 Series
INSTRUCTION
MANUAL
http://panasonic.net/id/pidsx/global
© Panasonic Industrial Devices SUNX Co., Ltd. 2014
PRINTED IN JAPAN
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
About our sale network, please visit our website.
Ramco National
800-280-6933 | [email protected]
www.panasonicsensors.com
MJEC-EXF60 No.0045-90V
Thank you very much for purchasing Panasonic products.
Please read this Instruction Manual carefully and thoroughly
for the correct and optimum use of this product. Kindly keep
this manual in a convenient place for quick reference.
This product is a sensor for detecting leak of
fluids.
When this product is used with safety devices,
construct the system such that the device itself
always operates in the safety side.
ە
ە
WARNING
SPECIFICATIONS
1
Incandescent light: 1,000 lx or less at the light-receiving face
Ambient illuminance Infrared LED (non-modulated)
Emitting element Enclosure: PFA
Material 0.1mm2 3-core PFA
cabtyre cable, 3m long 0.1mm2 3-core PFA
cabtyre cable, 5m long 0.1mm2 3-core PFA
cabtyre cable, 3m long 0.1mm2 3-core PFA
cabtyre cable, 5m long
Cable
IP67(IEC)
Protection -10 to +60Υ(No dew condensation or icing allowed) (Note 3, 4), Storage: -20 to +70Υ
Ambient temperature 35 to 85% RH, Storage: 5 to 85% RH
Ambient humidity
50ms or less
Response time Red LED (lights up when leak is detected or the sensor is mounted improperly.)
Abnormality indicator Green LED (lights up when the sensor is mounted properly.)
Normal indicator
ON when normal operation, OFF when leak is detected or the sensor is mounted improperly.
Output operation Incorporated
Short-circuit protection
࣭
࣭
࣭
<NPN output type>
NPN open-collector transister
Maximum sink current: 50mA
Applied voltage: 30V DC or less (between output and 0V)
Residual voltage: 1.0V or less (at 50mA sink current)
0.4V or less (at 16mA sink current)
<PNP output type>
PNP open-collector transister
࣭
࣭
࣭
Maximum source current: 50mA
Applied voltage: 30V DC or less (between output and +V)
Residual voltage: 1.0V or less (at 50mA source current)
0.4V or less (at 16mA source current)
Output
Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. (Note1, 2)
Sensing object
12 to 24V DC s10%ࠉRipple P-P 10% or less
Supply voltage 15mA or less
Current consumption
Type
Model
No.
NPN output type
PNP output type
PFA mounting bracket type (For screw-fixing)
PVC mounting bracket type (For adhesive-fixing)
EX-F61
EX-F61-PN
3m cable length type EX-F61-C5
EX-F61-PN-C5
5m cable length type EX-F62
EX-F62-PN
3m cable length type
Item EX-F62-C5
EX-F62-PN-C5
5m cable length type
60g approx. 80g approx. 60g approx. 80g approx.
Weight PFA mounting bracket: 1 pc. PVC mounting bracket: 1pc.
Accessories
Notes: 1)
2)
3)
4)
Highly viscous liquid may not be stably detected.
The agents mentioned above are examples. Further, PVC mounting bracket may not be used
depending on type or viscosity etc. of the agent. For details, please contact us.
Liquid being detected should be also kept within the rated ambient temperature range.
The specified ambient temperature is only for fixed product.
CAUTIONS
2
ە
ە
ە
ە
ە
ە
ە
ە
ە
ە
ە
This product has been developed / produced for industrial use only.
Avoid using the product in an explosive atmosphere because this
product does not have an explosive-proof protective construction.
Make sure to carry out the wiring in the power supply off condition.
Take care that wrong wiring will damage the sensor.
Verify that the supply voltage variation is within the rating.
Take care that if a voltage exceeding the rated range is applied, or if
an AC power supply is directly connected, the sensor may get burnt
or damaged.
If power is supplied from a commercial switching regulator, ensure that the
frame ground (F.G.) terminal of the power supply is connected to an actual
ground.
Do not use during the initial transient time (50m sec. approx.)
after the power supply is switched on.
In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of this product, connect the frame
ground (F.G.) terminal of the equipment to an actual ground.
Cable extension is possible up to total 50m with 0.3mm2, or more, cable.
However, in order to reduce noise, make the wiring as short as possible.
Do not run the wires together with high-voltage lines or power lines or put
them in the same race way. This can cause malfunction due to induction.
In case a surge is generated in the used power supply, connect a
surge absoeber to the supply.
ە
ە
ە
ە
ە
ە
ە
ە
ە
Be sure to use the exclusive mounting bracket when installing the
sensor to avoid human error, etc. Reliable detection cannot be
guaranteed when this mounting bracket is not used.
Make sure to use an isolation transformer for the DC power supply. If
an auto-transformer (single winding transformer) is used, this product
or the power supply may get damaged.
In case air bubbles are drawn into the sensing part, take care that it may take
some time for sensing to stabilize, or sensing may even become unstable.
When liquid remains on the sensing surface after leak detection, wipe all
liquid from the sensing surface. To avoid scratching the sensing surface
and the enclosed mounting bracket, use a soft cloth.
If there is liquid remained or scratch on the sensing surface or the
exclsive mounting bracket, normal operation cannot be performed.
Since this sensor employs non-modulated infrared LED, take sufficient care against
extraneous light. Do not expose the sensing part directly to the extraneous light.
Avoid dust, dirt, and steam. Further, do not use this product where oil or
grease splashes to the product, or in an environment containing corrosive gas,
etc.
In case this sensor is used where electrostatic charge is present, use a
metal leak pan, which should be connected to an actual ground.
In case of using this product 50℃or more, be sure to fix this product with
a dedicated mounting bracket.
I/O CIRCUIT DIAGRAMS
4
ŪNPN output type
(Brown) +V
(Black) Output
(Blue) 0V
Load
㸩
㸫
12 to 24V DC
s10%
Internal circuit Users' circuit
50mA max.
Sensor circuit
Color code
ŪPNP output type
㸩
㸫
(Black) Output
(Blue) 0V Load
12 to 24V DC
s10%
Internal circuit Users' circuit
50mA max.
(Brown) +V
Color code
Sensor circuit
ەEX-F61š(Sensor with PFA mounting bracket)
ەEX-F62š(Sensor with PVC mounting bracket)
DIMENSIONS (Unit: mm)5
Fixing surface
314
19.25
Abnormality indicator
(red)
Normal indicator
(green)
21.5
26
27
PVC mounting bracket
314
19.25
Abnormality indicator
(red)
Normal indicator
(green)
2-ȭ4.2 4.5
17
PFA mounting bracket
Stainless steel bush
18
27
26
EX-F62š
ە
ە
Please note that if the excess adhesive from the bottom
surface of the exclusive mounting bracket is remained, the
sensing capability may be affected.
Use adhesive for polyvinyl chloride(PVC).
MOUNTING
3
How to fit the sensor body to the exclusive mounting bracket
ە
Align the projections in the sensor body with the notches of
the exclusive mounting bracket and slide till a click is felt.
Projection
Notches
How to remove the sensor body from the exclusive mounting bracket
ە
Pinch the projections of the sensor body and pull the body
upwards.
Never pull the cable, since it may cause a cable break.
Projection
EX-F61š
ەInsert the M4 stud-bolt
(length 10mm or more)
welded on the user's
facilities into the mounting
hole of the PFA mounting
bracket and screw with an
M4 nut (please arrange
separately). The tightening
torque should be 0.98N㺃m or
less.
M4 nut
M4 stud-bolt
(straight type)
1
INTENDED PRODUCTS FOR CE MARKING
6
ە
ە
The models listed under ' SPECIFICATIONS'
come with CE Marking.
As for all other models, please contact our office.
Contact for CE
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
Amplifier Built-in Leak Detection Sensor
EX-F60 Series
INSTRUCTION
MANUAL
http://panasonic.net/id/pidsx/global
© Panasonic Industrial Devices SUNX Co., Ltd. 2014
PRINTED IN JAPAN
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
About our sale network, please visit our website.
Ramco National
800-280-6933 | [email protected]
www.panasonicsensors.com
SPECIFICATIONS
1
Notes: 1) Highly viscous liquid may not be stably detected.
2) Fluorinert TM is the worldwide trademark of 3M.
3) Liquid being detected should be also kept within the rated ambient temperature range.
Type SUS mounting bracket type PVC mounting bracket type
2m cable length type 5m cable length type 2m cable length type 5m cable length type
Model
NPN output
EX-F71 EX-F71-C5 EX-F72 EX-F72-C5
Item
No.
PNP output
EX-F71-PN EX-F71-PN-C5 EX-F72-PN EX-F72-PN-C5
Sensing object Water, Fluorinert TM (Note 1) (Note 2)
Supply voltage 12 to 24V DC ± 10% Ripple P-P 10% or less
Current consumption 10mA or less (PNP output type: 15mAor less)
Output
<NPN output type>
NPN open-collector transistor
Maximum sink current: 50mA
Applied voltage: 30V DC or less (between output and 0V)
Residual voltage: 1.0V or less (at 50mAsink current)
0.4V or less (at 16mA sink current)
<PNP output type>
PNP open-collector transistor
Maximum source current: 50mA
Applied voltage: 30V DC or less (between output and +V)
Residual voltage: 1.0V or less (at 50mA source current)
0.4V or less (at 16mA source current)
Output operation ON when normal operation, OFF when leak is detected or the sensor is mounted improperly.
Short-circuit protection
Incorporated
Response time 50ms or less
Abnormal indicator Red LED (lights up when leak is detected or the sensor is mounted improperly.)
Normal indicator Green LED (lights up when the sensor is mounted properly.)
Protection IP67 (IEC)
Ambient temperature –10 to +60°C (No dew condensation or icing allowed) (Note 3), Storage: –20 to +70°C
Ambient humidity 35 to 85% RH, Storage: 35 to 85% RH
Ambient illuminance Incandescent light: 1,000Ɛx or less at the light-receiving face
Emitting element Infrared LED (non-modulated)
Material Enclosure: Polypropylene
Cable 0.1mm23-core PVC
cabtyre cable, 2m long 0.1mm23-core PVC
cabtyre cable, 5m long 0.1mm23-core PVC
cabtyre cable, 2m long 0.1mm23-core PVC
cabtyre cable, 5m long
Weight Approx. 25g Approx. 55g Approx. 25g Approx. 55g
Accessories SUS mounting bracket: 1 pc.
PVC mounting bracket: 1 pc. each for two-point-¿xing and adhesive-¿xing
CAUTIONS
2ƔThis product has been developed / produced for
industrial use only.
ƔAvoid using the product in an explosive
atmosphere because this product does not have
an explosive-proof protective construction.
ƔMake sure that the power supply is off while wiring.
ƔTake care that wrong wiring will damage the sensor.
ƔVerify that the supply voltage variation is within
the rating.
Take care that if a voltage exceeding the rated
range is applied, or if anAC power supply is directly
connected, the sensor may get burnt or damaged.
ƔIf power is supplied from a commercial switching
regulator, ensure that the frame ground (F.G.)
terminal of the power supply is connected to an
actual ground.
ƔDo not use during the initial transient time (approx.
50m sec. ) after the power supply is switched on.
ƔIn case noise generating equipment (switching
regulator, inverter motor, etc.) is used in the vicin-
ity of this product, connect the frame ground (F.G.)
terminal of the equipment to an actual ground.
ƔCable extension is possible up to total 50m with
0.3mm2, or more, cable. However, in order to re-
duce noise, make the wiring as short as possible.
ƔDo not run the wires together with high-voltage lines
or power lines or put them in the same raceway.
This can cause malfunction due to induction.
ƔIn case a surge is generated in the used power sup-
ply, connect a surge absorber to the supply and ab-
sorb the surge.
Ɣ%e sure to use the exclusive mounting bracket when installing
the sensor to avoid human error, etc. Reliable detection can-
not be guaranteed when this mounting bracket is not used.
MOUNTING
3
(;)Ƒ
ƔInsert the M4 stud-bolt (length 10mm or more)
welded on the user’s facilities into the mounting
hole of the SUS mounting bracket and screw with
an M4 nut (please arrange separately).
The tightening torque should be 0.98N·m or less.
M4 nut <Mounting dimensions (Unit: mm)>
M4 stud-bolt
(straight type)
26.516
13
5.5
(;)Ƒ
,QFDVHRIXVLQJWKHWZRSRLQW¿xing PVC mounting bracket>
ƔInsert M4 stud-bolts (length 10mm or more) welded
on the user’s facilities into the mounting holes of
the two-point-fixing mounting bracket and screw
with M4 nuts (please arrange separately).
The tightening torque should be 0.49N·m or less.
M4 nuts
M4 stud-bolts
(straight type)
<Mounting dimensions (Unit: mm)>
26.5
34.7
13
9
20.7
How to ¿t the sensor body to the exclusive mounting bracket
<In case of using the PVC mounting bracket for adhesive ¿xing>
ƔUse adhesive to stick fast the mounting bracket
on the mounting surface. Please note that if the
adhesive sticks out from the bottom surface of
the mounting bracket or is 0.5mm, or more thick,
the sensor body cannot be ¿tted to the mounting
bracket.
ƔMatch the notch in the sensor body with the
projection of the exclusive mounting bracket and
slide till a click is felt.
Notch
Projection
I/O CIRCUIT DIAGRAMS
4
ƔNPN output type
ƔPNP output type
Load
Internal circuit Users’ circuit
(%rown) +V
(%lue) 0V
50mA max.
(%lack) Output
12 to 24V DC
±10%
+
-
Color code
Main circuit
Load
Internal circuit Users’ circuit
(%rown) +V
(%lue) 0V
50mA max.
(%lack) Output
12 to 24V DC
±10%
+
-
Color code
Main circuit
INTENDED PRODUCTS FOR CE MARKING
5
ƔThe models listed under “ SPECIFICA-
TIONS” come with CE Marking.
As for all other models, please contact our
of¿ce.
ƔTake care not to use the SUS mounting bracket for
EX-F72Ƒor the PVC mounting bracket for EX-F71Ƒ
mistakenly, since normal detection cannot be performed.
ƔMake sure to use an isolation transformer for the
DC power supply. If an auto-transformer (single
winding transformer) is used, this product or the
power supply may get damaged.
ƔIn case air bubbles are drawn into the sensing part,
take care that it may take some time for sensing to
stabilize, or sensing may even become unstable.
ƔWhen conducting maintenance after operation,
wipe all liquid from the sensor and mounting
bracket with a soft cloth.
ƔIf there is liquid remained or scratch on the sensing
surface or the exclusive mounting bracket, normal
operation cannot be performed.
ƔSince this sensor employs non-modulated infrared
LED, take suf¿cient care against extraneous light.
Do not expose the sensing part directly to the
extraneous light.
ƔAvoid dust, dirt, and steam. Further, do not use this
product in an environment containing organic solvents.
ƔTake care that the product does not come in
contact with oil, grease or organic solvents, such
as, thinner, etc.
ƔIn case this sensor is used where electrostatic
charge is present, use a metal leak pan, which
should be connected to an actual ground.
Thank you very much for purchasing Panasonic products.
Please read this Instruction Manual carefully and thor-
oughly for the correct and optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.
ƔNever use this product as a sensing device for
personnel protection.
ƔI
n case of using sensing devices for personnel protec-
tion, use products which meet laws and standards, such
as OSHA, ANSI or IEC etc., for personnel protection ap-
plicable in each region or country.
INSTRUCTION
MANUAL
Ampli¿er %uilt-in Leak Detection Sensor
EX-F70 Series
MJEC-EXF71 No.0044-45V
http://panasonic.net/id/pidsx/global
Overseas Sales Division (Head Of¿ce)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
About our sale network, please visit our website.
© Panasonic Industrial Devices SUNX Co., Ltd. 2014
PRINTED IN JAPAN
ƔContact for CE
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
Ramco National
800-280-6933 | [email protected]
www.panasonicsensors.com
SPECIFICATIONS
1
Notes: 1) Highly viscous liquid may not be stably detected.
2) Fluorinert TM is the worldwide trademark of 3M.
3) Liquid being detected should be also kept within the rated ambient temperature range.
Type SUS mounting bracket type PVC mounting bracket type
2m cable length type 5m cable length type 2m cable length type 5m cable length type
Model
NPN output
EX-F71 EX-F71-C5 EX-F72 EX-F72-C5
Item
No.
PNP output
EX-F71-PN EX-F71-PN-C5 EX-F72-PN EX-F72-PN-C5
Sensing object Water, Fluorinert TM (Note 1) (Note 2)
Supply voltage 12 to 24V DC ± 10% Ripple P-P 10% or less
Current consumption 10mA or less (PNP output type: 15mAor less)
Output
<NPN output type>
NPN open-collector transistor
Maximum sink current: 50mA
Applied voltage: 30V DC or less (between output and 0V)
Residual voltage: 1.0V or less (at 50mAsink current)
0.4V or less (at 16mA sink current)
<PNP output type>
PNP open-collector transistor
Maximum source current: 50mA
Applied voltage: 30V DC or less (between output and +V)
Residual voltage: 1.0V or less (at 50mA source current)
0.4V or less (at 16mA source current)
Output operation ON when normal operation, OFF when leak is detected or the sensor is mounted improperly.
Short-circuit protection
Incorporated
Response time 50ms or less
Abnormal indicator Red LED (lights up when leak is detected or the sensor is mounted improperly.)
Normal indicator Green LED (lights up when the sensor is mounted properly.)
Protection IP67 (IEC)
Ambient temperature –10 to +60°C (No dew condensation or icing allowed) (Note 3), Storage: –20 to +70°C
Ambient humidity 35 to 85% RH, Storage: 35 to 85% RH
Ambient illuminance Incandescent light: 1,000Ɛx or less at the light-receiving face
Emitting element Infrared LED (non-modulated)
Material Enclosure: Polypropylene
Cable 0.1mm23-core PVC
cabtyre cable, 2m long 0.1mm23-core PVC
cabtyre cable, 5m long 0.1mm23-core PVC
cabtyre cable, 2m long 0.1mm23-core PVC
cabtyre cable, 5m long
Weight Approx. 25g Approx. 55g Approx. 25g Approx. 55g
Accessories SUS mounting bracket: 1 pc.
PVC mounting bracket: 1 pc. each for two-point-¿xing and adhesive-¿xing
CAUTIONS
2ƔThis product has been developed / produced for
industrial use only.
ƔAvoid using the product in an explosive
atmosphere because this product does not have
an explosive-proof protective construction.
ƔMake sure that the power supply is off while wiring.
ƔTake care that wrong wiring will damage the sensor.
ƔVerify that the supply voltage variation is within
the rating.
Take care that if a voltage exceeding the rated
range is applied, or if anAC power supply is directly
connected, the sensor may get burnt or damaged.
ƔIf power is supplied from a commercial switching
regulator, ensure that the frame ground (F.G.)
terminal of the power supply is connected to an
actual ground.
ƔDo not use during the initial transient time (approx.
50m sec. ) after the power supply is switched on.
ƔIn case noise generating equipment (switching
regulator, inverter motor, etc.) is used in the vicin-
ity of this product, connect the frame ground (F.G.)
terminal of the equipment to an actual ground.
ƔCable extension is possible up to total 50m with
0.3mm2, or more, cable. However, in order to re-
duce noise, make the wiring as short as possible.
ƔDo not run the wires together with high-voltage lines
or power lines or put them in the same raceway.
This can cause malfunction due to induction.
ƔIn case a surge is generated in the used power sup-
ply, connect a surge absorber to the supply and ab-
sorb the surge.
Ɣ%e sure to use the exclusive mounting bracket when installing
the sensor to avoid human error, etc. Reliable detection can-
not be guaranteed when this mounting bracket is not used.
MOUNTING
3
(;)Ƒ
ƔInsert the M4 stud-bolt (length 10mm or more)
welded on the user’s facilities into the mounting
hole of the SUS mounting bracket and screw with
an M4 nut (please arrange separately).
The tightening torque should be 0.98N·m or less.
M4 nut <Mounting dimensions (Unit: mm)>
M4 stud-bolt
(straight type)
26.516
13
5.5
(;)Ƒ
,QFDVHRIXVLQJWKHWZRSRLQW¿xing PVC mounting bracket>
ƔInsert M4 stud-bolts (length 10mm or more) welded
on the user’s facilities into the mounting holes of
the two-point-fixing mounting bracket and screw
with M4 nuts (please arrange separately).
The tightening torque should be 0.49N·m or less.
M4 nuts
M4 stud-bolts
(straight type)
<Mounting dimensions (Unit: mm)>
26.5
34.7
13
9
20.7
How to ¿t the sensor body to the exclusive mounting bracket
<In case of using the PVC mounting bracket for adhesive ¿xing>
ƔUse adhesive to stick fast the mounting bracket
on the mounting surface. Please note that if the
adhesive sticks out from the bottom surface of
the mounting bracket or is 0.5mm, or more thick,
the sensor body cannot be ¿tted to the mounting
bracket.
ƔMatch the notch in the sensor body with the
projection of the exclusive mounting bracket and
slide till a click is felt.
Notch
Projection
I/O CIRCUIT DIAGRAMS
4
ƔNPN output type
ƔPNP output type
Load
Internal circuit Users’ circuit
(%rown) +V
(%lue) 0V
50mA max.
(%lack) Output
12 to 24V DC
±10%
+
-
Color code
Main circuit
Load
Internal circuit Users’ circuit
(%rown) +V
(%lue) 0V
50mA max.
(%lack) Output
12 to 24V DC
±10%
+
-
Color code
Main circuit
INTENDED PRODUCTS FOR CE MARKING
5ƔThe models listed under “ SPECIFICA-
TIONS” come with CE Marking.
As for all other models, please contact our
of¿ce.
ƔTake care not to use the SUS mounting bracket for
EX-F72Ƒor the PVC mounting bracket for EX-F71Ƒ
mistakenly, since normal detection cannot be performed.
ƔMake sure to use an isolation transformer for the
DC power supply. If an auto-transformer (single
winding transformer) is used, this product or the
power supply may get damaged.
ƔIn case air bubbles are drawn into the sensing part,
take care that it may take some time for sensing to
stabilize, or sensing may even become unstable.
ƔWhen conducting maintenance after operation,
wipe all liquid from the sensor and mounting
bracket with a soft cloth.
ƔIf there is liquid remained or scratch on the sensing
surface or the exclusive mounting bracket, normal
operation cannot be performed.
ƔSince this sensor employs non-modulated infrared
LED, take suf¿cient care against extraneous light.
Do not expose the sensing part directly to the
extraneous light.
ƔAvoid dust, dirt, and steam. Further, do not use this
product in an environment containing organic solvents.
ƔTake care that the product does not come in
contact with oil, grease or organic solvents, such
as, thinner, etc.
ƔIn case this sensor is used where electrostatic
charge is present, use a metal leak pan, which
should be connected to an actual ground.
Thank you very much for purchasing Panasonic products.
Please read this Instruction Manual carefully and thor-
oughly for the correct and optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.
ƔNever use this product as a sensing device for
personnel protection.
ƔI
n case of using sensing devices for personnel protec-
tion, use products which meet laws and standards, such
as OSHA, ANSI or IEC etc., for personnel protection ap-
plicable in each region or country.
INSTRUCTION
MANUAL
Ampli¿er %uilt-in Leak Detection Sensor
EX-F70 Series
MJEC-EXF71 No.0044-45V
http://panasonic.net/id/pidsx/global
Overseas Sales Division (Head Of¿ce)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
About our sale network, please visit our website.
© Panasonic Industrial Devices SUNX Co., Ltd. 2014
PRINTED IN JAPAN
ƔContact for CE
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
Ramco National
800-280-6933 | [email protected]
www.panasonicsensors.com

This manual suits for next models

8

Other Panasonic Accessories manuals

Panasonic HG-F1 Series User manual

Panasonic

Panasonic HG-F1 Series User manual

Panasonic KX-HNS103EX User manual

Panasonic

Panasonic KX-HNS103EX User manual

Panasonic EKL3106 User manual

Panasonic

Panasonic EKL3106 User manual

Panasonic MA24F41 User manual

Panasonic

Panasonic MA24F41 User manual

Panasonic PAW-DEWPOINTSENSOR User manual

Panasonic

Panasonic PAW-DEWPOINTSENSOR User manual

Panasonic GP-X SERIES User manual

Panasonic

Panasonic GP-X SERIES User manual

Panasonic HL-C211F-MK User manual

Panasonic

Panasonic HL-C211F-MK User manual

Panasonic MA3X788 (MA788) User manual

Panasonic

Panasonic MA3X788 (MA788) User manual

Panasonic WV-TW310L User manual

Panasonic

Panasonic WV-TW310L User manual

Panasonic MA2Z7850G User manual

Panasonic

Panasonic MA2Z7850G User manual

Panasonic HG-C1000L Series User manual

Panasonic

Panasonic HG-C1000L Series User manual

Panasonic MA3Z7920G User manual

Panasonic

Panasonic MA3Z7920G User manual

Panasonic WX-LA20 User manual

Panasonic

Panasonic WX-LA20 User manual

Panasonic MA3X701 User manual

Panasonic

Panasonic MA3X701 User manual

Panasonic Touch Pen Installation and operating instructions

Panasonic

Panasonic Touch Pen Installation and operating instructions

Panasonic MA3X157A User manual

Panasonic

Panasonic MA3X157A User manual

Panasonic EX Series User manual

Panasonic

Panasonic EX Series User manual

Panasonic MA3D755 (MA7D55) User manual

Panasonic

Panasonic MA3D755 (MA7D55) User manual

Panasonic MA2Z748 User manual

Panasonic

Panasonic MA2Z748 User manual

Panasonic MAZWxxxH Series User manual

Panasonic

Panasonic MAZWxxxH Series User manual

Panasonic MA3SE01 User manual

Panasonic

Panasonic MA3SE01 User manual

Panasonic WX-LA20 User manual

Panasonic

Panasonic WX-LA20 User manual

Panasonic MA3S1330G User manual

Panasonic

Panasonic MA3S1330G User manual

Panasonic MA3S781DG User manual

Panasonic

Panasonic MA3S781DG User manual

Popular Accessories manuals by other brands

Quincy lab 140AE-1 operating manual

Quincy lab

Quincy lab 140AE-1 operating manual

HomePro ZIR000 user manual

HomePro

HomePro ZIR000 user manual

DOL 20SCR Technical user guide

DOL

DOL 20SCR Technical user guide

RAB Smart Task installation manual

RAB

RAB Smart Task installation manual

Kemppi KMS 300 quick guide

Kemppi

Kemppi KMS 300 quick guide

Stearns 57,500 Series Installation and service instructions

Stearns

Stearns 57,500 Series Installation and service instructions

iGuzzini TWILIGHT COPENAGHEN manual

iGuzzini

iGuzzini TWILIGHT COPENAGHEN manual

Adelaide Annexe & Canvas Avan Deluxe installation guide

Adelaide Annexe & Canvas

Adelaide Annexe & Canvas Avan Deluxe installation guide

OHAUS 5000 instruction manual

OHAUS

OHAUS 5000 instruction manual

HOME8 WLS1300 quick start guide

HOME8

HOME8 WLS1300 quick start guide

MAXBOTIX MaxSonar quick start guide

MAXBOTIX

MAXBOTIX MaxSonar quick start guide

ioSmart iSmart56 Installation and user guide

ioSmart

ioSmart iSmart56 Installation and user guide

Focusrite Scarlett 18i8 user guide

Focusrite

Focusrite Scarlett 18i8 user guide

Velleman ED38105 user manual

Velleman

Velleman ED38105 user manual

JumpSport SkyBounce user manual

JumpSport

JumpSport SkyBounce user manual

Prima-Temp PRIYA Instructions for use

Prima-Temp

Prima-Temp PRIYA Instructions for use

Tefcold BC85I-BC85I W user manual

Tefcold

Tefcold BC85I-BC85I W user manual

Vaisala WMS302 user guide

Vaisala

Vaisala WMS302 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.