Switching Diodes
1
Publication date: March 2004 SKF00051BED
Note) *1: Value for single diode
*2: t =1 s
MA6X121 (MA121)
Silicon epitaxial planar type
For switching circuit
■Features
•Three isolated elements contained in one package, allowing high-
density mounting
•Short reverse recovery time trr
•Small terminal capacitance Ct
■Absolute Maximum Ratings Ta=25°C
Unit: mm
Parameter Symbol Rating Unit
Reverse voltage VR80 V
Maximum peak reverse voltage VRM 80 V
Forward current *1IF100 mA
Peak forward current *1IFM 225 mA
Non-repetitive peak forward IFSM 500 mA
surge current
*1, 2
Junction temperature Tj150 °C
Storage temperature Tstg −55 to +150 °C
Parameter Symbol Conditions Min Typ Max Unit
Forward voltage VFIF=100 mA 1.2 V
Reverse voltage VRIR=100 µA80V
Reverse current IRVR=75 V 100 nA
Terminal capacitance CtVR=0 V, f =1 MHz 2 pF
Reverse recovery time *trr IF=10 mA, VR=6 V 3 ns
Irr =0.1 IR , RL=100 Ω
■Electrical Characteristics Ta=25°C ±3°C
Marking Symbol: M2D
1: Cathode 1
2: Cathode 2
3: Cathode 3
4: Anode 3
5: Anode 2
6: Anode 1
EIAJ: SC-74 Mini6-G1 Package
654
123
Bias Application Unit (N-50BU)
90%
Pulse Generator
(PG-10N)
Rs= 50 Ω
Wave Form Analyzer
(SAS-8130)
Ri= 50 Ω
tp= 2 µs
tr= 0.35 ns
δ = 0.05
IF= 10 mA
VR= 6 V
RL= 100 Ω
10%
Input Pulse Output Pulse
Irr = 0.1 IR
trtp
trr
VR
IF
t
t
A
2.90
1.9±0.1 0.16+0.10
–0.06
2.8+0.2
–0.3
1.1+0.3
–0.1
1.1
0 to 0.1 +0.2
–0.1 1.50
(0.65)
0.4±0.2
+0.25
–0.05
(0.95)
0.30+0.10
–0.05
0.50+0.10
–0.05
(0.95)
654
132
+0.20
–0.05
5˚
10˚
Internal Connection
Note) 1. Measuring methods are based on JAPANESE INDUSTRIAL STANDARD JIS C 7031 measuring methods for diodes.
2. Absolute frequency of input and output is 100 MHz.
3. *: trr measurement circuit
Note) The part number in the parenthesis shows conventional part number.
This product complies with the RoHS Directive (EU 2002/95/EC).
2
MA6X121
SKF00051BED
10 −2
0 0.2 0.4 0.6 0.8 1.0 1.2
10 −1
1
10
102
103
Forward voltage VF(V)
Forward current IF(mA)
Ta= 150°C
100°C
25°C
−20°C
10 −3
0 20 40 60 80 100 120
10 −2
10 −1
1
10
102
Reverse voltage VR(V)
Reverse current IR(µA)
Ta= 150°C
100°C
25°C
0
0.4
0.8
1.2
1.6
−40 0 40 80 120 160 200
Ambient temperature T
a
(°C)
Forward voltage V
F
(V)
I
F
= 100 mA
10 mA
3 mA
10 −3
−40 0 40 80 120 160 200
10 −2
10 −1
1
10
102
Ambient temperature Ta(°C)
Reverse current IR(µA)
35 V
1 V
VR= 75 V
0
0.4
0.8
1.2
1.6
0 20 40 60 80 100 120
Reverse voltage V
R
(V)
Terminal capacitance C
t
(pF)
f = 1 MHz
T
a
= 25°C
10 −1
1
10
102
103
10110 −1
Pulse width tW(ms)
Forward surge current IF(surge) (A)
tW
Ta= 25°C
Non repetitive
IF(surge)
IFVFIRVRVFTa
IRTaCtVRIF(surge) tW
This product complies with the RoHS Directive (EU 2002/95/EC).
Request for your special attention and precautions in using the technical information and
semiconductors described in this book
(1)If any of the products or technical information described in this book is to be exported or provided to non-residents, the laws and
regulations of the exporting country, especially, those with regard to security export control, must be observed.
(2)The technical information described in this book is intended only to show the main characteristics and application circuit examples
of the products, and no license is granted under any intellectual property right or other right owned by our company or any other
company. Therefore, no responsibility is assumed by our company as to the infringement upon any such right owned by any other
company which may arise as a result of the use of technical information described in this book.
(3)The products described in this book are intended to be used for standard applications or general electronic equipment (such as office
equipment, communications equipment, measuring instruments and household appliances).
Consult our sales staff in advance for information on the following applications:
–Special applications (such as for airplanes, aerospace, automobiles, traffic control equipment, combustion equipment, life support
systems and safety devices) in which exceptional quality and reliability are required, or if the failure or malfunction of the prod-
ucts may directly jeopardize life or harm the human body.
–Any applications other than the standard applications intended.
(4)The products and product specifications described in this book are subject to change without notice for modification and/or im-
provement. At the final stage of your design, purchasing, or use of the products, therefore, ask for the most up-to-date Product
Standards in advance to make sure that the latest specifications satisfy your requirements.
(5)When designing your equipment, comply with the range of absolute maximum rating and the guaranteed operating conditions
(operating power supply voltage and operating environment etc.). Especially, please be careful not to exceed the range of absolute
maximum rating on the transient state, such as power-on, power-off and mode-switching. Otherwise, we will not be liable for any
defect which may arise later in your equipment.
 Even when the products are used within the guaranteed values, take into the consideration of incidence of break down and failure
mode, possible to occur to semiconductor products. Measures on the systems such as redundant design, arresting the spread of fire
or preventing glitch are recommended in order to prevent physical injury, fire, social damages, for example, by using the products.
(6)Comply with the instructions for use in order to prevent breakdown and characteristics change due to external factors (ESD, EOS,
thermal stress and mechanical stress) at the time of handling, mounting or at customer's process. When using products for which
damp-proof packing is required, satisfy the conditions, such as shelf life and the elapsed time since first opening the packages.
(7)This book may be not reprinted or reproduced whether wholly or partially, without the prior written permission of Matsushita
Electric Industrial Co., Ltd.

This manual suits for next models

1

Other Panasonic Accessories manuals

Panasonic MA3D652 User manual

Panasonic

Panasonic MA3D652 User manual

Panasonic UE-608050 User manual

Panasonic

Panasonic UE-608050 User manual

Panasonic KX-HNS107C User manual

Panasonic

Panasonic KX-HNS107C User manual

Panasonic WX-LA20 User manual

Panasonic

Panasonic WX-LA20 User manual

Panasonic SP Series Guide

Panasonic

Panasonic SP Series Guide

Panasonic HG-T1010 User manual

Panasonic

Panasonic HG-T1010 User manual

Panasonic MQ-W3A-DC12-24VEM User manual

Panasonic

Panasonic MQ-W3A-DC12-24VEM User manual

Panasonic MA26111 User manual

Panasonic

Panasonic MA26111 User manual

Panasonic FM-200 Series User manual

Panasonic

Panasonic FM-200 Series User manual

Panasonic MA3X748 (MA748) User manual

Panasonic

Panasonic MA3X748 (MA748) User manual

Panasonic MA3X720 (MA720) User manual

Panasonic

Panasonic MA3X720 (MA720) User manual

Panasonic EF-S1HS User manual

Panasonic

Panasonic EF-S1HS User manual

Panasonic MCO-170AICUVH Series User manual

Panasonic

Panasonic MCO-170AICUVH Series User manual

Panasonic TYTP10E User manual

Panasonic

Panasonic TYTP10E User manual

Panasonic MA3S132D User manual

Panasonic

Panasonic MA3S132D User manual

Panasonic MA24F41 User manual

Panasonic

Panasonic MA24F41 User manual

Panasonic DP-100 series User manual

Panasonic

Panasonic DP-100 series User manual

Panasonic HL-C21C Series User manual

Panasonic

Panasonic HL-C21C Series User manual

Panasonic WX-LA20 User manual

Panasonic

Panasonic WX-LA20 User manual

Panasonic MALS180X User manual

Panasonic

Panasonic MALS180X User manual

Panasonic MA26P02 User manual

Panasonic

Panasonic MA26P02 User manual

Panasonic EX-F61 User manual

Panasonic

Panasonic EX-F61 User manual

Panasonic KX-TGP700 Service manual

Panasonic

Panasonic KX-TGP700 Service manual

Panasonic MA3X704 User manual

Panasonic

Panasonic MA3X704 User manual

Popular Accessories manuals by other brands

APAR AR431 user manual

APAR

APAR AR431 user manual

Arkon MAGB1 Installation & user guide

Arkon

Arkon MAGB1 Installation & user guide

Eagle EI-250 Installation & operation manual

Eagle

Eagle EI-250 Installation & operation manual

Techly I-BELL-RING04 user manual

Techly

Techly I-BELL-RING04 user manual

Fiamma F45s Series Installation and use instructions

Fiamma

Fiamma F45s Series Installation and use instructions

Hudora 75050 Instructions for use

Hudora

Hudora 75050 Instructions for use

CONVEY-ALL 1640 Operator's manual

CONVEY-ALL

CONVEY-ALL 1640 Operator's manual

Tascam US-800 owner's manual

Tascam

Tascam US-800 owner's manual

Broadley James SingleSense SU600 Operation manual

Broadley James

Broadley James SingleSense SU600 Operation manual

Popp Ei600ZW quick start

Popp

Popp Ei600ZW quick start

PCB Piezotronics 117B118 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 117B118 Installation and operating manual

Elvaco CMa20 quick start guide

Elvaco

Elvaco CMa20 quick start guide

Clas Ohlson LR4 manual

Clas Ohlson

Clas Ohlson LR4 manual

Simrad PI BOTTOM CONTACT - DATASHEET REV A datasheet

Simrad

Simrad PI BOTTOM CONTACT - DATASHEET REV A datasheet

Ecobee SmartSensor EBDWC01 user manual

Ecobee

Ecobee SmartSensor EBDWC01 user manual

FAE 24761 Assembly instructions

FAE

FAE 24761 Assembly instructions

Onix T624W100DA2b instruction manual

Onix

Onix T624W100DA2b instruction manual

Wello Wello Installation guides

Wello

Wello Wello Installation guides

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.