– 3 –
MAC9512086C2
CS-A181KR
Indoor Unit
Functions
Power Switch OFF / ON
POWER IAuto Restart Control
• Operation is restarted after power failure
at previous setting mode.
Anti-Freezing Control
• Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Sleep Mode Auto Control
• Indoor Fan operates at Super Low fan
speed.
• Operation stops after 8 hours.
Indoor Fan Speed Control
• High, Medium and Low.
• Automatic Fan Speed Mode
– Heating : Fan speed varies from Me
SLo in accordance with indoor
heat exchanger.
– Cooling : Fan rotates at Hi and Me
speed. Deodorizing control is
available.
– Soft Dry : Fan rotates at SLo speed.
Deodorizing control is
available.
Hot-Start Control
• Automatic air swing and manual adjusted
by remote control for vertical airflow.
• Manually adjusted by hand for horizontal
airflow.
Airflow Direction Control
• The indoor fan stops until the indoor heat
exchanger temperature over 30°C.
• The indoor fan operates at SLo and Lo–
when indoor heat exchanger temperature
reaches 30°C ~ 42°C.
• Hot start is completed when indoor heat
exchanger reaches 42°C.
Auto Operation Switch
• Used when the remote control cannot be
used.
AUTO
OFF / ON
Remote Control Signal Receiving
Sound Control
• It can be controlled by pressing Auto
Operation Switch for 10 seconds.
Operation Test Running / Pump
Down Switch
TEST RUN
OFF / ON
• Used when test running or servicing.
Operation Indication Lamps (LED)
•POWER (Red)...... Lights up in operation,
blinks in Automatic
Operation Mode judging
and Hot Start operation.
•SLEEP (Orange)..... Lights up in Sleep
Mode Operation.
•TIMER (Orange)..... Lights up in Timer
Setting.
Operation Mode
• Heating, Cooling, Soft Dry, and Automatic
Mode.
Time Delay Safety Control
• Restarting is inhibited for appro. 3 minutes.
7 Minutes Time Save Control
• Cooling Operation only.
➝
Untitled-1 6/10/00, 9:27 AM3