EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Panasonic
  6. •
  7. Air Conditioner
  8. •
  9. Panasonic FV-07VBA1 User manual

Panasonic FV-07VBA1 User manual

This manual suits for next models

1

Other Panasonic Air Conditioner manuals

Panasonic CS-XE7MKEW User manual

Panasonic

Panasonic CS-XE7MKEW User manual

Panasonic U-140PZ2R5 User manual

Panasonic

Panasonic U-140PZ2R5 User manual

Panasonic WH-UD05JE5 User manual

Panasonic

Panasonic WH-UD05JE5 User manual

Panasonic CS-RE18NKE User manual

Panasonic

Panasonic CS-RE18NKE User manual

Panasonic U-72ME2U9 User manual

Panasonic

Panasonic U-72ME2U9 User manual

Panasonic CS-F24DTE5 User manual

Panasonic

Panasonic CS-F24DTE5 User manual

Panasonic CS-E15CKP User manual

Panasonic

Panasonic CS-E15CKP User manual

Panasonic CU-PW12GKX User manual

Panasonic

Panasonic CU-PW12GKX User manual

Panasonic CS-A12CKP User manual

Panasonic

Panasonic CS-A12CKP User manual

Panasonic CS-E9GKR User manual

Panasonic

Panasonic CS-E9GKR User manual

Panasonic CS-A24BD3P User manual

Panasonic

Panasonic CS-A24BD3P User manual

Panasonic CS-C18HKF User manual

Panasonic

Panasonic CS-C18HKF User manual

Panasonic CS-V18RKA User manual

Panasonic

Panasonic CS-V18RKA User manual

Panasonic CU-5E36QBU User manual

Panasonic

Panasonic CU-5E36QBU User manual

Panasonic S-36PT2E5B User manual

Panasonic

Panasonic S-36PT2E5B User manual

Panasonic CU-5MX1SPP User manual

Panasonic

Panasonic CU-5MX1SPP User manual

Panasonic CU-3KS19NBU Operating manual

Panasonic

Panasonic CU-3KS19NBU Operating manual

Panasonic S-15MF3E5B User manual

Panasonic

Panasonic S-15MF3E5B User manual

Panasonic CU-C125KE User manual

Panasonic

Panasonic CU-C125KE User manual

Panasonic CS-A24BB4P User manual

Panasonic

Panasonic CS-A24BB4P User manual

Panasonic CS-HE9PKE User manual

Panasonic

Panasonic CS-HE9PKE User manual

Panasonic CS-PS9NKP User manual

Panasonic

Panasonic CS-PS9NKP User manual

Panasonic CS-FZ25WKE User manual

Panasonic

Panasonic CS-FZ25WKE User manual

Panasonic U-8ME2R8E User manual

Panasonic

Panasonic U-8ME2R8E User manual

Popular Air Conditioner manuals by other brands

Mitsubishi Electric MSZ-GE60VA null

Mitsubishi Electric

Mitsubishi Electric MSZ-GE60VA null

Samsung AVMFC052EA0(4) null

Samsung

Samsung AVMFC052EA0(4) null

Haier HSU-09H03/R null

Haier

Haier HSU-09H03/R null

Haier HSU-24C03 null

Haier

Haier HSU-24C03 null

Mitsubishi Electric MSZ-GE22VA null

Mitsubishi Electric

Mitsubishi Electric MSZ-GE22VA null

Samsung AVMCH052CA1 null

Samsung

Samsung AVMCH052CA1 null

nedis ACMB1WT7 quick start guide

nedis

nedis ACMB1WT7 quick start guide

Daikin FCFV50A Operation manual

Daikin

Daikin FCFV50A Operation manual

Fujitsu Inverter ASBA30JFC operating manual

Fujitsu

Fujitsu Inverter ASBA30JFC operating manual

Toshiba RAS-M10SMUV-E installation manual

Toshiba

Toshiba RAS-M10SMUV-E installation manual

Daikin FXLQ20MAVE Operation manual

Daikin

Daikin FXLQ20MAVE Operation manual

CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

CIAT

CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

Bestron AAC6000 instruction manual

Bestron

Bestron AAC6000 instruction manual

Frigidaire FFRE0533S1E0 Use & care guide

Frigidaire

Frigidaire FFRE0533S1E0 Use & care guide

Samsung AS09HM3N user manual

Samsung

Samsung AS09HM3N user manual

Frigidaire CRA073PU11 use & care

Frigidaire

Frigidaire CRA073PU11 use & care

Soleus Air GB-PAC-08E4 operating instructions

Soleus Air

Soleus Air GB-PAC-08E4 operating instructions

McQuay MCK020A Technical manual

McQuay

McQuay MCK020A Technical manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

6
INSTALLATION FOR FV-07VBA1 (WALL MOUNTING)
c
ga
Install the fan at least 1.5m (5 feet) above the floor.
The motor/grille assembly FV-07VBB1 must be installed with housing can FV-07VBA1 that
is marked on the carton to indicate the suitability with this model. Other motor/grille
assembly can not be substituted.
ga
(ST4.2X20) 12
h
h
a
a
a
a
c
b
b
m
mm
m
m
ga
5
1. Affix the fan housing to joist with 3 long
screws (ST4.2X20) by affixing first 1 screw
2. Install the v duct and secure it entilation
with a clamp and seal it with mastic or
approved foil tape. A 4 inch circular duct is
needed to connect to the relevant part of
adaptor. (Fig.2) Fig.1
Fig.2
Fig.3
INSTALLATION FOR FV-07VBA1(JOIST MOUNTING)
3 Long screws
(ST4.2X20)
Joist
Fan
housing
Clamps
Key hole
Clamps
Tongue
Adaptor
Ventilation duct
Mastic or approved
foil tape
Fan housing
Conduit
Junction
box
Earth ground
to green
Neutral to white
Live to black
Wire nut
ADAP
T
O
R
AD
APTOR
JUNCTION
BOX
JUNCTION
BOX
Thermally - protected
(114 Fuse in motor)
C
Thermally - protected
(114 Fuse in motor)
C
Fan body
Junction box
Black
Switch
I-Standard
II-Boost
Capacitor
Earth ground
AC120V 60Hz
Power supply
White
Live
Neutral
Motor
White
Red
Black Black
White
Green
Yellow Yellow
1
2
B
A
Junction box cover
5. Refer to wiring diagram.
Follow all the local electrical safety codes
as well as the National Electrical Code(NEC).
Using UL approved wire nuts, connect house
power wires to ventilating fan wires.
The clamps of the adaptor should be
clipped on fan housing correctly.
Install the adaptor and secure
v duct before installingentilation
junction box.
3. Slide the clamps of the adaptor to the top
of the fan housing and then snap the clamps
of the adaptor into the bottom of the fan
housing opening. (Fig. 2)
4. Remove junction box cover and secure
conduit or strain relief to junction box cover
knock-out hole ( A or B ). (Fig.3)
6. Affix the junction box cover to junction box.
If the knock-out hole is used B , this step
must be performed after step 8.
7. Insert the tongue on the bottom of the
junction box so that it is on the outside of
the fan housing.
Before affixing screw (ST4.2X8), make
sure the tongue of the junction box is
clipped on fan housing correctly. (Fig.3)
8. Affix the junction box to the top of the
fan housing with screw (ST4.2X8). (Fig.4)
Mount junction box cover carefully so
that lead wires are not pinched.
Fig.4
Switch
Screw
(ST4.2X8)
AD
APTO
RJUNCTION
BOX
Fan housing
Junction box
on the bottom of the joist, hang up the fan
housing through the key hole, tighten the
screw, then affix other 2 screws. (Fig.1)
6
INSTALLATION FOR FV-07VBA1 CONTINUED
10. Finish ceiling work. Ceiling hole should be
aligned with the inside edge of the flange.
(Fig.5)
Fig.5
After finishing the ceiling job, fill gap between flange and
ceiling with caulk or other sealant to prevent air leakage.
7 7/8 (200)
7 7/8 (200)
Ceiling
Housing can
9. Select the air volume speed by adjusting
the switch. Factory setting is "I" (Standard)
position; pressing "II" (Boost) s the elects
high airflow position. (Fig.4 of page 5 )
9. Select the air volume speed by adjusting the switch. Factory setting is "I" (Standard) position;
pressing "II" (Boost) s the high airflow position. elects (Fig.4 of page 5 )
INSTALLATION FOR FV-07VBA1(WALL MOUNTING)
After finishing the wall job, fill gap between
flange and wall with caulk or other sealant
to prevent air leakage.
7 7/8 (200)
7 7/8 (200)
Housing can
Fig.7
1. Affix the fan housing to stud with 3 long screws
(ST4.2X20) by affixing first 1 screw in front of the
3. Slide the clamps of the adaptor to the top of the fan
housing and then snap the clamps of the adaptor into
the bottom of the fan housing opening. (Fig. 2 of page 5)
2. Install the v duct and secure it with a entilation
clamp and seal it with mastic or approved foil tape.
A 4 inch circular duct is needed to connect to the
relevant part of adaptor. (Fig.2 of page 5)
6. Affix the junction box cover to junction box.
If the knock-out hole is used B , this step must be performed after step 8.
7. Insert the tongue on the bottom of the junction box so that it is on the outside of the fan housing.
8. Affix the junction box to the top of the fan housing with screw (ST4.2X8). (Fig.4 of page 5)
4. Remove junction box cover and secure conduit
or strain relief to junction box cover knock-out
hole ( A or B ). (Fig.3 of page 5)
5. Refer to wiring diagram.
Follow all the local electrical safety codes as well
as the National Electrical Code(NEC).
Using UL approved wire nuts, connect house
power wires to ventilating fan wires.
10. Finish wall work. Wall hole should be aligned with the inside edge of the flange. (Fig.7)
The clamps of the adaptor should be clipped
on fan housing correctly.
Install the adaptor and secure ventilation
duct before installing junction box.
Before affixing screw (ST4.2X8), make sure the tongue of the junction box is clipped on
fan housing correctly. (Fig.3 of page 5)
Mount junction box cover carefully so that lead wires are not pinched.
Fig.6
Fan housing
3 Long screws
(ST4.2X20)
stub, hang up the fan housing through the key
hole, tightenthe screw,then affix other2 screws.
(Fig.6)
Key hole
Stud
Wall
Wall
7
2.Wash and clean grille assembly.
(Use non-abrasive kitchen detergent, wipe dry with
clean cloth.)(Fig.12)
3. Remove dust and dirt from fan body using a
vacuum cleaner. (Fig.13)
1. Remove grille assembly. (Squeeze mounting springs
and pull down carefully.)(Fig.11)
4. Using a cloth dampened with kitchen detergent,
remove any dirt from Fan Body. Wipe dry with
clean cloth. (Fig.14)
5. Replace grille assembly.
WARNING
CAUTION
Fig.12
Fig.13
Fig.14
Ceiling
Vacuum
cleaner
Ceiling
Glove
Fig.11
INSTALLATION FOR FV-07VBB1
3. Insert the grille assembly mounting springs into the
slots as shown and mount grille assembly to fan body .
(Fig.10) Fig.10
Grille assembly
Grille assembly
Mounting
spring
Slot
Slot
Glove
Glove
Mounting
spring
Fan body
Fig.9
Claw
Rib
Plug connector
Ceiling
2. Secure the blower / motor assembly with 2 screw
and connect the molex plug connector from the
blower to the junction box. (Fig.9)
Before turning on the fan, make sure the
connector is inserted at the correct position.
Failure to properly connect will result in fan not
working.(Fig.9)
The claw of connector must latch to the rib
completely.(Fig.9)
CAUTION
WARNING
The blower / motor assembly must be installed
into housing can tightly by the 2 screw . failure
to secure with screw will affect the grounding.
2 Screw
(ST4.2X8)
Blower / motor assembly
Adaptor
flanges
Ceiling
Fig.8
1. Insert the blower / motor assembly by sliding it into
adaptor flanges. Then press lock the blower / motor
assembly into the housing can until the blower
“clicks” into place for temporary fixation. (Fig.8)
INSTALLATION FOR FV-07VBB1
The ducting from this fan to the
outside of the building has a strong effect on the air flow, noise and energy use of the fan. Use
the shortest, straightest duct routing possible for best performance, and avoid installing the fan
with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and
inhibit mold growth. Fans installed with existing ducts may not achieve their rated air flow.
P0816-0 07VBA1M420
Fig.15
Properly insulate the area around the
fan to minimize building heat loss and
gain. (Fig.15)
Loose fill or batt insulation can be
placed directly over the fan housing in
the attic. Our fans and fan/light
combination units do not create
excessive heat that is a common
problem with recessed light fixtures or
some competitor’s fan/light
combination. Our efficient, cool-running
motors and our fluorescent lamps do
not create enough ambient heat to be
subjected to these limitations.
0.7 1.3
1.51.5
Panasonic Corporation 2016
Printed in Mexico
56
75