
2
TABLE OF CONTENTS
PAGE PAGE
1.Safety Precautions .............................................3
2.Precaution for Using R32 Refrigerant ..............5
3.Specifications .....................................................9
4.Features.............................................................20
5.Location of Controls and Components..........21
5.1Indoor Unit ..................................................21
5.2Outdoor Unit ...............................................21
5.3Remote Control ..........................................21
6.Dimensions .......................................................22
6.1Indoor Unit ..................................................22
6.2Outdoor Unit ...............................................23
7.Refrigeration Cycle Diagram ...........................24
8.Block Diagram ..................................................25
8.1Indoor Unit ..................................................25
8.2Outdoor Unit ...............................................26
9.Wiring Connection Diagram ............................27
9.1Indoor Unit ..................................................27
9.2Outdoor Unit ...............................................28
10.Electronic Circuit Diagram ..............................29
10.1Indoor Unit ..................................................29
10.2Outdoor Unit ...............................................30
11.Printed Circuit Board .......................................31
11.1Indoor Unit ..................................................31
11.2Outdoor Unit ...............................................33
12.Installation Instruction.....................................34
12.1Select the Best Location.............................35
12.2Indoor Unit ..................................................36
12.3Outdoor Unit ...............................................41
13.Installation and Servicing Air Conditioner
using R32 ..........................................................47
13.1About R32 Refrigerant................................47
13.2Characteristics of R32 Refrigerant .............47
13.3Refrigerant piping installation • Tools used
in services...................................................49
13.4New installation, Relocation, Repairing of
Refrigerant Cycle System The
Procedures .................................................53
13.5Piping installation of R32............................54
13.6Installation, Relocation, and Service ..........55
13.7Repairing of refrigerant cycle / Brazing
point............................................................59
13.8<Reference> Analysis method for no error
code, no cooling / no warming....................65
14.Operation Control.............................................67
14.1Basic Function ............................................67
14.2Indoor Fan Motor Operation .......................68
14.3Outdoor Fan Motor Operation ....................69
14.4Airflow Direction..........................................70
14.5Timer Control..............................................72
14.6Sleep Mode Operation ...............................73
14.7Auto Restart Control...................................73
14.8Indication Panel ..........................................73
14.9Quiet Operation (Cooling Mode/Cooling
Area of Dry Mode) ......................................73
14.10Quiet Operation (Heating) ..........................74
14.11Powerful Mode Operation...........................74
15.Operation Control (For Multi Split
Connection).......................................................75
15.1Cooling operation .......................................75
15.2Soft Dry Operation......................................75
15.3Heating Operation ......................................75
15.4Automatic Operation...................................76
15.5Indoor Fan Motor Operation .......................76
15.6Powerful Mode Operation...........................76
15.7Auto Restart Control...................................76
15.8Indication Panel ..........................................76
16.Protection Control ............................................77
16.1Protection Control for All Operations..........77
16.2Protection Control for Cooling & Soft Dry
Operation....................................................79
16.3Protection Control for Heating
Operation....................................................80
17.Servicing Mode .................................................82
17.1Auto OFF/ON Button ..................................82
17.2Heat Only Operation...................................83
17.3Remote Control Button...............................84
18.Troubleshooting Guide....................................87
18.1Refrigeration Cycle System........................87
18.2Breakdown Self Diagnosis Function...........89
18.3Error Codes Table ......................................90
18.4Self-diagnosis Method................................92
19.Disassembly and Assembly Instructions ... 120
19.1Indoor Electronic Controllers, Cross Flow
Fan and Indoor Fan Motor Removal
Procedures .............................................. 120
19.2Outdoor Electronic Controller Removal
Procedure ................................................ 124
20.Technical Data ............................................... 125
20.1Cool Mode Performance Data................. 125
20.2Heat Mode Performance Data................. 126
21.Service Data ................................................... 127
21.1Cool Mode Outdoor Air Temperature
Characteristic........................................... 127
21.2Heat Mode Outdoor Air Temperature
Characteristic........................................... 129
21.3Piping Length Correction Factor.............. 131
22.Exploded View and Replacement Parts
List .................................................................. 132
22.1Indoor Unit ............................................... 132
22.2Outdoor Unit ............................................ 135