manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Panasonic
  6. •
  7. Fire Alarm
  8. •
  9. Panasonic 3314 User manual

Panasonic 3314 User manual

Other Panasonic Fire Alarm manuals

Panasonic MEW01349 User manual

Panasonic

Panasonic MEW01349 User manual

Panasonic EBL512 User manual

Panasonic

Panasonic EBL512 User manual

Panasonic EBL512 User manual

Panasonic

Panasonic EBL512 User manual

Panasonic EBL512 G3 5000 User manual

Panasonic

Panasonic EBL512 G3 5000 User manual

Panasonic 4479 User manual

Panasonic

Panasonic 4479 User manual

Panasonic EBL128 Technical manual

Panasonic

Panasonic EBL128 Technical manual

Panasonic EBL128 User manual

Panasonic

Panasonic EBL128 User manual

Panasonic EBL128 4550 Installation guide

Panasonic

Panasonic EBL128 4550 Installation guide

Panasonic 6362 User manual

Panasonic

Panasonic 6362 User manual

Panasonic EBL128 User manual

Panasonic

Panasonic EBL128 User manual

Panasonic MEW01091 User manual

Panasonic

Panasonic MEW01091 User manual

Panasonic Firetracker FT1020G3 CIE User manual

Panasonic

Panasonic Firetracker FT1020G3 CIE User manual

Panasonic EBL512 User manual

Panasonic

Panasonic EBL512 User manual

Panasonic Firetracker FT1020G3 CIE Owner's manual

Panasonic

Panasonic Firetracker FT1020G3 CIE Owner's manual

Popular Fire Alarm manuals by other brands

Simplex 4010ES Quick reference guide

Simplex

Simplex 4010ES Quick reference guide

Global Fire Equipment VALKYRIE AS manual

Global Fire Equipment

Global Fire Equipment VALKYRIE AS manual

Zeta Alarm Systems INFINITY ID2 installation manual

Zeta Alarm Systems

Zeta Alarm Systems INFINITY ID2 installation manual

System Sensor 22051TLE-RF-26 Installation and maintenance instructions

System Sensor

System Sensor 22051TLE-RF-26 Installation and maintenance instructions

Pittway Notifier AM2020 troubleshooting guide

Pittway

Pittway Notifier AM2020 troubleshooting guide

Ampac ZoneSense user manual

Ampac

Ampac ZoneSense user manual

Kidde VM-1 Technical reference manual

Kidde

Kidde VM-1 Technical reference manual

LST SIM016-3 Specification sheet

LST

LST SIM016-3 Specification sheet

Fireboy- Xintex FBD-MZ Owner's Manual & Installation Instructions

Fireboy- Xintex

Fireboy- Xintex FBD-MZ Owner's Manual & Installation Instructions

GST DI-9204 Installation

GST

GST DI-9204 Installation

Fire-Lite Alarms MS-2 instructions

Fire-Lite Alarms

Fire-Lite Alarms MS-2 instructions

hyfire HY5000 Series install guide

hyfire

hyfire HY5000 Series install guide

Radionics Radionics 9124 user guide

Radionics

Radionics Radionics 9124 user guide

UniPOS FD 7120 instruction manual

UniPOS

UniPOS FD 7120 instruction manual

Teletek electronics SensoMAG MRB50 installation instructions

Teletek electronics

Teletek electronics SensoMAG MRB50 installation instructions

bolid S2000-IP-03 instruction manual

bolid

bolid S2000-IP-03 instruction manual

FIREGUARD GLOBAL FG-S01_AP quick start guide

FIREGUARD GLOBAL

FIREGUARD GLOBAL FG-S01_AP quick start guide

Notifier UZC-256 installation manual

Notifier

Notifier UZC-256 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Panasonic Eco Solutions Nordic AB
Jungmansgatan 12, SE-211 19 Malmö, Sweden
Tel: +46 (0)40 697 70 00 •Fax: +46 (0)40 697 70 99
E-mail: info.pew[email protected].com •Internet: pesn.panasonic.se
Fire alarm systems
Address setting tool
3314
Used for address and mode setting
COM loop address setting
Address setting tool 3314 is used to program
the COM loop address on the analog
detector types 33xx / 430x and all other
addressable units (33xx and 43xx).
Mode setting
The address setting tool 3314 is also used to
set the NORMAL, 2330 or 2312 mode to
the units. See the instructions for the unit
respectively.
Connection cable
Some units have flying leads for easier
connection of 3314. Some units have screw
terminals. A connection cable with
insulated crocodile clips and push-on
terminals is supplied with the address setting
tool, to be used when required.
User friendly
The address setting tool is powered by four
1.5 V batteries (LR6 / AA).
Procedure for reading / writing:
Set the ON/OFF switch on the address
setting tool in position "ON". LED
"POWER" lights up. Wait for a beep.
Plug the analog detector contact pins
(SA / SB) into the address setting tool's
snap connectors (SA / SB) or use the
connection cable to connect other units.
How to read:
Press the "READ" button. Wait for a
beep and read the address and mode in
the display.
How to write:
Select MODE by pressing the "WRITE"
and "READ" buttons at the same time
until the marker in the display is in the
correct MODE position.
Type-in the COM loop address and
press "WRITE". Wait for a beep.
Press the "READ" button for a check.
Wait for a beep and read the address and
the mode.
Write the COM loop address on the Address
label on the detector (and the base) or on the
unit.
After using the address setting tool, it should
be turned OFF. (If the tool is left not used
for more than 2 minutes, it will
automatically be turned off.)
Product applications
Used when analog detectors and other
addressable COM loop units are to be used
in the systems EBL128 / 512 / 512 G3 /
1000 / 2000.
All technical features and data are subject to changes without notice, resulting from continuous development and improvement.
Product Leaflet
Date of issue
Revision / Date of revision
MEW00054
2000-08-24
5 / 2011-03-09
Type numbers
3314
Address setting tool (incl. connection cable)
3315
Connection cable for Address setting tool 3314 (spare part)
Left: An analog detector is plugged into the address setting tool's snap connectors.
Right: Connection cable, to be used when required.
Technical data
Power supply (V DC)
4.6-6. 4 pieces of 1.5 V batteries (LR6 / AA).
Current consumption at nom. volt.
(mA)
<100
Ambient temperature (C)
operating
storage
0 to +40
0 to +40
Ambient humidity (% RH)
max. 95, non condensing
Ingress Protection rating (estimated)
IP42
Material
ABS plastic (housing)
Size L x W x H (mm)
L (mm)
153 x 68 x 42
540 (connection cable)
Weight (g)
270 (incl. batteries)
15 (connection cable)
Colour (housing)
Black