manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Paradox
  6. •
  7. Control Unit
  8. •
  9. Paradox ZX16D User manual

Paradox ZX16D User manual

ZX16D - page 1
ZX16D: 16 Zone Expansion Module
Description
Driven by the V32 main controller’s 4-wire communication
bus (Multibus), the ZX16D is a DIN module with 16 inputs
for home automation or security with a status display for
each input. The module offers a test mode with 5 different
tests for input connectivity and operation, and full remote
firmware upgradeability.
With its DIN rail design, the module saves space, and
makes installation and wiring significantly faster and easier.
Features
• 16 zones or inputs
• Diagnostic Mode: Zone LEDs turn on/off to identify
assigned zone inputs, verify correct wiring (no EOL,
EOL without tamper, EOL with tamper) and perform a
walk test
• Remote firmware upgradeability via Multibus
• DIN rail design with on-board status display, and
removable terminals
• Programming via BabyWare software
• Bi-directional LOCATE feature from module to software
and vice versa
Overview
1) Module Locate feature activation (see "Bi-directional
Locate Feature” on page 3)
2) Multibus input status LEDs ("LED Feedback” on page 2)
3) Input status LEDs ("LED Feedback” on page 2)
4) Product serial number
A) 4-wire Multibus connection
B) Device inputs
Related Topics Specifications
Installation / Wiring
• DIN Rail Enclosures
• System Diagrams and Wiring Tips
• Wire Gauge Selection
Features
• Bi-directional Locate Feature (see page 3)
• Remote Firmware Upgrade (see page 3)
BabyWare
• BabyWare
Input voltage Typically 12Vdc (from Multibus)
Multibus 4 wires at up to 900m (3,000ft)
Current
consumption
68mA
Number of
device inputs
16 standard device inputs
Dimensions Standard DIN6: 11cm X 10cm X 6cm (4.2” X 4” X
2.5”)
Operating
Temperature
-10ºC to 50ºC
(14ºF to 122ºF)
TM
DRAFT
Installation/Wiring: ??
Programming 1: ??
Programming 2: ??
Testing: ??
Total Tim e : ??
B
3
A
2
4
1
ZX16D - page 2
Wiring
LED Feedback
Test Mode
To facilitate installation and verify correct wiring, the ZX16D features five Test Modes. In order to use this feature, the
ZX16D module must be powered (Test Mode 1 requires a full bus connection).
To enter Test Mode, press the LOC button. The ZX16D enters Test Mode 1. Press the LOC button again to enter Test Mode
2, and so on. On the sixth press, the ZX16D will exit Test Mode.
1INPUT DEVICES
For input device wiring options, see ??
2EXTERNAL MODULE TAMPER SWITCH
Input 16 (N.C.) only.
ZX16D
INPUT
12 34CC
INPUT
56789
CC
INPUT
10 11 12 13 14 15 16 CC
BUS INPUT
Detection Device
N.O. N.C. C +_
Imperial Multibus
1
2
ZX16D
INPUT
12 34CC
INPUT
56789
CC
INPUT
10 11 12 13 14 15 16 CC
BUS INPUT
BUS RX TX STATUS
Green Green
flash
Green
flash
OK (communication in
progress)
Red
on
- - Short on GRN or YEL
- Green
on
Communication failure/
too many modules
Green
on
Green
on
Bus lines reversed (GRN
/ YEL)
Red
flash
- - Bus power too low
Green
flash
Green
flash
Module locate mode
Blue
flash
- - Firmware upgrade in
progress
Input Status LEDs
Off = Input/zone closed
Red on = Input/zone open
Red flash = zone tamper
Mode Feature LED
Feedback Instructions
Mode 1* Input assignment RX flashes x 1 Entering Mode 1 illuminates all zones that have already been assigned in the control
panel.*This feature will be available on future versions.
Mode 2 EOL disabled
Tamper disabled
RX flashes x 2 Entering Mode 2 sets the ZX16D for: No EOL / No tamper. To verify correct EOL /
tamper wiring, open and close the zone and verify that the zone’s LED reacts
accordingly.
Mode 3 EOL enabled
Tamper disabled
RX flashes x 3 Entering Mode 3 sets the ZX16D for: With EOL / No tamper. To verify correct EOL /
tamper wiring, open and close the zone and verify that the zone’s LED reacts
accordingly.
Mode 4 EOL enabled
Tamper enabled
RX flashes x 4 Entering Mode 4 sets the ZX16D for: With EOL / With tamper. To verify correct EOL /
tamper wiring, open and close the zone and verify that the zone’s LED reacts
accordingly.
Mode 5 Zone test RX flashes x 5 Entering Mode 5 illuminates all connected zones. When a zone is triggered, the
corresponding zone LED will turn off, indicating correct wiring.
ZX16D - page 3
Bi-directional Locate Feature
Pressing and holding the LOC button for 3 seconds will initiate the Module Locate feature. When a Module Locate is
initiated, the module’s representation in the BabyWare software will flash and the module’s BUS, RX and TX LEDs will flash
at 1Hz to indicate that it is in locate mode. A module locate can also be initiated from the BabyWare software. From
BabyWare right-click the module’s representation and select Locate Physical. The module’s BUS, RX and TX LEDs will
flash. We highly recommend that after pressing locate and identifying the module, open the programming page and assign
the proper physical location label and the doors’ labels and locations. After complete connection, use the space provided
on the module to indicate the doors’ description.
Remote Firmware Upgrade
Work in progress...
The ZX16D is firmware upgradeable remotely via the V32 controller’s Multibus at 57.6Kbps. Using BabyWare connect to
the V32 account using any of the connection methods (direct connect, IP static, or IP DNS). Right-click the desired module
and select Upgrade (???). When communicating through the Internet, BabyWare will indicate whether the panel or any of
the bus modules have a newer firmware version available. A firmware upgrade for a single module or group of modules will
take usually less than 10 minutes, which keeps system downtime to a minimum.
Programming a ZX16D Module
1) When BabyWare is communicating with the V32 controller and a ZX16D
module is connected to the Multibus, it automatically appears in the Modules
display area. To view the Modules display area, click the Modules toggle
button. Alternatively, you may wish to add a module to BabyWare before the
module is physically connected to the system. Click the Add Item button.
2) To program a module that already appeared in the system, double-click the
module’s icon. The ZX16D Programming window opens.
3) From the ZX16D Programming window, configure input speeds and general
options. Click OK.
Figure 1: ZX16D Programming
ZX16D - page 4
Patents: One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111, 5119069,
5077549 and RE39406 and other pending patents may apply. Canadian and international patents may also apply.
Trademarks: Paradox Imperial, MAMA, BabyWare, the M logo, and the triangle logo are trademarks or registered trademarks of Paradox Security
Systems Ltd. or its affiliates in Canada, the United States and/or other countries.
Certification: For the latest information on products approvals, such as UL and CE, please visit www.paradox.com.
Warranty: For complete warranty information on this product please refer to the Limited Warranty Statement found on the website www.paradox.com/
terms. Your use of the Paradox product signifies your acceptance of all warranty terms and conditions.
© 2009 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice.
PARADOX.COM
Printed in Canada - 03/2009
IZX16-EI00

Other Paradox Control Unit manuals

Paradox MG-RCV3 User manual

Paradox

Paradox MG-RCV3 User manual

Paradox PCS250G Installation guide

Paradox

Paradox PCS250G Installation guide

Paradox IP100 User manual

Paradox

Paradox IP100 User manual

Paradox ZX8 User manual

Paradox

Paradox ZX8 User manual

Paradox Digiplex EVO PRT3 Installation manual

Paradox

Paradox Digiplex EVO PRT3 Installation manual

Paradox Digiplex EVO EVO192 V7.11 Operating instructions

Paradox

Paradox Digiplex EVO EVO192 V7.11 Operating instructions

Paradox Magellan VG-RTX3 User manual

Paradox

Paradox Magellan VG-RTX3 User manual

Paradox ZX82 User manual

Paradox

Paradox ZX82 User manual

Paradox PCS265 User manual

Paradox

Paradox PCS265 User manual

Paradox RTX3 User manual

Paradox

Paradox RTX3 User manual

Paradox PCS300 User manual

Paradox

Paradox PCS300 User manual

Paradox Digiplex EVO ZX8D User manual

Paradox

Paradox Digiplex EVO ZX8D User manual

Paradox PCS265 LTE Installation guide

Paradox

Paradox PCS265 LTE Installation guide

Paradox ZX8 User manual

Paradox

Paradox ZX8 User manual

Paradox Digiplex EVO PRT3 Installation manual

Paradox

Paradox Digiplex EVO PRT3 Installation manual

Paradox IMPERIAL DIGIPLEX EVO ACM24D User manual

Paradox

Paradox IMPERIAL DIGIPLEX EVO ACM24D User manual

Paradox IP150 User manual

Paradox

Paradox IP150 User manual

Paradox IP150+ User manual

Paradox

Paradox IP150+ User manual

Paradox ZX22 User manual

Paradox

Paradox ZX22 User manual

Paradox PGM82 User manual

Paradox

Paradox PGM82 User manual

Paradox VDMP3 User manual

Paradox

Paradox VDMP3 User manual

Paradox PCS265 LTE Installation guide

Paradox

Paradox PCS265 LTE Installation guide

Paradox MG-RCV3 User manual

Paradox

Paradox MG-RCV3 User manual

Paradox IP150 User manual

Paradox

Paradox IP150 User manual

Popular Control Unit manuals by other brands

Paradigm Defiance WT owner's manual

Paradigm

Paradigm Defiance WT owner's manual

Harvia C80/1 manual

Harvia

Harvia C80/1 manual

Jung MSC 1000 KNX operating instructions

Jung

Jung MSC 1000 KNX operating instructions

Xblue Networks X16 Quick reference card

Xblue Networks

Xblue Networks X16 Quick reference card

Siemens HOTEL SOLUTION HTC3.2 Series quick start guide

Siemens

Siemens HOTEL SOLUTION HTC3.2 Series quick start guide

Waterworks GUVC16 Service manual

Waterworks

Waterworks GUVC16 Service manual

Lenze E94AZHY0026 Mounting instructions

Lenze

Lenze E94AZHY0026 Mounting instructions

Weinmann & Schanz Heatapp! System Installation instruction

Weinmann & Schanz

Weinmann & Schanz Heatapp! System Installation instruction

DuraComm DC-RMCU1 owner's guide

DuraComm

DuraComm DC-RMCU1 owner's guide

BENDIX E-14 DUAL BRAKE VALVE manual

BENDIX

BENDIX E-14 DUAL BRAKE VALVE manual

Vaillant VR 15 installation instructions

Vaillant

Vaillant VR 15 installation instructions

Trillium SARASIN-RSBD STARFLOW V Series Installation, operation & maintenance manual

Trillium

Trillium SARASIN-RSBD STARFLOW V Series Installation, operation & maintenance manual

Panasonic ELC500 user manual

Panasonic

Panasonic ELC500 user manual

Jafar 7010 Operation and maintenance manual

Jafar

Jafar 7010 Operation and maintenance manual

LSIS XGT Series user manual

LSIS

LSIS XGT Series user manual

Honeywell C7110C1040 manual

Honeywell

Honeywell C7110C1040 manual

heat-timer ETS-LT Installation and operation manual

heat-timer

heat-timer ETS-LT Installation and operation manual

Vortice SCNRL5 Instruction booklet

Vortice

Vortice SCNRL5 Instruction booklet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.