PARADOX.COM PCS265L-EI00 09/2018
GSM Reporting (EBUS Connection)
Reporting Options
SMS Messages for Backup
Additional Programming Options
SMS Language
SMS languages can be upgraded locally using the “Firmware”
section of the PCS265 LTE on our website. It allows you to
download version 4.20 (or higher) in the SMS language of your
choice. The below table lists the languages available.
List of SMS Commands
Technical Specifications
Safety Note: This device may operate continuously in temperature
of 55°C (131°F) for a maximum period of 7 days.
If you have any comments please write to us at Paradox.com/
products/feedback.
Receiver
Settings MG/SP
Receiver #:
IP address*
IP port **
IP address
WAN 2
IP port WAN2
Receiver pass-
word
Security Profile
1
[929]
[930]
[931]
[932]
[933]
[934]
2
[936]
[937]
[938]
[939]
[940]
[941]
Backup
[943]
[944]
[945]
[946]
[947]
[948]
Module registra-
tion - Press
[ARM] to register
[935] [942] [949]
Receiver
Settings EVO
Receiver #:
IP address*
IP port **
IP address
WAN 2
IP port WAN2
Receiver pass-
word
Security Profile
1
[2984]
2
[2986]
3
[2988]
4
[2990]
* For 1 or 2 digit numbers, add “0’s” before the digit: e.g.,
138.002.043.006
** Default = 10000
Enter [MEM] for blank space
MG/SP EVO Details
[805] [2950] [1] Off + [2] Off = landline only (default)
[1] Off + [2] On = landline primary / GSM
backup (default)
[1] On + [2] Off = GSM primary / landline
backup
[1] On + [2] On = GSM only
[815] to
[817]
[3071] to
[3074]
Telephone numbers
[811] to
[812]
[3061] to
[3068]
Account numbers
Command Description
P[PASSWORD].SMS[GSM MODEM
TELEPHONE #].[IPRS-7
PASSWORD]
Used to program the
receiver’s SMS parameters
SMS Languages
English
(default)
Estonian Italian Russian
Albanian Finnish Latvian Serbian
Belgian French Lithuanian Slovak
Bulgarian French
Canadian
Macedonian Slovenian
Chinese German Malay Spanish
Croatian Greek Polish Swedish
Czech Hebrew Portuguese Turkish
Dutch Hungarian Romanian
Command Description
P[password].A[IP
address].P[port number]
Used for LTE/4G/3G/2G remote
access
P[password].IP.[call back
phone number]
Used to obtain the IP address and
IP port of the PCS265 LTE and
whether or not the “bandwidth
saver” option is being used
P[password].RESET Used to reset the PCS265 LTE
P[password].BWS.ON Used to enable bandwidth saver
mode
P[password].BWS.OFF Used to disable bandwidth saver
mode
P[password].VOLOUT.[GSM
output volume]
Used to set the GSM output
volume; values range between 50
to 100
P[password].STATUS.[phone
number]
Used to obtain the signal strength,
signal quality, LTE/4G/3G/2G
connection status, and APN
settings of the current SIM card
P[password].APN1.NAME.
[AccessPoint Name]
Used to program the SIM Card 1
APN
P[password]
.APN1.USER.[Access
Point Name]
Used to program the SIM card 1
APN User Name
P[password]
.APN1.PSW.[Access
Point Name]
Used to program the SIM card 1
APN Password
P[password].APN1.CLEAR ] Used to clear the SIM Card 1 APN
P[password]
.VAPN1.NAME.[Access
Point Name]
Used to view the SIM card 1 APN
P[password].APN2.NAME.
[AccessPoint Name]
Used to program the SIM card 2
APN
P[password]
.APN2.USER.[Access
Point Name]
Used to program the SIM card 2
APN User Name
P[password]
.APN2.PSW.[Access
Point Name]
Used to program the SIM card 2
APN Password
P[password].APN2.CLEAR Used to clear the SIM card 2 APN
P[password].VAPN2.[CALL
BACK PHONE NUMBER]
Used to view the SIM card 2 APN
information
P[password].[IP1W1/ IP1W2/
IP2W1/ IP2W2/ IP3W1/
IP3W2/
IP4W1/ IP4W2].[domain
name]
Set domain name for LTE/4G/3G/
2G receiver
P[password].[IP1W1/ IP1W2/
IP2W1/ IP2W2/ IP3W1/
IP3W2/IP4W1/ IP4W2]
.CLEAR
Clear domain name for LTE/4G/3G/
2G receiver
P[password].DNS.[ip
address]
Set domain name server (DNS) IP
address
P[password].DNS.CLEAR Clear domain name server (DNS)
IP address
P[password].VIP.[phone
number]
Get domain name server (DNS) info
C[user code].[ARM/
OFF].A[area
number], [area number], [area
number]TO[area number]
Arm/Disarm
Specifications Description
RF Power Class 4 (2W) @ 850/1900 MHz
Class 2 (1W) @ 1800/1900 MHz
UMTS 850/1900 @ 0.25W
(America)
UMTS 900/2100 @ 0.25W (Europe)
Antenna Bandwidth 5 bands, wideband
Voltage Input 12 VDC nominal
Consumption during
GPRS/GSM transmission
60mA standby
300 mA maximum
Encryption 128-bit (AES)
SMS Protocol 7-bit (GSM: 3GPP TS 23.038/
GSM03.38)
or 16-bit (UCS2 ISO/IEC10646)
SIM Cards LTE/4G/3G
GSM (2G - n/a for North and South
America)
Humidity 0 - 90% non-condensing
Operating Temperature -20 - 50 °C (-4 to 122 °F)
Dimensions 20.8 x 7.5 x 2 cm / 8.2 x 2.9 x 0.8 in.
Certifications EN 50131-1 Grade 3 Class II, EN
50136-1 ATS Category SP5
Command Description
Warranty
The Limited Warranty Statement can be found on the website
www.paradox.com/terms.
Patents
Your use of the Paradox product signifies your acceptance of these terms
and conditions. The following US patents may apply 5,886,632 and
6,215,399. Other Canadian and international patents may apply.
©2018 Paradox Security Systems (Bahamas) Ltd. All rights reserved.
Specifications may change without prior notice.