Spot Cooler (cold air generator) PJC series
Instruction Manual
Indications for safe use
Besuretoreadthisservicemanualbeforetheuse,maintenance,inspectionordisassemblyofthis
product,andfullyunderstandthemeaningofthefollowingindicationsforsafeuseofthespotcooler.
!
!
!
Specifications
Order code
DANGER
WARNING
CAUTION
This indication denotes an extremely high possibility that wrong handling of this product
may cause theuser to suffer death, severe injuries or fatal health harm.
This indication denotes a possibility that wrong handling of thisproduct may cause
the user to suffer death, severe injuries or fatal health harm.
This indication denotes a possibility that worng handling of this product may cause the user to
suffer severe injuries or may impair user’ s health or may lead to property damage.
PJC-150:Rc1/8
PJC-300:Rc1/4
PJC-450:Rc3/8
PJC-600:Rc3/8
PJC-900:Rc3/4
PJC-150:0.25kg
PJC-300:0.30kg
PJC-450:0.60kg
PJC-600:0.60kg
PJC-900:2.0kg
Working Fluid Air
Working Pressure
Proof Pressure
Ambient Temperature
Connection Size
Weight
Optional Heat insulation hose,Silencer
Magnet Mount, Hose Joint
Air
0.3 〜 0.7MPa
1.0MPa
10 〜 40℃
Part No.
Heat insulation hose
Silencer
Magnet Mount
Hose Joint
Option
H
S
M
J
*Option of PJC-900 is Heatinsulationhose only
■Spot Cooler
PJC-150
PJC-150
PJC-300
PJC-450
PJC-600
PJC-900
PJC-15H
Size
■Option
For PJC-150
For PJC-300
For PJC-450、600
For PJC-900
Applicablemodel
15
30
60
90
Silencer
Heatinsulationhose
Instructions for use
!CAUTIOIN
!WARNING
!DANGER
*Admissionofdustorlublicantmayreducethecoolingability.Supplyonlycleanair.
Piping
●Before piping, thoroughly flush inside of each pipe to remove chips, coolant, dust, etc.
●When in piping, apply seal tapes or sealant on the threaded zone.
●Pay attention so that chips or sealant may not enter inside when screwing pipes or fittings.
Execute tightening in a proper manner in the range of the specified tightening torque.
Port Size
Rc 1/8
Rc 1/4
Rc 3/8
Tightening Torque( N・m )
7.0 〜9.0
12 〜14
22 〜24
AirSource
AirDrier
Fiter Coalescing
filter
Valve
CoolingAirOutlet
AirSupply
AdjustmentScrew
HotAirExhaust
<Example of piping connection>
・Do not use this product for other purposes than its original usage or the range of its
specifications.・Do not use this product with other gases other than air.
・Do not remove any part to use it for any other equipment, or do not use any other parts
than the specified items.
・Use the product in the range of working pressure being 0.3 to 0.7MPa.
・Note that hot air is discharged from the hot air exhaustion port during the product use.
Take care not to get burnt because the section protected with mesh may become as hot as
70℃at the maximum when the inlet air temperature is 20℃depending on the use conditions.
●Moisture contained in the compressed air to be supplied will cause freezing in the cold air
outlet.
If the nozzle is frozen, ice particles will take place in the cooling air.
For prevention of such trouble, be sure to supply dry air using an air drier or similar other devices.
●Install an air filter and a coalescing filter in order to prevent the perfoemance degradation due
to dust, lublicant or other substances.
●Use pipes and tubes of as large an internal diameter as possible in the piping to the spot cooler.
Thin pipes cannot supply compressed air sufficiently, decreasing the performance.
●If a tube or the like is used for piping to the cooling air outlet, be sure to minimize the length of
the tube, wrapped around with heat insulation material.
Adjustmentofcoolingairtemperature
Use the adjustment screw at the rear of the main unit for adjustment of temperature. Counterclock-
wise turning of the adjustment screw will lower the temperature, decreasing the cold air
flow rate. Clockwise turning of the adjustment screw will bring opposite results.
AdjustmentScrew
Counterclockwise
Clockwise
Air consumption
Fault and repair
If the temperature drop has become insufficient, make inspection in the following steps
(1)Make readjustment using the adjustment screw.
(2)Check for clogging of the filter or coalescing filter, causing the drop of supply pressure.
(3)Check whether the air is supplied sufficiently.
Note that the company shall not be responsible for anything that has been disassembled by the user.
Cooling capacity and flow
Note: The number of “Turns” given in the diagram indicates the number of turns of the adjustment screw, that is, the
number of times of turning back from the fully tightened condition.The “△Temprature䉝” means the temperature
determined by the subtraction of (The inlet air temperature −The cold air temperature).
This diagram shows the characteristics of a single spot cooler. In the actual use situation, the characteristics may be
different depending on the conditions.
Air consumption ℓ/min(ANR)
Supply pressure (MPa)
PJC-150
PJC-300
PJC-450
PJC-900
PJC-600
※The data is based on the case of continuous blow.
400
300
200
100
00.51 2.521.5 3
200
160
120
80
40
0 0.5 1 1.5 2 2.5 3 3.5
300
250
200
150
100
50
0 0.5 1 1.5 2 2.5 3
800
600
400
200
00.51 2.521.5 3
80
60
40
20
0 75 150 225 300
80
60
40
20
0 100 200 300 400
80
60
40
20
0 150 300 450 600
80
60
40
20
0 300 600 900 1200
0.3 0.4 0.5 0.6 0.7MPa
0Turn
0.5Turns
1Turns
1.5Turns
2Turns
2.5Turns
0.3 0.4 0.5 0.6 0.7MPa
0Turn
0.5Turns
1Turns
1.5Turns
2Turns
2.5Turns
3Turns
0.3 0.4 0.5 0.6 0.7MPa
0㼀㼡㼞㼚
0.5㼀㼡㼞㼚㼟
1㼀㼡㼞㼚㼟
1.5㼀㼡㼞㼚㼟
2㼀㼡㼞㼚㼟
2.5㼀㼡㼞㼚㼟
2㼀㼡㼞㼚㼟
0.3 0.4 0.5 0.6 0.7MPa
0㼀㼡㼞㼚
0.5㼀㼡㼞㼚㼟
1㼀㼡㼞㼚㼟
1.5㼀㼡㼞㼚㼟
0.7MPa
0.6
0.5
0.4
0.3
0.7MPa
0.6
0.5
0.4
0.3
0.7MPa
0.4
0.5
0.6
0.3
0.7MPa
0.6
0.5
0.4
0.3
100
80
60
40
20
Number of adjusting screw
rotation
Calorific value (W)
00.51 2.521.5 3
PJC-150
80
60
40
20
0 306090120
0.3 0.4 0.5 0.6 0.7MPa
0Turn
0.5Turns
1Turns
1.5Turns
2Turns
0.3
0.5
0.4
0.6 0.7MPa
△Temprature䉝
Flow Ɛ/m(ANR)
PJC-300 PJC-450
PJC-600 PJC-900
PJC-150 PJC-300 PJC-400
PJC-600 PJC-900
※The data is based on the case of continuous blow.
Calorific value (W)
Calorific value (W)
Calorific value (W) Calorific value (W)
Number of adjusting screw
rotation Number of adjusting screw
rotation
Number of adjusting screw
rotation Number of adjusting screw
rotation
Cooling ability
Note:Thenumberofturnsofadjustmentscrewmeansthenumberofturningbackfromthefullytightened
condition.Thisdiagramshowsthecharacterisricsofasinglespotcooler.Intheactualusesituation,the
characteristicsmaybedifferentdependingontheconditions.
-741PGWOCVKEU.VF
Customer ServiceTEL +81-479-64-2282
Flow ƐwolF)RNA(m/ Ɛ/m(ANR)
Flow ƐwolF)RNA(m/ Ɛ/m(ANR)
△Temprature䉝
△Temprature䉝
△Temprature䉝
△Temprature䉝
Regulator
Calorific value (W)
Hose Joint
Magnet Mount