EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. PASCO
  6. •
  7. Laboratory Equipment
  8. •
  9. PASCO ES-9059C User manual

PASCO ES-9059C User manual

Other PASCO Laboratory Equipment manuals

PASCO TD-8498A User manual

PASCO

PASCO TD-8498A User manual

PASCO EM-8662 User manual

PASCO

PASCO EM-8662 User manual

PASCO SE-9654 User manual

PASCO

PASCO SE-9654 User manual

PASCO Hooke's Law Set ME-9827 User manual

PASCO

PASCO Hooke's Law Set ME-9827 User manual

PASCO h/e Apparatus User manual

PASCO

PASCO h/e Apparatus User manual

PASCO PS-3519 User manual

PASCO

PASCO PS-3519 User manual

PASCO ES-9080A User manual

PASCO

PASCO ES-9080A User manual

PASCO ME-9892 User manual

PASCO

PASCO ME-9892 User manual

PASCO SE-9638 User manual

PASCO

PASCO SE-9638 User manual

PASCO TD-8565 User manual

PASCO

PASCO TD-8565 User manual

PASCO TD-8572 User manual

PASCO

PASCO TD-8572 User manual

PASCO CI-6538 User manual

PASCO

PASCO CI-6538 User manual

PASCO PASCObot Gripper PS-3325 User manual

PASCO

PASCO PASCObot Gripper PS-3325 User manual

PASCO SE-6609 User manual

PASCO

PASCO SE-6609 User manual

PASCO Brolight SE-9629 User manual

PASCO

PASCO Brolight SE-9629 User manual

PASCO ME-8594 User manual

PASCO

PASCO ME-8594 User manual

PASCO PS-2600A User manual

PASCO

PASCO PS-2600A User manual

PASCO ME-6841 User manual

PASCO

PASCO ME-6841 User manual

PASCO ME-9207B User manual

PASCO

PASCO ME-9207B User manual

PASCO PS-3516 User manual

PASCO

PASCO PS-3516 User manual

PASCO ME-9502 User manual

PASCO

PASCO ME-9502 User manual

PASCO EM-6720 User manual

PASCO

PASCO EM-6720 User manual

PASCO AP-8219 User manual

PASCO

PASCO AP-8219 User manual

PASCO EM-8678A User manual

PASCO

PASCO EM-8678A User manual

Popular Laboratory Equipment manuals by other brands

Qiagen DML 3000 user manual

Qiagen

Qiagen DML 3000 user manual

Queensgate NANOSCAN OP400 Quick start instructions

Queensgate

Queensgate NANOSCAN OP400 Quick start instructions

Conviron GEN1000-GE Operator's manual

Conviron

Conviron GEN1000-GE Operator's manual

Parr Instrument 4560 Operating instructions manual

Parr Instrument

Parr Instrument 4560 Operating instructions manual

IKA IC control operating instructions

IKA

IKA IC control operating instructions

Integra DOSE IT operating instructions

Integra

Integra DOSE IT operating instructions

Agilent Technologies 5800 ICP-OES user guide

Agilent Technologies

Agilent Technologies 5800 ICP-OES user guide

Endress+Hauser Cleanfit CPA875 operating instructions

Endress+Hauser

Endress+Hauser Cleanfit CPA875 operating instructions

NI PXI-5422 CALIBRATION PROCEDURE

NI

NI PXI-5422 CALIBRATION PROCEDURE

Collomix Aqix operating instructions

Collomix

Collomix Aqix operating instructions

SPEX SamplePrep 6875 Freezer/Mill Series operating manual

SPEX SamplePrep

SPEX SamplePrep 6875 Freezer/Mill Series operating manual

Ocean Insight FLAME-NIR+ Installation and operation manual

Ocean Insight

Ocean Insight FLAME-NIR+ Installation and operation manual

Parker ALIGN-MG-NA Installation, operation and maintenance manual

Parker

Parker ALIGN-MG-NA Installation, operation and maintenance manual

BD 644787 user guide

BD

BD 644787 user guide

DENTAURUM Compact Megaplus Instructions for use

DENTAURUM

DENTAURUM Compact Megaplus Instructions for use

Biuged Laboratory Instruments BGD 626 instruction manual

Biuged Laboratory Instruments

Biuged Laboratory Instruments BGD 626 instruction manual

VWR SAS Super IAQ instruction manual

VWR

VWR SAS Super IAQ instruction manual

illumina MiSeqDx reference guide

illumina

illumina MiSeqDx reference guide

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

Instruction Sheet
012-05247C
Conductive Spheres
ES-9059C
800-772-8700 www.pasco.com
®
*012-05247*
Introduction
The PASCO ES-9059C Conductive Spheres are convenient
objects upon which to store electrical charges. The spheres are 13
centimeters (cm) in diameter and are made of nickel-plated ABS
plastic. Each is mounted on a non-conductive rod of polycarbon-
ate (about 1014 ohms) and attached to a stable support base. Each
sphere has a thumbscrew terminal on the lower half of the sphere
for attaching a ground cable or a lead from a voltage source.
NOTE: When handling the conductive spheres, take care to keep
each sphere and non-conductive rod free of dirt, grease, and fin-
gerprints to minimize leakage of charge from the spheres.
Recommended Equipment*
• Faraday Ice Pail (ES-9042A)
• Basic Electrometer (ES-9078)
• Electrostatics Voltage Source (ES-9077)
• Charge Producers and Proof Plane (ES-9057B)
Related Equipment*
• Conductive Shapes (ES-9061)
*See the PASCO catalog or web site at www.pasco.com for more informa-
tion.
Operation with a Voltage Source
To use the conductive spheres with the PASCO ES-9077 Electro-
statics Voltage Source, connect one of the high voltage power
supply output terminals (+1000 V, +2000 V, +3000 V) to the
thumbscrew terminal on the lower half of the conductive sphere.
Note that the voltage source accessories include two
banana-plug-to-spade-lug insulated wires.
If you are using the PASCO ES-9078 Basic Electrometer to mea-
sure voltage, connect the electrometer ground terminal
(GROUND) to the black ground terminal on the voltage source.
Conductive sphere
Thumbscrew
Thumbscrew
Base
Non-conductive
rod
Conductive sphere
Electrostatic
Voltage
Source
®
Conductive Spheres ES-9059C
2
Using a Proof Plane to Sample Charge
The proof plane that is a part of the PASCO ES-9057B Charge
Producers and Proof Plane can be used to transfer charge from
the surface of a conductive sphere. Place the proof plane so that it
is tangent to the surface of the conductive sphere..
NOTE: You can then use a PASCO Basic Electrometer and a
Faraday Ice Pail (ES-9042A) to measure the charge density on
the proof plane, as shown in the following illustration.
By touching the proof plane to a surface, it will acquire the same
charge distribution as the surface. By measuring the charge on
the proof plane, the charge density on the surface can be deter-
mined. The greater the charge on the proof plane, the greater the
charge density on the surface where the proof plane made con-
tact.
Cleaning the Spheres
When necessary, clean the sphere and the non-conductive rod
with rubbing (isopropyl) alcohol.
Technical Support
For assistance with any PASCO product, contact PASCO at:
For more information about the Conductive Spheres and the lat-
est revision of this Instruction Sheet, visit:
www.pasco.com/go?ES-9059C
Limited Warranty For a description of the product warranty, see the
PASCO catalog. Copyright The PASCO scientific 012-05247C Con-
ductive Spheres Instruction Sheet is copyrighted with all rights reserved.
Permission is granted to non-profit educational institutions for reproduction
of any part of this manual, providing the reproductions are used only in
their laboratories and classrooms, and are not sold for profit. Reproduction
under any other circumstances, without the written consent of PASCO sci-
entific, is prohibited. Trademarks PASCO and PASCO scientific are
trademarks or registered trademarks of PASCO scientific, in the United
States and/or in other countries. All other brands, products, or service
names are or may be trademarks or service marks of, and are used to
identify, products or services of, their respective owners. For more infor-
mation visit www.pasco.com/legal.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
++
Charged conductive
sphere
Proof plane is tangent
to the surface of the
conductor.
Proof plane is NOT
tangent to the surface
of the conductor.
YES!NO!
Electrometer Faraday Ice
Pail
Charged Proof Plane
Signal lead
Ground lead
Address: PASCO scientific
10101 Foothills Blvd.
Roseville, CA 95747-7100
Phone: 916-786-3800 (worldwide)
800-772-8700 (U.S.)
Fax: (916) 786-7565
Web: www.pasco.com
Email: [email protected]
Warning! Do not use acetone to clean the
sphere or the non-conductive rod!