Reference Guide
8. Power Connection
OSDP Reference Guide
7. Communication Connections
Ethernet - Red controllers accept RJ45 connections. The Red 2 controller
will be Self-Discoverable from Pdk io software. You have the option to
assign a Static IP address but is not required.
A
Wireless (PN: RMW) and PoE (PN: RMPOE)
module kits can be purchased for optional
communication add-ons.
+
-
0 1 L +
-
0 1 L
A
-
B A
-
B NC NOCNC NOC 12VDC
+GND
OSDP
OSDP
PORT1
BUS
+-
PORT2
BUS
+-
ETHERNET
POWER
HEART
LINK
ACTIVITY
BATTERY
POE IN
POE OUT
A
DC INPUT - Use included 14 VDC, 2 Amp transformer for DC power
input. It is recommended to use 18/2 wire. For high voltage applications, use
the HV Converter (PN: HVC).
BATTERY - The enclosure will fit most 12 VDC 5 Ah batteries. The battery is
connected with supplied leads and is polarity sensitive. Receive up to 8 hrs of
battery backup using a strike in fail-secure.
A
A
B
Battery
12 VDC / 5 Ah
B
What is OSDP - Open Supervised Device Protocol (OSDP) is an access control
communications standard developed by the Security Industry Association to
improve interoperability among access control and security products. OSDP
brings heightened security and improved functionality. It is more secure than
Wiegand and supports AES-128 encryption.
OSDP Wire Specication - Four (4) conductor twisted pair overall shield is
recommended to remain fully TIA-485 compliant at maximum supported baud
rates and cable distances.
NOTE - It’s possible to reuse existing Wiegand wiring for OSDP, however, using
simple stranded cable typical of Wiegand readers generally does not meet the
RS485 twisted pair recommendations.
OSDP Multi-Drop - Multi-drop gives you the capability to accommodate
many readers by running one length of 4-conductor cable, eliminating the
need to run wire for each wire.
NOTE - Four (4) is the maximum number of readers each port can support.
NOTE - Wiegand readers will not work when OSDP jumpers are installed.
Fire Input - To integrate the fire system using a Red 2 door controller, refer to
wiring diagrams in the Partner Portal at
www.prodatakey.com/resources
Programming - After the Red 2 door controller has been connected back to
the Cloud Node, access the configuration software as instructed in the
programming manual. This manual is available for download through the
Partner Portal at www.prodatakey.com/pdkio
Reader Compatibility - ProdataKey does not require proprietary readers.
Door controllers accept a wiegand input, including biometric readers and
keypads. OSDP readers are supported by using included jumper (see OSDP
reference guide). Contact support for details.
UL 294 Compliance - All equipment must meet appropriate UL certifications.
For UL listed installations, all cable runs must be less than 30 meters (98.5’)
Part Number - R2
PDK Technical Support
Phone: 801.317.8802 option #2
Email: support@prodatakey.com
PDK Knowledge Base: prodatakey.zendesk.com
www.prodatakey.com
801.317.8802
REV 01142022
View the user manual here:
prodatakey.zendesk.com
PN:R2
Copyright © 2022 ProdataKey Inc. All rights reserved. Pdk, Pdk io, and
the Red logos are trademarkes of ProdataKey Inc.
Quick Start Guide