3. Reader Connection
2. Mounting Controller
6. Locking Relay
5. Input B / REX Connection4. Input A / DPS Connection
1. Package Contents
Jumpers (4)
Diodes (2)
Red Gate Controller (1)
Battery Leads (1)
Enclosure Screws (4)
Mount - Mount the Red Gate enclosure securely to a wall.
+
-
0 1 L +
-
0 1 L
A
-
B A
-
B NC NOCNC NOC 12VDC
+GND
OSDP
OSDP
PORT1
BUS
+-
PORT2
BUS
+-
ETHERNET
POWER
HEART
LINK
ACTIVITY
BATTERY
POE IN
POE OUT
AReader - The reader is mounted at the door with a 22/5 or 22/6 wire running
to the door controller. Wire the reader to the controller as shown above. Be
sure to check polarity and voltage prior to powering the controller.
CPiezo - Can be connected to available relay and configured with software
BOSDP - Place jumper(s) to enable OSDP (see reference guide for more
information about OSDP.)
OSDP Wiring
C
+
-
0 1 L +
-
0 1 L
A
-
B A
-
B NC NOCNC NOC 12VDC
+GND
OSDP
OSDP
PORT1
BUS
+-
PORT2
BUS
+-BATTERY
AReader
Red Gate Controller
B
B
+
-
0 1 L +
-
0 1 L
A
-
B A
-
B NC NOCNC NOC 12VDC
+GND
OSDP
OSDP
PORT1
BUS
+-
PORT2
BUS
+-BATTERY
ADPS (Door Position Sensor) - The DPS is mounted on the door frame with a
22/2 wire running from the DPS to the controller. Wire the DPS to the
controller as shown above. For reporting double doors, wire the two door
position in series and connect to the controller.
B
AUX Input - A software rule can be programmed to trigger events or
outputs based on input triggers.
B
A
-
B
Double
DPS Contact
A
DPS Contact
+
-
0 1 L +
-
0 1 L
A
-
B A
-
B NC NOCNC NOC 12VDC
+GND
OSDP
OSDP
PORT1
BUS
+-
PORT2
BUS
+-BATTERY
If using a powered REX,
run to any 12VDC
output on controller.
BREX Maglock
A
C
PORT1
BUS
+-
D
Maglock - When installing a Maglock, it is typical to install a REX (request to
exit) at the door for free egress. Run an 18/2 wire from the maglock to the
controller and REX as shown.
REX (Request to Exit) - The REX is mounted at your desired location with an
18/5 wire. Wire the REX to the controller and maglock as shown above. If
reporting is not needed in the system, simply eliminate the green input wire.
A
B
Jumper Block - Use to designated (+) or (-) board voltage out of NO and NC.
If the jumper is off, the relay is a standard dry contact requiring an input into
C on the relay.
C
DAUX Input - A software rule can be programmed to trigger events or outputs
based on input triggers.
Gate Operator - Follow the gate operator wiring instructions to connect the
gate operator to an ELK 912B Isolation Relay.
Isolation Relay - Installation of an ELK 912B isolation relay is recommended
to prevent electrical damage to the Red Gate, The isolation relay is
sold separately.
Locking Relay - Connect the ELK 912B isolation relay to the controller by
connecting the positive wire into a positive port and the negative wire into
the NO port on the board.
Jumper Block - Use to designated (+) or (-) board volatage out of NO and NC.
If the jumper is off, the relay is a standard dry contact requiring an input into
C on the relay negative (-) and center pins.
+
-
0 1 L +
-
0 1 L
A
-
B A
-
B NC NOCNC NOC 12VDC
+GND
OSDP
OSDP
PORT1
BUS
+-
PORT2
BUS
+-BATTERY
C
A
D
B
NO NO
COM
D2
Wiring from Gate Operator
-
+
PORT1
BUS
+-
ELK 912B
Isolation Relay
(sold separately)
A
B
C
D
Reference Guide
8. Power Connection
OSDP Reference Guide
7. Communication Connections
Ethernet - All Red controllers come with a built-in RJ45 connection for
network connectivity. Once connected, the Red Gate controller is
Self-Discoverable from pdk.io using IPV6. Alternatively, you may use IPV4
or assign a static IP using pdk.io if desired.
A
+
-
0 1 L +
-
0 1 L
A
-
B A
-
B NC NOCNC NOC 12VDC
+GND
OSDP
OSDP
PORT1
BUS
+-
PORT2
BUS
+-
ETHERNET
POWER
HEART
LINK
ACTIVITY
BATTERY
POE IN
POE OUT
A
DC INPUT - Input 12-24 VDC power using an 18/2 wire. For high voltage
applications, use the High Voltage Converter (PN: HVC).
BATTERY - The enclosure will fit most 12 VDC 1.2 Ah batteries. Connect the
battery to the controller using the supplied battery leads.
A
B
0 1 L +
-
0 1 L
A
-
B A
-
B NC NOCNC NOC 12VDC
+GND
OSDP
OSDP
PORT1
BUS
+-
PORT2
BUS
+-BATTERY
A
B
Battery
12 VDC / 1.2 Ah
What is OSDP - Open Supervised Device Protocol (OSDP) is an access control
communications standard developed by the Security Industry Association to
improve interoperability among access control and security products. OSDP
brings heightened security and improved functionality. It is more secure than
Wiegand and supports AES-128 encryption.
OSDP Wire Specication - Four-conductor twisted-pair with overall shield is
recommended to remain fully TIA-485 compliant at the maximum supported
baud rates and cable distances.
NOTE - It’s possible to reuse existing Wiegand wiring for OSDP, however, using
simple stranded cable typical of Wiegand readers generally does not meet the
RS485 twisted pair recommendations.
OSDP Multi-Drop - Multi-drop gives you the capability to accommodate
many readers by running one length of four-conductor cable, eliminating the
need to run wire for each wire.
NOTE - The maximum number of readers each port can support is four.
NOTE - Wiegand readers will not work when OSDP jumpers are installed.
Fire Input - To integrate the fire system into a controller, refer to wiring
diagrams at www.prodatakey.zendesk.com
Programming - After the controller is connected, access the configuration
software as instructed in the programming manual availabe at
www.prodatakey.zendesk.com
Reader Compatibility - Pdk does not require proprietary readers.
Controllers accept a Wiegand input, including biometric readers and
keypads. OSDP readers are supported by using included jumper (see OSDP
reference guide). Contact pdk support if assistance is needed.
UL 294 Compliance - All equipment must meet appropriate UL certifications.
For UL listed installations, all cable runs must be less than 30 meters (98.5’)
Part Number - RGE
PDK Technical Support
Phone: 801.317.8802 option #2
Email: support@prodatakey.com
PDK Knowledge Base: www.prodatakey.zendesk.com www.prodatakey.com
801.317.8802
REV 06032022
View the user manual here:
prodatakey.zendesk.com
PN:RGE
Copyright © 2022 ProdataKey Inc. All rights reserved. Pdk, Pdk io, and
the Red logos are trademarkes of ProdataKey Inc.
Quick Start Guide
gate
outdoor controller
ethernet

Other PDK Controllers manuals

PDK Red 1 User manual

PDK

PDK Red 1 User manual

PDK RED 2 User manual

PDK

PDK RED 2 User manual

PDK Red 1 User manual

PDK

PDK Red 1 User manual

PDK Red 4 User manual

PDK

PDK Red 4 User manual

PDK Red 2 User manual

PDK

PDK Red 2 User manual

PDK Red gate RGE User manual

PDK

PDK Red gate RGE User manual

PDK Red Pedestal RPE User manual

PDK

PDK Red Pedestal RPE User manual

PDK Red 8 User manual

PDK

PDK Red 8 User manual

PDK Red 2 User manual

PDK

PDK Red 2 User manual

Popular Controllers manuals by other brands

Honeywell Excel 10 installation instructions

Honeywell

Honeywell Excel 10 installation instructions

National Instruments PXIe-8840 Quad-Core user manual

National Instruments

National Instruments PXIe-8840 Quad-Core user manual

Sunricher SR-2411-ZG manual

Sunricher

Sunricher SR-2411-ZG manual

Nevco 816 Operator instructions

Nevco

Nevco 816 Operator instructions

Sealey ELECTROSTART E/START3012 instructions

Sealey

Sealey ELECTROSTART E/START3012 instructions

Lintec MC-7000D Series instruction manual

Lintec

Lintec MC-7000D Series instruction manual

3Ware 9550SXU-16ML - Sata Rohs user guide

3Ware

3Ware 9550SXU-16ML - Sata Rohs user guide

Allen-Bradley PowerFlex 4 user manual

Allen-Bradley

Allen-Bradley PowerFlex 4 user manual

Tews Technologies TPMC821-SW-42 user manual

Tews Technologies

Tews Technologies TPMC821-SW-42 user manual

Frigicoll Kaysun KWF 140 ACS owner's manual

Frigicoll

Frigicoll Kaysun KWF 140 ACS owner's manual

Nidec LEROY-SOMER Digistart D5 user guide

Nidec

Nidec LEROY-SOMER Digistart D5 user guide

PXM LED driver 3x6A/OC user manual

PXM

PXM LED driver 3x6A/OC user manual

Vimar BY-ALARM PLUS 03824 quick start guide

Vimar

Vimar BY-ALARM PLUS 03824 quick start guide

Carel ADCD000110 quick start guide

Carel

Carel ADCD000110 quick start guide

Flybox EFC-P user manual

Flybox

Flybox EFC-P user manual

Renishaw UCC T5 installation guide

Renishaw

Renishaw UCC T5 installation guide

Linear Technology LTC1877 Demo Manual

Linear Technology

Linear Technology LTC1877 Demo Manual

TTL UBT eQo user manual

TTL

TTL UBT eQo user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.