Pentair FLECK SXT User manual

FLECK SXT TIMER
SERVICE MANUAL
waterpurification.pentair.com

TABLE OF CONTENTS
TABLE OF CONTENTS..........................................................2
JOB SPECIFICATION SHEET................................................2
California Proposition 65 Warning.......................................2
TIMER FEATURES ................................................................3
TIMER OPERATION ..............................................................4
MASTER PROGRAMMING MODE CHART ............................5
MASTER PROGRAMMING MODE.........................................6
MASTER PROGRAMMING MODE
continued ........................................ 7
MASTER PROGRAMMING MODE
continued ........................................ 8
USER PROGRAMMING MODE..............................................9
DIAGNOSTIC PROGRAMMING MODE ................................10
2510/2750/2850S TIMER ASSEMBLY................................. 11
9000/9100/9500 TWIN TANK TIMER ASSEMBLY ...............12
3/4-INCH PLASTIC TURBINE METER ASSEMBLY.............13
PLASTIC PADDLE METER ASSEMBLY............................... 14
3/4-INCH BRASS PADDLE METER ASSEMBLY .................15
1-INCH BRASS PADDLE METER ASSEMBLY ....................16
1-INCH STAINLESS STEEL METER ASSEMBLY ................ 17
INLINE PLASTIC TURBINE METER ASSEMBLY ................18
1-1/2 INCH BRASS METER ASSEMBLY ............................19
1-1/2 INCH STAINLESS STEEL METER ASSEMBLY ..........20
3/4-INCH, 1-INCH or 1-1/2 INCH PADDLE WHEEL METER
CAP ASSEMBLY.................................................................. 21
TROUBLESHOOTING.......................................................... 22
2510SXT WIRING DIAGRAM...............................................23
2750SXT/2850SXT WIRING DIAGRAM................................24
9000SXT/9100SXT/9500SXT WIRING DIAGRAM ................25
SERVICE ASSEMBLIES ......................................................26
JOB SPECIFICATION SHEET
Job Number: ______________________________________________
Model Number:____________________________________________
Water Hardness: __________________________________ ppm or gpg
Capacity Per Unit:__________________________________________
Mineral Tank Size: ___________ Diameter: ________Height:________
Salt Setting per Regeneration:________________________________
1. Type of Timer:
A. 7 Day or 12 Day
B. Meter Initiated
2. Downflow: Upflow Upflow Variable
3. Meter Size:
A. 3/4-inch Turbine
B. 3/4-inch Paddlewheel
C. 1-inch Turbine
D. 1-inch Paddlewheel
E. 1-1/2 inch Turbine
F. 1-1/2 inch Paddlewheel
G. Generic ______Pulse Count _______ Model ____________
4. System Type:
A. System #4: 1 Tank, 1 Meter, Immediate, or
Delayed Regeneration
B. System #4: Time Clock
C. System #4: Twin Tank
5. Timer Program Settings:
A. Backwash:______________________________ Minutes
B. Brine and Slow Rinse:_____________________ Minutes
C. Rapid Rinse: ____________________________ Minutes
D. Brine Tank Refill: ________________________ Minutes
E. Pause Time: ____________________________ Minutes
F. Second Backwash: _______________________ Minutes
6. Drain Line Flow Control: gpm
7. Brine Line Flow Controller: gpm
8. Injector Size#:
9. Piston Type:
A. Hard Water Bypass
B. No Hard Water Bypass
CALIFORNIA PROPOSITION 65 WARNING
WARNING:
This product contains chemicals known to
the State of California to cause cancer or
birth defects or other reproductive harm.
2• FLECK SXT Timer Service Manual

TIMER FEATURES
Parameter
Display
Data
Display
PM
Indicator
Flow Indicator
x1000 Indicator
Service
Icon
Programming
Icon
Extra Cycle
Button
Up
Button
Down
Button
Error/
Information
Icon
Figure 1
Features of the SXT:
• Power backup that continues to keep time and the
passage of days for a minimum of 48 hours in the event
of power failure. During a power outage, the control
goes into a power-saving mode. It does not monitor
water usage during a power failure, but it does store the
volume remaining at the time of power failure.
• Settings for both valve (basic system) and control type
(method used to trigger a regeneration).
• Day-of-the-Week controls.
• While in service, the display alternates between time of
day, volume remaining or days to regeneration, and tank
in service (twin tank systems only).
• The Flow Indicator flashes when outlet flow is detected.
• The Service Icon flashes if a regeneration cycle has
been queued.
• A Regeneration can be triggered immediately by
pressing the Extra Cycle button for five seconds.
• The Parameter Display displays the current Cycle Step
(BW, BF, RR, etc) during regeneration, and the data
display counts down the time remaining for that cycle
step. While the valve is transferring to a new cycle step,
the display will flash. The parameter display will identify
the destination cycle step (BW, BF, RR, etc) and the data
display will read “----”. Once the valve reaches the cycle
step, the display will stop flashing and the data display
will change to the time remaining. During regeneration,
the user can force the control to advance to the next
cycle step immediately by pressing the extra
cycle button.
Setting the Time of Day
1. Press and hold either the Up or Down buttons until the
programming icon replaces the service icon and the
parameter display reads TD.
2. Adjust the displayed time with the Up and Down buttons.
3. When the desired time is set, press the Extra Cycle button
to resume normal operation. The unit will also return to
normal operation after 5 seconds if no buttons are pressed.
Queueing a Regeneration
1. Press the Extra Cycle button. The service icon will flash to
indicate that a regeneration is queued.
2. To cancel a queued regeneration, press the Extra
Cycle button.
Regenerating Immediately
Press and hold the Extra Cycle button for five seconds.
42637 Rev D
FLECK SXT Timer Service Manual • 3

TIMER OPERATION
Meter Immediate Control
A meter immediate control measures water usage and
regenerates the system as soon as the calculated system
capacity is depleted. The control calculates the system
capacity by dividing the unit capacity (typically expressed
in grains/unit volume) by the feedwater hardness and
subtracting the reserve. Meter Immediate systems
generally do not use a reserve volume. However, in twin
tank systems with soft-water regeneration, the reserve
capacity should be set to the volume of water used during
regeneration to prevent hard water break-through. A Meter
Immediate control will also start a regeneration cycle at the
programmed regeneration time if a number of days equal
to the regeneration day override pass before water usage
depletes the calculated system capacity.
Meter Delayed Control
A Meter Delayed Control measures water usage and
regenerates the system at the programmed regeneration
time after the calculated system capacity is depleted. As
with Meter Immediate systems, the control calculates the
system capacity by dividing the unit capacity by the feedwater
hardness and subtracting the reserve. The reserve should be
set to insure that the system delivers treated water between
the time the system capacity is depleted and the actual
regeneration time. A Meter Delayed control will also start a
regeneration cycle at the programmed regeneration time if a
number of days equal to the regeneration day override pass
before water usage depletes the calculated system capacity.
Time Clock Delayed Control
A Time Clock Delayed Control regenerates the system on a
timed interval. The control will initiate a regeneration cycle
at the programmed regeneration time when the number of
days since the last regeneration equals the regeneration day
override value.
Day of the Week Control
This control regenerates the system on a weekly schedule.
The schedule is defined in Master Programming by setting
each day to either “off” or “on.” The control will initiates a
regeneration cycle on days that have been set to “on” at the
specified regeneration time.
Control Operation During Regeneration
During regeneration, the control displays a special
regeneration display. In this display, the control shows the
current regeneration step number the valve is advancing
to, or has reached, and the time remaining in that step.
The step number that displays flashes until the valve
completes driving to this regeneration step position. Once all
regeneration steps are complete the valve returns to service
and resumes normal operation.
Pressing the Extra Cycle button during a regeneration cycle
immediately advances the valve to the next cycle step position
and resumes normal step timing.
Control Operation During Programming
The control only enters the Program Mode with the valve in
service. While in the Program Mode, the control continues
to operate normally monitoring water usage and keeping
all displays up to date. Control programming is stored in
memory permanently, eliminating the need for battery
backup power.
Manually Initiating a Regeneration
1. When timer is in service, press the Extra Cycle button for
5 seconds on the main screen.
2. The timer advances to Regeneration Cycle Step #1
(Backwash), and begins programmed time count down.
3. Press the Extra Cycle button once to advance valve to
Regeneration Cycle Step #2 (Brine Draw/Rinse).
4. Press the Extra Cycle button once to advance valve to
Regeneration Cycle Step #3 (Rapid rinse).
5. Press the Extra Cycle button once to advance valve to
Regeneration Cycle Step #4 (Brine Refill).
6. Press the Extra Cycle button once more to advance the
valve back to in service.
NOTE: If the unit is a filter or upflow, the cycle step order
may change.
NOTE: A queued regeneration can be initiated by
pressing the Extra Cycle button. To clear a queued
regeneration, press the Extra Cycle button again
to cancel. If regeneration occurs for any reason
prior to the delayed regeneration time, the manual
regeneration request shall be cleared.
Control Operation During A Power Failure
The SXT includes integral power backup. In the event of power
failure, the control shifts into a power-saving mode. The control
stops monitoring water usage, and the display and motor shut
down, but it continues to keep track of the time and day for a
minimum of 48 hours.
The system configuration settings are stored in a non-volatile
memory and are stored indefinitely with or without line power.
The Time of Day flashes when there has been a power failure.
Press any button to stop the Time of Day from flashing.
If power fails while the unit is in regeneration, the control will
save the current valve position before it shuts down. When
power is restored, the control will resume the regeneration
cycle from the point where power failed. Note that if power fails
during a regeneration cycle, the valve will remain in it’s current
position until power is restored. The valve system should
include all required safety components to prevent overflows
resulting from a power failure during regeneration.
The control will not start a new regeneration cycle without
line power. If the valve misses a scheduled regeneration due
to a power failure, it will queue a regeneration. Once power is
restored, the control will initiate a regeneration cycle the next
time that the Time of Day equals the programmed regeneration
time. Typically, this means that the valve will regenerate one
day after it was originally scheduled. If the treated water
output is important and power interruptions are expected, the
system should be setup with a sufficient reserve capacity to
compensate for regeneration delays.
4• FLECK SXT Timer Service Manual

MASTER PROGRAMMING MODE CHART
CAUTION
Before entering Master Programming, please contact your local professional water dealer. To enter Master
Programming, set time to 12:01 PM.
Master Programming Options
Abbreviation Parameter Option
Abbreviation
Options
DF Display Format GAL Gallons
Ltr Liters
VT Valve Type
dF1b Downflow/Upflow Single Backwash
dF2b Downflow Double Backwash
Fltr Filter
UFbd Upflow Brine First
UFtr Upflow Filter
Othr Other
CT Control Type
Fd Meter (Flow) Delayed
FI Meter (Flow) Immediate
tc Time Clock
dAY Day of Week
NT Number of Tanks 1 Single Tank System
2 Two Tank System
TS Tank in Service
U1 Tank 1 in Service
U2 Tank 2 in Service
C Unit Capacity Unit Capacity (Grains)
H Feedwater Hardness Hardness of Inlet Water
RS Reserve Selection SF Percentage Safety Factor
rc Fixed Reserve Capacity
SF Safety Factor Percentage of the system capacity to be used as a reserve
RC Fixed Reserve Capacity Fixed volume to be used as a reserve
DO Day Override The system’s day override setting
RT Regen Time The time of day the system will regenerate
BW, BD, RR, BF Regen Cycle Step
Times
The time duration for each regeneration step. Adjustable from
OFF and 0-199 minutes.
NOTE: If “Othr” is chosen under “Valve Type”, then R1, R2,
R3, etc, will be displayed instead
D1, D2, D3, D4, D5,
D6, & D7 Day of Week Settings Regeneration setting (On or OFF) for each day of the week on
day-of-week systems
CD Current Day The Current day of the week
FM Flow Meter Type
t0.7 3/4-inch Turbine Meter
P0.7 3/4-inch Paddle Wheel Meter
t1.0 1-inch Turbine Meter
P1.0 1-inch Paddle Wheel Meter
t1.5 1.5-inch Turbine Meter
P1.5 1.5-inch Paddle Wheel Meter
P2.0 2-inch Paddle Wheel Meter
Gen Generic or Other Meter
K Meter Pulse Setting Meter pulses per gallon for generic/other flow meter
NOTE: Some items may not be shown depending on timer configuration. The timer will discard any changes and exit Master
Programming Mode if any button is not pressed for sixty seconds.
FLECK SXT Timer Service Manual • 5

MASTER PROGRAMMING MODE
When the Master Programming Mode is entered, all
available option setting displays may be viewed and set
as needed. Depending on current option settings, some
parameters cannot be viewed or set.
Setting the Time of Day
1. Press and hold either the Up or Down buttons until the
programming icon replaces the service icon and the
parameter display reads TD.
2. Adjust the displayed time with the Up and Down buttons.
3. When the desired time is set, press the Extra Cycle
button to resume normal operation. The unit will also
return to normal operation after 5 seconds if no buttons
are pressed.
Entering Master Programming Mode
Set the Time Of Day display to 12:01 P.M. Press the Extra
Cycle button (to exit Setting Time of Day mode). Then
press and hold the Up and Down buttons together until the
programming icon replaces the service icon and the Display
Format screen appears.
Exiting Master Programming Mode
Press the Extra Cycle button to accept the displayed settings
and cycle to the next parameter. Press the Extra Cycle
button at the last parameter to save all settings and return
to normal operation. The control will automatically disregard
any programming changes and return to normal operation if
it is left in Master Programming mode for 5 minutes without
any keypad input.
Resets
Soft Reset: Press and hold the Extra Cycle and Down buttons
for 25 seconds while in normal Service mode. This resets all
parameters to the system default values, except the volume
remaining in meter immediate or meter delayed systems
and days since regeneration in the time clock system.
Master Reset: Hold the Extra Cycle button while powering up
the unit. This resets all of the parameters in the unit. Enter
Master Programming and reprogram the unit.
1. Display Format (Display Code DF)
This is the first screen that appears when entering Master
Programming Mode. The Display Format setting specifies
the unit of measure that will be used for volume and how
the control will display the Time of Day. This option setting is
identified by “DF” in the upper left hand corner of the screen.
There are three possible settings:
Display Format Setting Unit of Volume Time Display
GAL U.S. Gallons 12-Hour AM/PM
Ltr Liters 24-Hour
2. Valve Type (Display Code VT)
Press the Extra Cycle button. Use this display to set the Valve
Type. The Valve Type setting specifies the type of cycle that the
valve follows during regeneration. Note that some valve types
require that the valve be built with specific subcomponents.
Ensure the valve is configured properly before changing the
Valve Type setting. This option setting is identified by “VT” in
the upper left hand corner of the screen. There are
six possible settings:
Abbreviation Parameter
dF1b Downflow/Upflow, Single Backwash
dF2b Downflow, Double Backwash
Fltr Filter
UFbd Upflow Brine First
UFtr Upflow Filter
Othr Other
3. Control Type (Display Code CT)
Press the Extra Cycle button. Use this display to set the Control
Type. This specifies how the control determines when to trigger
a regeneration. For details on how the various options function,
refer to the “Timer Operation” section of this service manual.
This option setting is identified by “CT” in the upper left hand
corner of the screen. There are four possible settings:
Meter Delayed: Fd
Meter Immediate: FI
Time Clock: tc
Day of Week: dAY
4. Number of Tanks (Display Code NT)
Press the Extra Cycle button. Use this display to set the
Number of Tanks in your system. This option setting is
identified by “NT” in the upper left hand corner of the screen.
There are two possible settings:
Single Tank System: 1
Two-Tank System: 2
6• FLECK SXT Timer Service Manual

5. Tank in Service (Display Code TS)
Press the Extra Cycle button. Use this display to set whether
tank one or tank two is in service. This option setting is
identified by “TS” in the upper left hand corner of the screen.
This parameter is only available if the number of tanks has
been set to 2. There are two possible settings:
Tank One in Service: U1
Tank Two in Service: U2
6. Unit Capacity (Display Code C)
Press the Extra Cycle button. Use this display to set the
Unit Capacity. This setting specifies the treatment capacity
of the system media. Enter the capacity of the media bed
in grains of hardness when configuring a softener system,
and in the desired volume capacity when configuring a filter
system. This option setting is identified by “C” in the upper
left hand corner of the screen. The Unit Capacity parameter
is only available if the control type has been set to one of the
metered options. Use the Up and Down buttons to adjust the
value as needed.
Range: 1-999,900 gallons (100-9,999,000 Liters)
7. Feedwater Hardness (Display Code H)
Press the Extra Cycle button. Use this display to set the
Feedwater Hardness. Enter the feedwater hardness in grains
per unit volume for softener systems, or 1 for filter systems.
This option setting is identified by “H” in the upper left hand
corner of the screen. The feedwater hardness parameter is
only available if the control type has been set to one of the
metered options. Use the Up and Down buttons to adjust the
value as needed.
Range: 1-199 hardness
8. Reserve Selection (Display Code RS)
Press the Extra Cycle button. Use this display to set the Safety
Factor. Use this display to select the type of reserve to be
used in your system. This setting is identified by “RS” in the
upper left-hand corner of the screen. The reserve selection
parameter is only available if the control type has been set to
one of the metered options. There are two possible settings.
FS Safety Factor
rc Fixed Reserve Capacity
9. Safety Factor (Display Code SF)
Press the Extra Cycle button. Use this display to set the Safety
Factor. This setting specifies what percentage of the system
capacity will be held as a reserve. Since this value is expressed
as a percentage, any change to the unit capacity or feedwater
hardness that changes the calculated system capacity will
result in a corresponding change to the reserve volume.This
option setting is identified by “SF” in the upper left hand corner
of the screen. Use the Up and Down buttons to adjust the value
from 0 to 50% as needed.
Range: 0-50%
10. Fixed Reserve Capacity (Display Code RC)
Press the Extra Cycle button. Use this display to set the
Reserve Capacity. This setting specifies a fixed volume that
will be held as a reserve. The reserve capacity cannot be set
to a value greater than one-half of the calculated system
capacity. The reserve capacity is a fixed volume and does not
change if the unit capacity or feedwater hardness are changed.
This option setting is identified by “RC” in the upper left-hand
corner of the screen. Use the Up and Down buttons to adjust
the value as needed.
Range: 0-half the calculated capacity
MASTER PROGRAMMING MODE
CONTINUED
FLECK SXT Timer Service Manual • 7

11. Day Override (Display Code DO)
Press the Extra Cycle button. Use this display to set the
Day Override. This setting specifies the maximum number
of days between regeneration cycles. If the system is set to
a timer-type control, the day override setting determines
how often the system will regenerate. A metered system
will regenerate regardless of usage if the days since last
regeneration cycle equal the day override setting. Setting
the day override value to “OFF” disables this function. This
option setting is identified by “DO” in the upper left hand
corner of the screen. Use the Up and Down buttons to adjust
the value as needed.
Range: Off-99 days
12. Regeneration Time
Press the Extra Cycle button. Use this display to set the
Regeneration Time. This setting specifies the time of day
the control will initiate a delayed, manually queued, or
day override triggered regeneration. This option setting is
identified by “RT” in the upper left hand corner of the screen.
Use the Up and Down buttons to adjust the value as needed.
13. Regeneration Cycle Step Times
Press the Extra Cycle button. Use this display to set
the Regeneration Cycle Step Times. The different
regeneration cycles are listed in sequence based on the
valve type selected for the system, and are identified by an
abbreviation in the upper left-hand corner of the screen. The
abbreviations used are listed below. If the system has been
configured with the “OTHER” valve type, the regeneration
cycles will be identified as R1, R2, R3, R4, R5, and R6. Each
cycle step time can be set from 0 to 199 minutes. Setting a
cycle step time to 0 will cause the control to skip that step
during regeneration, but keeps the following steps available.
Use the Up and Down buttons to adjust the value as needed.
Press the Extra Cycle button to accept the current setting
and move to the next parameter.
Abbreviation Cycle Step
BD Brine Draw
BF Brine Fill
BW Backwash
RR Rapid Rinse
SV Service
Range: 0-199 minutes
MASTER PROGRAMMING MODE
CONTINUED
14. Day of Week Settings
Press the Extra Cycle button. Use this display to set the
regeneration schedule for a system configured as a Day of
Week control. The different days of the week are identified as
D1, D2, D3, D4, D5, D6, and D7 in the upper left-hand corner of
the display. Set the value to “ON” to schedule a regeneration or
“OFF” to skip regeneration for each day. Use the Up and Down
buttons to adjust the setting as needed. Press the Extra Cycle
button to accept the setting and move to the next day. Note that
the control requires at least one day to be set to “ON.” If all 7
days are set to “OFF”, the unit will return to Day One until one
or more days are set to “ON.”
15. Current Day (Display Code CD)
Press the Extra Cycle button. Use this display to set the current
day on systems that have been configured as Day of Week
controls. This setting is identified by “CD” in the upper left-
hand corner of the screen. Use the Up and Down buttons to
select from Day 1 through Day 7.
16. Flow Meter Type (Display Code FM)
Press the Extra Cycle button. Use this display to set the type
of flow meter connected to the control. This option setting is
identified by “FM” in the upper left-hand corner of the screen.
Use the Up and Down buttons to select one of the seven available
settings.
t0.7 Fleck 3/4-inch Turbine Meter
P0.7 Fleck 3/4-inch Paddle Wheel Meter
t1.0 Fleck 1-inch Turbine Meter
P1.0 Fleck 1-inch Paddle Wheel Meter
t1.5 Fleck 1-1/2 inch Turbine Meter
P1.5 Fleck 1-1/2 inch Paddle Wheel Meter
P2.0 Fleck 2-inch Paddle Wheel Meter
GEn Generic/Other Meter
17. Meter Pulse Setting (Display Code K)
Press the Extra Cycle button. Use this display to specify the
meter pulse setting for a non-standard flow meter. This option
setting is identified by “K” in the upper left-hand corner of
the screen. Use the Up and Down buttons to enter the meter
constant in pulses per unit volume.
18. End of Master Programming Mode
Press the Extra Cycle button to save all settings and exit
Master Programming Mode.
8• FLECK SXT Timer Service Manual

USER PROGRAMMING MODE
User Programming Mode Options
Abbreviation Parameter Description
DO Day Override The timer’s day override
setting
RT Regeneration
Time
The time of day that the
system will regenerate
(meter delayed, timeclock,
and day-of-week systems)
H Feed Water
Hardness
The hardness of the inlet
water - used to calculate
system capacity for metered
systems
RC or SF Reserve Capacity The fixed reserve capacity
CD Current Day The current day of week
NOTE: Some items may not be shown depending on timer
configuration. The timer will discard any changes
and exit User Mode if any button is not pressed for
sixty seconds.
User Programming Mode Steps
1. Press the Up and Down buttons for five seconds while in
service, and the time of day is NOT set to 12:01 PM.
2. Use this display to adjust the Day Override. This option
setting is identified by “DO” in the upper left hand corner
of the screen.
3. Press the Extra Cycle button. Use this display to adjust
the Regeneration Time. This option setting is identified by
“RT” in the upper left hand corner of the screen.
4. Press the Extra Cycle button. Use this display to adjust
the Feed Water Hardness. This option setting is identified
by “H” in the upper left hand corner of the screen.
Range: 1-199 hardness
5. Press the Extra Cycle button. Use this display to adjust the
Fixed Reserve Capacity. This option setting is identified by
“RC” or "SF" in the upper left-hand Corner
of the screen.
6. Press the Extra Cycle button. Use this display to set the
Current Day of the Week. This option setting is identified by
“CD” in the upper left hand corner of the screen.
7. Press the Extra Cycle button to end User
Programming Mode.
FLECK SXT Timer Service Manual • 9

DIAGNOSTIC PROGRAMMING MODE
Diagnostic Programming Mode Options
Abbreviation Parameter Description
FR Flow Rate Displays the current outlet flow
rate
PF Peak Flow
Rate
Displays the highest flow
rate measured since the last
regeneration
HR Hours in
Service
Displays the total hours that the
unit has been in service
VU Volume
Used
Displays the total volume of
water treated by the unit
RC Reserve
Capacity
Displays the system’s reserve
capacity calculated from the
system capacity, feedwater
hardness, and safety factor
SV Software
Version
Displays the software version
installed on the controller
NOTE: Some items may not be shown depending on timer
configuration. The timer will exit Diagnostic Mode
after 60 seconds if no buttons are pressed. Press the
Extra Cycle button to exit Diagnostic Mode at
any time.
Diagnostic Programming Mode Steps
1. Press the Up and Extra Cycle buttons for five seconds
while in service.
2. Use this display to view the current Flow Rate. This option
setting is identified by “FR” in the upper left hand corner
of the screen.
3. Press the Up button. Use this display to view the Peak
Flow Rate since the last regeneration cycle. This option
setting is identified by “PF” in the upper left hand corner
of the screen.
4. Press the Up button. Use this display to view the Hours
in Service since the last regeneration cycle. This option
setting is identified by “HR” in the upper left hand corner
of the screen.
5. Press the Up button. Use this display to view the Volume
Used since the last regeneration cycle. This option setting
is identified by “VU” in the upper left hand corner
of the screen.
6. Press the Up button. Use this display to view the Reserve
Capacity. This option setting is identified by “RC” in the
upper left hand corner of the screen.
7. Press the Up button. Use this display to view the Software
Version. This option setting is identified by “SV” in the upper
left hand corner of the screen.
8. Press the Extra Cycle button to end Diagnostic
Programming Mode.
10 • FLECK SXT Timer Service Manual

Item No. QTY Part No. Description
1 ..............1...... 13881 ..............Bracket, Hinge Timer
3 ..............1...... 14265 ..............Clip, Spring
4 ..............1...... 27172 ..............Stand-off, Timer, 2510SXT,
2750SXT
5 ..............1...... 21363 ..............Screw, Hex HD, M4 X 12 MM
7 ..............1...... 27168 ..............Bracket, Timer,
2510SE/2750SXT
8 ..............3...... 13296 ..............Screw, Hex Washer,
6-20 X 1/2
9 ..............1...... 42778 ..............Timer, SXT, 2510/2750, DF
9A............1...... 19889 ..............Housing, Circuit Board
9B............1...... 42196..............Circuit Board, SXT
9C............1...... 42635-01.........Cover, Front, SXT, Square
9D............1...... 42637..............Label, Display, SXT
9E............1...... 42864 ..............Wire Harness, SXT
Not Shown:
......................... 42469..............Transformer, US, 120/24V,
40VA, CEC
......................... 41049..............Transformer, Euro, 230/24V,
108VA
......................... 41050..............Transformer, Aust, 230/24V,
108VA
......................... 43340..............Transformer, Japan, 100/24V,
40 VA
2510/2750/2850S TIMER ASSEMBLY
42778 Rev E
9
3 4
1
2
7
5
9A
9B
9C 9D
8
9E
FLECK SXT Timer Service Manual • 11

9000/9100/9500 TWIN TANK TIMER
ASSEMBLY
Item No. QTY Part No. Description
1 ..............1...... 13881 ..............Bracket, Hinge Timer
2 ..............2...... 11384 ..............Screw, Phillips, 6-32 X 1/4
3 ..............1...... 42732 ..............Bracket, Timer, 9000SXT
4 ..............2...... 13296 ..............Screw, Hex Washer Hd,
6-20 X 1/2
5 ..............1...... 14265 ..............Clip, Spring
6 ..............1...... 42733 ..............Stand-off, Timer, 9000SXT
7 ..............1...... 42777 ..............Timer, SXT, D/F, 9000/9100/9500
7A............1...... 19889 ..............Housing, Circuit Board
7B............1...... 42196..............Circuit Board, SXT
7C............1...... 42635-01.........Cover, Front, SXT, Square
7D............1...... 42637..............Label, Display, SXT
8 ..............1...... 19474-01.........Harness, SXT
Not Shown:
......................... 19674..............Transformer, US, 120/24V, 9.6VA
......................... 41475..............Transformer, Euro, 230/24V, 9.6VA
......................... 43212..............Transformer, Aust, 230/24V, 9.6VA
......................... 43340..............Transformer, Japan, 100/24V,
9.6VA
42777 Rev D
1
2
4
3
5
6
7A
7B
7C
7D
7
8
12 • FLECK SXT Timer Service Manual

3/4-INCH PLASTIC TURBINE METER
ASSEMBLY
19797 Rev A
Item No. QTY Part No. Description
1 ..............1...... 19791-01.........Meter Cable Assembly,
16 inch long with connector
2 ..............2...... 19569 ..............Clip, Flow Meter
3 ..............2...... 13314 ..............Screw, Slot Ind Hex,
8-18 x .60
4 ....................... 19797..............Meter, 3/4" Turbine, No Clips/Screws
5 ....................... 60626..............Meter, 3/4" Turbine, with Clips/Screws
5
4
FLECK SXT Timer Service Manual • 13

PLASTIC PADDLE METER ASSEMBLY
Item No. QTY Part No. Description
1 ..............1...... 14716 ..............Meter Cap Assy, NT
(includes items 2, 3, and 4)
2 ..............1...... 13874 ..............Cap, Meter, Electronic
3 ..............1...... 13847 ..............O-ring, -137, Std, Meter
4 ..............1...... 17798 ..............Screw, Slot Hex Washer
Head
5 ..............1...... 19121-01.........Meter Cable Assy, SXT,
Paddle (not included in P/N
60086-50)
6 ..............1...... 13821 ..............Body, Meter, 5600
7 ..............1...... 13509 ..............Impeller, Meter
8 ..............4...... 12473 ..............Screw, Hex Wsh, 10-24 x
5/8
9 ..............4...... 13255 ..............Clip, Mounting
10 ............4...... 13314 ..............Screw, Slot Ind Hex, 8-18 x
0.60
11 ............4...... 13305 ..............O-ring, -119
12 ............1...... 14613 ..............Flow Straightener
13 ............1...... 60086-50.........Meter, 3/4", Paddlewheel,
Electronic
5
8
1
2
7
6
9
10
3
4
11
BR60086 Rev E
13
14 • FLECK SXT Timer Service Manual

3/4-INCH BRASS PADDLE METER
ASSEMBLY
Item No. QTY Part No. Description
1 ..............1...... 11206 ..............Gasket, Fitting
2 ..............1...... 13942 ..............Retainer, Nut
3 ..............1...... 11207 ..............Nut, Special, Quick Connect
4 ..............1...... 13906 ..............Body, Meter, 3/4-inch
5 ..............1...... 13509 ..............Impeller, Meter
....... 13509-01.........Impeller, Celcon
6 ..............1...... 13847 ..............O-ring, -137 Std/560CD,
Meter
7 ..............1...... 14716 ..............Meter Cap Assy, ET/NT
8 ..............1...... 12473 ..............Screw, Hex Wsh, 10-24 x 5/8
9 ..............1...... 60618 ..............Meter Assy, 3/4", Brass, Elec,
Paddlewheel
10 ............1...... 19121-01.........Meter Cable Assembly,
18 inch long with connector
1
2
3
4
5
6
7
8
9
10
FLECK SXT Timer Service Manual • 15

12
11
1-INCH BRASS PADDLE METER ASSEMBLY
Item No. QTY Part No. Description
1 ..............1...... 14959 ..............Body, Meter, 2750
2 ..............1...... 13882 ..............Post, Meter Impeller
3 ..............1...... 13509 ..............Impeller, Meter
4 ..............1...... 13847 ..............O-ring, -137, Std/560CD,
Meter
5 ..............1...... 14716 ..............Meter Cap Assy, ET/NT
6 ..............4...... 12112 ..............Screw, Hex Hd Mach,
10-24 x 1/2
7 ..............1...... 14960 ..............Flow Straightener, 1-inch
8 ..............1...... 13287 ..............O-ring, -123
9 ..............1...... 14961 ..............Fitting, 1-inch Quick Connect
10 ............1...... 14962 ..............Nut, 1-inch Meter, Quick
Connect
11 ............1...... 60613 ..............Meter Assy, 1", Brass, Elec,
Paddlewheel
12 ............1...... 19121 ..............Meter Cable Assembly,
....... 19121-08.........Meter Cable Assembly,
35 inch long with connector
....... 19121-09.........Meter Cable Assembly,
100 inch long with connector
....... 19121-10.........Meter Cable Assembly
304 inch long with connector
16 • FLECK SXT Timer Service Manual

1-INCH STAINLESS STEEL METER ASSEMBLY
Item No. QTY Part No. Description
1 ..............1...... 62049-01.........Service Kit,
1 inch & 1-1/2 inch Meter,
Standard Range
1 ...... 62049-02.........Service Kit,
1 inch & 1-1/2 inch Meter,
Extended Range
2 ..............1...... 61932-10.........Meter Assy, 1 inch, Inline,
Stainless Steel, NPT,
Standard Range
1 ...... 61932-11.........Meter Assy, 1 inch, Inline,
Stainless Steel, NPT,
Extended Range
1 ...... 61932-20.........Meter Assy, 1 inch, Inline,
Stainless Steel, BSP,
Standard Range
1 ...... 61932-21.........Meter Assy, 1 inch, Inline,
Stainless Steel, BSP,
Extended Range
3 ..............1...... 44022 ..............Union, 1 inch, NPT
(Optional on models with
electronic controls)
1 ...... 44023..............Union, 1 inch, BSP
(Optional on models with
electronic controls)
13
2
4
4 ..............1...... 19791 ..............Meter Cable Assembly,
....... 19791-02.........Meter Cable Assembly,
28 inch long with connector
....... 19791-04.........Meter Cable Assembly,
100 inch long with connector
....... 19791-05.........Meter Cable Assembly
304 inch long with connector
Item No. QTY Part No. Description
FLECK SXT Timer Service Manual • 17

INLINE PLASTIC TURBINE METER ASSEMBLY
Item No. QTY Part No. Description
1 ..............1...... 17542 ..............Flow Straightener
2 ..............2...... 40576 ..............Clip, H, Plastic, 7000
3 ..............1...... 40577 ..............Turbine Meter Assy, 7000
4 ..............1...... 41555 ..............Body, Remote Meter
5 ..............2...... 40951 ..............O-ring, -220
6 ..............2...... 40563 ..............Connector, 1-inch NPT,
7000
7 ..............2...... 40563-10.........Connector, 1-inch BSP,
7000
8 ..............2...... 40565 ..............Connector, 1-1/4 inch NPT,
7000
9 ..............2...... 40565-10.........Connector, 1-1/4 inch BSP,
7000
10 ............2...... 41242 ..............Connector, 1-inch &
1-1/4 inch Sweat
11 ............2...... 41243 ..............Connector, 1-1/4 & 1-1/2
inch Sweat
12 ............2...... 41596 ..............Connector, Brass, 1-inch
NPT
13 ............2...... 41596-10.........Connector, Brass, 1-inch
BSP
14 ............2...... 41597 ..............Connector, Brass, 1-1/2
inch NPT
15 ............2...... 41597-10.........Connector, Brass, 1-1/2
inch BSP
Item No. QTY Part No. Description
16
16 ............1...... 19791 ..............Meter Cable Assembly,
....... 19791-02.........Meter Cable Assembly,
28 inch long with connector
....... 19791-04.........Meter Cable Assembly,
100 inch long with connector
....... 19791-05.........Meter Cable Assembly
304 inch long with connector
Not Shown
....... 61560 ..............Meter Assy, 1-1/2", Inln, No Thrd
....... 61560-01.........Meter Assy, 1", NPT, Elec
....... 61560-02.........Meter Assy, 1", Inln, BSP, Elec
....... 61560-03.........Meter Assy, 1-1/4", Inln, NPT, Elec
....... 61560-04.........Meter Assy, 1-1/4", Inln, BSP, Elec
....... 61560-05.........Meter Assy, 1" & 1-1/4", Inln, Sweat
....... 61560-06.........Meter Assy, 1-1/4" & 1-1/2", Inln
....... 61560-07.........Meter Assy, 1", Inln, NPT, Elec
....... 61560-08.........Meter Assy, 1", Inln, BSP, Elec
....... 61560-09.........Meter Assy, 1-1/2" Inln, NPT, Elec
....... 61560-10.........Meter Assy, 1-1/2", Inln, BSP, Elec
....... 61560-11.........Meter Assy, 3/4", Inln, NPT, Elec
....... 61560-12.........Meter Assy, 3/4", Inln, BSP, Elec
....... 61560-13.........Meter Assy, 1-1/2", Inln, NPT
....... 61560-14.........Meter Assy, 1-1/2", Inln, BSP
18 • FLECK SXT Timer Service Manual

1-1/2 INCH BRASS METER ASSEMBLY
Item No. QTY Part No. Description
1 ..............1...... 17569 ..............Body, Meter, 2850/9500
2 ..............1...... 13882 ..............Post, Meter Impeller
3 ..............1...... 13509 ..............Impeller, Meter
1 ...... 13509-01.........Impeller, Celcon, Hot Water
4 ..............1...... 13847 ..............O-Ring, -137, Std/560CD,
Meter
5A............1...... 14038 ..............Meter Cap Assy, STD
Range, Plastic
5B............1...... 15150..............Meter Cap Assy, Ext Range,
Plastic
6 ..............4...... 12112 ..............Screw, Hex Hd Mach, 10-24
x 1/2 18-8 Stainless Steel
7 ..............1...... 17542 ..............Flow Straightener,
1-1/2 inch
8 ..............1...... 12733 ..............O-Ring, -132
9 ..............1...... 17544 ..............Fitting, 1-1/2 inch Quick
Connector
10 ............1...... 17543 ..............Nut, 1-1/2 inch, Q/C
11 ..................... 60610-01.........Meter Assy, 1-1/2 inch, NPT,
STD, Brass, Paddlewheel
....... 60610-01NP....Meter Assy, 1-1/2 inch
Inline, NPT, STD Brass
Body, Nickel Plated,
Paddlewheel
....... 60610-01HW...Meter Assy, 1-1/2 inch
Inline, NPT, STD Brass, Hot
Water, Paddlewheel
....... 60610-21.........Meter Assy, 1-1/2 inch, BSP,
STD, Brass, Paddlewheel
....... 60610-21NP....Meter Assy, 1-1/2 inch
Inline, BSP, STD, Brass
Body, Nickel Plated,
Paddlewheel
....... 60611-01.........Meter Assy, 1-1/2 inch
Inline, NPT, STD, Brass
Body, Paddlewheel, Sleeve
to 1-inch
....... 60611-01NP....Meter Assy, 1-1/2 inch
Inline, NPT, STD Nickel
Plated, Paddlewheel,
Sleeve to 1-inch
....... 60611-23.........Meter Assy, 1-1/2
inch Inline, BSP, STD,
Paddlewheel, Sleeve to
1-inch
....... 60611-23NP....Meter Assy, 1-1/2 inch
Inline, BSP/MET STD,
Nickel Plated, Paddlewheel,
1-inch Sleeve
12 ..................... 60610-02.........Meter Assy, 1-1/2 inch, NPT,
STD, Brass Paddlewheel
....... 60610-02NP....Meter Assy, 1-1/2 inch
Inline, NPT, EXT Nickel
Plate, Paddlewheel
....... 60610-02HW...Meter Assy, 1-1/2 inch Inline,
NPT, EXT Brass, Hot Water,
Paddlewheel
....... 60610-22.........Meter Assy, 1-1/2 inch, BSP,
EXT, Brass, Paddlewheel
....... 60610-22NP....Meter Assy, 1-1/2 inch Inline,
BSP EXT, Brass Body, Nickel
Plate, Paddlewheel
....... 60611-02.........Meter Assy, 1-1/2 inch
Inline, NPT, EXT Brass Body,
Paddlewheel, Sleeve to
1-inch
....... 60611-02NP....Meter Assy, 1-1/2 inch Inline,
NPT, EXT Nickel Plated,
Paddlewheel, Sleeve to
1-inch
....... 60611-22.........Meter Assy, 1-1/2 inch
Inline, BSP, EXT Brass Body,
Paddlewheel, Sleeve to
1-inch
....... 60611-22NP....Meter Assy, 1-1/2 inch
Inline, BSP, EXT, Nickel,
Paddlewheel, Sleeve to
1-inch
13 ............1...... 19121 ..............Meter Cable Assembly,
....... 19121-08.........Meter Cable Assembly,
35 inch long with connector
....... 19121-09.........Meter Cable Assembly,
100 inch long with connector
....... 19121-10.........Meter Cable Assembly
304 inch long with connector
Not Shown
1 ...... 17790..............Sleeve, Meter, 1 1/2 inch x
1-inch
1 ...... 15218..............Meter Cap Assy, STD Range,
Brass, Hot Water
1 ...... 15237..............Meter Cap Assy, EXT Range,
Brass, Hot Water
Item No. QTY Part No. Description
1
2
3
4
6
1211
78
9
10
5A
5B
FLECK SXT Timer Service Manual • 19

Item No. QTY Part No. Description
1 ..............1...... 62049-01.........Service Kit,
1 inch & 1-1/2 inch Meter,
Standard Range
1 ...... 62049-02.........Service Kit,
1 inch & 1-1/2 inch Meter,
Extended Range
2 ..............1...... 61933-10.........Meter Assy, 1-1/2 inch,
Inline, Stainless Steel, NPT,
Standard Range
1 ...... 61933-11.........Meter Assy, 1-1/2 inch,
Inline, Stainless Steel, NPT,
Extended Range
1 ...... 61933-20.........Meter Assy, 1-1/2 inch,
Inline, Stainless Steel, BSP,
Standard Range
1 ...... 61933-21.........Meter Assy, 1-1/2 inch,
Inline, Stainless Steel, BSP,
Extended Range
3 ..............1...... 44024 ..............Union, 1-1/2 inch, NPT
Optional on models with
electronic controls)
1 ...... 44025..............Union, 1-1/2 inch, BSP
(Optional on models with
electronic controls)
1
3
2
4
1-1/2 INCH STAINLESS STEEL METER ASSEMBLY
4 ..............1...... 19791 ..............Meter Cable Assembly,
....... 19791-02.........Meter Cable Assembly,
28 inch long with connector
....... 19791-04.........Meter Cable Assembly,
100 inch long with connector
....... 19791-05.........Meter Cable Assembly
304 inch long with connector
Not Shown (optional)
1 ...... 62072..............Meter Sleeve,
1-1/2 inch to 1 inch (optional)
Item No. QTY Part No. Description
20 • FLECK SXT Timer Service Manual
Other manuals for FLECK SXT
2
Table of contents