General Installation:
Various configurations and methods of
plumbing this series of solids handling
pumps may be used; however, for
ease of installation and service a
Hydromatic rail lift-out system is
recommended.
Motor:
Each motor is provided with heat
sensor thermostats attached
directly to the motor windings.
The thermostats open if the motor
windingsseeexcessiveheatand,in
turn, open the motor contactor in the
control panel, breaking the power to
the pump.
When the motor is stopped due to an
overheat condition, it will not start
until the motor has cooled and the heat
sensor reset button is manually pushed
on the front of the Hydromatic control
panel. This circuitry is provided in the
Hydromatic control panel designs.
The pumps are equipped with internal
thermostats to meet Class H heat rise
of 356°F (180°C).
Motor Seal Failure Warning:
The seal chamber is oil filled and
provided with moisture sensing probes
to detect water leakage through the
lower shaft seal. The probes can also
detect moisture present in the upper
motor housing.
The presence of water energizes a red
seal leak warning light at the control
panel. This is a warning light only, and
does not stop the motor. It indicates a
leak has occurred and the pump must
be repaired. Normally, this indicates
the outboard seal has leaked. Allowing
the unit to operate after the warning
may cause upper seal leakage along
withmotorfailure.
The resistance across the moisture
sensing (seal failure) probes should
be checked after a seal leak warning
light has lit. This can be done by
disconnecting the red and orange
control wires from the control panel
and measuring the resistance with
an ohmmeter between the wires.
If the measured values are below
specification, the pump may have a
lowersealfailureandrequireservice.
Motor Power Cord, Control Cord and
Cord Cap Assembly:
Each motor power cord has four
conductors: white, black, red and
green. For a three phase motor the
red, black and white conductors
connect to the three line leads, and the
green is connected to a good ground.
Interchanging any two line leads will
reversetherotationofthemotor.
NOTE: Rotation should be clockwise
when observed from the top of
the pump. This can be checked by
noting which direction the pump
torques upon initial starting. A
properly rotating pump will torque
counterclockwise uponstart.
The control cable has five conductors:
black, white, red, orange and green.
White and black connect to the heat
sensor terminals in the control panels;
red and orange connect to the seal
failure terminals in the control panel;
and the green connects to the ground
inthecontrolpanel.
Thecordcapisepoxypotted.The
cord cap provides for a sealed wire
connection with terminals so that
connections can be made without
breaking the motor seal. This allows
the cord cap, with cords, to be
removed from the motor.
NOTE: Each cable has a green ground
wire and must be properly grounded
per the National Electric Code and
local codes.
Electrical Motor Controls:
All electrical controls and motor
starting equipment should be as
specified in these instructions. Consult
factoryforanyacceptablealternatives.
Level Sensing Controls:
Intrinsically safe type float controls
are recommended for all applications.
An intrinsically safe control panel relay
will limit the current and voltage to the
levelcontrols.
The float level controls maintain the
basin sewage water level by controlling
pump turn-on and turn-off levels.
1. The lower turn-off control should
be set so that the pump stops
with the water covering the
entire motor housing. Consult the
factory for any settings below this
point.
2. The upper turn-on control should
be set above the lower turn-off
control.Theexactheightbetween
the two controls is determined
by the number of pump starts
desired and the depth of the
basin.Amaximumof10startsper
hourshouldnotbeexceeded.
3. The override control is set at a
specified height above the upper
turn-on control.
4. The alarm control is set about 6"
to 12" above the override control.
5. No control should be set above
the inlet invert.
Electrical Connections:
All electrical wiring must be in
accordance with local code and only
qualified electricians should make
the installations. All wires should
be checked for shorts to ground
with an ohmmeter or megger after
the connections are made. This is
important, as one grounded wire can
cause failure of the pump, control
panelorcausepersonalinjury.
Caution: The 230 volt 3 phase pump
has a dual marked nameplate. Voltage
may be rewired by the manufacturer
or a Class I Div 1 equipment qualified
electrician. Once the voltage is
changed, the factory cord tag
indicating 230 volt 3 phase must be
removed.
For record keeping purposes, we sug-
gestthepumpbemarkedexternally
withthenewvoltageandqualied
personnel that performed the change.
Pumps shipped from the factory as 460
volt 3 phase cannot be
rewired to any other voltage.