manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Pepperl+Fuchs
  6. •
  7. Power Supply
  8. •
  9. Pepperl+Fuchs FB3205B3 User manual

Pepperl+Fuchs FB3205B3 User manual

Other Pepperl+Fuchs Power Supply manuals

Pepperl+Fuchs KF**-CRG2-Ex1.D Series User manual

Pepperl+Fuchs

Pepperl+Fuchs KF**-CRG2-Ex1.D Series User manual

Pepperl+Fuchs PS1000-A6-48.5 Manual

Pepperl+Fuchs

Pepperl+Fuchs PS1000-A6-48.5 Manual

Pepperl+Fuchs PS1000-A6-24.10 Manual

Pepperl+Fuchs

Pepperl+Fuchs PS1000-A6-24.10 Manual

Pepperl+Fuchs PS1000-A6-24.10.R Manual

Pepperl+Fuchs

Pepperl+Fuchs PS1000-A6-24.10.R Manual

Pepperl+Fuchs SIL KCD2-STC-1.SP User manual

Pepperl+Fuchs

Pepperl+Fuchs SIL KCD2-STC-1.SP User manual

Pepperl+Fuchs HiD2024 User manual

Pepperl+Fuchs

Pepperl+Fuchs HiD2024 User manual

Pepperl+Fuchs PSU1100-J1-AC Series User manual

Pepperl+Fuchs

Pepperl+Fuchs PSU1100-J1-AC Series User manual

Pepperl+Fuchs PS1000-A6-12.16 Manual

Pepperl+Fuchs

Pepperl+Fuchs PS1000-A6-12.16 Manual

Pepperl+Fuchs PS1550 User manual

Pepperl+Fuchs

Pepperl+Fuchs PS1550 User manual

Pepperl+Fuchs HiD2025 User manual

Pepperl+Fuchs

Pepperl+Fuchs HiD2025 User manual

Pepperl+Fuchs HD2 Series User manual

Pepperl+Fuchs

Pepperl+Fuchs HD2 Series User manual

Pepperl+Fuchs HiD2030 User manual

Pepperl+Fuchs

Pepperl+Fuchs HiD2030 User manual

Pepperl+Fuchs PSU1100-J1-DC Series User manual

Pepperl+Fuchs

Pepperl+Fuchs PSU1100-J1-DC Series User manual

Pepperl+Fuchs PS1000-A6-24.20.R Manual

Pepperl+Fuchs

Pepperl+Fuchs PS1000-A6-24.20.R Manual

Pepperl+Fuchs PS1000-A6-24.5 Manual

Pepperl+Fuchs

Pepperl+Fuchs PS1000-A6-24.5 Manual

Pepperl+Fuchs KLD2-PR-Ex1.IEC. User manual

Pepperl+Fuchs

Pepperl+Fuchs KLD2-PR-Ex1.IEC. User manual

Pepperl+Fuchs PS1000-A6-24.20 Manual

Pepperl+Fuchs

Pepperl+Fuchs PS1000-A6-24.20 Manual

Pepperl+Fuchs HiC2027 Series User manual

Pepperl+Fuchs

Pepperl+Fuchs HiC2027 Series User manual

Pepperl+Fuchs HiD2022 Series User manual

Pepperl+Fuchs

Pepperl+Fuchs HiD2022 Series User manual

Pepperl+Fuchs PS3500 N+1 User manual

Pepperl+Fuchs

Pepperl+Fuchs PS3500 N+1 User manual

Pepperl+Fuchs KFD2-STC4-Ex Series User guide

Pepperl+Fuchs

Pepperl+Fuchs KFD2-STC4-Ex Series User guide

Pepperl+Fuchs KF**-CRG2-Ex1.D Series User manual

Pepperl+Fuchs

Pepperl+Fuchs KF**-CRG2-Ex1.D Series User manual

Pepperl+Fuchs KCD2-STC-1 User manual

Pepperl+Fuchs

Pepperl+Fuchs KCD2-STC-1 User manual

Pepperl+Fuchs ENT-DC-30 User manual

Pepperl+Fuchs

Pepperl+Fuchs ENT-DC-30 User manual

Popular Power Supply manuals by other brands

Videx 520MR Installation instruction

Videx

Videx 520MR Installation instruction

Poppstar 1008821 Instructions for use

Poppstar

Poppstar 1008821 Instructions for use

TDK-Lambda LZS-A1000-3 Installation, operation and maintenance manual

TDK-Lambda

TDK-Lambda LZS-A1000-3 Installation, operation and maintenance manual

TDK-Lambda 500A instruction manual

TDK-Lambda

TDK-Lambda 500A instruction manual

Calira EVS 17/07-DS/IU operating instructions

Calira

Calira EVS 17/07-DS/IU operating instructions

Monacor PS-12CCD instruction manual

Monacor

Monacor PS-12CCD instruction manual

VOLTIMA MagicBox 15 Installation and operating instructions

VOLTIMA

VOLTIMA MagicBox 15 Installation and operating instructions

Miller Auto Deltaweld 452 owner's manual

Miller

Miller Auto Deltaweld 452 owner's manual

BCP PUOUBK How to install

BCP

BCP PUOUBK How to install

HC 2210 manual

HC

HC 2210 manual

Agilent Technologies 6032A Service manual

Agilent Technologies

Agilent Technologies 6032A Service manual

Radial Engineering SB-48UB user guide

Radial Engineering

Radial Engineering SB-48UB user guide

Puls CT5.241 installation manual

Puls

Puls CT5.241 installation manual

OCZ ZX1250W Technical specifications

OCZ

OCZ ZX1250W Technical specifications

iseg ECH 238 manual

iseg

iseg ECH 238 manual

Agilent Technologies 6631B Service manual

Agilent Technologies

Agilent Technologies 6631B Service manual

Power XXL A Series instruction manual

Power

Power XXL A Series instruction manual

HP 6200B Operating and service manual

HP

HP 6200B Operating and service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Instruction Manual
1. Marking
(HART)TransmitterPowerSupply,InputIsolatorFB3205B3
ATEXcertificate:Presafe19ATEX14056U
ATEXmarking:
1II2(1)GExdbebq[iaGa]IICGb
II(1)D[ExiaDa]IIIC
I(M1)[ExiaMa]I
IECExcertificate:IECExPRE19.0011U
IECExmarking:
Exdbebq[iaGa]IICGb
[ExiaDa]IIIC
[ExiaMa]I
Pepperl+FuchsGroup
Lilienthalstraße200,68307Mannheim,Germany
Internet:www.pepperl-fuchs.com
2. Validity
Specificprocessesandinstructionsinthisinstructionmanualrequire
specialprovisionstoguaranteethesafetyoftheoperatingpersonnel.
3. Target Group, Personnel
Responsibilityforplanning,assembly,commissioning,operation,
maintenance,anddismountinglieswiththeplantoperator.
Thepersonnelmustbeappropriatelytrainedandqualifiedinordertocarry
outmounting,installation,commissioning,operation,maintenance,and
dismountingofthedevice.Thetrainedandqualifiedpersonnelmusthave
readandunderstoodtheinstructionmanual.
Priortousingtheproductmakeyourselffamiliarwithit.Readthe
instructionmanualcarefully.
4. Reference to Further Documentation
Observedirectives,standards,andnationallawsapplicable
totheintendeduseandtheoperatinglocation.
ObserveDirective1999/92/ECinrelationtohazardousareas.
Observedirectives,standards,andnationallawsapplicabletothe
intendeduseandtheoperatinglocation.
Thecorrespondingdatasheets,manuals,declarationsofconformity,EU-
typeexaminationcertificates,certificates,andcontroldrawings
ifapplicable(seedatasheet)areanintegralpartofthisdocument.Youcan
findthisinformationunderwww.pepperl-fuchs.com.
Forspecificdeviceinformationsuchastheyearofconstruction,
scantheQRcodeonthedevice.Asanalternative,entertheserialnumber
intheserialnumbersearchatwww.pepperl-fuchs.com.
Duetoconstantrevisions,documentationissubjecttopermanentchange.
Pleasereferonlytothemostup-to-dateversion,whichcanbefoundunder
www.pepperl-fuchs.com.
5. Intended Use
Thedeviceisonlyapprovedforappropriateandintendeduse.
Ignoringtheseinstructionswillvoidanywarrantyandabsolve
themanufacturerfromanyliability.
Usethedeviceonlywithinthespecifiedambienttemperaturerange.
Usethedeviceonlywithinthespecifiedambientandoperatingconditions.
Onlyusethedevicestationary.
ThedeviceisanassociatedapparatusaccordingtoIEC/EN60079-11.
TheI/Omodules,comunits,powersupplies,andbusterminationmodules
oftheremoteI/Osystemmustonlybeusedtogetherwiththeassociated
backplanes.
Thebackplaneconnectionsarenon-intrinsicallysafe.
TheI/OmodulesoftheremoteI/Osystemactasaninterfacebetween
signalsfromthehazardousareaandthenon-hazardousarea.
6. Improper Use
Protectionofthepersonnelandtheplantisnotensuredifthedevice
isnotusedaccordingtoitsintendeduse.
Thedeviceisnotsuitableforisolatingsignalsinpowerinstallationsunless
thisisnotedseparatelyinthecorrespondingdatasheet.
7. Mounting and Installation
Priortomounting,installation,andcommissioningofthedeviceyou
shouldmakeyourselffamiliarwiththedeviceandcarefullyreadthe
instructionmanual.
Observetheinstructionmanualsfortheassociatedbackplanes.
Thedevicemustonlybeoperatedinthespecifiedambienttemperature
rangeandatthespecifiedrelativehumiditywithoutcondensation.
Donotmountthedeviceatlocationswhereanaggressiveatmosphere
maybepresent.
Thedevicemustbeinstalledandoperatedonlyinacontrolled
environmentthatensuresapollutiondegree2(orbetter)accordingto
IEC/EN60664-1.
Thedevicemustbeinstalledandoperatedonlyinanenvironmentof
overvoltagecategoryII(orbetter)accordingtoIEC/EN60664-1.
Thepermittedsupplyshort-circuitcurrentforthecomponentsis50A.
Avoidelectrostaticchargeswhichcouldresultinelectrostaticdischarges
whileinstalling,operating,ormaintainingthedevice.
Ifthedevicehasalreadybeenoperatedingeneralelectricalinstallations,
thedevicemaysubsequentlynolongerbeinstalledinelectrical
installationsusedincombinationwithhazardousareas.
Donotmountadamagedorpolluteddevice.
Onlyuseaccessoriesspecifiedbythemanufacturer.
Pushthemoduleintotheslotuntilallrearcatcheshaveaudiblyengaged
inposition.Themodulemustengagetwice.
Donotpushthemodulesintotheslotswithtoomuchforce.Therear
connectionsofthedevicesmaybedamagedifusingexcessiveforce.In
thiscasetheexplosionprotectioncannolongerbeensured.
Thedevicemustbeinstalledandoperatedonlyinsurroundingenclosures
that
lcomplywiththerequirementsforsurroundingenclosuresaccordingto
IEC/EN60079-0,
lareratedwiththedegreeofprotectionIP54accordingto
IEC/EN60529.
ObservetheinstallationinstructionsaccordingtoIEC/EN60079-14.
ThedevicemayonlybeinstalledandoperatedinZone1ifmountedina
surroundingenclosure,whichcorrespondstoequipmentprotection
levelGb.
Ifintrinsicallysafeandnon-intrinsicallysafecircuitsarebeingoperated
together,theconnectionsofthenon-intrinsicallysafecircuitsmustbe
covered.ThecovermustcomplywithdegreeofprotectionIP30according
toIEC/EN60529.
Afieldcircuitmustnothaveapermanentshortcircuit.Eliminatetheshort
circuit.
Requirements for Cables and Connection Lines
Connectadevicewithwireendsorcabletailonlytoterminalswithtypeof
protectionExe.
Observethepermissiblecorecrosssectionoftheconductor.
Observetheinsulationstrippinglength.
Wheninstallingtheconductorstheinsulationmustreach
uptotheterminal.
Whenusingstrandedconductors,crimpwireendferrules
ontheconductorends.
Neverpullthecable.Awirecouldbecomeloosefromtheterminaland
protectionagainstelectricshockcannolongerbeensured.Alwayspull
theterminal.
Unusedcablesandconnectionlinesmustbeeitherconnectedtoterminals
orsecurelytieddownandisolated.
Requirements for Usage as Associated Apparatus
IfcircuitswithtypeofprotectionExiareoperatedwithnon-intrinsically
safecircuits,theymustnolongerbeusedascircuitswithtypeof
protectionExi.
Intrinsicallysafecircuitsofassociatedapparatus(installedinnon-
hazardousarea)canbeledintohazardousareas.Observethe
complianceoftheseparationdistancestoallnon-intrinsicallysafecircuits
accordingtoIEC/EN60079-14.
Observethecomplianceoftheseparationdistancesbetweentwo
adjacentintrinsicallysafecircuitsaccordingtoIEC/EN60079-14.
Observethemaximumvaluesofthedevice,whenconnectingthedevice
tointrinsicallysafeapparatus.
Observetherespectivepeakvaluesofthefielddeviceandtheassociated
apparatuswithregardtoexplosionprotectionwhenconnectingintrinsically
safefielddeviceswithintrinsicallysafecircuitsofassociatedapparatus
(verificationofintrinsicsafety).AlsoobserveIEC/EN60079-14and
IEC/EN60079-25.
Ifmorechannelsofonedeviceareconnectedinparallel,ensurethe
parallelconnectionismadedirectlyattheterminalsofthedevice.When
verifyingtheintrinsicsafety,observethemaximumvaluesfortheparallel
connection.
IfnoLoandCovaluesarespecifiedforthesimultaneousappearanceof
lumpedinductancesandcapacitances,thefollowingruleapplies.
lThespecifiedvalueforLoandCoisusedifoneofthefollowing
conditionsapplies:
lThecircuithasdistributedinductancesandcapacitancesonly,e.g.,
incablesandconnectionlines.
lThetotalvalueofLi(excludingcable)ofthecircuitis<1%ofthe
specifiedLovalue.
lThetotalvalueofCi(excludingcable)ofthecircuitis<1%ofthe
specifiedCovalue.
DOCT-9129/2024-01 1/2
lAmaximumof50%ofthespecifiedvalueforLoandCoisusedifthe
followingconditionapplies:
ThetotalvalueofLi(excludingcable)ofthecircuitis≥1%ofthe
specifiedLovalue.
ThetotalvalueofCi(excludingcable)ofthecircuitis≥1%ofthe
specifiedCovalue.
lThereducedcapacitanceforgasgroupsI,IIA,andIIBmustnotexceed
thevalueof1µF(includingcable).Thereducedcapacitancefor
gasgroupIICmustnotexceedthevalueof600nF(includingcable).
Requirements for Surrounding Enclosures
Placewarningmarking"Warning–Refertoinstructionmanuals!"visiblyon
thesurroundingenclosure.
Placewarningmarking"Warning–Non-intrinsicallysafecircuitsprotected
byinternalcoverwithadegreeofprotectionIP30!"visiblyonthe
surroundingenclosure.
Placewarningmarking"Warning–Avoidelectrostaticcharge!"visiblyon
thesurroundingenclosure.
Avoidelectrostaticchargeswhichcouldresultinelectrostaticdischarges
whileinstalling,operating,ormaintainingthedevice.
Thesurroundingenclosuremaybeopenedformaintenancewhile
energizedinZone1providedthatthefollowingconditionsaremet:
lTheconnectionsofthenon-intrinsicallysafecircuitsmustbeprotected
byacoverwithadegreeofprotectionIP30.
lAllotherdevicesinthesurroundingenclosuremustpermittheopening
ofthesurroundingenclosurewhileenergizedinZone1.
lAnappropriatemarkingisplacedonthesurroundingenclosure.
8. Operation, Maintenance, Repair
Priortousingtheproductmakeyourselffamiliarwithit.Readthe
instructionmanualcarefully.
Donotuseadamagedorpolluteddevice.
Onlyuseaccessoriesspecifiedbythemanufacturer.
Donotrepair,modify,ormanipulatethedevice.
Substitutionofcomponentsmayimpairintrinsicsafety.
Ifthereisadefect,alwaysreplacethedevicewithanoriginaldevice.
Onlyremovethedevicewiththeintegratedremovalsystem.The
integratedremovalsystemrequiresatwo-stepremovalprocess.
1. Unlockandwait(refertotableforwaittime)
2. Remove
Waittime Device
6s I/OmodulesFB*20*,FB*21*
Pushthemoduleintotheslotuntilallrearcatcheshaveaudiblyengaged
inposition.Themodulemustengagetwice.
Donotpushthemodulesintotheslotswithtoomuchforce.Therear
connectionsofthedevicesmaybedamagedifusingexcessiveforce.In
thiscasetheexplosionprotectioncannolongerbeensured.
ObserveIEC/EN60079-17formaintenanceandinspectionofassociated
apparatus.
Thesurroundingenclosuremaybeopenedformaintenancewhile
energizedinZone1providedthatthefollowingconditionsaremet:
lTheconnectionsofthenon-intrinsicallysafecircuitsmustbeprotected
byacoverwithadegreeofprotectionIP30.
lAllotherdevicesinthesurroundingenclosuremustpermittheopening
ofthesurroundingenclosurewhileenergizedinZone1.
lAnappropriatemarkingisplacedonthesurroundingenclosure.
ExceptforFBmoduleswithfrontsideExeconnections,all
FBI/Omodules,FBpowersupplies,FBbusterminationmodules,and
FBcomunitsmaybeswappedinZone1whileenergized(hotswap).
Protecttheboostercablewithatypeofprotectionaccording
toIEC/EN60079-0,whichcorrespondstotherequiredequipment
protectionlevel.
Afieldcircuitmustnothaveapermanentshortcircuit.Eliminatetheshort
circuit.
Requirements for Cables and Connection Lines
Observethepermissiblecorecrosssectionoftheconductor.
Observetheinsulationstrippinglength.
Wheninstallingtheconductorstheinsulationmustreach
uptotheterminal.
Whenusingstrandedconductors,crimpwireendferrules
ontheconductorends.
Neverpullthecable.Awirecouldbecomeloosefromtheterminaland
protectionagainstelectricshockcannolongerbeensured.Alwayspull
theterminal.
Unusedcablesandconnectionlinesmustbeeitherconnectedtoterminals
orsecurelytieddownandisolated.
9. Delivery, Transport, Disposal
Checkthepackagingandcontentsfordamage.
Checkifyouhavereceivedeveryitemandiftheitemsreceivedarethe
onesyouordered.
Keeptheoriginalpackaging.Alwaysstoreandtransportthedeviceinthe
originalpackaging.
Storethedeviceinacleananddryenvironment.Thepermittedambient
conditionsmustbeconsidered,seedatasheet.
Thedevice,built-incomponents,packaging,andanybatteries
containedwithinmustbedisposedincompliancewiththeapplicablelaws
andguidelinesoftherespectivecountry.
DOCT-9129/2024-01 2/2