1. Press and hold the On/Off button for a few seconds.
2. Device will start up.
3. The screen will display 200-second countdown.
1. After power on, 200-second countdown starts.
2. Wait until the countdown finishes.
3. The result will display on screen and indicator lights glow.
4. Press the On/Off button to turn on/off the backlight.
1. Press and hold the On/Off button for a few seconds.
Indicator lights definition:
1. Green light: good air quality.
2. Yellow light: gas concentration is out of limits, ventilation is needed.
3. Red light: gas concentration is severely out of limits, a comprehensive
indoor air clean up is recommended.
4. Red light twinkling: gas concentration is out of detection range,
please vacate the premises immediately.
Reference
Flammable Gas Concentration < 2500 ppm
--> Green light turns on.
2500 ppm ≤Flammable Gas Concentration < 4000 ppm
-->Yellow light turns on.
Flammable Gas Concentration ≥4000 ppm