Philio PSE04-A User manual

Multiple Sound Siren PSE04 A/B
Built-in high accuracy Temperature sensor
The PSE04 is a wireless siren, based on Z-Wave
TM
technology. It is the
Z-Wave Pl s
TM
prod ct, it s pport the sec rity, OTA... Those newest
feat res of the Z-Wave
TM
technology. Z-Wave
TM
is a wireless
comm nication protocol designed for home a tomation, specifically to
remotely control applications in residential and light commercial
environments. The technology ses a low-power RF radio embedded or
retrofitted into home electronics devices and systems, s ch as lighting,
home access control, entertainment systems and ho sehold appliances.
This prod ct can be incl ded and operated in any Z-Wave
TM
network
with other Z-Wave
TM
certified devices from other man fact rers and/or
other applications. All non-battery operated nodes within the network
will act as repeaters regardless of vendor to increase reliability of the
network.
The device adopt the Z-Wave
TM
700 series chip, when yo r Z-Wave
TM
network system is all made by Z-Wave
TM
700 series devices. The
network system will have the advantages as below.
•Conc rrent m lti-channel s pport red ces external interference.
•Better RF range, improve abo t 10 meters in indoor.
•S pport 100 Kbps transmit speed, speed p comm nication.
Specification
Rating 6VDC (AA Battery *4), Max.300mA
RF distance Min. 40M indoor,
100M o tdoor line of sight,
RF Freq ency
868.40 MHz, 869.85 MHz(EU)
908.40 MHz, 916.00 MHz(US)
920.9MHz, 921.7MHz, 923.1MHz
(TW/KR/Thai/SG)
RF Maxim m Power +10dBm (Peak), -10dBm (Average)
Dimension 170mm(L) X 58mm (W) X 30mm(H)
Weight 205g
IP classification, Location IPx4; O tdoor se
Operation temperat re -20 to 54° C
H midity 85%RH max
FCC ID RHHPSE04
Max. so nd d ration time 110dB @30cm
M lti so nd
6 Different tunes, Fire
Alarm/Ambulance/Police/Alarm/Door
chime/beep
Temperat re detector range -20 to 54° C
Specifications are s bject to change and improvement witho t notice.
1

F
FF
Fu
uu
un
nn
nc
cc
c
o
oo
on
nn
n
Siren Temperature
sensor
PSE04-A V V
PSE04- V
Troubleshooting
Symptom Ca se of Fail re Recommendation
The device can not
join to Z-Wave™
network
The device may in a Z-
Wave™ network.
Excl de the device
then incl de again.
For Instruction to http:// www.philio-tech.com
Overview
CAUTION
– replacement of a battery with an incorrect type that can defeat a
safeguard (for example, in the case of some lithium battery types);
– disposal of a battery into fire or a hot oven, or mechanically crushing
or cutting of a battery, that can result in an explosion;
– leaving a battery in an extremely high temperature surrounding
environment that can result in an explosion or the leakage of flammable
liquid or gas;
– a battery subjected to extremely low air pressure that may result in an
explosion or the leakage of flammable liquid or gas
The marking information is located at the bottom of the apparatus.
2

Battery Installation
When the device report the low battery message. The ser sho ld
replace the battery to new one. The battery type is AA, 1.5V
Please loosen the screw on the back cover to release the front cover
3

Addin to Z-Wave
TM
Network
There is one tamper key on the device. The tamper key can add,
remove, reset from Z-Wave
TM
network.
In the first time, add the device into the Z-Wave
TM
network. First,
make s re the primary controller is in the add mode. And then power
on the device. The device will a to start the SmartStart Incl sion mode.
Notice: Incl ding a node ID allocated by Z-Wave
TM
Controller means
“Add” or “Inclusion”. Excl ding a node ID allocated by Z-Wave
TM
Controller means “Remove” or “Exclusion”.
Function Description
Add
1. Have Z-Wave
TM
Controller entered incl sion mode.
2. Pressing tamper key three times within 1.5 seconds
to enter the incl sion mode.
3. After add s ccessf l, the LED will light ON 1 second
Remove
1. Have Z-Wave
TM
Controller entered excl sion mode.
2. Pressing tamper key three times within 1.5 seconds
to enter the excl sion mode.
3. Node ID has been excl ded.
Reset
Notice: Use this procedure only in the event
that the primary controller is lost or
otherwise inoperable.
1. Pressing tamper key fo r times within 1.5 seconds
and do not release the tamper key in the 4
th
pressed, and the LED will light ON.
2. After 3 seconds the LED will t rn OFF, after that
within 2 seconds, release the tamper key. If
s ccessf l, the LED will light ON one second.
Otherwise, the LED will flash once.
3. IDs are excl ded and all settings will reset to
factory defa lt.
SmartStart
1. Prod ct has a DSK string , yo can key in first five
digit to increment SmartStart process,or yo can
scan QR code.
Ex:mydsk
10209-46687-52248-13629-04783-07465-15776-56519
2. SmartStart enabled prod cts can be added into a
Z-Wave network by scanning the Z-Wave QR Code
present on the prod ct providing SmartStart
incl sion. No f rther action is req ired and the
SmartStart prod ct will be added a tomatically
within 10 min tes of min tes On in the network
vicinity.
*notice1:The QR code can be fo nd on the device
PSE04 or on the box.
Association
This machine provides one gro ps of nodes. Each
gro p can set 1 Nodes.
Gro p 1 is called Lifeline the device will report :
1.Notification report
2.Sensor m ltilevel report
3.Device Reset Locally Notification
4.Battery Report
5.Indicator Report
•Failed or s ccess in incl ding/excl ding the node ID can be
viewed from Z-Wave
TM
Controller.
Notice 1: Always RESET a Z-Wave
TM
device before trying to add it to a
Z-Wave
TM
network.
4

LED Li ht Indication
The LED light indicates the different modes of the PSE04
State Type LED Indication
Witho t Node ID Under normal operation, when the PSE04 has not
been allocated a node ID, the LED light will flash on
and off alternately at 0.5 second intervals. By
pressing the On/Off b tton, LED light will stop
flashing temporarily.
Learning Slow flashes once when learning is s ccessf l.
Alarm Trigger All LED flashes ntil trigger off.
Z-Wave
TM
Messa e Report
In defa lt the device will sing Notification Report to represent the
tamper trigger event.
* Tamper Report:
When the tamper key is pressed over 5 seconds. The device will into
the alarm state. In that state, if the tamper key be released, the device
will nsolicited to send the report to the nodes in the gro p 1.
Notification Report (V8)
Notification Type: Home Sec rity (0x07)
Event: Tampering. Prod ct covering removed (0x03)
* Siren State Report:
When the siren start playing or stop the alarm so nds, the device will
nsolicited to send the “Notification Report” to the nodes in the gro p
1.
Notification Report (V8)
Notification Type: Siren (0x0E)
Event: Siren active (0x01) , Siren idle (0x00)
*Temperature Report:
When the temperat re differential over, the device will nsolicited to
send the “Sensor M ltilevel Report” to the nodes in the lifeline gro p.
Sensor Type: Temperat re (0x01)
*** Temperat re differential report ***
This f nction defa lt is disable, to enable this f nction by setting the
config ration NO.5 is greater than 0.
In the defa lt, is disable temperat re differential report.
If setting the config ration NO.5 to 1, when the temperat re is
changed to pl s or min s one degree Celsi s (1.8 degree Fahrenheit),
the device will report temperat re information to the nodes in the
lifeline gro p.
The device will meas re the temperat re in every 10 seconds.
Notice 1:
The PSE04 m st stay awake for at least 2 seconds after
comm nicating, so therefore the more comm nication, the power
consumption fast, please pay attention to se config ration NO.5.
Notice 2:
This prod ct cannot reflect o tdoor temperat re immediately
beca se of the temperat re sensor eq ipped inside rather than s rface.
5

*Play Sound:
Using the BASIC_SET or So nd_Switch_Tone_Play_Set to play the
siren, BASIC_SET
or
So nd_Switch_Tone_Play_Set
with Val e 0xFF, the
So nd ID will be the same as the val e which was set in Config ration
No.7
, 0x00 will stop to play.
Basic Set (V2) or Sound Switch Tone Pley Set (V1)
Val e So nd
0x00 Stop Play
0x01 Fire
0x02 Amb lance
0x03 Police
0x04 Alarm
0x05 Ding Dong
0x06 Beep
0xFF Same as config ration NO.7 setting,
or so nd switch config ration setting.
* Timin Report:
Beside the event triggered co ld report message, the device also
s pport the timing nsolicited report of the stat s.
●Battery level report: Every 6 ho rs report once in defa lt.
It co ld be changed by setting the config ration NO. 6.
●Low battery report: When the battery level is too low, every 30
min tes will report once.
●Temperat re report: Every 6 ho rs report once in defa lt.
It co ld be changed by setting the config ration NO. 4.
Notice: The config ration NO. 4 and 6 co ld be setting to
zero to disable the a to report. And the config ration NO. 1 co ld
change the tick interval, the defa lt val e is 30, if setting to 1, that
means the minim m a to report interval will be one min te. And please
notice if setting this val e to zero, that means disable all of the timing
report except the low battery detection.
Power Up Procedure
*Battery Power Check
When the device power p, the device will detect the power level of the
battery immediately. If the power level is too low, device will report low
battery even every 30 min tes. Please change another new battery.
*Wake up beam
If a Z-Wave controller or other node in the network needs to
comm nicate with a battery-powered device s ch as a door lock, the
controller sends a special beam signal. The p rpose of this beam is to
wake p the FLiRS device.
When the FLiRS device receives this beam, it immediately f lly wakes
p and then comm nicates with the controller or other Z-Wave device
tilizing standard Z-Wave protocol commands. If the device does not
hear a Beam it goes back to f ll sleep for another period ntil it
partially awakes again and listens for a Beam.
Over The Air (OTA) Firmware Update
The device is supported with Z-Wave™ firmware update via OTA.
1. Set the Z-Wave
TM
Controller into the firmware update mode.
2. Choose the hex file to update the firmware.
3. Wait 10~15 minutes for completing the OTA process.
4. Result of OTA will show in Z-Wave™ Controller log.
6

During the OTA process, please DO NOT remove the power,
otherwise, the firmware will be broken, and the device will be
nonfunctional.
Z-Wave Confi uration Settin s
Notice 1:
All of the config ration, the data size is 1.
Notice 2:
The reserve bit or not s pported bit is allowed any val e, b t no
effect.
Notice 3:
The PSE04 m st stay awake for at least 2 seconds after
comm nicating, so therefore the more comm nication, the
power
consumption
fast, please pay attention to se
config ration
NO.1, NO.4,
NO.5, NO.6.
NO. Name Def. Valid Description
1A to Report
Tick Interval 0x1E 0~255 The interval time for a to report
each tick.
2So nd
D ration 0x06 0~255 Play so nd d ration, 1 tick is 30
seconds.
3 C stomer
F nction 0x00 All C stomer f nction switch, sing
bit control.
0
Bit0: Disable Trigger Alarm.
0:Enable , 1:Disable.
0
Bit1: Disable So nd. Only sing
optical alarm. 0:Enable ,
1:Disable.
0
Bit2: Temperat re Unit.
0:Fahrenheit , 1:Celsi s.
0
Bit3: Reserve.
0
Bit4: Reserve.
0
Bit5: Reserve.
0
Bit6: Reserve.
0
Bit7: Reserve.
4
A to Report
Temperat re
Time 0x0C 0~255 The interval time for a to report
the temperat re.
5
Temperat re
Differential
Report
0x00 0~255 The temperat re differential to
report.
6A to Report
Battery Time 0x0C 0~255 The interval time for a to report
the battery level.
7Play So nd
Control
0x43 All Control play so nd's level and
which so nd.
3
Bit0~1: Play so nd's level.
Level 1~3, 0: Level 3.
0
Bit2: Reserve.
0
Bit3: Reserve.
4
Bit4~7: Which so nd id will
play, when control form
controller.
So nd ID 1~6, 0: Disable.
7

Z-Wave Supported Command Class
Command Class Version Required Security Class
Z-Wave Pl s™ Info 2None
Sec rity 1None
Sec rity 2 1None
S pervision 1None
Transport Service 2None
Association 2Highest granted Sec rity Class
Association Gro p
Information
3Highest granted Sec rity Class
Device Reset Locally 1Highest granted Sec rity Class
Firmware Update Meta
Data
5Highest granted Sec rity Class
Indicator 3Highest granted Sec rity Class
Man fact rer Specific 2Highest granted Sec rity Class
M lti-Channel Association 3Highest granted Sec rity Class
Powerlevel 1Highest granted Sec rity Class
Version 3Highest granted Sec rity Class
Config ration 4Highest granted Sec rity Class
Sensor M ltilevel 11 Highest granted Sec rity Class
Basic 1 Highest granted Sec rity Class
Notification 8 Highest granted Sec rity Class
So nd Switch 1 Highest granted Sec rity Class
Battery 1 Highest granted Sec rity Class
Warnin
Caution,
avoid listenin at hi h volume levels for lon
periods
CAUTION
Risk of explosion if battery is replaced by an incorrect type.
Dispose of used battery accordin to the instructions.
Choosin a Suitable Location
1. The s itable ambient temperat re for the mod le/device is
0°C~40°C.
2. Do NOT place the mod le/device direct nder s nlight, in a h mid
place or in any location where they may contact moist re, dirt, d st.
3. Do NOT place the mod le/device where exists comb stible
s bstances or any so rce of heat, fires, radiators, boiler etc.
Disposal
This marking indicates that this prod ct sho ld not
be disposed with other ho sehold wastes thro gho t
the EU. To prevent possible harm to the
environment or h man health from ncontrolled
waste disposal, recycle it responsibly to promote the
s stainable re se of material reso rces. To ret rn
yo r sed device, please se the ret rn and
collection systems or contact the retailer where the
prod ct was p rchased. They can take this prod ct
for environmentally safe recycling.
Philio Technology Corporation
8F., No.653-2, Zhongzheng Rd., Xinzh ang Dist., New Taipei City
24257, Taiwan(R.O.C)
w ww.philio-tech.com
8

FCC Interference Statement
This eq ipment has been tested and fo nd to comply with the limits
for a Class B digital device, p rs ant to Part 15 of the FCC R les.
These limits are designed to provide reasonable protection against
harmf l interference in a residential installation.
This eq ipment generates, ses, and can radiate radio freq ency en-
ergy and, if not installed and sed in accordance with the instr ctions,
may ca se harmf l interference to radio comm nications.
However, there is no g arantee that interference will not occ r in a
partic lar installation.
If this eq ipment does ca se harmf l interference to radio or televi-
sion reception, which can be determined by t rning the eq ipment off
and on, the ser is enco raged to try to correct the interference by one
of the following meas res:
•Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is sub-
ject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including inter-
ference that may cause undesired operation.
FCC Caution: Any changes or modifications not expressly approved by
the party responsible for compliance could void the user's authority to
operate this equipment.
This transmitter must not be co-located or operating in conjunction with
any other antenna or transmitter.
警
警警
警語
語語
語:
::
:
「取得審驗證明之低功率射頻器材,非經核准,公司、商號或使用者均不得擅自變
更頻率、加大功率或變更原設計之特性及功能。
低功率射頻器材之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,
應立即停用,並改善至無干擾時方得繼續使用。
前述合法通信,指依電信管理法規定作業之無線電通信。低功率射頻器材須忍受合
法通信或工業、科學及醫療用電波輻射性電機設備之干擾。」
9
This manual suits for next models
1
Table of contents
Other Philio Security System manuals
Popular Security System manuals by other brands

WiLife
WiLife V2.5 user guide

Alderon Industries
Alderon Industries Oil Alert VA02 Operation, maintenance and installation manual

GE Security
GE Security Simon XT user manual

Honeywell
Honeywell Le Sucre user guide

GE Interlogix
GE Interlogix 60-792-01-95R User instructions

TARGET TECHNOLOGY
TARGET TECHNOLOGY DUAL-4000-ANZ instruction manual