Philips 223289 User manual

315/16"
2 7/32"
MasterColor®Ceramic Metal Halide
39 Watt T-6 3K Lamp
with FadeBlock™
■Ordering Information
Ordering Code CDM35/T6/830
ANSI Designation M130/E
Product Number 223289
Description MasterColor
Ceramic Metal Halide
Package Qty. 12
■Physical Characteristics
Bulb Size T-6
Bulb Finish Clear
Base G-12 Bi-Pin
Max. Overall Length (MOL) 3 15/16" (100 mm)
Light Center Length (LCL) 2 7/32" (56 mm)
Arc Length 0.2" (5 mm)
Arc Tube Material Polycrystalline Alumina
Max. Permissible Bulb Temp. 500º C (932º F)
Max. Permissible Base Temp. 280º C (536º F)
Max. Bulb to Base Eccentricity 3º
Max.Arc Tube to Base Eccentricity 3º
■Operating Characteristics (Photometric)
Rated Initial Lumens(1) 3300
Mean Lumens,Approx.(2) 2600
Rated Average Life, Hours 12,000
Correlated Color Temp. (CCT)(2) 3000K
CIE Chromaticity,Approx.(2) x-.428, y-.397
Color Rendering Index (CRI) 81
Efficacy (lpw) 87
■Operating Position
Universal-Enclosed Luminaires Only
Note: Electronic ballasts are preferred for optimum performance, energy
efficiency and circuit loading.
MasterColor® Spectral Power Distribution—3KTypes
RELATIVE ENERGY
400 450 500 550 600 650 700
WAVELENGTH (Nanometers)
350
300
250
200
150
100
50
0
(1) Measured at 100 hours of life in vertical position.
(2) Measured at rated lamp watts on a linear reactor. LPW does not include ballast losses.
(3) Measured with the lamp operating at rated watts.
Electrical Data (Subject to change without notice)
Lamp Watts (Nominal) . . . . . . . . . . . . . . . . . . . . . . . . . 39
Lamp Operating Voltage (rms) (Nominal)(2) . . . . . . . . . . 88
Initial Lamp Voltage Range (rms)(3). . . . . . . . . . . . . . . . . 85–105
Lamp Operating Current (Amps) (rms) (Nominal). . . . 0.53
Lamp Current Crest Factor (Maximum). . . . . . . . . . . . 1.8
Warm-up Time to 80% of Output . . . . . . . . . . . . . . . . 2 Minutes
Re-strike Time for Hot Lamp . . . . . . . . . . . . . . . . . . . . 4–8 Minutes
Ballast Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ANSI M130
Ballast Open Circuit Voltage (Minimum) . . . . . . . . . . . . 198
Pulse Peak Volts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3000 Min., 4000 Max.
Pulse Width @ 90% Peak. . . . . . . . . . . . . . . . . . . . . . . 2 Micro Second Min.
Pulse Repetition Rate (Minimum). . . . . . . . . . . . . . . . . 2 per Half Cycle
Minimum Operating Temperature. . . . . . . . . . . . . . . . . -30ºC
MasterColor®Ceramic Metal Halide 39 Watt T-6 3K Lamp with FadeBlock™
Philips Lighting Company
200 Franklin Square Drive ■P. O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
www.lighting.philips.com/nam
A Division of Philips Electronics North America Corporation
Printed in USA 5/04 CDM 001
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
www.lighting.philips.com/nam
A Division of Philips Electronics Ltd.
R
“WARNING: These lamps can cause serious skin burn and eye inflammation from
short wave ultraviolet radiation if outer envelope of the lamp is broken or punctured.
Do not use where people will remain for more than a few minutes unless adequate shielding or
other safety precautions are used. Certain lamps that will automatically extinguish when the
outer envelope is broken or punctured are commercially available.”This lamp complies
with FDA radiation performance standard 21 CFR subchapter J. (USA:21CFR 1040.30
Canada:SOR/DORS/80-381)
If the outer bulb is broken or punctured, turn off at once and replace the lamp to
avoid possible injury from hazardous short wave ultraviolet radiation. Do not
scratch the outer bulb or subject it to pressure as this could cause the outer
bulb to crack or shatter.A partial vacuum in the outer bulb may cause glass to
fly if the envelope is struck.
WARNING: The arc-tube of metal halide lamps are designed to operate under high pressure
and at temperatures up to 1000º C and can unexpectedly rupture due to internal or external
factors such as a ballast failure or misapplication If the arc-tube ruptures for any reason, the
outer bulb may break and pieces of extremely hot glass might be discharged into the sur-
rounding environment. If such a rupture were to happen, THERE IS A RISK OF PER-
SONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
Certain lamps that will retain all the glass particles should inner arc-tube
rupture occur are commercially available from Philips Lighting Company.
RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE.Allowing
lamps to operate until they fail is not advised and may increase the
possibility of inner arc tube rupture.
This lamp contains an arc tube with a filling gas containing Kr-85 and is distrib-
uted by Philips Lighting Company, a division of Philips Electronics North America
Corporation, Somerset, New Jersey, 08875.
CAUTION: TO REDUCE THE RISK OF PERSONAL INJURY, PROPERTY DAMAGE,
BURNS AND FIRE RESULTING FROM AN ARC-TUBE RUPTURE THE FOLLOWING
LAMP OPERA
TING INSTRUCTIONS MUST BE FOLLOWED:
LAMP OPERA
TING INSTRUCTIONS:
1. RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE. Allowing lamps to
operate until they fail is not advised and may increase the possibility of inner arc tube
rupture.
2. Use only in fully enclosed fixtures capable of withstanding particles of glass having tem-
peratures up to 1000ºC. Lens/diffuser material must be heat resistant. Consult fixture
manufacturer regarding the suitability of the fixture for this lamp.
3. Do not operate a fixture with a missing or broken lens/diffuser.
4. Operate lamp only within specified limits of operating position.
5. Before lamp installation/replacement, shut power off and allow lamp and fixture to cool
to avoid electrical shock and potential burn hazards.
6. Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage
limits recommended by ballast manufacturer.
A. Operate lamp only within specified limits of operation.
B. For total supply load refer to ballast manufacturers electrical data.
C. Operate CDM-T (G12 base) and CDM-TC (G8.5 base) lamps only
on thermally protected ballasts.
D. Operate CDM-TC lamps (G8.5 base) only on electronic ballasts.
7. Periodically inspect the outer envelope. Replace any lamps that show scratches, cracks
or damage.
8.
If a lamp bulb support is used, be sure to insulate the support electrically to avoid possible
decomposition of the bulb glass.
9. Protect lamp base, socket and wiring against moisture, corrosive atmospheres and
excessive heat.
10.Time should be allowed for lamps to stabilize in color when turned on for the first
time.This may require several hours of operation, with more than one start. Lamp
color is also subject to change under conditions of excess vibration or shock and color
appearance may vary between individual lamps.
11. Lamps may require 4 to 8 minutes to re-light if there is a power interruption.
12.Take care in handling and disposing of lamps. If an arc tube is broken, avoid skin contact
with any of the contents or fragments.
WARNINGS, CAUTIONS AND OPERATING INSTRUCTIONS
INSTALLATION INFORMATION
MasterColor®Metal Halide T-6 lamps must be used in combination with appropriate ballast and ignitor or suitable full electronic ballast. For satisfactory
operation of the lamp, the supply voltage should not fluctuate more than ±5% from the rated voltae of the ballast (±10% for electronic ballast).

Other Philips Indoor Furnishing manuals

Philips Ledino 57923/31/16 User manual

Philips

Philips Ledino 57923/31/16 User manual

Philips 288720 User manual

Philips

Philips 288720 User manual

Philips Basic HID Lamp User manual

Philips

Philips Basic HID Lamp User manual

Philips H33 User manual

Philips

Philips H33 User manual

Philips 15698-3 User manual

Philips

Philips 15698-3 User manual

Philips SND-5084 User manual

Philips

Philips SND-5084 User manual

Philips LivingColors LCS3002 User manual

Philips

Philips LivingColors LCS3002 User manual

Philips P-2494-C User manual

Philips

Philips P-2494-C User manual

Philips PL-T57W User manual

Philips

Philips PL-T57W User manual

Philips Ledino 66702/87/16 User manual

Philips

Philips Ledino 66702/87/16 User manual

Philips Lamps IRC MR16 User manual

Philips

Philips Lamps IRC MR16 User manual

Philips Ledino 44992/30/16 User manual

Philips

Philips Ledino 44992/30/16 User manual

Philips P-2543-C User manual

Philips

Philips P-2543-C User manual

Philips 207571 User manual

Philips

Philips 207571 User manual

Philips Baby NightLight Owner's manual

Philips

Philips Baby NightLight Owner's manual

Philips 14837-9 User manual

Philips

Philips 14837-9 User manual

Philips Coloured CandleLights User manual

Philips

Philips Coloured CandleLights User manual

Philips AquaLights Owner's manual

Philips

Philips AquaLights Owner's manual

Philips Energy Advantage P-6018 User manual

Philips

Philips Energy Advantage P-6018 User manual

Philips Electromagnetic Lamp User manual

Philips

Philips Electromagnetic Lamp User manual

Philips P-2055-D User manual

Philips

Philips P-2055-D User manual

Philips Ledino 33602/87/16 User manual

Philips

Philips Ledino 33602/87/16 User manual

Philips 800 series Installation and operation manual

Philips

Philips 800 series Installation and operation manual

Philips HF3461 User manual

Philips

Philips HF3461 User manual

Popular Indoor Furnishing manuals by other brands

Furniture of America CM7682EK Assembly instructions

Furniture of America

Furniture of America CM7682EK Assembly instructions

Lancaster Bistro Barstool Assembly instructions

Lancaster

Lancaster Bistro Barstool Assembly instructions

Northbeam WINDSOR BCH0301720800 manual

Northbeam

Northbeam WINDSOR BCH0301720800 manual

Strictly Beds & Bunks Triad Triple Bunk Bed Assembly instructions

Strictly Beds & Bunks

Strictly Beds & Bunks Triad Triple Bunk Bed Assembly instructions

Cooper Lighting Shaper 260 Specification sheet

Cooper Lighting

Cooper Lighting Shaper 260 Specification sheet

Next BRONX 685006 Assembly instructions

Next

Next BRONX 685006 Assembly instructions

Unfinished Furniture of Wilmington S-6173 Assembly instructions

Unfinished Furniture of Wilmington

Unfinished Furniture of Wilmington S-6173 Assembly instructions

Origin 21 APOLLO 36AL installation manual

Origin 21

Origin 21 APOLLO 36AL installation manual

Accentrics Home D472-700-2 Assembly instructions

Accentrics Home

Accentrics Home D472-700-2 Assembly instructions

Mocka Jordi Desk Assembly instructions

Mocka

Mocka Jordi Desk Assembly instructions

Euronda CORAL manual

Euronda

Euronda CORAL manual

Lightolier Lighting Systems LP-14 Specification sheet

Lightolier

Lightolier Lighting Systems LP-14 Specification sheet

Songmics VASAGLE LBT10 manual

Songmics

Songmics VASAGLE LBT10 manual

Better Bathrooms Westbury BeBa 27032 user manual

Better Bathrooms

Better Bathrooms Westbury BeBa 27032 user manual

Safco Medina 6827 instructions

Safco

Safco Medina 6827 instructions

Mayline Tiffany Industries Talon Tables Assembly instructions

Mayline

Mayline Tiffany Industries Talon Tables Assembly instructions

Forte MQRL2182 Assembling Instruction

Forte

Forte MQRL2182 Assembling Instruction

Birlea MAYFAIR 5' BED Assembly instructions

Birlea

Birlea MAYFAIR 5' BED Assembly instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.