Page 1.1
30A & 10A FAULT INSERTION SWITCHES 40-191/192
pickering SECTION 1 - TECHNICAL SPECIFICATION
SECTION 1 - TECHNICAL SPECIFICATION
pickeringtest.com
PXI 30 A Fault Insertion Switch Module 40-191
ISSUE 5.2 NOV 2021
Supported by
eBIRST
eBIRST switching system test tools simplify switching
system fault-finding by quickly testing the system and
graphically identifying the faulty relay.
For more information go to: pickeringtest.com/ebirst
y6 Fault Insertion Channels
y40 A Single Channel
y30 A Continuous, All Channels
ySimulation of Various Types of Electrical Fault,
Enabling Rigorous Fault Testing
y2 Fault Insertion Buses
yHigh Inrush Current Rating
ySwitch ±40 V Signals (AC or DC)
yVISA, IVI & Kernel Drivers Supplied for Windows
ySupported by PXI or LXI Chassis
ySupported by
eBIRST
™
y3 Year Warranty
U2
U3
U4
M2
M3
M4
U5
U6
M5
M6
Stimulus/Measurement Connections
UUT Connections
Fault Insertion Bus 2
Fault Insertion Bus 1
Fault Connections
COM1
COM2
U1
M1
40-191 6-Channel Fault Insertion Switch
Schematic Diagram
The 40-191 is a 6 Channel Fault Insertion switch designed
for the simulation of fault conditions in automotive systems.
It is capable of carrying 40 A on single channel or 30 A on all
channels simultaneously and provides a robust solution to
high current fault insertion.
It is designed to insert 3 different fault conditions between the
test fixture and the equipment under test:
• Open-Circuit
• Short-Circuit between UUT connections
• Short-Circuit to external signals
Channel through relays enable signals to the UUT to be set
open-circuit. Two fault insertion buses can be used to short
channels together or connect a channel to an external signal
such as power, ignition or ground to simulate fault conditions.
The 40-191 uses solid state switching capable of withstanding
inrush current greater than 120 A and peak voltage of 40 V.
With an indefinite number of switching operations the 40-191
can hot switch AC or DC with no life degradation.
Pickering’s Range of PXI Fault Insertion Switches
Model
No. Signal Channels Fault
Buses
Fault
Inputs
Max
Voltage
Max Current
or Bus Type
40-190B 74, 64 or 32 1 or 2 4 or 8 165 V 2 A
40-191 6 2 2 40 V 30 A
40-192 6 2 2 200 V 10 A
40-193 7 1 or 2 1 or 2 16 V 20 A, 1 A min
40-194 7 1 or 2 1 or 2 16 V 20 A, no min
40-195 22 or 11 pairs — 8 or 4 150 V 1 A
40-196 10 or 5 pairs — 10 or 5 110 V 5 A
40-197A 34 or 16 4 8 300 V 2 A
40-198 20 1 or 2 3 or 6 250 V 5 A
40-199 10 1 or 2 2 250 V 10 A
40-200 4 or 8 differential 4 8 100 V CAN, FlexRay
40-201 4 or 8 differential 2 4 100 V
Ethernet/
AFDX/
BroadR-Reach
40-202 22 or 11 pairs — 22 or 11 150 V 1 A