pickeringtest.com
PXI 10A Fault Insertion Switch 40-199
ISSUE 4.2 DEC 2019
• 10 Fault Insertion Channels
• Suitable for Automotive/Avionics ECU Burn-in/
Endurance Test Applications
• High Quality Electro-Mechanical Relays
• Simulation of Various Types of Electrical Fault, Enabling
Rigorous Fault Testing
• Choice of 1 or 2 Fault Insertion Buses
• 10A Hot or Cold Switching & up to 300W/2500VA Power
• Hot Switch up to 125VDC or 250VAC
• VISA, IVI & Kernel Drivers Supplied for Windows
• Supported by PXI or LXI Chassis
• 3 Year Warranty
U3
U4
U5
M3
M4
M5
U6
U7
M6
M7
Stimulus/Measurement Connections
UUT Connections
Fault Insertion Bus 2
Fault Insertion Bus 1
Fault Connections
F1
F2
U8
M8
U1
M1
U9
M9
U2
M2
20A
Fault Bus
Rating
U10
M10
40-199-002 Fault Insertion Switch Schematic
Diagram. This version has 2 fault buses, the
40-199-001 has 1 fault bus
The 40-199 is a 10 Channel Fault Insertion switch designed for the
simulation of fault conditions in automotive/avionics applications,
involving the reliability testing of safety critical controllers.
It is designed to be able to insert different fault conditions between
the test xture and the equipment under test:
• Open-Circuit
• Short-Circuit between UUT connections
• Short-Circuit to other signals such as Power, Ignition & Ground
via Fault Insertion Bus
Through relays on each channel enable signals to be held open-
circuit. Fault insertion buses allow channels to be shorted together
or to be connected to an external fault condition such as power,
ignition or ground. The module is available with either 1 fault bus
(40-199-001) or 2 fault buses (40-199-002).
The 40-199 uses high quality electro-mechanical power relays with
10A hot or cold switching capability. All relays are normally open
types. The fault buses are rated at 20A in order to allow two 10A
fault connections to each bus.
Pickering’s Range of PXI Fault Insertion Switches
Model
No. Signal Channels Fault
Buses
Fault
Inputs
Max
Voltage
Max Current
or Bus Type
40-190B 74, 64 or 32 1 or 2 4 or 8 165V 2A
40-191A 6 2 2 40V 30A
40-192 6 2 2 200V 10A
40-193 7 1 or 2 1 or 2 16V 20A, 1A min
40-194 7 1 or 2 1 or 2 16V 20A, no min
40-195 22 or 11 pairs — 8 or 4 150V 1A
40-196 10 or 5 pairs — 10 or 5 110V 5A
40-197A 34 or 16 4 8 300V 2A
40-198 20 1 or 2 3 or 6 250V 5A
40-199 10 1 or 2 2 250V 10A
40-200 4 or 8 differential 4 8 100V CAN, FlexRay
40-201 4 or 8 differential 2 4 100V Ethernet/AFDX
/BroadR-Reach
40-202 22 or 11 pairs — 22 or 11 150V 1A