Ye s
NoReplace the switch.
OK
The pitch does not change even if
the TEMPO slider knob is moved.
Does the tact switch
(SW301) on the MAIN
PCB Assy work?
Does the tact switch
(SW301) on the MAIN
PCB Assy work?
Does the tact switch
(SW301) on the MAIN
PCB Assy work?
Does the tact switch
(SW301) on the MAIN
PCB Assy work?
NoReplace the switch.
NoReplace the switch.
NoReplace the switch.
Ye s
Ye s
Ye s
Ye s
The TEMPO cannot be reset.
NoReplace the switch.
The tempo range cannot be
changed.
Ye s
No
Only the LEDs may be in failure.
Replace the LEDs (D313–315) on
the MAINPCB Assy.
If you move the TEMPO slider knob to
the end of the + side then press the
TEMPO RANGE button, do the
strobe patterns change?
No
The VR data may not be input to the
CPU (thus, the same rotation speed is
maintained). Check if VR301 on the
MAINPCB Assy has any problem,
referring to "The pitch does not change
even if the TEMPO slider knob is
moved." If it does not have any
problem, replace the MAINPCB Assy.
If you move the TEMPO slider
knob while the TEMPO RESET
LED is unlit, do the strobe
patterns change?
Ye s
No
Is the LED (D312) on the MAIN
PCB Assy lit? If it is not, only the
LED (D312) may be damaged but
the TEMPO RESET button may
work properly. Replace the LED (D312).
No
Is the LED (D312) on the MAIN
PCB Assy lit? If it is not, only the
LED (D312) may be damaged but
the TEMPO RESET button may
work properly.
Replace the LED (D312).
Ye s
No
Replace the D308–311 on the
STROBOSCOPE Assy,
STROBOSCOPE Assy, or
AC&PLAY PCB Assy.
*Check method with the aid of a tester
When the VR is turned toward TEMPO +, the resistance between D318
and GND must become closer to 0 ohm.
The resistance between D316 and GND must be approximately 1.5 kohms.
When the VR is turned toward TEMPO –, the resistance between D318and
GND must be approximately 1.5 kohms. The resistance between D316 and
GND must become closer to 0 ohm.
Strobe Lock is not available.
Are the strobe LEDs lit?
Ye s
Ye s
Ye s
NoReplace VR301on the MAINPCB
Assy.
Does VR301 on the
MAINPCB Assy
work* properly?
Ye s
The VR data may not be input to the CPU or the motor may be
uncontrollable.
Replace the MAINPCB Assy then the D.D. MOTOR Assy, in that order.
The TEMPO Reset command may not be input to the CPU or the motor
may be uncontrollable. Replace the MAINPCB Assy then the D.D. MOTOR
Assy, in that order.
The TEMPO Range command may not be input to the CPU or the motor
may be uncontrollable.
Replace the MAINPCB Assy then the D.D. MOTOR Assy, in that order.
The same rotation speed is maintained.
1The VR data may not be input to the CPU. Check if VR301 on the MAIN
PCB Assy has any problem, referring to "The pitch does not change even
if the TEMPO slider knob is moved."
2The rotation speed may not be controlled properly.
Replace the MAINPCB Assy.
3The motor may be in failure. Replace the D.D. MOTOR Assy.
No
Does the TEMPO RESET LED
light or go dark when the TEMPO
RANGE button is pressed?
Replace the LED (D312) on the
MAINPCB Assy.
Replace the LED (D312) on the
MAINPCB Assy.
Ye s
Ye s
Ye s
No
Does the TEMPO RESET LED
light or go dark when the
SW301 on the MAINPCB Assy
is pressed?
Ye s
No
If you move the TEMPO slider knob to
the end of the + side while the TEMPO
RESET LED is unlit then press the
TEMPO RANGE button, is strobe locked?
If you move the TEMPO slider knob to
the end of the + side while the TEMPO
RESET LED is unlit then press the
TEMPO RANGE button, do the strobe
patterns change?
If you move the TEMPO slider knob to
the end of the + side while the TEMPO
RESET LED is unlit then press the
TEMPO RANGE button, do the
strobe patterns change?
[2] Abnormality regarding the operating elements and LEDs
NoRemove any foreign matter.
Is there any foreign
matter between the
turntable and motor?
NoRemove any foreign matter.
Is there any foreign
matter between the
turntable and motor?
Does the tact switch
(SW302) on the
MAINPCB Assy work?